Francesco Bertelli
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Francesco Bertelli has a total of 21 co-authors. Here are the top co-authors by number of shared publications:
- Vladimiro L. Vida
Pediatric and Congenital Cardiac Surgery Unit, Department of Cardiac, Thoracic, Vascular Sciences and Public Health, University of Padua, Padua, Italy
4 shared publications Charlotte Godard
Decision and Bayesian Computation, Computation Biology Department, CNRS, URS 3756, Neuroscience Department, CNRS UMR 3571, Institut Pasteur, Paris, France
2 shared publicationsClaudia Cattapan
Pediatric and Congenital Cardiac Surgery Unit, University of Padua , Italy
2 shared publications- Jean-Baptiste Masson
Institut Pasteur, Université Paris Cité, CNRS UMR 3571, Decision and Bayesian Computation, Paris, France
2 shared publications Mohamed El Beheiry
Decision and Bayesian Computation, Computation Biology Department, CNRS, URS 3756, Neuroscience Department, CNRS UMR 3571, Institut Pasteur, Paris, France
2 shared publicationsNathalie Boddaert
Pediatric Radiology Unit, Hôpital universitaire Necker-Enfants Malades, Université de Paris , France
2 shared publications
Latest Publications
- Open Access
- 19 October 2023
- Published by Wolters Kluwer Health in ASAIO Journal
- Vol. 70 (6) , e78-e81
Successful Implantation of HeartMate3 in a Small Child After Multimodality Imaging Pathway to Assess Feasibility
The current use of intracorporeal left ventricular assist devices in children is still limited by small body dimensions. Many children weighing of less than 30 kg requiring durable mechanical circulatory support are implanted with the Berlin Heart EXCOR, a paracorporeal device. We present the case of a girl aged 10 years with a body surface area of 1.01 m2 undergoing a safe and effective HeartMate3 implantation despite extremely small thoracic dimensions. Using computed tomography-derived three-dimensional (3D) reconstruction, it was possible to simulate several device positions finding the best HeartMate3 lodging. Simulation-guided pump placement was then obtained in the operating room. Normal HeartMate3 functioning was registered until heart transplant. Our experience shows that preoperative planning and virtual fitting simulation can be effective to assess safety of HeartMate3 implantation even in small children. The 3D reconstruction and simulation may help to increase the pool of children candidates for this device, even though a larger experience is needed to assess the risk profile of the HeartMate3 in such small patients.
- 19 October 2023
- Published by Wolters Kluwer Health in ASAIO Journal
- Vol. 70 (6) , e78-e81
Open AccessSuccessful Implantation of HeartMate3 in a Small Child After Multimodality Imaging Pathway to Assess Feasibility
The current use of intracorporeal left ventricular assist devices in children is still limited by small body dimensions. Many children weighing of less than 30 kg requiring durable mechanical circulatory support are implanted with the Berlin Heart EXCOR, a paracorporeal device. We present the case of a girl aged 10 years with a body surface area of 1.01 m2 undergoing a safe and effective HeartMate3 implantation despite extremely small thoracic dimensions. Using computed tomography-derived three-dimensional (3D) reconstruction, it was possible to simulate several device positions finding the best HeartMate3 lodging. Simulation-guided pump placement was then obtained in the operating room. Normal HeartMate3 functioning was registered until heart transplant. Our experience shows that preoperative planning and virtual fitting simulation can be effective to assess safety of HeartMate3 implantation even in small children. The 3D reconstruction and simulation may help to increase the pool of children candidates for this device, even though a larger experience is needed to assess the risk profile of the HeartMate3 in such small patients.
- Open Access
- 1 June 2023
- Published by Oxford University Press (OUP) in Interdisciplinary CardioVascular and Thoracic Surgery
- Vol. 36 (6)
Fast-track virtual reality software to facilitate 3-dimensional reconstruction in congenital heart disease
OBJECTIVES: Two limitations of the clinical use of 3-dimensional (3D) reconstruction and virtual reality systems are the relatively high cost and the amount of experience required to use hardware and software to effectively explore medical images. We have tried to simplify the process and validate a new tool developed for this purpose with a novel software package. METHODS: Five patients with right partial anomalous pulmonary venous return with adequate preoperative images acquired with magnetic resonance imaging were enrolled. Five volunteers with no previous experience in the field of 3D reconstruction were instructed to use the software after viewing a short video tutorial. Users were then asked to create a 3D model of each patient's heart using DIVA software. Their results were compared quantitatively and qualitatively with a benchmark reconstruction performed by an experienced user. RESULTS: All our participants recreated 3D models in a relatively short time, maintaining a good overall quality (average quality score ≥ 3 on a scale of 1–5). The overall trend of all the parameters analysed showed a statistical improvement between case 1 and case 5, as users became more and more experienced. CONCLUSIONS: DIVA is a simple software program that allows accurate 3D reconstruction in a relatively short time (“fast-track” virtual reality). In this study, we demonstrated the potential use of DIVA by inexperienced users, with a significant improvement in quality and time after a few cases were performed. Further studies are needed to confirm the potential application of this technology on a larger scale.
