Xiaoyang Tang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Xiaoyang Tang has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
- Lijun Xu
Beihang University
5 shared publications - Zhang Cao
School of Instrumentation and Opto-electronic Engineering, Beihang University, Beijing, China
5 shared publications - Lipei Cao
School of Instrumentation and Opto-electronic Engineering, Beihang University, Beijing, China
3 shared publications - Guangyu Hou
School of Instrumentation and Opto-electronic Engineering, Beihang University, Beijing, China
1 shared publication Heng Xie
School of Instrumentation and Opto-electronic Engineering, Beihang University, Beijing, China
1 shared publication- Shuang Qiu
School of Instrumentation and Opto-electronic Engineering, Beihang University, Beijing, China
1 shared publication
Latest Publications
- 21 June 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 73 (00189456) , 1-10
Transient 3-D Temperature Imaging From Multiwavelength Lateral Shearing Interferograms
Transient temperature field imaging was realized via lateral shearing interferograms at multiple wavelengths. Three lasers of different wavelengths were coupled to generate a multi-wavelength laser. Three phase difference distributions caused by the flame were initially extracted by identifying the centerline of the fringes, followed by three optical path difference distributions. An iterative correction method was introduced to improve the accuracy of the optical path difference. The refractive index image was reconstructed by using inverse Abel transform, and the temperature image was then retrieved. Numerical simulations were carried out for performance evaluations. Reconstruction errors of optical path difference and optical path distributions caused by the flame were 0.0241 and 0.0293, respectively. Images of refractive index and temperature were retrieved respectively with errors of 0.0465 and 0.0935. In experiments, interferometric temperatures for a steady flame produced by a Bunsen burner agreed well with the thermocouple readings. Dynamical flame extinguishment was captured at a frame rate of 20k fps. Temporal variations of average temperatures at different heights were visualized. The temperature distribution caused by a high-voltage pulsed glow discharging in less than 0.5 ms was also clearly imaged.
- 21 June 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 73 (00189456) , 1-10
Transient 3-D Temperature Imaging From Multiwavelength Lateral Shearing Interferograms
Transient temperature field imaging was realized via lateral shearing interferograms at multiple wavelengths. Three lasers of different wavelengths were coupled to generate a multi-wavelength laser. Three phase difference distributions caused by the flame were initially extracted by identifying the centerline of the fringes, followed by three optical path difference distributions. An iterative correction method was introduced to improve the accuracy of the optical path difference. The refractive index image was reconstructed by using inverse Abel transform, and the temperature image was then retrieved. Numerical simulations were carried out for performance evaluations. Reconstruction errors of optical path difference and optical path distributions caused by the flame were 0.0241 and 0.0293, respectively. Images of refractive index and temperature were retrieved respectively with errors of 0.0465 and 0.0935. In experiments, interferometric temperatures for a steady flame produced by a Bunsen burner agreed well with the thermocouple readings. Dynamical flame extinguishment was captured at a frame rate of 20k fps. Temporal variations of average temperatures at different heights were visualized. The temperature distribution caused by a high-voltage pulsed glow discharging in less than 0.5 ms was also clearly imaged.
- 28 August 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 72 (00189456) , 1-12
Parameter Fitting-Based Fast Imaging of Axisymmetric Flame Temperature Field Using Wavelength-Modulated Lateral Shearing Interferometry
A parameter fitting-based fast imaging method for axisymmetric flame temperature field was proposed in a lateral shearing interferometer. In the extinction state, a sawtooth waveform was used to modulate a distributed feedback (DFB) laser to obtain the quantitative mapping from modulated voltage to phase. In the combustion state, the laser was rapidly driven by an irregular waveform of five steps. Linear equations were established, and the phase difference caused by the flame at each pixel was extracted by parameter fitting. Flame phase distribution was obtained to image refractive indexes and temperatures. Compared with the existing waveform fitting-based wavelength modulation for flame monitoring, the proposed method reduced the modulation steps to five and improved the imaging speed up to eight times. In numerical simulations, an axisymmetric counterflow flame was reconstructed to evaluate the performance of the proposed method. Reconstruction errors of phase difference, refractive index and temperature distributions were 0.0117, 0.0692 and 0.0795, respectively. In experiments, three counterflow flames of different flow conditions were imaged. The flame structures were clearly visualized, and the interferometric temperatures matched well with the readings of a thermocouple. A Bunsen-type flame with 100-Hz acoustic excitation was monitored at 8 kHz. The variation of the temperature distributions well reflected the flame oscillations. The frequencies of fundamental, second and third harmonics were captured, and the harmonic at 99.43 Hz caused by the acoustic excitation was also precisely identified.
