Artem Iatsenko
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Artem Iatsenko has a total of 15 co-authors. Here are the top co-authors by number of shared publications:
- Olena Sych
Frantsevich Institute for Problems of Materials Science of National Academy of Sciences of Ukraine
4 shared publications - Andrii S. Nikolenko
V E Lashkaryov Institute of Semiconductor Physics NAS of Ukraine
2 shared publications - Anna Synytsia
Frantsevich Institute for Problems of Materials Science, National Academy of Sciences of Ukraine, Kyiv, Ukraine
2 shared publications - Oleksandr Bykov
NAS Ukraine, IM Frantsevich Inst Problems Mat Sci, 3 Pritsaka Str, UA-03142 Kiev, Ukraine
2 shared publications - Anatolii Perekos
Institute for Metal Physics of NAS of Ukraine
1 shared publication N. Boshytska
Department of Functional Materials for Medical Application, Frantsevich Institute for Problems of Materials Science of NAS of Ukraine, Kyiv, Ukraine
1 shared publication
Latest Publications
- Open Access
- 8 August 2024
- Published by Elsevier in Results in Surfaces and Interfaces
- Vol. 16
Structure Investigation of highly porous bioceramics based on biogenic hydroxyapatite with graphene oxide coating
- 8 August 2024
- Published by Elsevier in Results in Surfaces and Interfaces
- Vol. 16
Open AccessStructure Investigation of highly porous bioceramics based on biogenic hydroxyapatite with graphene oxide coating
- Open Access
- 29 July 2023
- Published by Springer Nature in Applied Nanoscience
- Vol. 13 (12) , 7477-7483
Structure and properties of biogenic hydroxyapatite bioceramics modified by graphene-like structures
Today bone tissue engineering is one of the most used technologies for treat bones injure. Materials containing hydroxyapatite and graphene have received much attention recently. The aim of this study was preparation of biogenic hydroxyapatite bioceramics modified by graphene-like structures investigation effect of graphene on the structure and properties of material. Biogenic hydroxyapatite bioceramics modified by graphene-like structures were successfully prepared by chemical vapor deposition (CVD) method. Subsequently, microstructure, composition, specific surface area, skeleton density, resorption rate in physiological solution and cytotoxicity were evaluated. XRD, IR spectroscopy, micro-Raman spectroscopy and SEM proved graphene oxide’s formation on biogenic hydroxyapatite as well as on silica single crystal for comparison. Although the coating of graphene-like structures on biogenic hydroxyapatite bioceramics reduces the specific surface area, it allows to 4 times increase resorption rate of biogenic hydroxyapatite bioceramics in physiological solution and does not affect the overall assessment of the cytotoxicity. MTT assay established non-cytotoxic effect and indicated a high potential of biogenic hydroxyapatite bioceramics modified by graphene-like structures using CVD method for medical application.
- 29 July 2023
- Published by Springer Nature in Applied Nanoscience
- Vol. 13 (12) , 7477-7483
Open AccessStructure and properties of biogenic hydroxyapatite bioceramics modified by graphene-like structures
Today bone tissue engineering is one of the most used technologies for treat bones injure. Materials containing hydroxyapatite and graphene have received much attention recently. The aim of this study was preparation of biogenic hydroxyapatite bioceramics modified by graphene-like structures investigation effect of graphene on the structure and properties of material. Biogenic hydroxyapatite bioceramics modified by graphene-like structures were successfully prepared by chemical vapor deposition (CVD) method. Subsequently, microstructure, composition, specific surface area, skeleton density, resorption rate in physiological solution and cytotoxicity were evaluated. XRD, IR spectroscopy, micro-Raman spectroscopy and SEM proved graphene oxide’s formation on biogenic hydroxyapatite as well as on silica single crystal for comparison. Although the coating of graphene-like structures on biogenic hydroxyapatite bioceramics reduces the specific surface area, it allows to 4 times increase resorption rate of biogenic hydroxyapatite bioceramics in physiological solution and does not affect the overall assessment of the cytotoxicity. MTT assay established non-cytotoxic effect and indicated a high potential of biogenic hydroxyapatite bioceramics modified by graphene-like structures using CVD method for medical application.
