Nikola Čajová Kantová
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Nikola Čajová Kantová has a total of 55 co-authors. Here are the top co-authors by number of shared publications:
- Michal Holubčík
Department of Power Engineering, Faculty of Mechanical Engineering, University of Zilina, Zilina, Slovakia
19 shared publications - Alexander Čaja
Department of Power Engineering, Faculty of Mechanical Engineering, University of Zilina, Univerzitna 1, 010 26 Zilina, Slovakia
16 shared publications - Alexander Backa
Research Centre, University of Žilina, Žilina, Slovakia
11 shared publications - Pavol Belany
University of Žilina
11 shared publications - Jozef Jandačka
Department of Power Engineering, Faculty of Mechanical Engineering, University of Zilina, Univerzitna 8215/1, 010 26 Zilina, Slovakia
10 shared publications Alexander Čaja
Department of Power Engineering, Faculty of Mechanical Engineering, University of Žilina, Univerzitná 8215/1, Žilina 010 26, Slovakia
6 shared publications
Latest Publications
- Open Access
Machine Learning-Based Operational Wear Index Estimation of LED Luminaires Using Measured Switching-Cycle Data
Reliable assessments of the operational conditions of LED lighting systems are important for maintenance planning and asset management. Conventional Wear Index (WI) approaches typically assume a fixed daily number of switching cycles, which may not accurately reflect actual operating conditions. This study proposes a machine learning-based framework for operational Wear Index estimation using measured switching-cycle data collected from an LED lighting installation. Daily energy consumption and operating time were predicted using Multiple Linear Regression (MLR), Random Forest (RF), Long Short-Term Memory (LSTM), and Backpropagation Neural Network (BPNN) models. The models were evaluated using consistent performance metrics, and the BPNN achieved the highest predictive accuracy and was subsequently applied to the Wear Index calculation. Incorporating measured daily switching activity instead of the conventional fixed assumption of nine switching cycles per day resulted in a 17.80% higher cumulative Wear Index. This result demonstrates that the representation of switching activity can materially influence operational wear assessment. The proposed framework provides a practical data-driven approach for estimating operational wear under actual operating conditions and may support maintenance planning in intelligent lighting systems. Since the results are based on a single monitored installation, they should be interpreted as a case study.
Open AccessMachine Learning-Based Operational Wear Index Estimation of LED Luminaires Using Measured Switching-Cycle Data
Reliable assessments of the operational conditions of LED lighting systems are important for maintenance planning and asset management. Conventional Wear Index (WI) approaches typically assume a fixed daily number of switching cycles, which may not accurately reflect actual operating conditions. This study proposes a machine learning-based framework for operational Wear Index estimation using measured switching-cycle data collected from an LED lighting installation. Daily energy consumption and operating time were predicted using Multiple Linear Regression (MLR), Random Forest (RF), Long Short-Term Memory (LSTM), and Backpropagation Neural Network (BPNN) models. The models were evaluated using consistent performance metrics, and the BPNN achieved the highest predictive accuracy and was subsequently applied to the Wear Index calculation. Incorporating measured daily switching activity instead of the conventional fixed assumption of nine switching cycles per day resulted in a 17.80% higher cumulative Wear Index. This result demonstrates that the representation of switching activity can materially influence operational wear assessment. The proposed framework provides a practical data-driven approach for estimating operational wear under actual operating conditions and may support maintenance planning in intelligent lighting systems. Since the results are based on a single monitored installation, they should be interpreted as a case study.
