Dang-Bao-An Tran
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Dang-Bao-An Tran has a total of 17 co-authors. Here are the top co-authors by number of shared publications:
- Grant A. D. Ritchie
Department of Chemistry University of Oxford Oxford UK
3 shared publications Katherine M. Manfred
University of Oxford
2 shared publicationsRobert Peverall
University of Oxford
2 shared publications- A. Goncharov
Laboratoire de Physique des Lasers, CNRS, Université Sorbonne Paris Nord 1 , Villetaneuse, France
1 shared publication - Anne Amy-Klein
Université Sorbonne Paris Nord
1 shared publication - Benoît Darquié
Laboratoire de Physique des Lasers CNRS Université Sorbonne Paris Nord Villetaneuse 93430 France
1 shared publication
Latest Publications
- Open Access
- 1 March 2024
- Published by AIP Publishing in APL Photonics
- Vol. 9 (3)
Near- to mid-IR spectral purity transfer with a tunable frequency comb: Methanol frequency metrology over a 1.4 GHz span
We report the upgrade and operation of a frequency-comb-assisted high-resolution mid-infrared molecular spectrometer, allowing us to combine high spectral purity, International System of Units (SI)-traceability, wide tunability, and high sensitivity. An optical frequency comb is used to transfer the spectral purity of a SI-traceable 1.54 μm metrology-grade frequency reference to a 10.3 μm quantum cascade laser (QCL). The near-infrared reference is operated at the French time/frequency metrology institute, calibrated there to primary frequency standards, and transferred to Laboratoire de Physique des Lasers via the REFIMEVE fiber network. The QCL exhibits a linewidth of δν ∼ 0.1 Hz and a sub-10−15 relative frequency stability from 0.1 to 10 s, and its frequency is traceable to the SI with a total relative uncertainty better than 4 × 10−14 after 1 s averaging time. We have developed the instrumentation allowing comb modes to be continuously tuned over 9 GHz, resulting in a QCL of record spectral purity uninterruptedly tunable at the precision of the reference over an unprecedented span of Δν = 1.4 GHz. We have used our apparatus to conduct sub-Doppler spectroscopy of methanol in a multi-pass cell, demonstrating state-of-the-art frequency uncertainties down to the few kilohertz level (∼10−10 in relative value). We have observed weak intensity resonances unreported so far, resolved subtle doublets never seen before, and brought to light discrepancies with HITRAN. This demonstrates the potential of our apparatus for probing subtle internal molecular processes, building accurate spectroscopic models of polyatomic molecules of atmospheric or astrophysical interest, and carrying out precise spectroscopic tests of fundamental physics.
- 1 March 2024
- Published by AIP Publishing in APL Photonics
- Vol. 9 (3)
Open AccessNear- to mid-IR spectral purity transfer with a tunable frequency comb: Methanol frequency metrology over a 1.4 GHz span
We report the upgrade and operation of a frequency-comb-assisted high-resolution mid-infrared molecular spectrometer, allowing us to combine high spectral purity, International System of Units (SI)-traceability, wide tunability, and high sensitivity. An optical frequency comb is used to transfer the spectral purity of a SI-traceable 1.54 μm metrology-grade frequency reference to a 10.3 μm quantum cascade laser (QCL). The near-infrared reference is operated at the French time/frequency metrology institute, calibrated there to primary frequency standards, and transferred to Laboratoire de Physique des Lasers via the REFIMEVE fiber network. The QCL exhibits a linewidth of δν ∼ 0.1 Hz and a sub-10−15 relative frequency stability from 0.1 to 10 s, and its frequency is traceable to the SI with a total relative uncertainty better than 4 × 10−14 after 1 s averaging time. We have developed the instrumentation allowing comb modes to be continuously tuned over 9 GHz, resulting in a QCL of record spectral purity uninterruptedly tunable at the precision of the reference over an unprecedented span of Δν = 1.4 GHz. We have used our apparatus to conduct sub-Doppler spectroscopy of methanol in a multi-pass cell, demonstrating state-of-the-art frequency uncertainties down to the few kilohertz level (∼10−10 in relative value). We have observed weak intensity resonances unreported so far, resolved subtle doublets never seen before, and brought to light discrepancies with HITRAN. This demonstrates the potential of our apparatus for probing subtle internal molecular processes, building accurate spectroscopic models of polyatomic molecules of atmospheric or astrophysical interest, and carrying out precise spectroscopic tests of fundamental physics.