- Open Access
- 27 July 2023
- Published by Private Company Technology Center in Technology audit and production reserves
- Vol. 4 (3(72)) , 6-9
Development of improved technology for producing graphene-like coating by LPCVD method
The object of research in this work was the coating of oxygraphene on a silicon single crystal substrate. In the work, the LPСVD (Low Pressure Chemical Vapor Deposition) method of deposition from the gas phase at low pressure is used to obtain graphene-like coatings on heat-resistant materials. A feature of the proposed LPCVD method in comparison with the classical method of deposition from the gas phase CVD (Chemical Vapor Deposition) by the method of catalytic decomposition of carbon-containing gas followed by the deposition of a graphene-like coating on a copper template is the use of a higher partial gas pressure, which leads to the deposition of graphene-like waste not only on the surface of the copper template-catalyst, but also in the entire volume of the reaction chamber and the materials introduced into it. A monocrystalline silicon template was used as a model for coating. The resulting coatings of different thicknesses were examined by scanning electron microscopy, Raman spectroscopy, and density was assessed by helium pycnometry. Based on the analysis of the results obtained using the method of scanning electron microscopy, the possibility of varying the thickness of the oxygraphene coating was shown. In addition, the formation of oxygraphene on a silicon single crystal substrate was confirmed by the Raman spectroscopy method, namely the presence of characteristic peaks in the spectra of the studied materials. Using the helium pycnometry method, a decrease in the density of the coated material from 2.25 g/cm3 to 2.08 g/cm3 was found. It was established that the greater the coating thickness, the lower the density. The general analysis showed that the developed LPСVD technology allows obtaining an oxygraphene coating on materials of any shape, porosity, size and resistant to temperatures above 600 °С in order to functionalize their surface and improve and improve their properties.
- 27 July 2023
- Published by Private Company Technology Center in Technology audit and production reserves
- Vol. 4 (3(72)) , 6-9
Open AccessDevelopment of improved technology for producing graphene-like coating by LPCVD method
The object of research in this work was the coating of oxygraphene on a silicon single crystal substrate. In the work, the LPСVD (Low Pressure Chemical Vapor Deposition) method of deposition from the gas phase at low pressure is used to obtain graphene-like coatings on heat-resistant materials. A feature of the proposed LPCVD method in comparison with the classical method of deposition from the gas phase CVD (Chemical Vapor Deposition) by the method of catalytic decomposition of carbon-containing gas followed by the deposition of a graphene-like coating on a copper template is the use of a higher partial gas pressure, which leads to the deposition of graphene-like waste not only on the surface of the copper template-catalyst, but also in the entire volume of the reaction chamber and the materials introduced into it. A monocrystalline silicon template was used as a model for coating. The resulting coatings of different thicknesses were examined by scanning electron microscopy, Raman spectroscopy, and density was assessed by helium pycnometry. Based on the analysis of the results obtained using the method of scanning electron microscopy, the possibility of varying the thickness of the oxygraphene coating was shown. In addition, the formation of oxygraphene on a silicon single crystal substrate was confirmed by the Raman spectroscopy method, namely the presence of characteristic peaks in the spectra of the studied materials. Using the helium pycnometry method, a decrease in the density of the coated material from 2.25 g/cm3 to 2.08 g/cm3 was found. It was established that the greater the coating thickness, the lower the density. The general analysis showed that the developed LPСVD technology allows obtaining an oxygraphene coating on materials of any shape, porosity, size and resistant to temperatures above 600 °С in order to functionalize their surface and improve and improve their properties.
- 23 March 2021
- Published by Springer Nature in Applied Nanoscience
- Vol. 12 (4) , 929-937
Effect of type and parameters of synthesis on the properties of magnetite nanoparticles
- 23 March 2021
- Published by Springer Nature in Applied Nanoscience
- Vol. 12 (4) , 929-937
Effect of type and parameters of synthesis on the properties of magnetite nanoparticles
- Open Access
- 1 January 2015
- Published by National Library of Serbia in Processing and Application of Ceramics
- Vol. 9 (2) , 99-105
Effect of sintering temperature on structure and properties of highly porous glass-ceramics
Highly porous biomaterials with a structure close to that of cancellous bone have been prepared using biogenic hydroxyapatite and glass of the SiO2-Na2O-CaO system by a replication of the polymer template structure. It has been established that during sintering of the samples the hydroxyapatite decomposes, which involves the formation of glass-ceramics containing phases of renanit NaCaPO4, calcium phosphate silicate Ca5(PO4)2SiO4, calcium pyrophosphate Ca2P2O7 and impurities of hydroxyapatite Ca5(PO4)3(OH). Structural characteristics and mechanical properties of the obtained materials are promising for the replacement of defective cancellous bone.
- 1 January 2015
- Published by National Library of Serbia in Processing and Application of Ceramics
- Vol. 9 (2) , 99-105
Open AccessEffect of sintering temperature on structure and properties of highly porous glass-ceramics
Highly porous biomaterials with a structure close to that of cancellous bone have been prepared using biogenic hydroxyapatite and glass of the SiO2-Na2O-CaO system by a replication of the polymer template structure. It has been established that during sintering of the samples the hydroxyapatite decomposes, which involves the formation of glass-ceramics containing phases of renanit NaCaPO4, calcium phosphate silicate Ca5(PO4)2SiO4, calcium pyrophosphate Ca2P2O7 and impurities of hydroxyapatite Ca5(PO4)3(OH). Structural characteristics and mechanical properties of the obtained materials are promising for the replacement of defective cancellous bone.