Gulgun Kavukcu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Gulgun Kavukcu has a total of 35 co-authors. Here are the top co-authors by number of shared publications:
- Yeşim ERTAN
Department of Pathology, Ege University, Izmir, Turkey
4 shared publications - Ilhan Hekimsoy
Department of Radiology, Ege University Faculty of Medicine, Izmir, Turkey
3 shared publications - Süha Süreyya Özbek
Department of Radiology, Ege University Faculty of Medicine, Izmir, Turkey
3 shared publications - Lale Tuna
Kırklareli Eğitim ve Araştırma Hastanesi
2 shared publications - Mehmet Nurullah Orman
Department of Biostatistics and Medical Informatics, Ege University Faculty of Medicine, Izmir, Turkey
2 shared publications - Ozer Makay
Center of Endocrine Surgery, Ozel Saglik Hospital, Izmir, Turkey
2 shared publications
Latest Publications
- 11 August 2025
- Published by Wiley in Journal of Ultrasound in Medicine
- Vol. 45 (1) , 73-83
The Role of Endometrial and Myometrial Elastography in Predicting Pregnancy Outcomes in Frozen and Fresh ICSI Cycles
Objectives: To evaluate the potential role of myometrial and endometrial ultrasonographic elastography prior to embryo transfer in predicting pregnancy and live birth outcomes in frozen and fresh intracytoplasmic sperm injection cycles. Methods: This prospective single‐center study was conducted at a tertiary university hospital between January and June 2024. A total of 111 eligible patients scheduled for embryo transfer in frozen and fresh intracytoplasmic sperm injection cycles underwent myometrial and endometrial elastography 1 h before transfer. Measurements were performed in the sagittal plane using Acoustic Radiation Force Impulse point shear wave elastography by a single operator. The anterior and posterior myometrium and endometrium were evaluated, with three measurements obtained per region and the mean value calculated. Results: The anterior myometrial/endometrial elastography ratio was significantly lower in patients who achieved live birth in the overall population ( P = .036); in fresh embryo transfer cycles ( P = .014); and in fresh cycles where two embryos were transferred ( P = .004). Endometrial elastography values were significantly higher in patients with live births in fresh cycles ( P = .028) and in fresh cycles where two embryos were transferred ( P = .001). In frozen cycles where two embryos were transferred, anterior myometrial elastography values were also significantly lower in patients who achieved live birth ( P = .030). Conclusions: Endometrial and myometrial elastography measurements, particularly the anterior myometrial/endometrial elastography ratio and endometrial elastography values, may be clinically useful in predicting pregnancy outcomes. These findings suggest a potential role for elastographic evaluation in assessing endometrial receptivity prior to embryo transfer.
- 11 August 2025
- Published by Wiley in Journal of Ultrasound in Medicine
- Vol. 45 (1) , 73-83
The Role of Endometrial and Myometrial Elastography in Predicting Pregnancy Outcomes in Frozen and Fresh ICSI Cycles
Objectives: To evaluate the potential role of myometrial and endometrial ultrasonographic elastography prior to embryo transfer in predicting pregnancy and live birth outcomes in frozen and fresh intracytoplasmic sperm injection cycles. Methods: This prospective single‐center study was conducted at a tertiary university hospital between January and June 2024. A total of 111 eligible patients scheduled for embryo transfer in frozen and fresh intracytoplasmic sperm injection cycles underwent myometrial and endometrial elastography 1 h before transfer. Measurements were performed in the sagittal plane using Acoustic Radiation Force Impulse point shear wave elastography by a single operator. The anterior and posterior myometrium and endometrium were evaluated, with three measurements obtained per region and the mean value calculated. Results: The anterior myometrial/endometrial elastography ratio was significantly lower in patients who achieved live birth in the overall population ( P = .036); in fresh embryo transfer cycles ( P = .014); and in fresh cycles where two embryos were transferred ( P = .004). Endometrial elastography values were significantly higher in patients with live births in fresh cycles ( P = .028) and in fresh cycles where two embryos were transferred ( P = .001). In frozen cycles where two embryos were transferred, anterior myometrial elastography values were also significantly lower in patients who achieved live birth ( P = .030). Conclusions: Endometrial and myometrial elastography measurements, particularly the anterior myometrial/endometrial elastography ratio and endometrial elastography values, may be clinically useful in predicting pregnancy outcomes. These findings suggest a potential role for elastographic evaluation in assessing endometrial receptivity prior to embryo transfer.