- Open Access
- 1 February 2024
- Published by AIP Publishing in The Journal of Chemical Physics
- Vol. 160 (5)
Continuous-wave cavity ringdown for high-sensitivity polarimetry and magnetometry measurements
We report the development of a novel variant of cavity ringdown polarimetry using a continuous-wave laser operating at 532 nm for highly precise chiroptical activity and magnetometry measurements. The key methodology of the apparatus relies upon the external modulation of the laser frequency at the frequency splitting between non-degenerate left- and right-circularly polarized cavity modes. The method is demonstrated by the evaluation of the Verdet constants of crystalline CeF3 and fused silica, in addition to the observation of gas- and solution-phase optical rotations of selected chiral molecules. Specifically, optical rotations of (i) vapors of α-pinene and R-(+)-limonene, (ii) mutarotating D-glucose in water, and (iii) acidified L-histidine solutions are determined. The detection sensitivities for the gas- and solution-phase chiral activity measurements are ∼30 and ∼120μdeg over a 30 s detection period per cavity round trip pass, respectively. Furthermore, the measured optical rotations for R-(+)-limonene are compared with computations performed using the TURBOMOLE quantum chemistry package. The experimentally observed optically rotatory dispersion of this cyclic monoterpene was thus rationalized via a consideration of its room temperature conformer distribution as determined by the aforementioned single-point energy calculations.
- 1 February 2024
- Published by AIP Publishing in The Journal of Chemical Physics
- Vol. 160 (5)
Open AccessContinuous-wave cavity ringdown for high-sensitivity polarimetry and magnetometry measurements
We report the development of a novel variant of cavity ringdown polarimetry using a continuous-wave laser operating at 532 nm for highly precise chiroptical activity and magnetometry measurements. The key methodology of the apparatus relies upon the external modulation of the laser frequency at the frequency splitting between non-degenerate left- and right-circularly polarized cavity modes. The method is demonstrated by the evaluation of the Verdet constants of crystalline CeF3 and fused silica, in addition to the observation of gas- and solution-phase optical rotations of selected chiral molecules. Specifically, optical rotations of (i) vapors of α-pinene and R-(+)-limonene, (ii) mutarotating D-glucose in water, and (iii) acidified L-histidine solutions are determined. The detection sensitivities for the gas- and solution-phase chiral activity measurements are ∼30 and ∼120μdeg over a 30 s detection period per cavity round trip pass, respectively. Furthermore, the measured optical rotations for R-(+)-limonene are compared with computations performed using the TURBOMOLE quantum chemistry package. The experimentally observed optically rotatory dispersion of this cyclic monoterpene was thus rationalized via a consideration of its room temperature conformer distribution as determined by the aforementioned single-point energy calculations.
- Open Access
- 1 September 2021
- Published by Optica Publishing Group in Optics Express
- Vol. 29 (19) , 30114-30122
High performance continuous-wave laser cavity enhanced polarimetry using RF-induced linewidth broadening
We present precise optical rotation measurements of gaseous chiral samples using near-IR continuous-wave cavity-enhanced polarimetry. Optical rotation is determined by comparing cavity ring-down signals for two counter-propagating beams of orthogonal polarisation which are subject to polarisation rotation by the presence of both an optically active sample and a magneto-optic crystal. A broadband RF noise source applied to the laser drive current is used to tune the laser linewidth and optimise the polarimeter, and this noise-induced laser linewidth is quantified using self-heterodyne beat-note detection. We demonstrate the optical rotation measurement of gas phase samples of enantiomers of α-pinene and limonene with an optimum detection precision of 10 µdeg per cavity pass and an uncertainty in the specific rotation of ∼0.1 deg dm−1 (g/ml)−1 and determine the specific rotation parameters at 730 nm, for (+)- and (−)-α-pinene to be 32.10 ± 0.13 and −32.21 ± 0.11 deg dm−1 (g/ml)−1, respectively. Measurements of both a pure R-(+)-limonene sample and a non-racemic mixture of limonene of unknown enantiomeric excess are also presented, illustrating the utility of the technique.
