Andita Nataria Fitri Ganda
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Andita Nataria Fitri Ganda has a total of 19 co-authors. Here are the top co-authors by number of shared publications:
- Adimashqi Maulana
Surabaya State University
1 shared publication - Aji Nugroho
Surabaya State University
1 shared publication - Anif Jamaluddin
Department of Physics, Faculty of Teacher Training and Education, Universitas Sebelas Maret, Surakarta, Indonesia
1 shared publication - Aris Al Nur Rachman
Surabaya State University
1 shared publication - Arya Mahendra Sakti
Surabaya State University
1 shared publication - Dewi Puspitasari
Universitas Negeri Surabaya
1 shared publication
Latest Publications
- 30 June 2026
- Published by Trans Tech Publications, Ltd. in Materials Science Forum
- Vol. 1196, 137-147
Environmentally Friendly Bioplastic Innovation Based on Banana Peel Waste as a Solution to Reduce Conventional Plastic
Conventional plastic waste poses a serious environmental problem due to its resistance to degradation. This study developed an eco-friendly bioplastic made from banana peel waste, reinforced with graphene oxide (GO) as a filler. The bioplastics were synthesized using the melt-blending method with GO concentrations of 0%, 0.5%, 1%, 1.5%, and 2%. Tensile strength tests showed that the bioplastic with 2% GO exhibited the highest mechanical performance, with a tensile strength of 26.15 N/cm 2 and a Young’s modulus of 130.73 MPa, compared to the non-graphene sample which only reached 22.64 N/cm 2 and 113.23 MPa. Biodegradability tests using the soil burial method over 6 days revealed that the non-graphene sample had the fastest degradation rate, with a weight loss of up to 45%, outperforming the graphene-reinforced variants. The results indicate that while GO enhances mechanical properties, it reduces the biodegradation rate. Therefore, banana peel-based bioplastic offers a promising, sustainable alternative to conventional plastics adaptable either for high-strength applications or for products designed to degrade more rapidly in natural environments.
- 30 June 2026
- Published by Trans Tech Publications, Ltd. in Materials Science Forum
- Vol. 1196, 137-147
Environmentally Friendly Bioplastic Innovation Based on Banana Peel Waste as a Solution to Reduce Conventional Plastic
Conventional plastic waste poses a serious environmental problem due to its resistance to degradation. This study developed an eco-friendly bioplastic made from banana peel waste, reinforced with graphene oxide (GO) as a filler. The bioplastics were synthesized using the melt-blending method with GO concentrations of 0%, 0.5%, 1%, 1.5%, and 2%. Tensile strength tests showed that the bioplastic with 2% GO exhibited the highest mechanical performance, with a tensile strength of 26.15 N/cm 2 and a Young’s modulus of 130.73 MPa, compared to the non-graphene sample which only reached 22.64 N/cm 2 and 113.23 MPa. Biodegradability tests using the soil burial method over 6 days revealed that the non-graphene sample had the fastest degradation rate, with a weight loss of up to 45%, outperforming the graphene-reinforced variants. The results indicate that while GO enhances mechanical properties, it reduces the biodegradation rate. Therefore, banana peel-based bioplastic offers a promising, sustainable alternative to conventional plastics adaptable either for high-strength applications or for products designed to degrade more rapidly in natural environments.
- Open Access
- 2 August 2025
- Published by Engineering, Technology & Applied Science Research in Engineering, Technology & Applied Science Research
- Vol. 15 (4) , 24904-24911
Power Parameter Analysis in the Electrochemical Graphite Exfoliation for Graphene Fabrication
Electrochemical exfoliation is considered an essential method for the rapid production of graphene in both high quality and quantity. This study investigates the electrochemical exfoliation of graphite rods, specifically the impact of the power variations in a Direct Current (DC) source on the quality of graphene. Furthermore, Scanning Electron Microscope-Energy Dispersive X-Ray (SEM-EDX) is employed to analyze the morphology and elemental composition. In addition, Fourier Transform Infrared (FTIR) spectroscopy is utilized to determine the functional groups of graphene. The defect of graphite is observed with Raman spectroscopy. The SEM results suggest that graphene layers are formed in all the power variations. Graphene at 98 W (G98) exhibits a wrinkle and cluttered surface compared to graphene at 70 W (G70) and graphene at 84 W (G84). Based on the FTIR results, the highest peak of C=O bond appeared in G70, while sharp peaks indicating O-H bonds are observed in G84 and G98. Furthermore, the power analysis is a critical factor affecting graphene mass production, with higher power levels resulting in higher graphene yield, but lower graphene quality by reducing the carbon (C) content and increasing Oxygen (O) content. This exploration contributes to advancing the understanding of the electrochemical exfoliation process, offering insights into optimizing the power parameters for enhanced graphene synthesis.
- 2 August 2025
- Published by Engineering, Technology & Applied Science Research in Engineering, Technology & Applied Science Research
- Vol. 15 (4) , 24904-24911
Open AccessPower Parameter Analysis in the Electrochemical Graphite Exfoliation for Graphene Fabrication
Electrochemical exfoliation is considered an essential method for the rapid production of graphene in both high quality and quantity. This study investigates the electrochemical exfoliation of graphite rods, specifically the impact of the power variations in a Direct Current (DC) source on the quality of graphene. Furthermore, Scanning Electron Microscope-Energy Dispersive X-Ray (SEM-EDX) is employed to analyze the morphology and elemental composition. In addition, Fourier Transform Infrared (FTIR) spectroscopy is utilized to determine the functional groups of graphene. The defect of graphite is observed with Raman spectroscopy. The SEM results suggest that graphene layers are formed in all the power variations. Graphene at 98 W (G98) exhibits a wrinkle and cluttered surface compared to graphene at 70 W (G70) and graphene at 84 W (G84). Based on the FTIR results, the highest peak of C=O bond appeared in G70, while sharp peaks indicating O-H bonds are observed in G84 and G98. Furthermore, the power analysis is a critical factor affecting graphene mass production, with higher power levels resulting in higher graphene yield, but lower graphene quality by reducing the carbon (C) content and increasing Oxygen (O) content. This exploration contributes to advancing the understanding of the electrochemical exfoliation process, offering insights into optimizing the power parameters for enhanced graphene synthesis.
- Open Access
- 1 February 2021
- Published by IOP Publishing in IOP Conference Series: Materials Science and Engineering
- Vol. 1034 (1) , 012158
Influence of surface roughness on corrosion behaviour of 316L stainless steel in artificial saliva and body fluid
The influence of surface roughness on the corrosion behaviour of 316L stainless steel in artificial saliva and body fluid was investigated in this study. Potentiodynamic polarization and EDAX composition test were used for observing the passive layer activity. The quality difference on steel 316LSS in saliva and blood may cause difference on the formation of passive layer. The result shows that the scratch formation which got rougher caused the uneven distribution of passive layer on the surface which caused the passive layer protection not optimum.
- 1 February 2021
- Published by IOP Publishing in IOP Conference Series: Materials Science and Engineering
- Vol. 1034 (1) , 012158
Open AccessInfluence of surface roughness on corrosion behaviour of 316L stainless steel in artificial saliva and body fluid
The influence of surface roughness on the corrosion behaviour of 316L stainless steel in artificial saliva and body fluid was investigated in this study. Potentiodynamic polarization and EDAX composition test were used for observing the passive layer activity. The quality difference on steel 316LSS in saliva and blood may cause difference on the formation of passive layer. The result shows that the scratch formation which got rougher caused the uneven distribution of passive layer on the surface which caused the passive layer protection not optimum.