Neerja Kushwaha
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Neerja Kushwaha has a total of 31 co-authors. Here are the top co-authors by number of shared publications:
- Akshaya Tomar
Dept of Immunohematology & Blood Transfusion, Armed Forces Medical College, Pune, India
4 shared publications Joseph Philip
Department of Transfusion Medicine, Bharati Vidyapeeth University, Pune, Maharashtra, India
4 shared publications- Amit Ajay Pawar
Associate Professor, Department of IH & BT, Armed Forces Medical College, Pune, India
3 shared publications Amit Kumar Biswas
Department of Immunohematology and Blood Transfusion, Armed Forces Medical College, Pune, Maharashtra, India
3 shared publicationsSanjeevan Sharma
Department of Medicine, Consultant Medicine and Hematology, Command Hospital Central Command, Lucknow, Uttar Pradesh, India
3 shared publications- Abbas Ghazi Naqvi
Department of Immunohematology and Blood Transfusion Armed Forces Medical College Pune Maharashtra India
2 shared publications
Latest Publications
- 28 June 2026
- Published by Wiley in Journal of Clinical Apheresis
- Vol. 41 (4) , e70152
Thrombocytapheresis as a Bridge Intervention in JAK2 ‐Mutant Myeloproliferative Neoplasm Complicated by Acquired von Willebrand Disease: A Case Report
Acquired von Willebrand disease (AvWD) in myeloproliferative neoplasms with extreme thrombocytosis causes paradoxical bleeding due to the mechanism of adsorption and ADAMTS13‐mediated proteolysis of high‐molecular‐weight von Willebrand factor (vWF) multimers. When first‐line cytoreductive therapy fails due to intolerance or nonadherence, rapid alternatives are limited. We describe a 74‐year‐old woman with JAK2V617F‐mutated myeloproliferative neoplasm and hydroxyurea intolerance who presented with active mucosal bleeding and a platelet count of 952 000/μL. vWF antigen (vWF:Ag) was 0.37 IU/mL (reference range: 0.50–2.00 IU/mL), and vWF Ristocetin Cofactor activity (vWF:RCo) was 0.21 IU/mL (activity/antigen ratio 0.57; reference range 0.7–1.3), consistent with AvWD. A single thrombocytapheresis session on the Fresenius COM.TEC platform reduced the platelet count to 277 000/μL, with prompt cessation of bleeding. Repeat testing at 24 h showed improvement in vWF:RCo to 0.48 IU/mL (ratio 0.68), which likely reflects restoration of functional high‐molecular‐weight multimers. In this single case, thrombocytapheresis provided rapid and effective platelet reduction for AvWD secondary to myeloproliferative neoplasms when pharmacological cytoreduction is inadequate.
- 28 June 2026
- Published by Wiley in Journal of Clinical Apheresis
- Vol. 41 (4) , e70152
Thrombocytapheresis as a Bridge Intervention in JAK2 ‐Mutant Myeloproliferative Neoplasm Complicated by Acquired von Willebrand Disease: A Case Report
Acquired von Willebrand disease (AvWD) in myeloproliferative neoplasms with extreme thrombocytosis causes paradoxical bleeding due to the mechanism of adsorption and ADAMTS13‐mediated proteolysis of high‐molecular‐weight von Willebrand factor (vWF) multimers. When first‐line cytoreductive therapy fails due to intolerance or nonadherence, rapid alternatives are limited. We describe a 74‐year‐old woman with JAK2V617F‐mutated myeloproliferative neoplasm and hydroxyurea intolerance who presented with active mucosal bleeding and a platelet count of 952 000/μL. vWF antigen (vWF:Ag) was 0.37 IU/mL (reference range: 0.50–2.00 IU/mL), and vWF Ristocetin Cofactor activity (vWF:RCo) was 0.21 IU/mL (activity/antigen ratio 0.57; reference range 0.7–1.3), consistent with AvWD. A single thrombocytapheresis session on the Fresenius COM.TEC platform reduced the platelet count to 277 000/μL, with prompt cessation of bleeding. Repeat testing at 24 h showed improvement in vWF:RCo to 0.48 IU/mL (ratio 0.68), which likely reflects restoration of functional high‐molecular‐weight multimers. In this single case, thrombocytapheresis provided rapid and effective platelet reduction for AvWD secondary to myeloproliferative neoplasms when pharmacological cytoreduction is inadequate.
