Tao Zhang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Tao Zhang has a total of 28 co-authors. Here are the top co-authors by number of shared publications:
- Calvin Sze Hang Ng
Division of Cardiothoracic Surgery, Department of Surgery, The Chinese University of Hong Kong, Prince of Wales Hospital
2 shared publications Jianyang Zhu
2 shared publications- Jixiu Li
Department of Surgery, The Chinese University of Hong Kong, Hong Kong, China
2 shared publications - Philip Wai Yan Chiu
Division of Upper GI and Metabolic Surgery Department of Surgery The Chinese University of Hong Kong Shatin Hong Kong
2 shared publications - Truman Cheng
Department of Surgery, Chinese University of Hong Kong, Hong Kong
2 shared publications - Zheng Li
The Chinese University of Hong Kong
2 shared publications
Latest Publications
- 3 October 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Robotics and Bionics
- Vol. 6 (4) , 1397-1400
Design, Analysis, and Preliminary Validation of Magnetic Anchored and Cable Driven Endoscope for Minimally Invasive Surgery
Magnetic anchored and guided system(MAGS) is a promising solution for minimally invasive surgery, particularly in the realm of endoscope robotics. However, the inherent tight tissue contact in MAGS limits certain degrees of freedom, constraining the surgeon’s ability to adjust the field of view. To address this, we propose a novel solution by combining magnetic actuation with a cable-driven flexible link. Our study encompasses the design, analysis of magnetic force/torque, and kinematics of the flexible link. One prototype was fabricated, and experiments, including the evaluation of magnetic coupling performance and the motion of the flexible link, were conducted. These experiments validated both the theoretical modeling and the functionality of the magnetic endoscope system.
- 3 October 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Robotics and Bionics
- Vol. 6 (4) , 1397-1400
Design, Analysis, and Preliminary Validation of Magnetic Anchored and Cable Driven Endoscope for Minimally Invasive Surgery
Magnetic anchored and guided system(MAGS) is a promising solution for minimally invasive surgery, particularly in the realm of endoscope robotics. However, the inherent tight tissue contact in MAGS limits certain degrees of freedom, constraining the surgeon’s ability to adjust the field of view. To address this, we propose a novel solution by combining magnetic actuation with a cable-driven flexible link. Our study encompasses the design, analysis of magnetic force/torque, and kinematics of the flexible link. One prototype was fabricated, and experiments, including the evaluation of magnetic coupling performance and the motion of the flexible link, were conducted. These experiments validated both the theoretical modeling and the functionality of the magnetic endoscope system.
- 14 March 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE/ASME Transactions on Mechatronics
- Vol. 29 (6) , 4228-4239
Design, Analysis, and Kinematic Framework of a Long-Range Magnetic Anchored and Guided Endoscope
Magnetic anchored and guided systems (MAGS), such as endoscopes, have attracted significant research interest for their potential in minimally invasive surgeries (MIS). However, their widespread adoption is hindered by challenges, including magnetic interference, safe anchoring distance, and intuitive control. This article presents a novel magnetic coupling method using two cylindrical magnets and one semicylindrical magnet in both the external and internal magnetic modules. Magnetic field distribution and force interactions were modeled by combining magnetic dipole models and coordinate transformations. A kinematic framework was proposed, treating magnetic couplings as unique joints and links, thereby enabling the MAGS endoscope to execute a multitude of tasks. To validate the proposed design, a MAGS endoscope prototype was developed and evaluated through simulations and experiments. Results demonstrated improvements over conventional designs, including an average magnetic field asymmetry ratio of 2.09, reducing magnetic interference. The anchoring force is increased by 97%, with a safe anchoring distance of up to 95 mm for a 25-g endoscope. A mock-up lung surgery with automatic visual guidance confirmed the effectiveness of the kinematic modeling framework. This research contributes to overcoming MAGS implementation challenges, offering a promising approach to enhance MAGS endoscope performance in MIS procedures.