- 28 August 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 72 (00189456) , 1-12
Parameter Fitting-Based Fast Imaging of Axisymmetric Flame Temperature Field Using Wavelength-Modulated Lateral Shearing Interferometry
A parameter fitting-based fast imaging method for axisymmetric flame temperature field was proposed in a lateral shearing interferometer. In the extinction state, a sawtooth waveform was used to modulate a distributed feedback (DFB) laser to obtain the quantitative mapping from modulated voltage to phase. In the combustion state, the laser was rapidly driven by an irregular waveform of five steps. Linear equations were established, and the phase difference caused by the flame at each pixel was extracted by parameter fitting. Flame phase distribution was obtained to image refractive indexes and temperatures. Compared with the existing waveform fitting-based wavelength modulation for flame monitoring, the proposed method reduced the modulation steps to five and improved the imaging speed up to eight times. In numerical simulations, an axisymmetric counterflow flame was reconstructed to evaluate the performance of the proposed method. Reconstruction errors of phase difference, refractive index and temperature distributions were 0.0117, 0.0692 and 0.0795, respectively. In experiments, three counterflow flames of different flow conditions were imaged. The flame structures were clearly visualized, and the interferometric temperatures matched well with the readings of a thermocouple. A Bunsen-type flame with 100-Hz acoustic excitation was monitored at 8 kHz. The variation of the temperature distributions well reflected the flame oscillations. The frequencies of fundamental, second and third harmonics were captured, and the harmonic at 99.43 Hz caused by the acoustic excitation was also precisely identified.
- 9 November 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 71 (00189456) , 1-11
Fast and Calibration-Free Temperature Imaging of Dynamic Flames via Wavelength Modulated Lateral Shearing Interferometry
Temperature distributions of dynamical flames were measured by using a proposed calibration-free wavelength modulated lateral shearing interferometry. A distributed feedback (DFB) laser was modulated in the wavelength as a sawtooth profile. The wrapped flame phase in the images was obtained pixel by pixel by calculating the phase shift between the interference light intensity profiles before and after flame ignition. Phase unwrapping and recovery were adopted to solve the flame phase distribution. The refractive index distribution was reconstructed with the help of Inverse Abel transform. The temperature imaging was further achieved by the ideal gas law and Gladstone-Dale model. Numerical simulations were conducted for performance evaluations. The flame phase, refractive index and temperature distributions were reconstructed with errors of 0.0094, 0.0154 and 0.0958, respectively. Standard deviations were in the magnitude of 10 -4 at the presence of Gaussian random noises and showed the noise immunity of the proposed method. In actual experiments, reconstructed temperature distribution of a steady flame generated on a Bunsen burner agreed well with the thermocouple measurements. A dynamical process of flame extinguishment was portrayed at one kilo frames per second. Temporal variation of the flame temperature distribution well reflected the extinguishing process. The entire measurement process did not require prior calibration of the modulated wavelength, and the imaging speed was more than ten times faster than the existing phase modulated interferometer. The proposed method can be used for on-line evaluation of dynamic flames.
- 9 November 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 71 (00189456) , 1-11
Fast and Calibration-Free Temperature Imaging of Dynamic Flames via Wavelength Modulated Lateral Shearing Interferometry
Temperature distributions of dynamical flames were measured by using a proposed calibration-free wavelength modulated lateral shearing interferometry. A distributed feedback (DFB) laser was modulated in the wavelength as a sawtooth profile. The wrapped flame phase in the images was obtained pixel by pixel by calculating the phase shift between the interference light intensity profiles before and after flame ignition. Phase unwrapping and recovery were adopted to solve the flame phase distribution. The refractive index distribution was reconstructed with the help of Inverse Abel transform. The temperature imaging was further achieved by the ideal gas law and Gladstone-Dale model. Numerical simulations were conducted for performance evaluations. The flame phase, refractive index and temperature distributions were reconstructed with errors of 0.0094, 0.0154 and 0.0958, respectively. Standard deviations were in the magnitude of 10 -4 at the presence of Gaussian random noises and showed the noise immunity of the proposed method. In actual experiments, reconstructed temperature distribution of a steady flame generated on a Bunsen burner agreed well with the thermocouple measurements. A dynamical process of flame extinguishment was portrayed at one kilo frames per second. Temporal variation of the flame temperature distribution well reflected the extinguishing process. The entire measurement process did not require prior calibration of the modulated wavelength, and the imaging speed was more than ten times faster than the existing phase modulated interferometer. The proposed method can be used for on-line evaluation of dynamic flames.
