Mevra Temel
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Mevra Temel has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
- Andrew Allan Johnson
School of Design and Creative Arts, Loughborough University, Loughborough, UK
6 shared publications - Alex Lloyd
Environmental Ergonomics Research Centre, Loughborough School of Design and Creative Arts, Loughborough University, Loughborough, UK
5 shared publications - Anna M. West
School of Design and Creative Arts, Loughborough University, Loughborough, UK
1 shared publication - Eleanor L. Scott
University of Leeds, United Kingdom
1 shared publication - George Havenith
Environmental Ergonomics Research Centre, Loughborough Design School, Loughborough University, Loughborough, LE11 3TU, United Kingdom
1 shared publication - Josh Timothy Arnold
Environmental Ergonomics Research Centre, Loughborough University, Loughborough, UNITED KINGDOM
1 shared publication
Latest Publications
- Open Access
- 30 October 2025
- Published by SAGE Publications in Textile Research Journal
- Vol. 96 (21-22) , 2225-2241
Evaluating the effects of design and manufacturing parameters on friction at the surrogate skin–3D-printed textile interface
Additive manufacturing (AM) is increasingly employed in the development of 3D-printed wearables, including medical wrist supports, textiles, and protective garments. While the general tribological behavior of 3D-printed components has been widely studied, limited research has focused on the friction behavior of 3D-printed wearables when in contact with human skin, which is a crucial factor for improving wearer comfort by minimizing local skin friction. This study, therefore, investigates the influence of material type, manufacturing technology, and print parameters of 3D-printed textiles on frictional behavior against skin. Specimens were fabricated using three AM technologies: material extrusion (MEX), vat photopolymerization (VATP), and powder bed fusion (PBF). Each technology employed various materials and print parameters, specifically layer thickness (ranging from 0.05 to 0.3 mm) and print orientations (horizontal and vertical). Friction was measured using a custom-built handheld device at the interface between 3D-printed specimens and two surrogate skin models: lorica (representing the dorsal forearm) and silicone (representing the chest). The results revealed that friction was significantly influenced by both layer thickness and print orientation. For MEX specimens, acrylonitrile butadiene styrene, acrylonitrile styrene acrylate, and polycarbonate showed the highest friction, while for VATP, durable resin resulted in the highest friction coefficient. In contrast, PBF specimens exhibited very similar frictional behavior. Regarding layer thickness, higher values consistently resulted in the highest friction coefficients, regardless of manufacturing method or material type. These findings provide valuable insights for designers and engineers seeking to optimize the comfort of 3D-printed wearables, guiding the selection of suitable AM processes and parameters for products intended for direct skin contact.
- 30 October 2025
- Published by SAGE Publications in Textile Research Journal
- Vol. 96 (21-22) , 2225-2241
Open AccessEvaluating the effects of design and manufacturing parameters on friction at the surrogate skin–3D-printed textile interface
Additive manufacturing (AM) is increasingly employed in the development of 3D-printed wearables, including medical wrist supports, textiles, and protective garments. While the general tribological behavior of 3D-printed components has been widely studied, limited research has focused on the friction behavior of 3D-printed wearables when in contact with human skin, which is a crucial factor for improving wearer comfort by minimizing local skin friction. This study, therefore, investigates the influence of material type, manufacturing technology, and print parameters of 3D-printed textiles on frictional behavior against skin. Specimens were fabricated using three AM technologies: material extrusion (MEX), vat photopolymerization (VATP), and powder bed fusion (PBF). Each technology employed various materials and print parameters, specifically layer thickness (ranging from 0.05 to 0.3 mm) and print orientations (horizontal and vertical). Friction was measured using a custom-built handheld device at the interface between 3D-printed specimens and two surrogate skin models: lorica (representing the dorsal forearm) and silicone (representing the chest). The results revealed that friction was significantly influenced by both layer thickness and print orientation. For MEX specimens, acrylonitrile butadiene styrene, acrylonitrile styrene acrylate, and polycarbonate showed the highest friction, while for VATP, durable resin resulted in the highest friction coefficient. In contrast, PBF specimens exhibited very similar frictional behavior. Regarding layer thickness, higher values consistently resulted in the highest friction coefficients, regardless of manufacturing method or material type. These findings provide valuable insights for designers and engineers seeking to optimize the comfort of 3D-printed wearables, guiding the selection of suitable AM processes and parameters for products intended for direct skin contact.