- 1 September 2021
- Published by Optica Publishing Group in Optics Express
- Vol. 29 (19) , 30114-30122
Open AccessHigh performance continuous-wave laser cavity enhanced polarimetry using RF-induced linewidth broadening
We present precise optical rotation measurements of gaseous chiral samples using near-IR continuous-wave cavity-enhanced polarimetry. Optical rotation is determined by comparing cavity ring-down signals for two counter-propagating beams of orthogonal polarisation which are subject to polarisation rotation by the presence of both an optically active sample and a magneto-optic crystal. A broadband RF noise source applied to the laser drive current is used to tune the laser linewidth and optimise the polarimeter, and this noise-induced laser linewidth is quantified using self-heterodyne beat-note detection. We demonstrate the optical rotation measurement of gas phase samples of enantiomers of α-pinene and limonene with an optimum detection precision of 10 µdeg per cavity pass and an uncertainty in the specific rotation of ∼0.1 deg dm−1 (g/ml)−1 and determine the specific rotation parameters at 730 nm, for (+)- and (−)-α-pinene to be 32.10 ± 0.13 and −32.21 ± 0.11 deg dm−1 (g/ml)−1, respectively. Measurements of both a pure R-(+)-limonene sample and a non-racemic mixture of limonene of unknown enantiomeric excess are also presented, illustrating the utility of the technique.
- 26 March 2021
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 93 (13) , 5403-5411
Continuous-Wave Cavity-Enhanced Polarimetry for Optical Rotation Measurement of Chiral Molecules
Precise optical rotation measurements play an important role in the analysis of chiral molecules in various fields, especially in biological chemistry and pharmacology. In this paper, we demonstrate a new variant of continuous-wave cavity-enhanced polarimetry for detecting the optical activity of two enantiomers of a chiral molecule at 730 nm. It is based on a signal-reversing technique for which the chiral specific rotation is directly determined by the cavity ring-down signal from two counter-propagating beams in a bow-tie cavity. In particular, we ensure reproducible excitation of both modes by broadening the linewidth of a diode laser source by application of a radio frequency perturbation to its injection current. The performance of the polarimeter is demonstrated for the specific rotation of (+)- and (−)-α-pinene in different environments, including the pure vapor, open air, and the liquid phase; the detection precision ranges between 10–5 and 10–4 degrees per cavity pass depending on the environment. The apparatus is a robust and practical tool for quantifying chirality and can be developed for the entire visible and near-infrared spectral regions.
- 26 March 2021
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 93 (13) , 5403-5411
Continuous-Wave Cavity-Enhanced Polarimetry for Optical Rotation Measurement of Chiral Molecules
Precise optical rotation measurements play an important role in the analysis of chiral molecules in various fields, especially in biological chemistry and pharmacology. In this paper, we demonstrate a new variant of continuous-wave cavity-enhanced polarimetry for detecting the optical activity of two enantiomers of a chiral molecule at 730 nm. It is based on a signal-reversing technique for which the chiral specific rotation is directly determined by the cavity ring-down signal from two counter-propagating beams in a bow-tie cavity. In particular, we ensure reproducible excitation of both modes by broadening the linewidth of a diode laser source by application of a radio frequency perturbation to its injection current. The performance of the polarimeter is demonstrated for the specific rotation of (+)- and (−)-α-pinene in different environments, including the pure vapor, open air, and the liquid phase; the detection precision ranges between 10–5 and 10–4 degrees per cavity pass depending on the environment. The apparatus is a robust and practical tool for quantifying chirality and can be developed for the entire visible and near-infrared spectral regions.