- Open Access
Numerical Analysis of Flow-Guiding Structures for Improving Gas Distribution in a Four-Tube Electrostatic Precipitator
Particulate matter from small-scale combustion systems remains a concern, as fine and submicron particles are difficult to remove by inertial separation alone. Electrostatic precipitators (ESP) are a promising option for this application. However, the effective aerodynamic utilization of the available collecting area depends on the internal distribution of particle-laden flue gas. This study numerically investigates the gas-flow distribution and aerodynamic particle transport in a four-tube ESP, designed to increase the collecting surface area relative to a conventional tubular arrangement. Three geometrical configurations were evaluated using computational fluid dynamics: a basic four-tube model without flow guidance, a model with nine radial inserts, and a model with a screw-type guiding structure positioned in the T-junction region. The basic geometry showed strongly non-uniform flow distribution, with a maximum-to-minimum tube-average velocity ratio of 3.31 and a coefficient of variation of approximately 51%. Radial inserts reduced these values to 1.95 and 27%, respectively, while the screw-type structure provided the most uniform distribution, with corresponding values of 1.75 and 20%. Particle-velocity fields indicated that the guiding elements promoted a more even particle supply to the four tubes. The results demonstrate that inlet-flow conditioning is essential for the effective aerodynamic utilization of the enlarged collecting area in multi-tube ESPs.
Open AccessNumerical Analysis of Flow-Guiding Structures for Improving Gas Distribution in a Four-Tube Electrostatic Precipitator
Particulate matter from small-scale combustion systems remains a concern, as fine and submicron particles are difficult to remove by inertial separation alone. Electrostatic precipitators (ESP) are a promising option for this application. However, the effective aerodynamic utilization of the available collecting area depends on the internal distribution of particle-laden flue gas. This study numerically investigates the gas-flow distribution and aerodynamic particle transport in a four-tube ESP, designed to increase the collecting surface area relative to a conventional tubular arrangement. Three geometrical configurations were evaluated using computational fluid dynamics: a basic four-tube model without flow guidance, a model with nine radial inserts, and a model with a screw-type guiding structure positioned in the T-junction region. The basic geometry showed strongly non-uniform flow distribution, with a maximum-to-minimum tube-average velocity ratio of 3.31 and a coefficient of variation of approximately 51%. Radial inserts reduced these values to 1.95 and 27%, respectively, while the screw-type structure provided the most uniform distribution, with corresponding values of 1.75 and 20%. Particle-velocity fields indicated that the guiding elements promoted a more even particle supply to the four tubes. The results demonstrate that inlet-flow conditioning is essential for the effective aerodynamic utilization of the enlarged collecting area in multi-tube ESPs.
- Open Access
- 24 April 2026
- Published by University of Zilina in Communications - Scientific letters of the University of Zilina
- Vol. 28 (2) , B43-B51
Optimizing Combustion Process: The Impact of Flame Zone Air Supply on Emissions and Performance in Pellet Boiler
Biomass combustion is a widely used renewable option for a small-scale heat and power, but incomplete burnout and pollutant formation remain challenges in boilers without optimized air staging. In this study, is investigated how controlled tra...
- 24 April 2026
- Published by University of Zilina in Communications - Scientific letters of the University of Zilina
- Vol. 28 (2) , B43-B51
Open AccessOptimizing Combustion Process: The Impact of Flame Zone Air Supply on Emissions and Performance in Pellet Boiler
Biomass combustion is a widely used renewable option for a small-scale heat and power, but incomplete burnout and pollutant formation remain challenges in boilers without optimized air staging. In this study, is investigated how controlled tra...
