Ryoichi Saito
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Ryoichi Saito has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
- Takashi Mukaiyama
Institute of Science Tokyo
8 shared publications - Ami Shinjo
Graduate School of Engineering Science, Osaka University, 1-3 Machikaneyama, Toyonaka, Osaka 560-8531, Japan
1 shared publication Hiroaki Kotera
1 shared publication- K. Saito
Graduate School of Engineering Science, Osaka University 1 , 1-3 Machikaneyama, Toyonaka, Osaka 560-8531, Japan
1 shared publication - Kaoru Yamanouchi
The University of Tokyo
1 shared publication Kota Saito
Graduate School of Engineering Science, Osaka University 1 , 1-3 Machikaneyama, Toyonaka, Osaka 560-8531, Japan
1 shared publication
Latest Publications
- Open Access
- 1 November 2025
- Published by AIP Publishing in AIP Advances
- Vol. 15 (11)
Three-dimensional micromotion compensation protocols for an RF ion trap
We propose and demonstrate four procedures for three-dimensional micromotion compensation by combining two methods: the RF-photon correlation method and the displacement method based on trap RF amplitude modulation. In ion traps, the structure of the electrodes or the vacuum chamber may restrict the laser beam incidence direction, causing a limitation in the compensation scheme. We present four protocols, ensuring that at least one of them can be applied to experimental systems with various individual constraints. We also discuss the compensation accuracy and practical applicability of each of these four approaches. This work provides a practical guideline for performing full three-axis micromotion compensation and contributes to the advancement of endcap traps, which are highly suitable for single-ion trapping.
- 1 November 2025
- Published by AIP Publishing in AIP Advances
- Vol. 15 (11)
Open AccessThree-dimensional micromotion compensation protocols for an RF ion trap
We propose and demonstrate four procedures for three-dimensional micromotion compensation by combining two methods: the RF-photon correlation method and the displacement method based on trap RF amplitude modulation. In ion traps, the structure of the electrodes or the vacuum chamber may restrict the laser beam incidence direction, causing a limitation in the compensation scheme. We present four protocols, ensuring that at least one of them can be applied to experimental systems with various individual constraints. We also discuss the compensation accuracy and practical applicability of each of these four approaches. This work provides a practical guideline for performing full three-axis micromotion compensation and contributes to the advancement of endcap traps, which are highly suitable for single-ion trapping.
- 3 February 2025
- Published by American Physical Society (APS) in Physical Review A
- Vol. 111 (2)
Cancellation of phonon hopping in trapped ions by modulation of the trap potential
- 3 February 2025
- Published by American Physical Society (APS) in Physical Review A
- Vol. 111 (2)
Cancellation of phonon hopping in trapped ions by modulation of the trap potential
- 6 November 2024
- Published by Optica Publishing Group in Optics Express
- Vol. 32 (24) , 42616
Determination of principal axes orientation in an ion trap using matter-wave interference
We have developed a method for determining the orientations of the principal axes of an ion trap using an ion matter-wave interferometer. By examining the ion matter-wave interference signal induced by spin-dependent momentum kicks originating from stimulated Raman transitions, we can accurately ascertain the angles between the directions of these momentum kicks and the trap principal axes. The application of direct–current voltage to the ground electrodes, a common method adopted to finely tune trap frequencies in ion traps, leads to the trap principal axes rotating, a phenomenon that is yet to be reported quantatively. Our measurements successfully captured the rotation of the trap axes depending on the applied offset voltages. The findings of this study offer valuable insights into the functioning of ion traps for diverse quantum science and technology applications.
- 6 November 2024
- Published by Optica Publishing Group in Optics Express
- Vol. 32 (24) , 42616
Determination of principal axes orientation in an ion trap using matter-wave interference
We have developed a method for determining the orientations of the principal axes of an ion trap using an ion matter-wave interferometer. By examining the ion matter-wave interference signal induced by spin-dependent momentum kicks originating from stimulated Raman transitions, we can accurately ascertain the angles between the directions of these momentum kicks and the trap principal axes. The application of direct–current voltage to the ground electrodes, a common method adopted to finely tune trap frequencies in ion traps, leads to the trap principal axes rotating, a phenomenon that is yet to be reported quantatively. Our measurements successfully captured the rotation of the trap axes depending on the applied offset voltages. The findings of this study offer valuable insights into the functioning of ion traps for diverse quantum science and technology applications.
