Jeffrey J. Olson
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Jeffrey J. Olson has a total of 92 co-authors. Here are the top co-authors by number of shared publications:
- Jay D. Keener
Department of Orthopaedic Surgery, Washington University in St. Louis, St. Louis, Missouri
7 shared publications - Jeffrey Ryan Hill
Department of Orthopaedic Surgery, University of Arkansas for Medical Sciences, Little Rock, AR, USA
7 shared publications - Alexander William Aleem
Department of Orthopaedic Surgery, Washington University in St. Louis, St. Louis, Missouri
5 shared publications - Benjamin Zmistowski
Department of Orthopaedic Surgery, Washington University in St. Louis, St. Louis, Missouri
5 shared publications Aidin Masoudi
Center for Advanced Orthopaedic Studies Department of Orthopaedic Surgery Beth Israel Deaconess Medical Center Harvard Medical School Boston Massachusetts U.S.A.
2 shared publicationsAra Nazarian
Center for Advanced Orthopaedic Studies Department of Orthopaedic Surgery Beth Israel Deaconess Medical Center Harvard Medical School Boston Massachusetts U.S.A.
2 shared publications
Latest Publications
- Open Access
- 13 January 2025
- Published by Elsevier in Seminars in Arthroplasty: JSES
- Vol. 35 (2) , 195-202
Functional deficiencies following reverse and anatomic total shoulder arthroplasty: detecting true differences
- 13 January 2025
- Published by Elsevier in Seminars in Arthroplasty: JSES
- Vol. 35 (2) , 195-202
Open AccessFunctional deficiencies following reverse and anatomic total shoulder arthroplasty: detecting true differences
- 31 August 2024
- Published by Elsevier in Journal of Shoulder and Elbow Surgery
- Vol. 34 (4) , 1043-1050
Midterm radiographic outcomes of anatomic total shoulder arthroplasty in biplanar glenoid deformities
- 31 August 2024
- Published by Elsevier in Journal of Shoulder and Elbow Surgery
- Vol. 34 (4) , 1043-1050
Midterm radiographic outcomes of anatomic total shoulder arthroplasty in biplanar glenoid deformities
- 1 August 2024
- Published by Wolters Kluwer Health in JBJS Reviews
- Vol. 12 (8)
Utility of Machine Learning, Natural Language Processing, and Artificial Intelligence in Predicting Hospital Readmissions After Orthopaedic Surgery
Background: Numerous applications and strategies have been utilized to help assess the trends and patterns of readmissions after orthopaedic surgery in an attempt to extrapolate possible risk factors and causative agents. The aim of this work is to systematically summarize the available literature on the extent to which natural language processing, machine learning, and artificial intelligence (AI) can help improve the predictability of hospital readmissions after orthopaedic and spine surgeries.Methods: This is a systematic review and meta-analysis. PubMed, Embase and Google Scholar were searched, up until August 30, 2023, for studies that explore the use of AI, natural language processing, and machine learning tools for the prediction of readmission rates after orthopedic procedures. Data regarding surgery type, patient population, readmission outcomes, advanced models utilized, comparison methods, predictor sets, the inclusion of perioperative predictors, validation method, size of training and testing sample, accuracy, and receiver operating characteristics (C-statistic), among other factors, were extracted and assessed.Results: A total of 26 studies were included in our final dataset. The overall summary C-statistic showed a mean of 0.71 across all models, indicating a reasonable level of predictiveness. A total of 15 articles (57%) were attributed to the spine, making it the most commonly explored orthopaedic field in our study. When comparing accuracy of prediction models between different fields, models predicting readmissions after hip/knee arthroplasty procedures had a higher prediction accuracy (mean C-statistic = 0.79) than spine (mean C-statistic = 0.7) and shoulder (mean C-statistic = 0.67). In addition, models that used single institution data, and those that included intraoperative and/or postoperative outcomes, had a higher mean C-statistic than those utilizing other data sources, and that include only preoperative predictors. According to the Prediction model Risk of Bias Assessment Tool, the majority of the articles in our study had a high risk of bias.Conclusion: AI tools perform reasonably well in predicting readmissions after orthopaedic procedures. Future work should focus on standardizing study methodologies and designs, and improving the data analysis process, in an attempt to produce more reliable and tangible results.Level of Evidence: Level III. See Instructions for Authors for a complete description of levels of evidence.