- 30 December 2024
- Published by Springer Nature in Endocrine
- Vol. 88 (1) , 135-142
Contribution of neck ultrasonography to patient management in patients with differentiated thyroid carcinoma with excellent response to therapy
Purpose To assess the contribution of intense neck ultrasonography (US) follow-up in the clinical management of differentiated thyroid carcinoma (DTC) patients with the American Thyroid Association (ATA) low-intermediate-risk of recurrence and an excellent response after total thyroidectomy and radioiodine therapy. Materials and methods Medical records of patients who underwent serial follow-up neck US examinations between 1996 and 2022 were analyzed retrospectively. The utility of serial US examinations in detecting structural recurrence was assessed in all patients and different subgroups–categorized per the initial risk of recurrence and stimulated thyroglobulin (sTg) level at 1-year response assessment. Results Among 2823 US examinations in 296 patients, 2 (0.1%) were categorized as true-positive, 2670 (94.6%) as true-negative, and 151 (5.3%) as false-positive, whereas no false-negative results were observed. Thus, sensitivity, specificity, positive predictive value (PPV), negative predictive value, and accuracy [confidence interval] in all patients were 100% [34.2–100%], 94.7% [93.8–95.4%], 1.3% [0.36–4.6%], 100% [99.9–100%], and 94.7% [93.8–95.4%], respectively. Non-significant higher PPVs were calculated in intermediate-risk patients and patients having sTg ≥0.1 ng/mL, while slightly lower specificity and accuracy were demonstrated in the former group. No recurrence was identified in patients with a low risk of recurrence and those having sTg <0.1 ng/mL. Conclusion Frequent US examination yields remarkably low PPVs in identifying recurrences in ATA low-intermediate-risk patients with DTC and attaining excellent response after total thyroidectomy and radioiodine ablation. Therefore, US surveillance protocol should be individualized per the initial risk of recurrence and Tg levels at response assessment.
- 30 December 2024
- Published by Springer Nature in Endocrine
- Vol. 88 (1) , 135-142
Contribution of neck ultrasonography to patient management in patients with differentiated thyroid carcinoma with excellent response to therapy
Purpose To assess the contribution of intense neck ultrasonography (US) follow-up in the clinical management of differentiated thyroid carcinoma (DTC) patients with the American Thyroid Association (ATA) low-intermediate-risk of recurrence and an excellent response after total thyroidectomy and radioiodine therapy. Materials and methods Medical records of patients who underwent serial follow-up neck US examinations between 1996 and 2022 were analyzed retrospectively. The utility of serial US examinations in detecting structural recurrence was assessed in all patients and different subgroups–categorized per the initial risk of recurrence and stimulated thyroglobulin (sTg) level at 1-year response assessment. Results Among 2823 US examinations in 296 patients, 2 (0.1%) were categorized as true-positive, 2670 (94.6%) as true-negative, and 151 (5.3%) as false-positive, whereas no false-negative results were observed. Thus, sensitivity, specificity, positive predictive value (PPV), negative predictive value, and accuracy [confidence interval] in all patients were 100% [34.2–100%], 94.7% [93.8–95.4%], 1.3% [0.36–4.6%], 100% [99.9–100%], and 94.7% [93.8–95.4%], respectively. Non-significant higher PPVs were calculated in intermediate-risk patients and patients having sTg ≥0.1 ng/mL, while slightly lower specificity and accuracy were demonstrated in the former group. No recurrence was identified in patients with a low risk of recurrence and those having sTg <0.1 ng/mL. Conclusion Frequent US examination yields remarkably low PPVs in identifying recurrences in ATA low-intermediate-risk patients with DTC and attaining excellent response after total thyroidectomy and radioiodine ablation. Therefore, US surveillance protocol should be individualized per the initial risk of recurrence and Tg levels at response assessment.
