Linghui Xu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Linghui Xu has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
- Bingfei Fan
College of Mechanical Engineering, Zhejiang University of Technology, Hangzhou, China
1 shared publication Canjun Yang
Zhejiang University
1 shared publication- Canjun Yang
Department of Mechanical Engineering, Zhejiang University, Hangzhou, China
1 shared publication - Elena M. Gutierrez-Farewik
KTH MoveAbility, Department of Engineering Mechanics, KTH Royal Institute of Technology, Stockholm, Sweden
1 shared publication Fei Wang
China Academy of Art
1 shared publication- George Andrikopoulos
KTH Royal Institute of Technology, Stockholm, Sweden
1 shared publication
Latest Publications
- Open Access
- 17 March 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Vol. 34 (15344320) , 1616-1625
Designing Active Assistance for Gait With Hip Abductors Weakness Using Predictive Simulation
Individuals with weak hip abductors commonly exhibit compensatory gait patterns and excessive lateral center of mass excursions, which may reduce walking efficiency and increase the risk of falling. In this study, we investigated the influence of hip abductor weakness and of ideal hip abduction assistive torque on gait patterns through an established predictive simulation framework and a full-body musculoskeletal model. Using this model and simulation framework, hip abductor muscle strength was reduced in several increments, and gait patterns were predicted and qualitatively compared to reported gait patterns in persons with weak hip abductors. Hip abductor assistive torque was then added to the model as ideal joint torques with three distinct time series profiles (step pattern, trapezoid pattern, and biological pattern). For each assistive torque pattern, timing and magnitude parameters were optimized in a bilevel optimization such that the predicted gait was normalized as much as possible. The key features of the predicted compensatory gait patterns were successfully captured in the simulation. All assistive torque profiles normalized gait kinematics relatively well, wherein the trapezoid and biological profiles normalized kinematics and reduced estimated costs of transport nearly equally well. Due to its simplicity and performance, the trapezoid profile can be considered as the most preferable. Our findings provide valuable insights into the impact of hip abductor weakness on compensatory gait, the potential benefits of hip abduction assistive torque, and the use of bilevel optimization to identify parameters that characterize optimal assistive torque, and can be useful in the exoskeleton control design for individuals with hip abductor weakness.
- 17 March 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Vol. 34 (15344320) , 1616-1625
Open AccessDesigning Active Assistance for Gait With Hip Abductors Weakness Using Predictive Simulation
Individuals with weak hip abductors commonly exhibit compensatory gait patterns and excessive lateral center of mass excursions, which may reduce walking efficiency and increase the risk of falling. In this study, we investigated the influence of hip abductor weakness and of ideal hip abduction assistive torque on gait patterns through an established predictive simulation framework and a full-body musculoskeletal model. Using this model and simulation framework, hip abductor muscle strength was reduced in several increments, and gait patterns were predicted and qualitatively compared to reported gait patterns in persons with weak hip abductors. Hip abductor assistive torque was then added to the model as ideal joint torques with three distinct time series profiles (step pattern, trapezoid pattern, and biological pattern). For each assistive torque pattern, timing and magnitude parameters were optimized in a bilevel optimization such that the predicted gait was normalized as much as possible. The key features of the predicted compensatory gait patterns were successfully captured in the simulation. All assistive torque profiles normalized gait kinematics relatively well, wherein the trapezoid and biological profiles normalized kinematics and reduced estimated costs of transport nearly equally well. Due to its simplicity and performance, the trapezoid profile can be considered as the most preferable. Our findings provide valuable insights into the impact of hip abductor weakness on compensatory gait, the potential benefits of hip abduction assistive torque, and the use of bilevel optimization to identify parameters that characterize optimal assistive torque, and can be useful in the exoskeleton control design for individuals with hip abductor weakness.
- 30 May 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Robotics and Bionics
- Vol. 6 (3) , 1135-1146
Wearable Continuous Gait Phase Estimation During Walking, Running, Turning, Stairs, and Over Uneven Terrain
Wearable continuous gait phase estimation is essential for walking assistance, clinical rehabilitation, and clinical assessment; however, most algorithms have only been validated for straight-line and constant-speed walking, and it is unclear how performance will change in real-life locomotion scenarios. A generalized paradigm is needed to comprehensively assess and recommend wearable continuous gait phase estimation strategies for the diverse array of walking situations. We thus propose a comprehensive evaluation indicator system for eight typical gait activities in daily life including slow walking, standard walking, running, walking with turns, stair descent, stair ascent, stop-and-go, and uneven terrain walking. The indicator system was used to evaluate four commonly used continuous gait phase estimation strategies: adaptive oscillators, phase oscillator, neural network, and time-based estimation. Eleven healthy participants were enrolled in the evaluation. All estimation strategies performed well for constant-speed walking but performance varied for other activities. Time-based estimation was most accurate for slow walking (0.094±0.011 rad root mean square error, 1.50±0.18% of one gait cycle), running (0.167±0.028 rad, 2.66±0.44%) and walking with turns (0.124±0.047 rad, 2.00±0.75%). Adaptive oscillators were most accurate for standard walking (0.115±0.037 rad, 1.83±0.59%). Phase oscillator was most accurate for stair climbing (0.280±0.063 rad, 4.46±1.00%) and uneven terrain (0.204±0.069 rad, 4.30±1.10%). Neural network was most accurate for stop-and-go (0.27±0.114 rad, 4.30±1.81%). These results can potentially provide guidance for determining suitable gait phase estimation strategies in realistic locomotion scenarios, and in comparing and optimizing the current proposed strategies.