- Open Access
- 1 October 2024
- Published by American Physical Society (APS) in Physical Review Letters
- Vol. 133 (14) , 143402
Sensing Aharonov-Bohm Phase Using a Multiply-Orbiting-Ion Interferometer
Interferometers, which are built using spatially propagating light or matter waves, are commonly used to measure physical quantities. These measurements are made possible by exploiting the interference between waves traveling along different paths. This study introduces a novel approach to sensing of the Aharonov-Bohm phase, an ion matter-wave interferometer operating within a two-dimensional rotational trajectory in a trap potential. The ion orbitals in the nearly circular potential change rotation direction with time. This reversal of rotation direction results in a corresponding change in the interference phase. Our study is the first attempt to utilize propagating matter waves of an ion in constructing a two-dimensional interferometer for the measurement of physical quantities. Given that the scale factor of the interferometer to the cyclotron motion and the rotation of the system is common, the sensitivity to the Aharonov-Bohm phase in this study corresponds to a rotation sensitivity of approximately 300 rad / s . Besides advancing interferometry, our work also lays the foundation for future research into the use of ion matter waves in gyroscopic applications. Published by the American Physical Society 2024
- 1 October 2024
- Published by American Physical Society (APS) in Physical Review Letters
- Vol. 133 (14) , 143402
Open AccessSensing Aharonov-Bohm Phase Using a Multiply-Orbiting-Ion Interferometer
Interferometers, which are built using spatially propagating light or matter waves, are commonly used to measure physical quantities. These measurements are made possible by exploiting the interference between waves traveling along different paths. This study introduces a novel approach to sensing of the Aharonov-Bohm phase, an ion matter-wave interferometer operating within a two-dimensional rotational trajectory in a trap potential. The ion orbitals in the nearly circular potential change rotation direction with time. This reversal of rotation direction results in a corresponding change in the interference phase. Our study is the first attempt to utilize propagating matter waves of an ion in constructing a two-dimensional interferometer for the measurement of physical quantities. Given that the scale factor of the interferometer to the cyclotron motion and the rotation of the system is common, the sensitivity to the Aharonov-Bohm phase in this study corresponds to a rotation sensitivity of approximately 300 rad / s . Besides advancing interferometry, our work also lays the foundation for future research into the use of ion matter waves in gyroscopic applications. Published by the American Physical Society 2024
- Open Access
- 1 September 2022
- Published by AIP Publishing in Journal of Applied Physics
- Vol. 132 (9) , 094401
Ion trap frequency measurement from fluorescence dynamics
In this paper, we propose and demonstrate a new method for measuring the trap frequency from the fluorescence dynamics of an ion, initiated using fast trap-center displacement. Here, we observe the coherently excited motion of an ion in a harmonic trap using time-resolved fluorescence detection. Furthermore, Fourier analysis of the ion fluorescence signal was used to determine the trap frequency of an ion with high precision and reproducibility. The results show that our proposed method can be an alternative way to determine trap frequencies in an ion trap experiment.
- 1 September 2022
- Published by AIP Publishing in Journal of Applied Physics
- Vol. 132 (9) , 094401
Open AccessIon trap frequency measurement from fluorescence dynamics
In this paper, we propose and demonstrate a new method for measuring the trap frequency from the fluorescence dynamics of an ion, initiated using fast trap-center displacement. Here, we observe the coherently excited motion of an ion in a harmonic trap using time-resolved fluorescence detection. Furthermore, Fourier analysis of the ion fluorescence signal was used to determine the trap frequency of an ion with high precision and reproducibility. The results show that our proposed method can be an alternative way to determine trap frequencies in an ion trap experiment.
- 19 November 2021
- Published by American Physical Society (APS) in Physical Review A
- Vol. 104 (5) , 053114
Generation of a single-ion large oscillator
We demonstrate the generation of a trapped ion oscillator with a scale of via fast trap center displacement. Applying an offset voltage to the ion trap electrode helps achieve a displacement of the trap center within the timescale of 5 ns. The fluorescence dynamics of the ion is analyzed after the displacement to estimate the oscillation amplitude. The realized trap displacement is seven times larger than that achieved in previous work. Thus, this result is an important step toward the realization of a gyroscope using a single trapped ion.- 19 November 2021
- Published by American Physical Society (APS) in Physical Review A
- Vol. 104 (5) , 053114
Generation of a single-ion large oscillator
We demonstrate the generation of a trapped ion oscillator with a scale of via fast trap center displacement. Applying an offset voltage to the ion trap electrode helps achieve a displacement of the trap center within the timescale of 5 ns. The fluorescence dynamics of the ion is analyzed after the displacement to estimate the oscillation amplitude. The realized trap displacement is seven times larger than that achieved in previous work. Thus, this result is an important step toward the realization of a gyroscope using a single trapped ion.- 16 April 2021
- Published by American Physical Society (APS) in Physical Review Letters
- Vol. 126 (15) , 153604
Three-Dimensional Matter-Wave Interferometry of a Trapped Single Ion