- Open Access
- 5 December 2022
- Published by Ege Journal of Medicine in Ege Tıp Dergisi
- Vol. 62 (2) , 279-288
Tiroid nodüllerinin benign ve malign ayırıcı tanısında gerçek zamanlı elastografinin etkinliğinin araştırılması
Aim: The aim of this study was to evaluate the efficiency of real-time elastography (RTE) in the differential diagnosis of thyroid nodules. Materials and Methods: Fifty-two patients with 60 thyroid nodules were included in this study. Real-time elastography examinations were performed on the axial and longitudinal planes. Elastography images were classified between score 1 (whole nodule is soft) and score 5 (hardness in whole nodule and surrounding tissues). Nodules with scores of 1, 2 and 3 were considered benign, and nodules with scores of 4 and 5 were considered malignant. Nodule-to-sternocleidomastoid and thyroid tissue-to-nodule strain ratios (SR) were calculated. The nodules were evaluated by means of size, echogenicity, border, presence of halo and microcalcifications. Elasticity scores and mean strain ratios of all nodules were compared with the cytological or histopathological diagnosis. Results: Forty-three of all cases were benign, and seventeen were malignant. Hypoechogenicity, microcalcifications and absence of halo were statistically related but irregular margins, and a high elasticity score were not statistically related to malignancy. The diagnostic performance of strain ratio was found insignificant. Nodule echogenicity had the highest accuracy among all nodule characteristics. Conclusion: Diagnostic performance of real-time elastography in the differentiation of benign and malignant thyroid nodules is suboptimal. Real-time elastography is not an alternative to gray scale ultrasound.
- 5 December 2022
- Published by Ege Journal of Medicine in Ege Tıp Dergisi
- Vol. 62 (2) , 279-288
Open AccessTiroid nodüllerinin benign ve malign ayırıcı tanısında gerçek zamanlı elastografinin etkinliğinin araştırılması
Aim: The aim of this study was to evaluate the efficiency of real-time elastography (RTE) in the differential diagnosis of thyroid nodules. Materials and Methods: Fifty-two patients with 60 thyroid nodules were included in this study. Real-time elastography examinations were performed on the axial and longitudinal planes. Elastography images were classified between score 1 (whole nodule is soft) and score 5 (hardness in whole nodule and surrounding tissues). Nodules with scores of 1, 2 and 3 were considered benign, and nodules with scores of 4 and 5 were considered malignant. Nodule-to-sternocleidomastoid and thyroid tissue-to-nodule strain ratios (SR) were calculated. The nodules were evaluated by means of size, echogenicity, border, presence of halo and microcalcifications. Elasticity scores and mean strain ratios of all nodules were compared with the cytological or histopathological diagnosis. Results: Forty-three of all cases were benign, and seventeen were malignant. Hypoechogenicity, microcalcifications and absence of halo were statistically related but irregular margins, and a high elasticity score were not statistically related to malignancy. The diagnostic performance of strain ratio was found insignificant. Nodule echogenicity had the highest accuracy among all nodule characteristics. Conclusion: Diagnostic performance of real-time elastography in the differentiation of benign and malignant thyroid nodules is suboptimal. Real-time elastography is not an alternative to gray scale ultrasound.
- 12 September 2022
- Published by Ege Journal of Medicine in Ege Tıp Dergisi
- Vol. 61 (3) , 350-359
ARFI elastography for differentiating malignant and benign thyroid nodules
Aim: To examine the diagnostic performance of virtual touch tissue quantification (VTQ) mode of Acoustic Radiation Force Impulse (ARFI) elastography imaging in differentiating benign and malignant thyroid nodules. Materials and Methods: Two hundred four solid and mostly solid nodules >5mm were prospectively evaluated with ultrasonography, VTQ mode of ARFI elastography, fine needle aspiration biopsy, and when indicated with tissue pathology. Three shear-wave velocities (SWV) measurements were done in 196 nodules. The SWV ratio for each nodule was calculated as the mean value of the SWV of the nodule divided by the mean value of the adjacent parenchyma. The diagnostic performance of SWV value and SWV-ratio were assessed by a receiver-operating characteristic (ROC) curve analysis. Results: The mean SWV value in the normal parenchyma, in benign and malign thyroid nodules, were 2.13±0.44 m/s, 2.06±0.80 m/s, and 2.06±0.88 m/s respectively. The SWV-ratios were 0.97±0.37 for benign thyroid nodules and 1.02±0.40 for malignant thyroid nodules. There was no significant difference between benign and malign nodules in terms of mean SWV values (t=0.008) (P=0.994) or SWV-ratios (t =0.596; P=0.527). No cut-off point was found to predict malignancy. In subgroup analysis, AUCs for the SWV and SWV-ratio were significantly different between nodules ˂10 mm and those ≥10 mm, but not with any other two groups (all P>0.05) (Table-2). The cutoff points for the differential diagnosis were 2.59 m/s for SWV and 1.0 for SWV- ratio respectively for nodules <10 mm. Conclusion: VTQ mode of ARFI imaging does not have a good diagnostic performance for detecting malignancy and cannot contribute to reducing unnecessary thyroid biopsies.
