Rémi Delille
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Rémi Delille has a total of 27 co-authors. Here are the top co-authors by number of shared publications:
- Adeline Petit
Laboratoire LaMé, Univ. Orleans-Univ. Tours-INSA CVL, Bourges, France
2 shared publications - André Langlet
Laboratoire LaMé, Univ. Orleans-Univ. Tours-INSA CVL, Bourges, France
2 shared publications - Aravind Rajan Ayagara
Department of Aeronautical Engineering, Institute of Aeronautical Engineering, Hyderabad, India
2 shared publications - Yves Parmantier
Univ. Orléans, Pôle Capteurs, Bourges, France
2 shared publications A. Bracq
1 shared publication- Anna Wozniak
LBPS/CSPBAT—Institut Galilée, UMR CNRS 7244, Université Sorbonne Paris Nord, 99 Avenue J.B. Clément, 93430 Villetaneuse, France
1 shared publication
Latest Publications
- 17 December 2024
- Published by Springer Nature in Journal of Vibration Engineering & Technologies
- Vol. 12 (8) , 8947-8961
Influence of Auxetic Structure Parameters on the Dynamic Impact Energy Absorption
- 17 December 2024
- Published by Springer Nature in Journal of Vibration Engineering & Technologies
- Vol. 12 (8) , 8947-8961
Influence of Auxetic Structure Parameters on the Dynamic Impact Energy Absorption
- 2 April 2024
- Published by Springer Nature
- p. 479-495
Influence of Auxetic Structure Parameters on Dynamic Impact Energy Absorption
- 2 April 2024
- Published by Springer Nature
- p. 479-495
Influence of Auxetic Structure Parameters on Dynamic Impact Energy Absorption
- Open Access
Simple UV-Grafting of PolyAcrylic and PolyMethacrylic Acid on Silicone Breast Implant Surfaces: Chemical and Mechanical Characterizations
Poly(dimethyl siloxane) (PDMS) is one of the most widely used materials in the biomedical field. Despite its numerous advantages, its hydrophobic character promotes bacterial adhesion and biofilm formation. For breast implants, biocompatibility is challenged due to the biofilm formed around the implant that can degenerate to severe capsular contracture over time. Thus, the laboratory has set up strategies to prevent bacterial contamination by grafting covalently hydrophilic bioactive polymers on the surface of implants. In this study, poly(methacrylic acid) (PMAc) and poly(acrylic acid) (PAAc) were chosen as non-toxic and biocompatible bioactive polymers known for reducing bacteria adhesion. These polymers are also good candidates to lend reactivity on the surface for further functionalization. X-ray photoelectron Spectroscopy (XPS) and Fourier-Transform Infrared spectroscopy (FTIR) analysis have highlighted the covalent grafting of these polymers. Apparent water contact angle measurements have shown the change in hydrophilicity on the surface, and a colorimetric assay allowed us to assess the grafting rate of PMAc and PAAc. Tensile strength assays were performed to ensure that the functionalization process does not significantly alter the material’s mechanical properties. Analyses of the surface aspect and roughness by Scanning Electron Microscope (SEM) and optical profilometer allow us to formulate hypotheses to approach the understanding of the behavior of the polymer once grafted.
Open AccessSimple UV-Grafting of PolyAcrylic and PolyMethacrylic Acid on Silicone Breast Implant Surfaces: Chemical and Mechanical Characterizations
Poly(dimethyl siloxane) (PDMS) is one of the most widely used materials in the biomedical field. Despite its numerous advantages, its hydrophobic character promotes bacterial adhesion and biofilm formation. For breast implants, biocompatibility is challenged due to the biofilm formed around the implant that can degenerate to severe capsular contracture over time. Thus, the laboratory has set up strategies to prevent bacterial contamination by grafting covalently hydrophilic bioactive polymers on the surface of implants. In this study, poly(methacrylic acid) (PMAc) and poly(acrylic acid) (PAAc) were chosen as non-toxic and biocompatible bioactive polymers known for reducing bacteria adhesion. These polymers are also good candidates to lend reactivity on the surface for further functionalization. X-ray photoelectron Spectroscopy (XPS) and Fourier-Transform Infrared spectroscopy (FTIR) analysis have highlighted the covalent grafting of these polymers. Apparent water contact angle measurements have shown the change in hydrophilicity on the surface, and a colorimetric assay allowed us to assess the grafting rate of PMAc and PAAc. Tensile strength assays were performed to ensure that the functionalization process does not significantly alter the material’s mechanical properties. Analyses of the surface aspect and roughness by Scanning Electron Microscope (SEM) and optical profilometer allow us to formulate hypotheses to approach the understanding of the behavior of the polymer once grafted.
- 21 August 2023
- Published by Elsevier in Materials Letters
- Vol. 351
Advancements in numerical modelling of synthetic gel for ballistic impact assessment
- 21 August 2023
- Published by Elsevier in Materials Letters
- Vol. 351
Advancements in numerical modelling of synthetic gel for ballistic impact assessment
- 1 September 2016
- Published by Elsevier in Mechanics of Materials
- Vol. 100, 186-197
Coupled influence of strain rate and heterogeneous fibre orientation on the mechanical behaviour of short-glass-fibre reinforced polypropylene
- 1 September 2016
- Published by Elsevier in Mechanics of Materials
- Vol. 100, 186-197
Coupled influence of strain rate and heterogeneous fibre orientation on the mechanical behaviour of short-glass-fibre reinforced polypropylene