Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Mohamed Ismail Ahmed has a total of 62 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Review of Engineering Design of Electric Vehicles

    by Mohamed Ismail Ahmed, Donya Hamed, Engy Farouk, Ganna Deghady, Hassan Hanafy, Mohab Abdelraouf, Mostafa Mostafa, Saif Farahat, Youssef Zaki, Ehab Ahmed Nossier

    The global transition toward sustainable transportation has increased the adoption of electric vehicles (EVs) to reduce greenhouse gas emissions and lessen the environmental impact of traditional internal combustion engine (ICE) vehicles. This project explores the design, performance, and challenges associated with electric cars, particularly focusing on vital components such as battery technology, charging infrastructure, energy efficiency, and suspension systems. Using Autodesk Inventor for 3D modeling and ANSYS for simulation and analysis, the project thoroughly examines the mechanical and thermal performance of the vehicle. The suspension system integrates a double wishbone design, optimized for race car dynamics, to enhance handling, stability, and performance. The research also evaluates recent advancements in lithium-ion battery technology, which have greatly improved energy density and driving range in modern EVs. Additionally, the project looks into the difficulties of building extensive charging networks and explores the economic, environmental, and social impacts of transitioning to electric vehicle infrastructure. Consumer perceptions and the role of government policies and incentives in promoting EV adoption are also discussed. By analyzing the current state of EV technology and identifying obstacles to mass adoption, this project aims to offer valuable insights into the future of sustainable transportation. The findings highlight the need for continued innovation, strategic investments, and public-private partnerships to expedite the shift to an electrified automotive industry.

  • Open Access

    Sensitivity Evaluation of a Dual-Finger Metamaterial Biosensor for Non-Invasive Glycemia Tracking on Multiple Substrates

    by Esraa Mansour, Mohamed I. Ahmed, Ahmed Allam, Ramesh K. Pokharel, Adel B. Abdel-Rahman

    Accurate, non-invasive glucose monitoring remains a major challenge in biomedical sensing. We present a high-sensitivity planar microwave biosensor that progresses from a 2-cell hexagonal array to an 8-cell hexagonal array, and finally to a 16-cell double-honeycomb (DHC-CSRR) architecture to enhance field confinement and resonance strength. Full-wave simulations using Debye-modeled glucose phantoms demonstrate that the optimized 16-cell array on a Rogers RO3210 substrate substantially increases the electric field intensity and transmission response |S21| sensitivity compared with FR-4 and previous multi-CSRR designs. In vitro measurements using pharmacy-grade glucose solutions (5–25%) and saline mixtures with added glucose, delivered through an acrylic channel aligned to the sensing region, confirm the simulated trends. In vivo, vector network analyzer (VNA) tests were conducted on four human subjects (60–150 mg/dL), comparing single- and dual-finger placements. The FR-4 substrate (εr = 4.4) provided higher frequency sensitivity (2.005 MHz/(mg/dL)), whereas the Rogers RO3210 substrate (εr = 10.2) achieved greater amplitude sensitivity (9.35 × 10−2 dB/(mg/dL)); dual-finger contact outperformed single-finger placement for both substrates. Repeated intra-day VNA measurements yielded narrow 95% confidence intervals on |S21|, with an overall uncertainty of approximately ±0.5 dB across the tested glucose levels. Motivated by the larger |S21| response on Rogers, we adopted amplitude resolution as the primary metric and built a compact prototype using the AD8302-EVALZ with a custom 3D-printed enclosure to enhance measurement precision. In a cohort of 31 participants, capillary blood glucose was obtained using a commercial glucometer, after which two fingers were placed on the sensing region; quadratic voltage-to-glucose calibration yielded R2 = 0.980, root–mean–square error (RMSE) = 2.316 mg/dL, overall accuracy = 97.833%, and local sensitivity = 1.099 mg/dL per mV, with anthropometric variables (weight, height, age) showing no meaningful correlation. Clarke Error Grid Analysis placed 100% of paired measurements in Zone A, indicating clinically acceptable agreement with the reference meter. Benchmarking against commercial continuous glucose monitoring systems highlights substrate selection as a dominant lever for amplitude sensitivity and positions the proposed fully non-invasive, consumable-free architecture as a promising route toward portable RF-based glucose monitors, while underscoring the need for larger cohorts, implementation on flexible biocompatible substrates, and future regulatory pathways.