- 1 June 2023
- Published by Oxford University Press (OUP) in Interdisciplinary CardioVascular and Thoracic Surgery
- Vol. 36 (6)
Open AccessFast-track virtual reality software to facilitate 3-dimensional reconstruction in congenital heart disease
OBJECTIVES: Two limitations of the clinical use of 3-dimensional (3D) reconstruction and virtual reality systems are the relatively high cost and the amount of experience required to use hardware and software to effectively explore medical images. We have tried to simplify the process and validate a new tool developed for this purpose with a novel software package. METHODS: Five patients with right partial anomalous pulmonary venous return with adequate preoperative images acquired with magnetic resonance imaging were enrolled. Five volunteers with no previous experience in the field of 3D reconstruction were instructed to use the software after viewing a short video tutorial. Users were then asked to create a 3D model of each patient's heart using DIVA software. Their results were compared quantitatively and qualitatively with a benchmark reconstruction performed by an experienced user. RESULTS: All our participants recreated 3D models in a relatively short time, maintaining a good overall quality (average quality score ≥ 3 on a scale of 1–5). The overall trend of all the parameters analysed showed a statistical improvement between case 1 and case 5, as users became more and more experienced. CONCLUSIONS: DIVA is a simple software program that allows accurate 3D reconstruction in a relatively short time (“fast-track” virtual reality). In this study, we demonstrated the potential use of DIVA by inexperienced users, with a significant improvement in quality and time after a few cases were performed. Further studies are needed to confirm the potential application of this technology on a larger scale.
- 1 June 2021
- Published by Elsevier in Revista Espanola de Cardiologia
- Vol. 74 (6) , 549-551
Reconstrucción cardiaca fetal basada en eco-3D: un protocolo piloto en asesoramiento prenatal
- 1 June 2021
- Published by Elsevier in Revista Espanola de Cardiologia
- Vol. 74 (6) , 549-551
Reconstrucción cardiaca fetal basada en eco-3D: un protocolo piloto en asesoramiento prenatal
- 24 March 2021
- Published by Wiley in Journal of Cardiac Surgery
- Vol. 36 (7) , 2598-2602
Fast‐track virtual reality for cardiac imaging in congenital heart disease
Background and Aim of the Study We sought to evaluate the appropriateness of cardiac anatomy renderings by a new virtual reality (VR) technology, entitled DIVA, directly applicable to raw magnetic resonance imaging (MRI) data without intermediate segmentation steps in comparison to standard three‐dimensional (3D) rendering techniques (3D PDF and 3D printing). Differences in post‐processing times were also evaluated. Methods We reconstructed 3D (STL, 3D‐PDF, and 3D printed ones) and VR models of three patients with different types of complex congenital heart disease (CHD). We then asked a senior pediatric heart surgeon to compare and grade the results obtained. Results All anatomical structures were well visualized in both VR and 3D PDF/printed models. Ventricular‐arterial connections and their relationship with the great vessels were better visualized with the VR model (Case 2); aortic arch anatomy and details were also better visualized by the VR model (Case 3). The median post‐processing time to get VR models using DIVA was 5 min in comparison to 8 h (range 8–12 h including printing time) for 3D models (PDF/printed). Conclusions VR directly applied to non‐segmented 3D‐MRI data set is a promising technique for 3D advanced modeling in CHD. It is systematically more consistent and faster when compared to standard 3D‐modeling techniques.
- 24 March 2021
- Published by Wiley in Journal of Cardiac Surgery
- Vol. 36 (7) , 2598-2602
Fast‐track virtual reality for cardiac imaging in congenital heart disease
Background and Aim of the Study We sought to evaluate the appropriateness of cardiac anatomy renderings by a new virtual reality (VR) technology, entitled DIVA, directly applicable to raw magnetic resonance imaging (MRI) data without intermediate segmentation steps in comparison to standard three‐dimensional (3D) rendering techniques (3D PDF and 3D printing). Differences in post‐processing times were also evaluated. Methods We reconstructed 3D (STL, 3D‐PDF, and 3D printed ones) and VR models of three patients with different types of complex congenital heart disease (CHD). We then asked a senior pediatric heart surgeon to compare and grade the results obtained. Results All anatomical structures were well visualized in both VR and 3D PDF/printed models. Ventricular‐arterial connections and their relationship with the great vessels were better visualized with the VR model (Case 2); aortic arch anatomy and details were also better visualized by the VR model (Case 3). The median post‐processing time to get VR models using DIVA was 5 min in comparison to 8 h (range 8–12 h including printing time) for 3D models (PDF/printed). Conclusions VR directly applied to non‐segmented 3D‐MRI data set is a promising technique for 3D advanced modeling in CHD. It is systematically more consistent and faster when compared to standard 3D‐modeling techniques.