- 1 April 2026
- Published by Springer Nature
- p. 169-187
Advanced Emission Control and Efficiency Enhancement in Biomass Boilers Using MATLAB-Based Machine Learning
- 1 April 2026
- Published by Springer Nature
- p. 169-187
Advanced Emission Control and Efficiency Enhancement in Biomass Boilers Using MATLAB-Based Machine Learning
- 1 April 2026
- Published by Springer Nature
- p. 157-166
Prediction of Particulate Matter from Combustion Based on Neural Network
- 1 April 2026
- Published by Springer Nature
- p. 157-166
Prediction of Particulate Matter from Combustion Based on Neural Network
- Open Access
- 17 March 2026
- Published by Springer Nature in Biomass Conversion and Biorefinery
- Vol. 16 (6) , 181
Operation of four-tube electrostatic precipitator during pellet combustion in small-scale heat source under varying inlet air mass flow rate
This article experimentally evaluates how inlet air mass flow rate affects heat output, gaseous emissions, particulate matter (PM), and the collection efficiency of a four-tube electrostatic precipitator (ESP) installed downstream of an automatic pellet boiler. Measurements were conducted at five fan settings corresponding to inlet air mass flow rates of 89.18–143.64 kg·h⁻¹, with the ESP mode (ON/OFF). Increasing air mass flow caused a slight reduction in heat output (from 8.6 to 9.9 kW for ESP-OFF and 8.6–10.3 kW for ESP-ON) and a strong increase in CO at 10% O₂ (from 609 to 1512 mg·m⁻³ for ESP-OFF and 494–1670 mg·m⁻³ for ESP-ON), while NOₓ at 10% O₂ remained within a narrow range (128–146 mg·m⁻³ for ESP-OFF; 128–145 mg·m⁻³ for ESP-ON). The ESP mode (ON/OFF) had no measurable influence on heat output, CO, or NOₓ trends. During ESP-OFF mode, total PM showed a nonlinear dependence on air supply and reached a maximum at fan setting 4 (total PM concentration at 10% O₂ was 21.35–28.77 mg·m⁻³). During ESP-ON mode, total PM at 10% O₂ decreased to 2.34–4.85 mg·m⁻³, yielding overall collection efficiencies of 81.48–91.24%, with the maximum efficiency (91.24%) at 128.92 kg·h⁻¹ (fan setting 4). Quadratic regression captured strong dependencies of heat output on airflow (R² = 0.88–0.98), CO (R² ≈ 1), and NOₓ (R² = 0.93–0.99). The results demonstrate that the four-tube ESP provides high PM reduction (> 80%) under varying air-supply conditions without systematically altering heat output or gaseous emissions trends.
- 17 March 2026
- Published by Springer Nature in Biomass Conversion and Biorefinery
- Vol. 16 (6) , 181
Open AccessOperation of four-tube electrostatic precipitator during pellet combustion in small-scale heat source under varying inlet air mass flow rate
This article experimentally evaluates how inlet air mass flow rate affects heat output, gaseous emissions, particulate matter (PM), and the collection efficiency of a four-tube electrostatic precipitator (ESP) installed downstream of an automatic pellet boiler. Measurements were conducted at five fan settings corresponding to inlet air mass flow rates of 89.18–143.64 kg·h⁻¹, with the ESP mode (ON/OFF). Increasing air mass flow caused a slight reduction in heat output (from 8.6 to 9.9 kW for ESP-OFF and 8.6–10.3 kW for ESP-ON) and a strong increase in CO at 10% O₂ (from 609 to 1512 mg·m⁻³ for ESP-OFF and 494–1670 mg·m⁻³ for ESP-ON), while NOₓ at 10% O₂ remained within a narrow range (128–146 mg·m⁻³ for ESP-OFF; 128–145 mg·m⁻³ for ESP-ON). The ESP mode (ON/OFF) had no measurable influence on heat output, CO, or NOₓ trends. During ESP-OFF mode, total PM showed a nonlinear dependence on air supply and reached a maximum at fan setting 4 (total PM concentration at 10% O₂ was 21.35–28.77 mg·m⁻³). During ESP-ON mode, total PM at 10% O₂ decreased to 2.34–4.85 mg·m⁻³, yielding overall collection efficiencies of 81.48–91.24%, with the maximum efficiency (91.24%) at 128.92 kg·h⁻¹ (fan setting 4). Quadratic regression captured strong dependencies of heat output on airflow (R² = 0.88–0.98), CO (R² ≈ 1), and NOₓ (R² = 0.93–0.99). The results demonstrate that the four-tube ESP provides high PM reduction (> 80%) under varying air-supply conditions without systematically altering heat output or gaseous emissions trends.