- Open Access
- 1 July 2023
- Published by Jaypee Brothers Medical Publishing in Global Journal of Transfusion Medicine
- Vol. 8 (2) , 139-145
Blood Transfusion-Related Change in Circulating Plasma-Free Hemoglobin Levels and its Impact on Microvascular Oxygenation: A Prospective, Observational Study
Background and Objectives: Transfusion of stored, packed red blood cells (PRBCs) is a common therapeutic intervention; however, development of hemolysis during storage might contributes to some negative consequences due to the release of free hemoglobin (fHb), a potent nitric oxide scavenger, which may impair vasodilation and microcirculatory perfusion after transfusion. We undertook this study to find out the change in fHb levels in recipients, whether this affects microvascular oxygenation posttransfusion. Methods: Eighty stable transfusion recipients were selected for this prospective observational study and were divided into three groups as per the age of blood transfused (14 days). Blood samples were collected to analyze the plasma levels of fHb in the bag. The patient's circulating plasma Hb (FHb) and pO2 by venous blood gas analysis were studied before and after 1 h of transfusion. Data were analyzed through paired t-test, ANOVA, and Pearson's correlation coefficient using the SPSS version 23. Results: Overall, there was a significant difference between the three groups in terms of change in plasma fHb (g/dL) from pretransfusion to the 1 h posttransfusion time points (P < 0.05). Significant increase in pO2 Levels was noticed from the pretransfusion to 1 h posttransfusion time points in bags t = −4.6, P < 0.001). Furthermore, a strong negative correlation was obtained between FHb and pO2 using Pearson's correlation coefficient (r = −0.738; P < 0.001). Conclusion: This study concludes that red blood cell transfusion can significantly increase posttransfusion plasma Hb levels depending upon the age of PRBC units and has an implication on microvascular oxygenation. However, the effect on the clinical outcome of the patient was not studied, and it would be worthwhile to investigate whether the age of the blood transfused affects the patient morbidity or mortality.
- 1 July 2023
- Published by Jaypee Brothers Medical Publishing in Global Journal of Transfusion Medicine
- Vol. 8 (2) , 139-145
Open AccessBlood Transfusion-Related Change in Circulating Plasma-Free Hemoglobin Levels and its Impact on Microvascular Oxygenation: A Prospective, Observational Study
Background and Objectives: Transfusion of stored, packed red blood cells (PRBCs) is a common therapeutic intervention; however, development of hemolysis during storage might contributes to some negative consequences due to the release of free hemoglobin (fHb), a potent nitric oxide scavenger, which may impair vasodilation and microcirculatory perfusion after transfusion. We undertook this study to find out the change in fHb levels in recipients, whether this affects microvascular oxygenation posttransfusion. Methods: Eighty stable transfusion recipients were selected for this prospective observational study and were divided into three groups as per the age of blood transfused (14 days). Blood samples were collected to analyze the plasma levels of fHb in the bag. The patient's circulating plasma Hb (FHb) and pO2 by venous blood gas analysis were studied before and after 1 h of transfusion. Data were analyzed through paired t-test, ANOVA, and Pearson's correlation coefficient using the SPSS version 23. Results: Overall, there was a significant difference between the three groups in terms of change in plasma fHb (g/dL) from pretransfusion to the 1 h posttransfusion time points (P < 0.05). Significant increase in pO2 Levels was noticed from the pretransfusion to 1 h posttransfusion time points in bags t = −4.6, P < 0.001). Furthermore, a strong negative correlation was obtained between FHb and pO2 using Pearson's correlation coefficient (r = −0.738; P < 0.001). Conclusion: This study concludes that red blood cell transfusion can significantly increase posttransfusion plasma Hb levels depending upon the age of PRBC units and has an implication on microvascular oxygenation. However, the effect on the clinical outcome of the patient was not studied, and it would be worthwhile to investigate whether the age of the blood transfused affects the patient morbidity or mortality.