  • Open Access

    Next-Gen wireless unleashed: Coplanar waveguide antennas on glass for 5G and beyond

    by Islam M. Ibrahim, Ahmed Gamal Abdellatif, Mohamed I. Ahmed, M.M. Elsherbini, M.B. Badawi, Shuja Ansari, Mahmoud A. Shawky


  • Electromagnetic radiation shielding of NBR rubber composites loaded with magnetite and manganese dioxide

    by Abdelhameed Sharaf, Ahmed S. El-Bayoumi, Mohamed I. Ahmed, Ashraf Nasr, Magdy A. Ali, Khaled F. El-Nemr

    This study presents the preparation of acrylonitrile butadiene rubber (NBR) composites loaded with different concentrations of electromagnetic radiation shielding materials like magnetite and manganese dioxide. The composites were subjected to electron beam irradiation at 50 kGy and characterized using Fourier-transform infrared spectroscopy (FTIR) and X-ray diffraction (XRD) tools. The hybrid fillers showed a strong interaction with the NBR rubber matrix, improving mechanical properties like tear strength. Electrically conducting of these filler materials that loaded NBR rubber matrix find a lot of attentions for electromagnetic shielding materials. All prepared samples were measured using vector network analyzer (VNA) with aid of an X-band wave guide to evaluate its performance as an electromagnetic interference (EMI) shielding material. The results showed that all samples improved shielding properties and can be used as low-cost, lightweight, and good-performance shielding materials.


  • Open Access

    Quad-port 28/38 GHz Antenna with Isolation Improvement for 5G Wireless Networks

    by Mai. F. Ahmed, Mohamed I. Ahmed, Ahmed A. Ibrahim, Shaymaa M. Gaber

    A 28/38 GHz quad-port cross-shaped antenna printed on a 0.203 mm Roger RO4003 substrate is designed and fabricated for 5G networks. The antenna consists of a rectangular patch radiator with three triangle slots to enhance the antenna's impedance matching. The four elements are arranged in a cross-shaped layout to achieve the desired compactness of 29 mm × 24.2 mm × 0.203 mm. A thin parasitic strip is inserted between the second and fourth elements to enhance the port isolation. The designed antenna is simulated by utilizing the CST simulator. The antenna achieved S11 < -10 dB at 28 / 38 GHz, with isolation ≥ 20 dB. Furthermore, the E- and H-planes within the anechoic chamber are evaluated to validate the MIMO antenna radiation patterns and gain. The MIMO parameters are calculated, simulated, tested, and its outcomes are under the standard level which confirms the MIMO diversity feature. The ECC of the structure is < 0.001, the DG ≥ 9.95 dB. and the CCL was ≤ 0.2 bit/s/Hz across the dual working band.


  • Open Access

    Textile Antenna with Dual Bands and SAR Measurements for Wearable Communication

    by Mahmoud A. Abdelghany, Mohamed I. Ahmed, Ahmed A. Ibrahim, Arpan Desai, Mai. F. Ahmed

    A novel dual-wideband textile antenna designed for wearable applications is introduced in this study. Embedding antennas into wearable devices requires a detailed analysis of the specific absorption rate (SAR) to ensure safety. To achieve this, SAR values were meticulously simulated and evaluated within a human voxel model, considering various body regions such as the left/right head and the abdominal region. The proposed antenna is a monopole design utilizing denim textile as the substrate material. The characterization of the denim textile substrate is carried out using two different methods. The first analysis included a DAC (Dielectric Assessment Kit), while a ring resonator technique was employed for the second examination. Operating within the frequency bands of (58.06%) 2.2–4 GHz and (61.43) 5.3–10 GHz, the antenna demonstrated flexibility in its dual-wideband capabilities. Extensive simulations and tests were conducted to assess the performance of the antenna in both flat and bent configurations. The SAR results obtained from these tests indicate that the antenna complies with safety standard limits when integrated with the human voxel model. This validation underscores the potential of the proposed antenna for seamless integration into wearable applications, offering a promising solution for future developments in this domain.