- 30 May 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Robotics and Bionics
- Vol. 6 (3) , 1135-1146
Wearable Continuous Gait Phase Estimation During Walking, Running, Turning, Stairs, and Over Uneven Terrain
Wearable continuous gait phase estimation is essential for walking assistance, clinical rehabilitation, and clinical assessment; however, most algorithms have only been validated for straight-line and constant-speed walking, and it is unclear how performance will change in real-life locomotion scenarios. A generalized paradigm is needed to comprehensively assess and recommend wearable continuous gait phase estimation strategies for the diverse array of walking situations. We thus propose a comprehensive evaluation indicator system for eight typical gait activities in daily life including slow walking, standard walking, running, walking with turns, stair descent, stair ascent, stop-and-go, and uneven terrain walking. The indicator system was used to evaluate four commonly used continuous gait phase estimation strategies: adaptive oscillators, phase oscillator, neural network, and time-based estimation. Eleven healthy participants were enrolled in the evaluation. All estimation strategies performed well for constant-speed walking but performance varied for other activities. Time-based estimation was most accurate for slow walking (0.094±0.011 rad root mean square error, 1.50±0.18% of one gait cycle), running (0.167±0.028 rad, 2.66±0.44%) and walking with turns (0.124±0.047 rad, 2.00±0.75%). Adaptive oscillators were most accurate for standard walking (0.115±0.037 rad, 1.83±0.59%). Phase oscillator was most accurate for stair climbing (0.280±0.063 rad, 4.46±1.00%) and uneven terrain (0.204±0.069 rad, 4.30±1.10%). Neural network was most accurate for stop-and-go (0.27±0.114 rad, 4.30±1.81%). These results can potentially provide guidance for determining suitable gait phase estimation strategies in realistic locomotion scenarios, and in comparing and optimizing the current proposed strategies.
- Open Access
- 24 March 2021
- Published by Springer Nature in Research Square
Machine-learning-based children’s pathological gait classification with low-cost gait-recognition system
Background: Pathological gaits of children may lead to terrible diseases, such as osteoarthritis or scoliosis. By monitoring the gait pattern of a child, proper therapeutic measures can be recommended to avoid the terrible consequence. However, low-cost systems for pathological gait recognition of children automatically have not been on market yet. Our goal was to design a low-cost gait-recognition system for children with only pressure information.Methods: In this study, we design a pathological gait-recognition system (PGRS) with an 8 × 8 pressure-sensor array. An intelligent gait-recognition method (IGRM) based on machine learning and pure plantar pressure information is also proposed in static and dynamic sections to realize high accuracy and good real-time performance. To verifying the recognition effect, a total of seventeen children were recruited in the experiments wearing PGRS to recognize three pathological gaits (toe in, toe out, and flat) and normal gait. Children are asked to walk naturally on level ground in the dynamic section or stand naturally and comfortably in the static section. The evaluation of the performance of recognition results included stratified 10-fold cross-validation with recall, precision, and a time cost as metrics.Results: The experimental results show that all of the IGRMs have been identified with a practically applicable degree of average accuracy either in the dynamic or static section. Experimental results indicate that the IGRM has 92.41% and 97.79% recognition accuracy respectively in the static and dynamic sections. And we find methods in the static section have less recognition accuracy due to the unnatural gesture of children when standing.Conclusions: In this study, a low-cost PGRS has been verified and realize feasibility, highly average precision, and good real-time performance of gait recognition. The experimental results reveal the potential for the computer supervision of non-pathological and pathological gaits in the plantar-pressure patterns of children and for providing feedback in the application of gait-abnormality rectification.
- 24 March 2021
- Published by Springer Nature in Research Square
Open AccessMachine-learning-based children’s pathological gait classification with low-cost gait-recognition system
Background: Pathological gaits of children may lead to terrible diseases, such as osteoarthritis or scoliosis. By monitoring the gait pattern of a child, proper therapeutic measures can be recommended to avoid the terrible consequence. However, low-cost systems for pathological gait recognition of children automatically have not been on market yet. Our goal was to design a low-cost gait-recognition system for children with only pressure information.Methods: In this study, we design a pathological gait-recognition system (PGRS) with an 8 × 8 pressure-sensor array. An intelligent gait-recognition method (IGRM) based on machine learning and pure plantar pressure information is also proposed in static and dynamic sections to realize high accuracy and good real-time performance. To verifying the recognition effect, a total of seventeen children were recruited in the experiments wearing PGRS to recognize three pathological gaits (toe in, toe out, and flat) and normal gait. Children are asked to walk naturally on level ground in the dynamic section or stand naturally and comfortably in the static section. The evaluation of the performance of recognition results included stratified 10-fold cross-validation with recall, precision, and a time cost as metrics.Results: The experimental results show that all of the IGRMs have been identified with a practically applicable degree of average accuracy either in the dynamic or static section. Experimental results indicate that the IGRM has 92.41% and 97.79% recognition accuracy respectively in the static and dynamic sections. And we find methods in the static section have less recognition accuracy due to the unnatural gesture of children when standing.Conclusions: In this study, a low-cost PGRS has been verified and realize feasibility, highly average precision, and good real-time performance of gait recognition. The experimental results reveal the potential for the computer supervision of non-pathological and pathological gaits in the plantar-pressure patterns of children and for providing feedback in the application of gait-abnormality rectification.