- Open Access
- 1 January 2023
- Published by Medknow in Asian Journal of Transfusion Science
- Vol. 17 (1) , 63-68
Comparative study of quality of leukoreduced packed red blood cell units as assessed by nageotte hemocytometry and flow cytometry
PURPOSE: Assessment of residual white blood cell (rWBC) count is vital to ascertain the quality of leukodepleted (LD) blood components. Automated cell analyzers lack the sensitivity for the assessment of very few leukocytes as found in LD blood components. Flow Cytometry (FC) based methods and Nageotte hemocytometer are the most commonly used techniques for this purpose. The objective of this study was to compare the use of Nageotte hemocytometer and FC for quality control of LD red blood cell units.MATERIALS AND METHODS: A prospective, observational study was conducted in the Department of Immunohematology and Blood Transfusion of a tertiary care center from September 2018 to September 2020. About 303 LD-packed red blood cell units were tested by FC and Nageotte hemocytometer for rWBCs.RESULTS: The number of rWBC (mean) detected by flow cytometer and Nageotte's hemocytometer was 1.06 ± 0.43 white blood cell (WBC)/μL and 0.67 ± 0.39 WBC/μL, respectively. Coefficient of variation was 58.37% by Nageotte hemocytometer method and 40.46% by FC. Linear regression analysis did not show any correlation (R2= 0.098,P= 0.001) whereas Pearson's correlation coefficient showed a weak relation (r = 0.31) between the two methods.CONCLUSION: Flow cytometric technique provides a more precise and accurate objective tool compared to Nageotte hemocytometer which is labor intensive, time consuming, and prone to errors arising out of subjectivity along with reported underestimation bias. In the absence of adequate infrastructure, resources, and trained workforce, Nageotte hemocytometer method is a reliable alternative. Nageotte's chamber could be best used in the resource-constrained setup as it offers a relatively inexpensive, simple, and viable means to enumerate rWBCs.
- 1 January 2023
- Published by Medknow in Asian Journal of Transfusion Science
- Vol. 17 (1) , 63-68
Open AccessComparative study of quality of leukoreduced packed red blood cell units as assessed by nageotte hemocytometry and flow cytometry
PURPOSE: Assessment of residual white blood cell (rWBC) count is vital to ascertain the quality of leukodepleted (LD) blood components. Automated cell analyzers lack the sensitivity for the assessment of very few leukocytes as found in LD blood components. Flow Cytometry (FC) based methods and Nageotte hemocytometer are the most commonly used techniques for this purpose. The objective of this study was to compare the use of Nageotte hemocytometer and FC for quality control of LD red blood cell units.MATERIALS AND METHODS: A prospective, observational study was conducted in the Department of Immunohematology and Blood Transfusion of a tertiary care center from September 2018 to September 2020. About 303 LD-packed red blood cell units were tested by FC and Nageotte hemocytometer for rWBCs.RESULTS: The number of rWBC (mean) detected by flow cytometer and Nageotte's hemocytometer was 1.06 ± 0.43 white blood cell (WBC)/μL and 0.67 ± 0.39 WBC/μL, respectively. Coefficient of variation was 58.37% by Nageotte hemocytometer method and 40.46% by FC. Linear regression analysis did not show any correlation (R2= 0.098,P= 0.001) whereas Pearson's correlation coefficient showed a weak relation (r = 0.31) between the two methods.CONCLUSION: Flow cytometric technique provides a more precise and accurate objective tool compared to Nageotte hemocytometer which is labor intensive, time consuming, and prone to errors arising out of subjectivity along with reported underestimation bias. In the absence of adequate infrastructure, resources, and trained workforce, Nageotte hemocytometer method is a reliable alternative. Nageotte's chamber could be best used in the resource-constrained setup as it offers a relatively inexpensive, simple, and viable means to enumerate rWBCs.