- Open Access
- 3 August 2024
- Published by Taylor & Francis in Ergonomics
- Vol. 68 (8) , 1222-1238
The impact of knitted linked seams on comfort and friction perception
Friction from knitted clothing can cause discomfort and skin issues, underscoring the importance of tactile comfort for wearers. Seamless knitted garments are assumed to be comfortable to wear, yet there is little understanding of their tactile comfort in comparison to linked seams - the most common form of knitted garment. This novel study examines the influence of a garments knitted structural architecture on clothing comfort and wearability by investigating skin friction and tactile perception across ten body regions in both male and female participants, using two commonly utilised materials and seam designs: cotton and merino wool with plain and linked seams. The impact of seam design and regional factors on skin friction and tactile perception was analysed, revealing varying levels across tested body regions. Removing seams exposed a greater surface area to skin contact, leading to higher perceived friction levels. As such, structural elements in knitted garments enhance wearer comfort.
- 3 August 2024
- Published by Taylor & Francis in Ergonomics
- Vol. 68 (8) , 1222-1238
Open AccessThe impact of knitted linked seams on comfort and friction perception
Friction from knitted clothing can cause discomfort and skin issues, underscoring the importance of tactile comfort for wearers. Seamless knitted garments are assumed to be comfortable to wear, yet there is little understanding of their tactile comfort in comparison to linked seams - the most common form of knitted garment. This novel study examines the influence of a garments knitted structural architecture on clothing comfort and wearability by investigating skin friction and tactile perception across ten body regions in both male and female participants, using two commonly utilised materials and seam designs: cotton and merino wool with plain and linked seams. The impact of seam design and regional factors on skin friction and tactile perception was analysed, revealing varying levels across tested body regions. Removing seams exposed a greater surface area to skin contact, leading to higher perceived friction levels. As such, structural elements in knitted garments enhance wearer comfort.
- Open Access
- 7 December 2022
- Published by Taylor & Francis in Ergonomics
- Vol. 66 (10) , 1449-1464
Body mapping of skin friction coefficient and tactile perception during the dynamic skin-textile interaction
The clothing fabric and skin interact continuously across the many regions on users` bodies during wear, which can lead to both physical skin damage and discomfort. Therefore, this investigation aimed to explore the regional differences in skin friction, tactile perception and sensitivity in both females and males during the skin-textile interaction. The static and dynamic friction coefficient and textile perception (texture, stickiness, pleasantness, and discomfort) were measured across the 36 selected testing body areas by using a friction measurement device. The results revealed there was a significant difference in skin friction, tactile perceptions, and sensitivity across the various body regions. The anterior neck had the highest skin friction in both females and males, and participants generally rated higher texture perception in their anterior aspects compared to posterior and lateral regions. There was no significant difference in skin friction, tactile perception ratings, and sensitivity between females and males. This study sought to examine regional variations in skin friction, tactile perception, and sensitivity during the skin-textile interaction. There was a significant difference in skin friction, tactile perceptions, and sensitivity across the various body regions and no significant sex effect on skin friction, tactile perception ratings, and sensitivity.
- 7 December 2022
- Published by Taylor & Francis in Ergonomics
- Vol. 66 (10) , 1449-1464
Open AccessBody mapping of skin friction coefficient and tactile perception during the dynamic skin-textile interaction
The clothing fabric and skin interact continuously across the many regions on users` bodies during wear, which can lead to both physical skin damage and discomfort. Therefore, this investigation aimed to explore the regional differences in skin friction, tactile perception and sensitivity in both females and males during the skin-textile interaction. The static and dynamic friction coefficient and textile perception (texture, stickiness, pleasantness, and discomfort) were measured across the 36 selected testing body areas by using a friction measurement device. The results revealed there was a significant difference in skin friction, tactile perceptions, and sensitivity across the various body regions. The anterior neck had the highest skin friction in both females and males, and participants generally rated higher texture perception in their anterior aspects compared to posterior and lateral regions. There was no significant difference in skin friction, tactile perception ratings, and sensitivity between females and males. This study sought to examine regional variations in skin friction, tactile perception, and sensitivity during the skin-textile interaction. There was a significant difference in skin friction, tactile perceptions, and sensitivity across the various body regions and no significant sex effect on skin friction, tactile perception ratings, and sensitivity.