- Open Access
- 7 November 2025
- Published by American Chemical Society (ACS) in ACS Omega
- Vol. 10 (45) , 55054-55062
Influence of Biomass Pellet Composition on Particulate Matter and Electrostatic Precipitator Efficiency
This study investigated the influence of fuel composition on particulate matter (PM) emissions and the efficiency of an electrostatic precipitator (ESP) during small-scale combustion. The research compared woody pellets (spruce, beech) with agro-pellets (straw, hay, sunflower). Elemental and X-ray fluorescence analyses showed that agro-pellets contained higher concentrations of ash-forming elements, including alkali metals, Cl, and Si, which led to the formation of fine fly ash and increased deposition on ESP walls. Combustion tests demonstrated that agro-pellets generated substantially higher PM concentrations in ESP-OFF conditions, with summary values of 672.4 mg·m-3 for hay, 368.3 mg·m-3 for straw, and 395.5 mg·m-3 for sunflower. In contrast, woody pellets produced considerably lower emissions, measured at 76.3 mg·m-3 for beech and 32.4 mg·m-3 for spruce. The application of the ESP achieved high removal efficiencies across all fuels, ranging from 81% for hay to nearly 93% for spruce, with the most significant relative reductions observed in the fine PM fraction. Analyzed PM by X-ray fluorescence spectrometry after combustion of agro-pellets contained significantly higher concentrations of K, Cl, Na, and S, whereas PM after combustion of wood pellets exhibited comparatively lower levels of these elements. Other inorganic elements detected in the PM composition included Si, Ca, Mg, Mn, Fe, and P.
- 7 November 2025
- Published by American Chemical Society (ACS) in ACS Omega
- Vol. 10 (45) , 55054-55062
Open AccessInfluence of Biomass Pellet Composition on Particulate Matter and Electrostatic Precipitator Efficiency
This study investigated the influence of fuel composition on particulate matter (PM) emissions and the efficiency of an electrostatic precipitator (ESP) during small-scale combustion. The research compared woody pellets (spruce, beech) with agro-pellets (straw, hay, sunflower). Elemental and X-ray fluorescence analyses showed that agro-pellets contained higher concentrations of ash-forming elements, including alkali metals, Cl, and Si, which led to the formation of fine fly ash and increased deposition on ESP walls. Combustion tests demonstrated that agro-pellets generated substantially higher PM concentrations in ESP-OFF conditions, with summary values of 672.4 mg·m-3 for hay, 368.3 mg·m-3 for straw, and 395.5 mg·m-3 for sunflower. In contrast, woody pellets produced considerably lower emissions, measured at 76.3 mg·m-3 for beech and 32.4 mg·m-3 for spruce. The application of the ESP achieved high removal efficiencies across all fuels, ranging from 81% for hay to nearly 93% for spruce, with the most significant relative reductions observed in the fine PM fraction. Analyzed PM by X-ray fluorescence spectrometry after combustion of agro-pellets contained significantly higher concentrations of K, Cl, Na, and S, whereas PM after combustion of wood pellets exhibited comparatively lower levels of these elements. Other inorganic elements detected in the PM composition included Si, Ca, Mg, Mn, Fe, and P.
- Open Access
- 5 September 2025
- Published by EDP Sciences in MATEC Web of Conferences
- Vol. 412, 05002
Effect of Duct Extension on Velocity Profile in a Multi-Tube Electrostatic Precipitator
Electrostatic precipitators are widely used for the removal of particulate matter from flue gases due to their high collection efficiency. In this study, a computational fluid dynamics approach was employed to analyse the influence of an upstream duct extension on the velocity distribution within a four-tube precipitator. Compared to a standard single- tube configuration, the multi-tube arrangement provides a 60% increase in collection area. However, this benefit introduces challenges in uniform flow across all tubes. Two configurations were examined: a baseline case without extension (Case 1) and a modified version incorporating a 500 mm duct extension before the ESP section (Case 2) for improving flow uniformity. Simulation results revealed that Case 1 exhibited significant velocity asymmetry, with two tubes carrying most of the flow. Case 2 demonstrated substantially improved flow uniformity, with more balanced velocities across all tubes. These findings highlight the importance of flow- conditioning measures in optimizing the electrostatic precipitator. Although the duct extension proved effective, its integration may be limited by spatial constraints in small-scale systems, prompting future investigation into compact alternatives such as internal deflectors or straighteners.