- 12 September 2022
- Published by Ege Journal of Medicine in Ege Tıp Dergisi
- Vol. 61 (3) , 350-359
ARFI elastography for differentiating malignant and benign thyroid nodules
Aim: To examine the diagnostic performance of virtual touch tissue quantification (VTQ) mode of Acoustic Radiation Force Impulse (ARFI) elastography imaging in differentiating benign and malignant thyroid nodules. Materials and Methods: Two hundred four solid and mostly solid nodules >5mm were prospectively evaluated with ultrasonography, VTQ mode of ARFI elastography, fine needle aspiration biopsy, and when indicated with tissue pathology. Three shear-wave velocities (SWV) measurements were done in 196 nodules. The SWV ratio for each nodule was calculated as the mean value of the SWV of the nodule divided by the mean value of the adjacent parenchyma. The diagnostic performance of SWV value and SWV-ratio were assessed by a receiver-operating characteristic (ROC) curve analysis. Results: The mean SWV value in the normal parenchyma, in benign and malign thyroid nodules, were 2.13±0.44 m/s, 2.06±0.80 m/s, and 2.06±0.88 m/s respectively. The SWV-ratios were 0.97±0.37 for benign thyroid nodules and 1.02±0.40 for malignant thyroid nodules. There was no significant difference between benign and malign nodules in terms of mean SWV values (t=0.008) (P=0.994) or SWV-ratios (t =0.596; P=0.527). No cut-off point was found to predict malignancy. In subgroup analysis, AUCs for the SWV and SWV-ratio were significantly different between nodules ˂10 mm and those ≥10 mm, but not with any other two groups (all P>0.05) (Table-2). The cutoff points for the differential diagnosis were 2.59 m/s for SWV and 1.0 for SWV- ratio respectively for nodules <10 mm. Conclusion: VTQ mode of ARFI imaging does not have a good diagnostic performance for detecting malignancy and cannot contribute to reducing unnecessary thyroid biopsies.
- 14 July 2021
- Published by Galenos Yayinevi in Diagnostic and Interventional Radiology
- Vol. 27 (4) , 511-518
Diagnostic performance rates of the ACR-TIRADS and EU-TIRADS based on histopathological evidence
In this study, we aimed to assess the effectiveness of malignancy stratification algorithms of the American College of Radiology (ACR) and European Thyroid Association (ETA) in the delineation of thyroid nodules using a database of nodules that were unequivocally diagnosed by means of histopathological examination and meticulously matched with the imaged nodules. A total of 165 patients having 251 thyroid nodules with histopathologically proven definitive diagnoses during a 5-year period were included in this study. All patients had preoperatively undergone ultrasonography (US) examination, and US characteristics of the thyroid nodules were retrospectively analyzed and assigned in compliance with the thyroid imaging reporting and data system categories recommended by the ACR (ACR-TIRADS) and ETA (EU-TIRADS). The diagnostic effectiveness in the delineation of thyroid nodules and unnecessary fine-needle aspiration (FNAB) rates were evaluated. Overall, 189 nodules (75.30%) were diagnosed as benign, while 62 nodules (24.70%) were reported to be malignant based on histopathological assessment. Sensitivity and specificity rates were 71% and 75% for ACR-TIRADS and 73% and 80% for EU-TIRADS. The area under the curve values were 0.78 and 0.80 for ACR-TIRADS and EU-TIRADS, respectively. The unnecessary FNAB rates were 61% for ACR-TIRADS and 64% for EU-TIRADS as per the recommended criteria of each algorithm. The diagnostic performance of both malignancy stratification systems was signified to be moderate and sufficient in a cohort of nodules with definite histopathological diagnosis. In light of our results, we demonstrated the strengths and weaknesses of the ACR- and EU-TIRADS for physicians who should be familiar with them for optimal management of thyroid nodules.