- Open Access
- 31 January 2022
- Published by Springer Nature in Tribology Letters
- Vol. 70 (1) , 1-12
Evaluating the Repeatability of Friction Coefficient Measurements and Tactile Perceptions in Skin–Textile Interactions Across Body Regions
Measuring the friction between human skin and textiles is essential to preventing skin-related health problems and wearer discomfort. This study sought to evaluate the repeatability of friction coefficient measurements and tactile perceptions at various human body regions, using a recently developed portable friction measuring device. Using the device, a cotton textile was applied to six test locations. The friction coefficient and tactile perceptions were taken three times, at each test site. The repeatability of friction coefficient was excellent with ICC of 0.91 ± 0.05 for static and 0.91 ± 0.06 for dynamic friction coefficient, and tactile perception showed good to excellent repeatability. The friction coefficient and tactile perception significantly differed across the body regions (p = 0.008 and p = 0.003, respectively). The chest showed the highest static friction coefficient with 0.90 ± 0.19 and dynamic friction coefficient with 0.79 ± 0.20, whereas the dorsal forearm with static 0.31 ± 0.07 and dynamic 0.25 ± 0.05 was the lowest. The ratings of tactile perceptions were independent of friction coefficient when the changes in the coefficient of friction were induced by regional difference, and/or the range of the coefficient of friction values were small. Moreover, skin temperature and friction coefficient correlated positively, whilst cutaneous hydration and friction coefficient did not.
- 31 January 2022
- Published by Springer Nature in Tribology Letters
- Vol. 70 (1) , 1-12
Open AccessEvaluating the Repeatability of Friction Coefficient Measurements and Tactile Perceptions in Skin–Textile Interactions Across Body Regions
Measuring the friction between human skin and textiles is essential to preventing skin-related health problems and wearer discomfort. This study sought to evaluate the repeatability of friction coefficient measurements and tactile perceptions at various human body regions, using a recently developed portable friction measuring device. Using the device, a cotton textile was applied to six test locations. The friction coefficient and tactile perceptions were taken three times, at each test site. The repeatability of friction coefficient was excellent with ICC of 0.91 ± 0.05 for static and 0.91 ± 0.06 for dynamic friction coefficient, and tactile perception showed good to excellent repeatability. The friction coefficient and tactile perception significantly differed across the body regions (p = 0.008 and p = 0.003, respectively). The chest showed the highest static friction coefficient with 0.90 ± 0.19 and dynamic friction coefficient with 0.79 ± 0.20, whereas the dorsal forearm with static 0.31 ± 0.07 and dynamic 0.25 ± 0.05 was the lowest. The ratings of tactile perceptions were independent of friction coefficient when the changes in the coefficient of friction were induced by regional difference, and/or the range of the coefficient of friction values were small. Moreover, skin temperature and friction coefficient correlated positively, whilst cutaneous hydration and friction coefficient did not.
- Open Access
- 23 August 2021
- Published by Springer Nature in Tribology Letters
- Vol. 69 (4) , 1-10
Evaluating the Design and Repeatability of a Novel Device to Measure Friction of Mechanical Surrogate Skins in Contact with Cotton Textiles
The ability to measure the level of friction between the human skin and a given textile is critical across fashion and textiles sectors, not least for the development of sporting and protective clothing. A portable custom-made device capable of measuring friction during the skin-textile interaction across often difficult or impossible to investigate body regions with objective repeatability has been established. The friction between a pre-shrunk 100% cotton textile and a quantity of four control surfaces (transparent and patterned polycarbonate plastic, and silicon and lorica surrogate skin) was measured three times per day across five consecutive days. The results clearly demonstrated that the novel friction test device had an excellent repeatability of 0.94 and 0.93 intraclass corelation coefficient for static and dynamic friction coefficient measurement, respectively. The silicon surrogate skin control surface produced the highest friction coefficient, while the pattered polycarbonate plate demonstrated the lowest friction coefficient, suggesting that the physical features of the control surface material influenced the recorded coefficient of friction. It was also revealed that the relationship between the static and dynamic friction coefficient is dependent on the surface material.