- 5 September 2025
- Published by EDP Sciences in MATEC Web of Conferences
- Vol. 412, 05002
Open AccessEffect of Duct Extension on Velocity Profile in a Multi-Tube Electrostatic Precipitator
Electrostatic precipitators are widely used for the removal of particulate matter from flue gases due to their high collection efficiency. In this study, a computational fluid dynamics approach was employed to analyse the influence of an upstream duct extension on the velocity distribution within a four-tube precipitator. Compared to a standard single- tube configuration, the multi-tube arrangement provides a 60% increase in collection area. However, this benefit introduces challenges in uniform flow across all tubes. Two configurations were examined: a baseline case without extension (Case 1) and a modified version incorporating a 500 mm duct extension before the ESP section (Case 2) for improving flow uniformity. Simulation results revealed that Case 1 exhibited significant velocity asymmetry, with two tubes carrying most of the flow. Case 2 demonstrated substantially improved flow uniformity, with more balanced velocities across all tubes. These findings highlight the importance of flow- conditioning measures in optimizing the electrostatic precipitator. Although the duct extension proved effective, its integration may be limited by spatial constraints in small-scale systems, prompting future investigation into compact alternatives such as internal deflectors or straighteners.
- Open Access
- 15 August 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 13, 147397-147407
Investigation of a Multi-Tube ESP: CFD-Based Electric Field and Efficiency Decrease During Long-Term Operation
This study focuses on the development, simulation, and experimental validation of a multi-tube electrostatic precipitator (ESP) designed for small-scale heat source applications. Using computational fluid dynamics (CFD), the particle mass concentration and electric field distribution were simulated to determine key operational parameters, including the onset voltage for corona discharge. ESP efficiency was evaluated through gravimetric measurements of particulate matter (PM) concentrations during short-term and long-term operations. Short-term tests at a supply voltage of 8.7 kV demonstrated an average PM capture efficiency of around 84%. In long-term operation, with an increased voltage of 12.5 kV, the ESP initially achieved efficiencies close to 90%. However, a gradual decline in performance was observed, with efficiency dropping to approximately 82% after 33 hours of continuous operation. The efficiency decrease was attributed to the accumulation of PM on the collection surfaces, which led to reduced electrostatic field strength and diminished particle capture capability. These results emphasize the necessity of regular cleaning to maintain high-efficiency operation, especially in extended-use scenarios. When properly maintained, the multi-tube ESP used in this work has the potential to reach high efficiency similar to existing small-scale ESP systems.
- 15 August 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 13, 147397-147407
Open AccessInvestigation of a Multi-Tube ESP: CFD-Based Electric Field and Efficiency Decrease During Long-Term Operation
This study focuses on the development, simulation, and experimental validation of a multi-tube electrostatic precipitator (ESP) designed for small-scale heat source applications. Using computational fluid dynamics (CFD), the particle mass concentration and electric field distribution were simulated to determine key operational parameters, including the onset voltage for corona discharge. ESP efficiency was evaluated through gravimetric measurements of particulate matter (PM) concentrations during short-term and long-term operations. Short-term tests at a supply voltage of 8.7 kV demonstrated an average PM capture efficiency of around 84%. In long-term operation, with an increased voltage of 12.5 kV, the ESP initially achieved efficiencies close to 90%. However, a gradual decline in performance was observed, with efficiency dropping to approximately 82% after 33 hours of continuous operation. The efficiency decrease was attributed to the accumulation of PM on the collection surfaces, which led to reduced electrostatic field strength and diminished particle capture capability. These results emphasize the necessity of regular cleaning to maintain high-efficiency operation, especially in extended-use scenarios. When properly maintained, the multi-tube ESP used in this work has the potential to reach high efficiency similar to existing small-scale ESP systems.
- Open Access
- 21 July 2025
- Published by Elsevier in Case Studies in Thermal Engineering
- Vol. 73
Increasing electrostatic precipitator efficiency by implementing a flow straightener in the flue gas pipe: CFD simulations and experimental study
- 21 July 2025
- Published by Elsevier in Case Studies in Thermal Engineering
- Vol. 73
Open AccessIncreasing electrostatic precipitator efficiency by implementing a flow straightener in the flue gas pipe: CFD simulations and experimental study