- 14 July 2021
- Published by Galenos Yayinevi in Diagnostic and Interventional Radiology
- Vol. 27 (4) , 511-518
Diagnostic performance rates of the ACR-TIRADS and EU-TIRADS based on histopathological evidence
In this study, we aimed to assess the effectiveness of malignancy stratification algorithms of the American College of Radiology (ACR) and European Thyroid Association (ETA) in the delineation of thyroid nodules using a database of nodules that were unequivocally diagnosed by means of histopathological examination and meticulously matched with the imaged nodules. A total of 165 patients having 251 thyroid nodules with histopathologically proven definitive diagnoses during a 5-year period were included in this study. All patients had preoperatively undergone ultrasonography (US) examination, and US characteristics of the thyroid nodules were retrospectively analyzed and assigned in compliance with the thyroid imaging reporting and data system categories recommended by the ACR (ACR-TIRADS) and ETA (EU-TIRADS). The diagnostic effectiveness in the delineation of thyroid nodules and unnecessary fine-needle aspiration (FNAB) rates were evaluated. Overall, 189 nodules (75.30%) were diagnosed as benign, while 62 nodules (24.70%) were reported to be malignant based on histopathological assessment. Sensitivity and specificity rates were 71% and 75% for ACR-TIRADS and 73% and 80% for EU-TIRADS. The area under the curve values were 0.78 and 0.80 for ACR-TIRADS and EU-TIRADS, respectively. The unnecessary FNAB rates were 61% for ACR-TIRADS and 64% for EU-TIRADS as per the recommended criteria of each algorithm. The diagnostic performance of both malignancy stratification systems was signified to be moderate and sufficient in a cohort of nodules with definite histopathological diagnosis. In light of our results, we demonstrated the strengths and weaknesses of the ACR- and EU-TIRADS for physicians who should be familiar with them for optimal management of thyroid nodules.
- Open Access
- 1 April 2021
- Published by Korean Society of Ultrasound in Medicine in Ultrasonography
- Vol. 40 (2) , 281-288
Hepatic and splenic sonographic and sonoelastographic findings in pulmonary arterial hypertension
The aim of this study was to evaluate the associations of sonographic and sonoelastographic parameters with clinical cardiac parameters, as well as to assess their value in predicting survival in patients with pulmonary arterial hypertension (PAH). Thirty-six patients with PAH and normal liver function were prospectively enrolled in this prospective study along with 26 healthy controls, all of whom underwent ultrasound and point shear wave elastography examinations. Additionally, the portal vein pulsatility index (PVPI), inferior vena cava collapsibility index, and clinical cardiac variables were obtained in PAH patients. The values of hepatic (LVs) and splenic shear wave velocity (SVs) were compared between PAH patients and controls. The relationships between all sonographic and clinical parameters in the PAH patients were analyzed. Furthermore, their prognostic value in predicting survival was investigated. LVs values in PAH patients (median, 1.62 m/s) were significantly higher than in controls (median, 0.99 m/s), while no significant difference was observed in SVs values. Patients with higher grades of tricuspid regurgitation (TR) had significantly different values of PVPI (P=0.010) and sonoelastographic parameters (P<0.001 for LVs and P=0.004 for SVs) compared to those with less severe TR. Tricuspid annular plane systolic excursion values were the only investigated parameter found to be associated with survival (hazard ratio, 0.814; 95% confidence interval, 0.694 to 0.954; P=0.011). Our results demonstrated a direct association between cardiac congestion (i.e., the severity of TR) and liver stiffness, which should be kept in mind during the assessment of fibrosis in patients with PAH.
- 1 April 2021
- Published by Korean Society of Ultrasound in Medicine in Ultrasonography
- Vol. 40 (2) , 281-288
Open AccessHepatic and splenic sonographic and sonoelastographic findings in pulmonary arterial hypertension
The aim of this study was to evaluate the associations of sonographic and sonoelastographic parameters with clinical cardiac parameters, as well as to assess their value in predicting survival in patients with pulmonary arterial hypertension (PAH). Thirty-six patients with PAH and normal liver function were prospectively enrolled in this prospective study along with 26 healthy controls, all of whom underwent ultrasound and point shear wave elastography examinations. Additionally, the portal vein pulsatility index (PVPI), inferior vena cava collapsibility index, and clinical cardiac variables were obtained in PAH patients. The values of hepatic (LVs) and splenic shear wave velocity (SVs) were compared between PAH patients and controls. The relationships between all sonographic and clinical parameters in the PAH patients were analyzed. Furthermore, their prognostic value in predicting survival was investigated. LVs values in PAH patients (median, 1.62 m/s) were significantly higher than in controls (median, 0.99 m/s), while no significant difference was observed in SVs values. Patients with higher grades of tricuspid regurgitation (TR) had significantly different values of PVPI (P=0.010) and sonoelastographic parameters (P<0.001 for LVs and P=0.004 for SVs) compared to those with less severe TR. Tricuspid annular plane systolic excursion values were the only investigated parameter found to be associated with survival (hazard ratio, 0.814; 95% confidence interval, 0.694 to 0.954; P=0.011). Our results demonstrated a direct association between cardiac congestion (i.e., the severity of TR) and liver stiffness, which should be kept in mind during the assessment of fibrosis in patients with PAH.