We report on a demonstration of Ramsey interferometry by three-dimensional motion with a trapped ion. We applied a momentum kick to the ion in a direction diagonal to the trap axes to initiate three-dimensional motion using a mode-locked pulse laser. The interference signal was analyzed theoretically to demonstrate three-dimensional matter-wave interference. This work paves the way to realizing matter-wave interferometry using trapped ions.- 16 April 2021
- Published by American Physical Society (APS) in Physical Review Letters
- Vol. 126 (15) , 153604
Three-Dimensional Matter-Wave Interferometry of a Trapped Single Ion
We report on a demonstration of Ramsey interferometry by three-dimensional motion with a trapped ion. We applied a momentum kick to the ion in a direction diagonal to the trap axes to initiate three-dimensional motion using a mode-locked pulse laser. The interference signal was analyzed theoretically to demonstrate three-dimensional matter-wave interference. This work paves the way to realizing matter-wave interferometry using trapped ions.- Open Access
- 25 March 2021
- Published by AIP Publishing in Journal of Applied Physics
- Vol. 129 (12) , 124302
Measurement of ion displacement via RF power variation for excess micromotion compensation
We demonstrate a method of micromotion minimization of a trapped ion in a linear Paul trap based on the precision measurement of the ion trapping position displacement due to a stray electric field in the radial plane by ion fluorescence imaging. The amount of displacement in the radial plane is proportional to the strength of a stray electric field. Therefore, we evaluated the micromotion compensation condition by measuring the ion displacements from the ion equilibrium position using two different radial trap frequencies with various combinations of the compensation voltage. The residual electric field uncertainty of this technique reached a few volts per meter. This compensation technique does not depend on the orientation of the incident cooling laser or the detuning and imaging direction. Therefore, this method is suitable for a planar ion trap, a stylus ion trap, which limits the propagation angle of lasers, or miniaturized ion trap systems for sensing and metrological applications.
- 25 March 2021
- Published by AIP Publishing in Journal of Applied Physics
- Vol. 129 (12) , 124302
Open AccessMeasurement of ion displacement via RF power variation for excess micromotion compensation
We demonstrate a method of micromotion minimization of a trapped ion in a linear Paul trap based on the precision measurement of the ion trapping position displacement due to a stray electric field in the radial plane by ion fluorescence imaging. The amount of displacement in the radial plane is proportional to the strength of a stray electric field. Therefore, we evaluated the micromotion compensation condition by measuring the ion displacements from the ion equilibrium position using two different radial trap frequencies with various combinations of the compensation voltage. The residual electric field uncertainty of this technique reached a few volts per meter. This compensation technique does not depend on the orientation of the incident cooling laser or the detuning and imaging direction. Therefore, this method is suitable for a planar ion trap, a stylus ion trap, which limits the propagation angle of lasers, or miniaturized ion trap systems for sensing and metrological applications.
- 1 May 2015
- Published by Elsevier in Atomic Data and Nuclear Data Tables
- Vol. 103-104, 4-49
Structure factors for tunneling ionization rates of diatomic molecules
- 1 May 2015
- Published by Elsevier in Atomic Data and Nuclear Data Tables
- Vol. 103-104, 4-49
Structure factors for tunneling ionization rates of diatomic molecules
- 1 January 2000
- Published by Society for Imaging Science & Technology in NIP & Digital Fabrication Conference
- Vol. 16 (1) , 566-569
Extraction of Image Gamut Surface and Calculation of its Volume
Communicating color gamut is very important in color research and application. In this paper, we propose a new method for calculating the gamut volume by rearranging the color values. The entire color space is firstly divided by hue angle _Hab and secondly by lightness angle _Langle where the steps (_Hab, _Langle) are decided in nonuniform to include the constant color samples in each segmented sector. The most out-side points from the center are extracted, and the gamut surface is constructed by each ordered points. While, triangles constructed by each ordered points are decided to be outward or inward. The inward side is assigned to a minus volume, and finally the entire gamut volume is calculated by summing up the individual volume of tetrahedron with selected color values. The proposed method enables to describe the three dimensional gamut surfaces of color devices and color images.
- 1 January 2000
- Published by Society for Imaging Science & Technology in NIP & Digital Fabrication Conference
- Vol. 16 (1) , 566-569
Extraction of Image Gamut Surface and Calculation of its Volume
Communicating color gamut is very important in color research and application. In this paper, we propose a new method for calculating the gamut volume by rearranging the color values. The entire color space is firstly divided by hue angle _Hab and secondly by lightness angle _Langle where the steps (_Hab, _Langle) are decided in nonuniform to include the constant color samples in each segmented sector. The most out-side points from the center are extracted, and the gamut surface is constructed by each ordered points. While, triangles constructed by each ordered points are decided to be outward or inward. The inward side is assigned to a minus volume, and finally the entire gamut volume is calculated by summing up the individual volume of tetrahedron with selected color values. The proposed method enables to describe the three dimensional gamut surfaces of color devices and color images.