- 23 August 2021
- Published by Springer Nature in Tribology Letters
- Vol. 69 (4) , 1-10
Open AccessEvaluating the Design and Repeatability of a Novel Device to Measure Friction of Mechanical Surrogate Skins in Contact with Cotton Textiles
The ability to measure the level of friction between the human skin and a given textile is critical across fashion and textiles sectors, not least for the development of sporting and protective clothing. A portable custom-made device capable of measuring friction during the skin-textile interaction across often difficult or impossible to investigate body regions with objective repeatability has been established. The friction between a pre-shrunk 100% cotton textile and a quantity of four control surfaces (transparent and patterned polycarbonate plastic, and silicon and lorica surrogate skin) was measured three times per day across five consecutive days. The results clearly demonstrated that the novel friction test device had an excellent repeatability of 0.94 and 0.93 intraclass corelation coefficient for static and dynamic friction coefficient measurement, respectively. The silicon surrogate skin control surface produced the highest friction coefficient, while the pattered polycarbonate plate demonstrated the lowest friction coefficient, suggesting that the physical features of the control surface material influenced the recorded coefficient of friction. It was also revealed that the relationship between the static and dynamic friction coefficient is dependent on the surface material.
- Open Access
- 25 March 2021
- Published by Springer Nature in European Journal of Applied Physiology
- Vol. 121 (7) , 1943-1954
An examination of five theoretical foundations associated with localized thermosensory testing
Purpose: To assess five theoretical foundations underlying thermosensory testing using local thermal stimuli. Methods: Thermal sensation, discomfort and the confidence of thermal sensation scores were measured in 9 female and 8 male volunteers in response to 17 physical contact temperature stimuli, ranging between 18–42 °C. These were applied to their dorsal forearm and lateral torso, across two sessions. Results: Thermal sensation to physical temperature relationships followed a positive linear and sigmoidal fit at both forearm (r2 = 0.91/r2 = 0.91, respectively) and lateral torso (r2 = 0.90/ r2 = 0.91, respectively). Thermal discomfort to physical temperature relationships followed second and third-order fits at both forearm (r2 = 0.33/r2 = 0.34, respectively) and lateral torso (r2 = 0.38/r2 = 0.39, respectively) test sites. There were no sex-related or regional site differences in thermal sensation and discomfort across a wide range of physical contact temperatures. The median confidence of an individual’s thermal sensation rating was measured at 86%. Conclusion: The relation between thermal sensation and physical contact temperature was well described by both linear and sigmoidal models, i.e., the distance between the thermal sensation anchors is close to equal in terms of physical temperatures changes for the range studied. Participants rated similar thermal discomfort level in both cold and hot thermal stimuli for a given increase or decrease in physical contact temperature or thermal sensation. The confidence of thermal sensation rating did not depend on physical contact temperature.
- 25 March 2021
- Published by Springer Nature in European Journal of Applied Physiology
- Vol. 121 (7) , 1943-1954
Open AccessAn examination of five theoretical foundations associated with localized thermosensory testing
Purpose: To assess five theoretical foundations underlying thermosensory testing using local thermal stimuli. Methods: Thermal sensation, discomfort and the confidence of thermal sensation scores were measured in 9 female and 8 male volunteers in response to 17 physical contact temperature stimuli, ranging between 18–42 °C. These were applied to their dorsal forearm and lateral torso, across two sessions. Results: Thermal sensation to physical temperature relationships followed a positive linear and sigmoidal fit at both forearm (r2 = 0.91/r2 = 0.91, respectively) and lateral torso (r2 = 0.90/ r2 = 0.91, respectively). Thermal discomfort to physical temperature relationships followed second and third-order fits at both forearm (r2 = 0.33/r2 = 0.34, respectively) and lateral torso (r2 = 0.38/r2 = 0.39, respectively) test sites. There were no sex-related or regional site differences in thermal sensation and discomfort across a wide range of physical contact temperatures. The median confidence of an individual’s thermal sensation rating was measured at 86%. Conclusion: The relation between thermal sensation and physical contact temperature was well described by both linear and sigmoidal models, i.e., the distance between the thermal sensation anchors is close to equal in terms of physical temperatures changes for the range studied. Participants rated similar thermal discomfort level in both cold and hot thermal stimuli for a given increase or decrease in physical contact temperature or thermal sensation. The confidence of thermal sensation rating did not depend on physical contact temperature.