- 20 September 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 71 (00189456) , 1-10
Optimal Absorption Lines Selection for Gas Temperature Measurement by Using Two-Color Laser Absorption Spectroscopy
Tunable diode laser absorption spectroscopy (TDLAS) is widely used in gas temperature measurement. A two-color method is typically utilized to extract the gaseous temperature in TDLAS. The accuracy of two-color method is greatly determined by the selection of two absorption lines. A selection method of optimal absorption lines for two-color temperature measurement was proposed. All available spectral lines are classified and grouped to speed up the selection on the cloud supercomputer. A temperature error model was established to evaluate the performances of different line pairs. The candidate line pair was selected and randomly verified among the representative line pairs from all line groups until the optimal line pair is determined. Typical line pair selections in the literature are used to compare the temperature errors with the optimally selected line pairs in this work. Spectral lines of H2O, CO2, and CO were involved in the temperature ranging from room temperature to 2000 K. The error of optimal spectral line selected by using the proposed method is usually 10 K smaller than the spectral lines reported in the literature. Also, verification experiments were performed to measure a stable and uniform gas temperature. The experimental results verified that the optimal lines by using the proposed method in this work yield better performance than the typical lines, as the temperature errors in average were reduced to almost one half of the typical lines.
- 20 September 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 71 (00189456) , 1-10
Optimal Absorption Lines Selection for Gas Temperature Measurement by Using Two-Color Laser Absorption Spectroscopy
Tunable diode laser absorption spectroscopy (TDLAS) is widely used in gas temperature measurement. A two-color method is typically utilized to extract the gaseous temperature in TDLAS. The accuracy of two-color method is greatly determined by the selection of two absorption lines. A selection method of optimal absorption lines for two-color temperature measurement was proposed. All available spectral lines are classified and grouped to speed up the selection on the cloud supercomputer. A temperature error model was established to evaluate the performances of different line pairs. The candidate line pair was selected and randomly verified among the representative line pairs from all line groups until the optimal line pair is determined. Typical line pair selections in the literature are used to compare the temperature errors with the optimally selected line pairs in this work. Spectral lines of H2O, CO2, and CO were involved in the temperature ranging from room temperature to 2000 K. The error of optimal spectral line selected by using the proposed method is usually 10 K smaller than the spectral lines reported in the literature. Also, verification experiments were performed to measure a stable and uniform gas temperature. The experimental results verified that the optimal lines by using the proposed method in this work yield better performance than the typical lines, as the temperature errors in average were reduced to almost one half of the typical lines.
- 9 March 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 70 (00189456) , 1-12
Retrieval of Phase and Temperature Distributions in Axisymmetric Flames From Phase-Modulated Large Lateral Shearing Interferogram
A precise phase modulation and demodulation method was proposed to retrieve temperature distributions in axisymmetric flames by using a single-wavelength large lateral shearing interferometer. A spatial light modulator (SLM) was employed to vary the phases in each pixel continuously in the flame-phase measurement. The uniqueness of the phase extraction was mathematically proved for the first time, and a least square method was applied to recover the profile of flame phase in the interferometer. The ambiguity of the phases at different cycles of $2\pi $ was eliminated. The phase shift at each pixel was uniquely determined and verified by using simulated data. Further, precise-phase distributions were utilized to retrieve the temperature distribution in a laminar flame. In actual experiments, four axisymmetric laminar flames from diffused to premixed flames were generated by using a Bunsen burner. Profiles of temperature distribution in the flames were extracted and agreed well with the results scanned by using a thermocouple. With the increase of airflow rate, the position of high-temperature zone was observed moving down, and the thermal structure of the premixed flame became more and more obvious. The preheating zone, reaction front, and reaction zone inside the flames were clearly captured.
- 9 March 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 70 (00189456) , 1-12
Retrieval of Phase and Temperature Distributions in Axisymmetric Flames From Phase-Modulated Large Lateral Shearing Interferogram
A precise phase modulation and demodulation method was proposed to retrieve temperature distributions in axisymmetric flames by using a single-wavelength large lateral shearing interferometer. A spatial light modulator (SLM) was employed to vary the phases in each pixel continuously in the flame-phase measurement. The uniqueness of the phase extraction was mathematically proved for the first time, and a least square method was applied to recover the profile of flame phase in the interferometer. The ambiguity of the phases at different cycles of $2\pi $ was eliminated. The phase shift at each pixel was uniquely determined and verified by using simulated data. Further, precise-phase distributions were utilized to retrieve the temperature distribution in a laminar flame. In actual experiments, four axisymmetric laminar flames from diffused to premixed flames were generated by using a Bunsen burner. Profiles of temperature distribution in the flames were extracted and agreed well with the results scanned by using a thermocouple. With the increase of airflow rate, the position of high-temperature zone was observed moving down, and the thermal structure of the premixed flame became more and more obvious. The preheating zone, reaction front, and reaction zone inside the flames were clearly captured.