- 14 March 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE/ASME Transactions on Mechatronics
- Vol. 29 (6) , 4228-4239
Design, Analysis, and Kinematic Framework of a Long-Range Magnetic Anchored and Guided Endoscope
Magnetic anchored and guided systems (MAGS), such as endoscopes, have attracted significant research interest for their potential in minimally invasive surgeries (MIS). However, their widespread adoption is hindered by challenges, including magnetic interference, safe anchoring distance, and intuitive control. This article presents a novel magnetic coupling method using two cylindrical magnets and one semicylindrical magnet in both the external and internal magnetic modules. Magnetic field distribution and force interactions were modeled by combining magnetic dipole models and coordinate transformations. A kinematic framework was proposed, treating magnetic couplings as unique joints and links, thereby enabling the MAGS endoscope to execute a multitude of tasks. To validate the proposed design, a MAGS endoscope prototype was developed and evaluated through simulations and experiments. Results demonstrated improvements over conventional designs, including an average magnetic field asymmetry ratio of 2.09, reducing magnetic interference. The anchoring force is increased by 97%, with a safe anchoring distance of up to 95 mm for a 25-g endoscope. A mock-up lung surgery with automatic visual guidance confirmed the effectiveness of the kinematic modeling framework. This research contributes to overcoming MAGS implementation challenges, offering a promising approach to enhance MAGS endoscope performance in MIS procedures.
- Open Access
- 1 November 2021
- Published by Elsevier in Energy Reports
- Vol. 7, 5074-5085
Improve the performance of a semi-active flapping airfoil power generator by adjusting both offsetting mass center displacement and changing pitching axis position
- 1 November 2021
- Published by Elsevier in Energy Reports
- Vol. 7, 5074-5085
Open AccessImprove the performance of a semi-active flapping airfoil power generator by adjusting both offsetting mass center displacement and changing pitching axis position
- 27 July 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 21 (18) , 19896-19903
An Efficient Calibration Method for Triaxial Gyroscope
This paper presents an efficient servomotor-aided calibration method for the triaxial gyroscope. The entire calibration process only requires approximately one minute, and does not require high-precision equipment. This method is based on the idea that the measurement of the gyroscope should be equal to the rotation speed of the servomotor. A six-observation experimental design is proposed to minimize the maximum variance of the estimated scale factors and biases. In addition, a fast converging recursive linear least square estimation method is presented to reduce computational complexity. The simulation results reflect the robustness of the calibration method under normal and extreme conditions. We experimentally demonstrate the feasibility of the proposed method on a robot arm, and implement the method on a microcontroller. We verify the calibration results of the proposed method by comparing with a traditional turntable approach, and the experiment indicates that the results of these two methods are comparable. By comparing the calibrated low-cost gyroscope reading with the reading from a high-precision gyroscope, we can conclude that our method significantly increases the gyroscope’s accuracy.
- 27 July 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 21 (18) , 19896-19903
An Efficient Calibration Method for Triaxial Gyroscope
This paper presents an efficient servomotor-aided calibration method for the triaxial gyroscope. The entire calibration process only requires approximately one minute, and does not require high-precision equipment. This method is based on the idea that the measurement of the gyroscope should be equal to the rotation speed of the servomotor. A six-observation experimental design is proposed to minimize the maximum variance of the estimated scale factors and biases. In addition, a fast converging recursive linear least square estimation method is presented to reduce computational complexity. The simulation results reflect the robustness of the calibration method under normal and extreme conditions. We experimentally demonstrate the feasibility of the proposed method on a robot arm, and implement the method on a microcontroller. We verify the calibration results of the proposed method by comparing with a traditional turntable approach, and the experiment indicates that the results of these two methods are comparable. By comparing the calibrated low-cost gyroscope reading with the reading from a high-precision gyroscope, we can conclude that our method significantly increases the gyroscope’s accuracy.