  • Open Access

    Compact Four-Port Circularly Polarized MIMO X-Band DRA

    by Ahmed A. Ibrahim, Hijab Zahra, Syed Muzahir Abbas, Mohamed I. Ahmed, Gaurav Varshney, Subhas Mukhopadhyay, Abdelhady Mahmoud

    A circularly polarized (CP) multi-input multioutput (MIMO) dielectric resonator (DR) antenna (DRA) with compact size and four ports is implemented. CP radiation was achieved using the deformed DR geometry excited with aperture coupled feeding. A CPDRA with a single and two ports is investigated. The defected ground structure (DGS) was incorporated into the antenna for improving the isolation between the ports. The DGS was incorporated in such a way that the required phase difference between the generated orthogonal degenerate modes is preserved. This concept could be utilized in implementing a compact four-port CP antenna. The MIMO antenna provides a 10 dB impedance bandwidth of 38% (8.5–12.5 GHz) and a 3 dB AR bandwidth of 9.32% (9.2–10.1 GHz). The gain of the implemented antenna was around 6 dBi in the band where CP radiation was achieved. The MIMO performance parameters were calculated, and their values remained within the acceptable limits. The implemented antenna could suitably be used in X-band applications.


  • Switched Beam Antenna System for V2V Communication in 5G Applications

    by Allam M. Ameen, Mohamed I. Ahmed, Hala Elsadek, Wagdy R. Anis

    In this paper, a switched beam antenna system consists of four Vivaldi antennas for vehicle-to-vehicle communication is presented. The proposed design is realized on a substrate material of “Rogers 5880” with εr=2.2,tanδ=0.002,andεr=2.2,tan⁢δ=0.002,and0.508-mm substrate thickness. The antenna is designed to operate at a center frequency of 28 GHz with operating bandwidth of 1.463 GHz. An overall realized gain of 9.78 dBi is achieved at the intended center frequency. The proposed antenna is designed and simulated using CSTMWS. It is also fabricated using photolithography techniques and measured using R&S vector network analyzer. Good agreement is obtained between both CSTMWS and measured results.


  • Open Access

    Rapid Detection of Coronavirus (COVID-19) Using Microwave Immunosensor Cavity Resonator

    by Dalia M. Elsheakh, Mohamed I. Ahmed, Gomaa M. Elashry, Saad M. Moghannem, Hala A. Elsadek, Waleed N. Elmazny, Nelly H. Alieldin, Esmat A. Abdallah

    This paper presents a rapid diagnostic device for the detection of the pandemic coronavirus (COVID-19) using a micro-immunosensor cavity resonator. Coronavirus has been declared an international public health crisis, so it is important to design quick diagnostic methods for the detection of infected cases, especially in rural areas, to limit the spread of the virus. Herein, a proof-of-concept is presented for a portable laboratory device for the detection of the SARS-CoV-2 virus using electromagnetic biosensors. This device is a microwave cavity resonator (MCR) composed of a sensor operating at industrial, scientific and medical (ISM) 2.45 GHz inserted in 3D housing. The changes of electrical properties of measured serum samples after passing the sensor surface are presented. The three change parameters of the sensor are resonating frequency value, amplitude and phase of the reflection coefficient |S11|. This immune-sensor offers a portable, rapid and accurate diagnostic method for the SARS-CoV-2 virus, which can enable on-site diagnosis of infection. Medical validation for the device is performed through biostatistical analysis using the ROC (Receiver Operating Characteristic) method. The predictive accuracy of the device is 63.3% and 60.6% for reflection and phase, respectively. The device has advantages of low cost, low size and weight and rapid response. It does need a trained technician to operate it since a software program operates automatically. The device can be used at ports’ quarantine units, hospitals, etc.


  • An array of staircase‐shaped circularly polarized DRA

    by Abdelhady Mahmoud, Mohamed I. Ahmed, Gaurav Varshney, Ahmed A. Ibrahim