- Open Access
- 1 September 2017
- Published by Ege Journal of Medicine in Ege Tıp Dergisi
- Vol. 56 (3) , 115-123
Follicular variant of papillary thyroid carcinoma: Gray-scale and Doppler sonographic features
Aim: The aim of this study was to present the sonographic characteristics of follicular variant of papillary thyroid carcinoma (FVPTC) related to different forms of the thyroid nodules, including those without a capsule. Another purpose was to analyze the color Doppler ultrasonography (CDUS) features of this unique tumor, which have not been intensively studied in previous works.Materials and Methods: Twenty-two thyroid nodules (male/female: 17/5; mean age±SD: 42±16 years; range: 17-70) diagnosed with FVPTC were included in this study. The sonographic and Doppler features of the nodules were analyzed retrospectively. The intranodular pattern of vascularity was categorized with regard to the presence of perinodular and/or intranodular vascular signals, as well as a “spoke-and-wheel” appearance.Results: The length of the nodules varied from 6 to 55 mm. Most of nodules were purely solid (77.3%), isoechoic (59.1%) or hypoechoic (31.8%) and had an oval shape (72.7%), well-defined margins (68.2%) and a peripheral hypoechoic halo (68.2%). Thirty-one percent of the nodules had a lobulated shape with microlobulated margins or an irregular configuration with ill-defined margins. Encapsulated FVPTCs had a peripheral hypoechoic halo and well-defined margins, whereas infiltrative cases exhibited the opposite characteristics. No calcification was observed in 72.7% of the nodules. Perinodular and predominantly peripheral intranodular hypervascularity was observed in 14 nodules (66.7%) and was the dominant pattern of vascularity in most of the encapsulated FVPTCs, unlike the infiltrative FVPTCs.Conclusion: Diagnosis of FVPTC should always be considered when large thyroid nodules with predominantly solid echo-texture and other sonographic features that suggest benignity and nodular hypervascularity are observe.
- 1 September 2017
- Published by Ege Journal of Medicine in Ege Tıp Dergisi
- Vol. 56 (3) , 115-123
Open AccessFollicular variant of papillary thyroid carcinoma: Gray-scale and Doppler sonographic features
Aim: The aim of this study was to present the sonographic characteristics of follicular variant of papillary thyroid carcinoma (FVPTC) related to different forms of the thyroid nodules, including those without a capsule. Another purpose was to analyze the color Doppler ultrasonography (CDUS) features of this unique tumor, which have not been intensively studied in previous works.Materials and Methods: Twenty-two thyroid nodules (male/female: 17/5; mean age±SD: 42±16 years; range: 17-70) diagnosed with FVPTC were included in this study. The sonographic and Doppler features of the nodules were analyzed retrospectively. The intranodular pattern of vascularity was categorized with regard to the presence of perinodular and/or intranodular vascular signals, as well as a “spoke-and-wheel” appearance.Results: The length of the nodules varied from 6 to 55 mm. Most of nodules were purely solid (77.3%), isoechoic (59.1%) or hypoechoic (31.8%) and had an oval shape (72.7%), well-defined margins (68.2%) and a peripheral hypoechoic halo (68.2%). Thirty-one percent of the nodules had a lobulated shape with microlobulated margins or an irregular configuration with ill-defined margins. Encapsulated FVPTCs had a peripheral hypoechoic halo and well-defined margins, whereas infiltrative cases exhibited the opposite characteristics. No calcification was observed in 72.7% of the nodules. Perinodular and predominantly peripheral intranodular hypervascularity was observed in 14 nodules (66.7%) and was the dominant pattern of vascularity in most of the encapsulated FVPTCs, unlike the infiltrative FVPTCs.Conclusion: Diagnosis of FVPTC should always be considered when large thyroid nodules with predominantly solid echo-texture and other sonographic features that suggest benignity and nodular hypervascularity are observe.