- 1 October 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 450-455
A Fast Time Domain Measuring Technique of Electrochemical Impedance Spectroscopy Based on FFT
Lithium-ion batteries have become critical components to industries as automotive, military, space, medical and consumer electronics. Electrochemical impedance spectroscopy (EIS) is a well-known technique employed on various electrochemical cells including lithium-ion cells, which is practical in estimating battery state of health, as ohmic resistance, formation of solid electrolyte interphase (SEI) film, activation on solid and liquid interface and diffusion process in the battery can be reflected in the Nyquist curve of EIS. However, the long acquisition time of standard EIS makes it unsuitable for rapid on-line impedance measurements. This paper presents a time domain measuring technique based on Fast Fourier Transformation (FFT). Time domain excitation, such as a multi-sine excitation, is applied to the measured system. The excitation and response of the system are acquired simultaneously. Through FFT, acquired signals are transformed from time domain to frequency domain, thus the impedance in frequency domain is calculated. The technique is verified on both lithium-ion battery equivalent circuit and real lithium-ion battery. The resulting impedance data show that proposed technique has good concordance with standard EIS and greatly reduceds the acquisition time compared with standard EIS.
- 1 October 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 450-455
A Fast Time Domain Measuring Technique of Electrochemical Impedance Spectroscopy Based on FFT
Lithium-ion batteries have become critical components to industries as automotive, military, space, medical and consumer electronics. Electrochemical impedance spectroscopy (EIS) is a well-known technique employed on various electrochemical cells including lithium-ion cells, which is practical in estimating battery state of health, as ohmic resistance, formation of solid electrolyte interphase (SEI) film, activation on solid and liquid interface and diffusion process in the battery can be reflected in the Nyquist curve of EIS. However, the long acquisition time of standard EIS makes it unsuitable for rapid on-line impedance measurements. This paper presents a time domain measuring technique based on Fast Fourier Transformation (FFT). Time domain excitation, such as a multi-sine excitation, is applied to the measured system. The excitation and response of the system are acquired simultaneously. Through FFT, acquired signals are transformed from time domain to frequency domain, thus the impedance in frequency domain is calculated. The technique is verified on both lithium-ion battery equivalent circuit and real lithium-ion battery. The resulting impedance data show that proposed technique has good concordance with standard EIS and greatly reduceds the acquisition time compared with standard EIS.
- 13 August 2015
- Published by Optica Publishing Group in Applied Optics
- Vol. 54 (24) , 7308-7315
Reducing coherent noise in interference systems using the phase modulation technique
The phase modulation technique is adopted to reduce the coherent noise that arises from spurious interference. By choosing an appropriate driving signal, the method can reduce the coherent function of coherent noise to a great degree while keeping the coherent function of a coherent signal nearly unchanged. Simulation results show that for the grating interferometer, the phase error caused by coherent noise is reduced by 81.53% on average. For the Twyman interferometer, the fringe quality and contrast deteriorated by coherent noise are significantly improved. Furthermore, an experiment is set up in the phase-modulated Twyman interferometer to verify the feasibility of the principle. It is concluded that the method is effective to reduce the coherent noise in interference systems.
- 13 August 2015
- Published by Optica Publishing Group in Applied Optics
- Vol. 54 (24) , 7308-7315
Reducing coherent noise in interference systems using the phase modulation technique
The phase modulation technique is adopted to reduce the coherent noise that arises from spurious interference. By choosing an appropriate driving signal, the method can reduce the coherent function of coherent noise to a great degree while keeping the coherent function of a coherent signal nearly unchanged. Simulation results show that for the grating interferometer, the phase error caused by coherent noise is reduced by 81.53% on average. For the Twyman interferometer, the fringe quality and contrast deteriorated by coherent noise are significantly improved. Furthermore, an experiment is set up in the phase-modulated Twyman interferometer to verify the feasibility of the principle. It is concluded that the method is effective to reduce the coherent noise in interference systems.
- 1 July 2008
- Published by Elsevier in Journal of Neuroscience Methods
- Vol. 172 (1) , 131-136
Long-range correlation of renal sympathetic nerve activity in both conscious and anesthetized rats
- 1 July 2008
- Published by Elsevier in Journal of Neuroscience Methods
- Vol. 172 (1) , 131-136
Long-range correlation of renal sympathetic nerve activity in both conscious and anesthetized rats