Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Yong Luo has a total of 9 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Serum IL-6 and procalcitonin are two promising novel biomarkers for evaluating the severity of COVID-19 patients

    by Jinsong Tang, Jingtao Lin, Erying Zhang, Mengru Zhong, Yong Luo, Yong Fu, Yewei Yang

    To evaluate the development of coronavirus disease 2019 (COVID-19), the roles of interleukin 6 (IL-6) and procalcitonin (PCT) were assessed to diagnose severe COVID-19. Between January and February 2020, 100 consecutive patients with confirmed COVID-19 were included and divided into common (n = 56), severe (n = 28), and critical (n = 16) groups. IL-6 and PCT levels were assayed and compared among groups. IL-6 levels were significantly different among groups (common, 23.93±9.64 pg/mL; severe, 69.22 ± 22.98 pg/mL; critical, 160.34 ± 26.15 pg/mL; P < .05), and there was also a significant difference in the levels of PCT among groups (common, 0.23 ± 0.13 ng/mL; severe, 0.38 ± 0.16 ng/mL; critical, 0.73 ± 0.36 ng/mL; P < .05). Further analysis showed that patients in the critical group had the highest levels of IL-6 and PCT, and those in the common group had the lowest levels (all P < .05). IL-6 and PCT are associated with the severity of COVID-19, and thus have potential value in the diagnosis of COVID-19.


  • Open Access

    Development of quantum dot‐based fluorescence lateral flow immunoassay strip for rapid and quantitative detection of serum interleukin‐6

    by Jinsong Tang, Lili Wu, Jingtao Lin, Erying Zhang, Yong Luo

    Background: Interleukin‐6 (IL‐6) is an inflammatory factor that increases rapidly in response to infectious diseases including sepsis. The aim of this study is to develop a quantum dot (QD)‐based fluorescence lateral flow immunoassay (LFIA) strip that can rapidly and accurately detect IL‐6 levels.Methods: QD‐based LFIA strips were fabricated by conjugating CdSe/ZnS QDs to the IL‐6 antibody. Performance verification and clinical sample analysis were carried out to evaluate the newly developed strip.Results: QD‐based LFIA strips were successfully fabricated. The test strip's linear range was 10–4000 pg/ml, with a linear correlation coefficient of R2 ≥ .959. The sensitivity of the test strip was 1.995 pg/ml. The recovery rate was 95.72%–102.63%, indicating satisfying accuracy. The coefficient of variation (CV) of the intra‐assay was 2.148%–3.903%, while the inter‐assay was 2.412%–5.293%, verifying the strip's high precision. The cross‐reaction rates with various interleukins (IL‐1α, IL‐1β, IL‐2, IL‐4, and IL‐8) and interferon‐γ (IFN‐γ) were all n = 200, R2 = .9971) for the detection of IL‐6.Conclusions: The QD‐based test strip can rapidly and quantitatively detect IL‐6 levels, thus meeting the requirement of point‐of‐care test (POCT) and showing excellent clinical prospects.