- 1 August 2024
- Published by Wolters Kluwer Health in JBJS Reviews
- Vol. 12 (8)
Utility of Machine Learning, Natural Language Processing, and Artificial Intelligence in Predicting Hospital Readmissions After Orthopaedic Surgery
Background: Numerous applications and strategies have been utilized to help assess the trends and patterns of readmissions after orthopaedic surgery in an attempt to extrapolate possible risk factors and causative agents. The aim of this work is to systematically summarize the available literature on the extent to which natural language processing, machine learning, and artificial intelligence (AI) can help improve the predictability of hospital readmissions after orthopaedic and spine surgeries.Methods: This is a systematic review and meta-analysis. PubMed, Embase and Google Scholar were searched, up until August 30, 2023, for studies that explore the use of AI, natural language processing, and machine learning tools for the prediction of readmission rates after orthopedic procedures. Data regarding surgery type, patient population, readmission outcomes, advanced models utilized, comparison methods, predictor sets, the inclusion of perioperative predictors, validation method, size of training and testing sample, accuracy, and receiver operating characteristics (C-statistic), among other factors, were extracted and assessed.Results: A total of 26 studies were included in our final dataset. The overall summary C-statistic showed a mean of 0.71 across all models, indicating a reasonable level of predictiveness. A total of 15 articles (57%) were attributed to the spine, making it the most commonly explored orthopaedic field in our study. When comparing accuracy of prediction models between different fields, models predicting readmissions after hip/knee arthroplasty procedures had a higher prediction accuracy (mean C-statistic = 0.79) than spine (mean C-statistic = 0.7) and shoulder (mean C-statistic = 0.67). In addition, models that used single institution data, and those that included intraoperative and/or postoperative outcomes, had a higher mean C-statistic than those utilizing other data sources, and that include only preoperative predictors. According to the Prediction model Risk of Bias Assessment Tool, the majority of the articles in our study had a high risk of bias.Conclusion: AI tools perform reasonably well in predicting readmissions after orthopaedic procedures. Future work should focus on standardizing study methodologies and designs, and improving the data analysis process, in an attempt to produce more reliable and tangible results.Level of Evidence: Level III. See Instructions for Authors for a complete description of levels of evidence.
- 30 July 2024
- Published by Elsevier in Journal of Shoulder and Elbow Surgery
- Vol. 34 (2) , 430-440
Does surgical intervention alter the natural history of degenerative rotator cuff tears? Comparative analysis from a prospective longitudinal study
- 30 July 2024
- Published by Elsevier in Journal of Shoulder and Elbow Surgery
- Vol. 34 (2) , 430-440
Does surgical intervention alter the natural history of degenerative rotator cuff tears? Comparative analysis from a prospective longitudinal study
- 14 June 2024
- Published by Wolters Kluwer Health in Journal of Bone and Joint Surgery
- Vol. 106 (15) , 1395-1403
Incidence of and Risk Factors for Reoperation and Revision Following Total Elbow Arthroplasty with an Anatomic Convertible Prosthesis
Background: Total elbow arthroplasty (TEA) remains a valuable tool for treating inflammatory, degenerative, and traumatic elbow conditions. This study aimed to understand the incidence of and risk factors for reoperation following TEA at a high-volume center utilizing an implant with a convertible linkage and the potential for anatomic lateral column reconstruction. Methods: All patients undergoing primary TEA with the Latitude prosthesis (Stryker) from July 2001 to May 2020 were identified. Patient characteristics, the surgical indication, and implant characteristics were obtained. Additionally, the indications and timing were identified for reoperations. Postoperative radiographs were analyzed to assess cement quality, implant position, lateral column reconstruction, and distal humeral bone loss. Results: Two hundred and nineteen TEAs were performed in 206 patients; 162 (74.0%) were in female patients, the mean patient age was 61 years (range, 23 to 95 years), and the mean follow-up was 11.8 years (range, 2 to 21 years). The most common indication for surgery was sequelae of trauma (36%). Ninety elbows (41.1%) required 200 reoperations at a mean of 19.6 months. Forty TEAs (18.3%) required revision of nonmodular implants, with 14 (6.4%) undergoing definitive explantation. The 5 and 10-year survivorship was 86.1% and 79.7%, respectively. The most common of the reasons for revision was aseptic loosening (53.8%), and the most common cause for non-revision reoperation was infection (23%). Younger age and greater follow-up duration were associated with greater revision and reoperation risks. Aseptic ulnar loosening was associated with a short ulnar stem length and component linkage (30% of short linked ulnar stems loosened; p < 0.001). Aseptic humeral loosening was associated with less-than-adequate cement-mantle quality (p = 0.04). Conclusions: Extended follow-up of the Latitude prosthesis at a high-volume center demonstrates that TEA continues to be hampered by a high reoperation rate, primarily due to infection and aseptic loosening. Technical factors such as good cement-mantle quality, longer stem length, and unlinked implants may play a role in preventing aseptic loosening. Further work is required to optimize long-term outcomes following TEA through improved understanding of appropriate surgical indications, techniques, and implant utilization. Level of Evidence: Therapeutic Level IV. See Instructions for Authors for a complete description of levels of evidence.