- 1 September 2022
- Published by Elsevier in Medical Journal Armed Forces India
- Vol. 78 (Suppl 1) , S226-S231
A retrospective audit to evaluate the appropriateness and rationalization of Fresh Frozen Plasma usage in a tertiary care hospital
- 1 September 2022
- Published by Elsevier in Medical Journal Armed Forces India
- Vol. 78 (Suppl 1) , S226-S231
A retrospective audit to evaluate the appropriateness and rationalization of Fresh Frozen Plasma usage in a tertiary care hospital
- 1 July 2022
- Published by Elsevier in Medical Journal Armed Forces India
- Vol. 78 (3) , 296-301
Association of CD 34 positive cell dose with engraftment kinetics in autologous peripheral blood stem cell transplant patients of multiple myeloma
- 1 July 2022
- Published by Elsevier in Medical Journal Armed Forces India
- Vol. 78 (3) , 296-301
Association of CD 34 positive cell dose with engraftment kinetics in autologous peripheral blood stem cell transplant patients of multiple myeloma
- Open Access
- 26 May 2022
- Published by Medknow in Asian Journal of Transfusion Science
- Vol. 17 (2) , 202-209
A retrospective study to assess the impact of ABO incompatibility on outcomes of allogeneic peripheral blood stem cell transplants at a tertiary care hospital in Western Maharashtra
BACKGROUND: Hematopoietic stem cell transplantation (HSCT) has emerged as a curative measure for life-threatening hematological disorders. It can be autologous or allogeneic depending on the disease characteristics. Providing transfusion support to the transplant patients can be challenging, especially in AB-mismatched allogeneic HSCT. In this study, we investigated the impact of ABO incompatibility in patients undergoing allogeneic HSCT.MATERIALS AND METHODS: A retrospective review was conducted in 76 patients with hematological diseases who underwent allogeneic HSCT. Transfusion requirements, engraftment profile, incidence of graft versus host disease (GvHD), and mortality for a period of 1 year were analyzed.RESULTS: ABO incompatibility between donor and the patient did not significantly affect the neutrophil and platelet (PLT) engraftment time (P= 0.389, 0.349, respectively), packed red blood cells transfusion requirement, and duration of initial hospital stay. However, patients of ABO-incompatible HSCT received more PLT transfusions posttransplant which was statistically significant. 29.1% of ABO compatible and 16.7% incompatible HSCT patients developed GVHD. Mortality rates in the two groups were 16.7% and 8.3%, respectively. However, differences in both the parameters were not statistically significant.CONCLUSION: Our study showed that ABO incompatibility does not significantly affect the outcome and should not be a limiting factor for selection of donor. Donor availability and human leukocyte antigen (HLA) matching remain the critical selection criteria.
- 26 May 2022
- Published by Medknow in Asian Journal of Transfusion Science
- Vol. 17 (2) , 202-209
Open AccessA retrospective study to assess the impact of ABO incompatibility on outcomes of allogeneic peripheral blood stem cell transplants at a tertiary care hospital in Western Maharashtra
BACKGROUND: Hematopoietic stem cell transplantation (HSCT) has emerged as a curative measure for life-threatening hematological disorders. It can be autologous or allogeneic depending on the disease characteristics. Providing transfusion support to the transplant patients can be challenging, especially in AB-mismatched allogeneic HSCT. In this study, we investigated the impact of ABO incompatibility in patients undergoing allogeneic HSCT.MATERIALS AND METHODS: A retrospective review was conducted in 76 patients with hematological diseases who underwent allogeneic HSCT. Transfusion requirements, engraftment profile, incidence of graft versus host disease (GvHD), and mortality for a period of 1 year were analyzed.RESULTS: ABO incompatibility between donor and the patient did not significantly affect the neutrophil and platelet (PLT) engraftment time (P= 0.389, 0.349, respectively), packed red blood cells transfusion requirement, and duration of initial hospital stay. However, patients of ABO-incompatible HSCT received more PLT transfusions posttransplant which was statistically significant. 29.1% of ABO compatible and 16.7% incompatible HSCT patients developed GVHD. Mortality rates in the two groups were 16.7% and 8.3%, respectively. However, differences in both the parameters were not statistically significant.CONCLUSION: Our study showed that ABO incompatibility does not significantly affect the outcome and should not be a limiting factor for selection of donor. Donor availability and human leukocyte antigen (HLA) matching remain the critical selection criteria.