- 14 June 2024
- Published by Wolters Kluwer Health in Journal of Bone and Joint Surgery
- Vol. 106 (15) , 1395-1403
Incidence of and Risk Factors for Reoperation and Revision Following Total Elbow Arthroplasty with an Anatomic Convertible Prosthesis
Background: Total elbow arthroplasty (TEA) remains a valuable tool for treating inflammatory, degenerative, and traumatic elbow conditions. This study aimed to understand the incidence of and risk factors for reoperation following TEA at a high-volume center utilizing an implant with a convertible linkage and the potential for anatomic lateral column reconstruction. Methods: All patients undergoing primary TEA with the Latitude prosthesis (Stryker) from July 2001 to May 2020 were identified. Patient characteristics, the surgical indication, and implant characteristics were obtained. Additionally, the indications and timing were identified for reoperations. Postoperative radiographs were analyzed to assess cement quality, implant position, lateral column reconstruction, and distal humeral bone loss. Results: Two hundred and nineteen TEAs were performed in 206 patients; 162 (74.0%) were in female patients, the mean patient age was 61 years (range, 23 to 95 years), and the mean follow-up was 11.8 years (range, 2 to 21 years). The most common indication for surgery was sequelae of trauma (36%). Ninety elbows (41.1%) required 200 reoperations at a mean of 19.6 months. Forty TEAs (18.3%) required revision of nonmodular implants, with 14 (6.4%) undergoing definitive explantation. The 5 and 10-year survivorship was 86.1% and 79.7%, respectively. The most common of the reasons for revision was aseptic loosening (53.8%), and the most common cause for non-revision reoperation was infection (23%). Younger age and greater follow-up duration were associated with greater revision and reoperation risks. Aseptic ulnar loosening was associated with a short ulnar stem length and component linkage (30% of short linked ulnar stems loosened; p < 0.001). Aseptic humeral loosening was associated with less-than-adequate cement-mantle quality (p = 0.04). Conclusions: Extended follow-up of the Latitude prosthesis at a high-volume center demonstrates that TEA continues to be hampered by a high reoperation rate, primarily due to infection and aseptic loosening. Technical factors such as good cement-mantle quality, longer stem length, and unlinked implants may play a role in preventing aseptic loosening. Further work is required to optimize long-term outcomes following TEA through improved understanding of appropriate surgical indications, techniques, and implant utilization. Level of Evidence: Therapeutic Level IV. See Instructions for Authors for a complete description of levels of evidence.
- 28 February 2024
- Published by Elsevier in Journal of Shoulder and Elbow Surgery
- Vol. 33 (9) , 2048-2056
Three-dimensional analysis of biplanar glenoid deformities: what are they and can they be virtually reconstructed with anatomic total shoulder arthroplasty implants?
- 28 February 2024
- Published by Elsevier in Journal of Shoulder and Elbow Surgery
- Vol. 33 (9) , 2048-2056
Three-dimensional analysis of biplanar glenoid deformities: what are they and can they be virtually reconstructed with anatomic total shoulder arthroplasty implants?
- 28 August 2023
- Published by Elsevier in Journal of Shoulder and Elbow Surgery
- Vol. 33 (4) , 908-915
Revision of failed reverse total shoulder arthroplasty with reverse: short-term clinical outcomes
- 28 August 2023
- Published by Elsevier in Journal of Shoulder and Elbow Surgery
- Vol. 33 (4) , 908-915
Revision of failed reverse total shoulder arthroplasty with reverse: short-term clinical outcomes
- Open Access
- 30 March 2023
- Published by American Association for Cancer Research (AACR)
Supplementary Figures and Tables from Epidermal Growth Factor Receptor and PTEN Modulate Tissue Factor Expression in Glioblastoma through JunD/Activator Protein-1 Transcriptional Activity
Supplementary Figures and Tables from Epidermal Growth Factor Receptor and PTEN Modulate Tissue Factor Expression in Glioblastoma through JunD/Activator Protein-1 Transcriptional Activity
- 30 March 2023
- Published by American Association for Cancer Research (AACR)
Open AccessSupplementary Figures and Tables from Epidermal Growth Factor Receptor and PTEN Modulate Tissue Factor Expression in Glioblastoma through JunD/Activator Protein-1 Transcriptional Activity
Supplementary Figures and Tables from Epidermal Growth Factor Receptor and PTEN Modulate Tissue Factor Expression in Glioblastoma through JunD/Activator Protein-1 Transcriptional Activity