Yakov V. Rakshun
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Yakov V. Rakshun has a total of 43 co-authors. Here are the top co-authors by number of shared publications:
- Andrei Trebushinin
European XFEL GmbH
2 shared publications - Dmitry Sorokoletov
Siberian Circular Photon Source (SKIF) Shared Research Center, Boreskov Institute of Catalysis, Siberian Branch of the Russian Academy of Sciences, Novosibirsk, Russia
2 shared publications N. I. Chkhalo
Institute for Physics of Microstructures, Russian Academy of Sciences, Nizhny Novgorod, Russia
2 shared publicationsV. A. Chernov
Budker Institute of Nuclear Physics, Siberian Branch, Russian Academy of Sciences, Novosibirsk, Russia
2 shared publications- Yuri V. Khomyakov
Budker Institute of Nuclear Physics, Siberian Branch, Russian Academy of Sciences, Novosibirsk, Russia
2 shared publications A. M. Korsunsky
Department of Engineering Science, University of Oxford, Parks Road, Oxford, UK
1 shared publication
Latest Publications
- 1 December 2023
- Published by Pleiades Publishing Ltd in Journal of Surface Investigation: X-Ray, Synchrotron and Neutron Techniques
- Vol. 17 (S1) , S78-S89
Designing a Universal Undulator Beamline for Materials Science: A Conceptual Approach
We present the conceptual design of a universal materials-research beamline based on the undulator of a fourth-generation synchrotron-radiation source. The distinctive feature of the beamline is its capability to work with both spectrally narrow (ΔE/E ~ 10–4) and relatively broad, high-intensity radiation beams (5 × 10–2). The optical scheme enables rapid switching between diffraction, radiographic, and spectroscopic experimental methods while keeping the beam’s position fixed on the test sample and varying the spot size of the radiation from 100 nm to 1 mm.
- 1 December 2023
- Published by Pleiades Publishing Ltd in Journal of Surface Investigation: X-Ray, Synchrotron and Neutron Techniques
- Vol. 17 (S1) , S78-S89
Designing a Universal Undulator Beamline for Materials Science: A Conceptual Approach
We present the conceptual design of a universal materials-research beamline based on the undulator of a fourth-generation synchrotron-radiation source. The distinctive feature of the beamline is its capability to work with both spectrally narrow (ΔE/E ~ 10–4) and relatively broad, high-intensity radiation beams (5 × 10–2). The optical scheme enables rapid switching between diffraction, radiographic, and spectroscopic experimental methods while keeping the beam’s position fixed on the test sample and varying the spot size of the radiation from 100 nm to 1 mm.
- 16 June 2023
- Published by Pleiades Publishing Ltd in Journal of Surface Investigation: X-Ray, Synchrotron and Neutron Techniques
- Vol. 17 (3) , 531-541
On the Project of Scanning and Projection Microscopes for the Nanoscope Station for Biological Research in the Water Window
A brief description of the concept of a soft X-ray microscope for the Nanoscope station, which is planned to be installed at the SKIF fourth-generation synchrotron, is given. The microscope is designed to study the structure of cells and dynamic processes in them with nanometer spatial resolution. It will use a unique absorption contrast of ~15 between carbon-containing structures and water in the spectral range of the water window, λ = 2.3–4.3 nm, which eliminates the need for contrasting and the use of fluorophores and minimizes the doses of ionizing radiation absorbed in the samples to obtain high-quality 3D images. The scanning and projection schemes of the microscope, their main technical characteristics, including the calculated spectra and parameters of the undulator source are presented, and an estimate of the absorbed doses depending on the resolution is obtained. The main advantage of the proposed concept lies in the use of an objective lens of high-aperture multilayer X-ray mirrors, which makes it possible to clearly visualize the focal section of the sample. Technically simple axial tomography will also be used to reconstruct the three-dimensional structure of frozen or dried samples. In the scanning scheme, due to a low dose of radiation, it will be possible to study living plant cells with a resolution of up to 10 nm, animals with a resolution of up to 80 nm, and cryofixed samples with a resolution of up to 5 nm. In the projection scheme, due to simultaneous observation of the entire focal XY section, the time for obtaining three-dimensional images is significantly reduced, but due to a large dose, it will be oriented mainly on the study of fixed samples.
- 16 June 2023
- Published by Pleiades Publishing Ltd in Journal of Surface Investigation: X-Ray, Synchrotron and Neutron Techniques
- Vol. 17 (3) , 531-541
On the Project of Scanning and Projection Microscopes for the Nanoscope Station for Biological Research in the Water Window
A brief description of the concept of a soft X-ray microscope for the Nanoscope station, which is planned to be installed at the SKIF fourth-generation synchrotron, is given. The microscope is designed to study the structure of cells and dynamic processes in them with nanometer spatial resolution. It will use a unique absorption contrast of ~15 between carbon-containing structures and water in the spectral range of the water window, λ = 2.3–4.3 nm, which eliminates the need for contrasting and the use of fluorophores and minimizes the doses of ionizing radiation absorbed in the samples to obtain high-quality 3D images. The scanning and projection schemes of the microscope, their main technical characteristics, including the calculated spectra and parameters of the undulator source are presented, and an estimate of the absorbed doses depending on the resolution is obtained. The main advantage of the proposed concept lies in the use of an objective lens of high-aperture multilayer X-ray mirrors, which makes it possible to clearly visualize the focal section of the sample. Technically simple axial tomography will also be used to reconstruct the three-dimensional structure of frozen or dried samples. In the scanning scheme, due to a low dose of radiation, it will be possible to study living plant cells with a resolution of up to 10 nm, animals with a resolution of up to 80 nm, and cryofixed samples with a resolution of up to 5 nm. In the projection scheme, due to simultaneous observation of the entire focal XY section, the time for obtaining three-dimensional images is significantly reduced, but due to a large dose, it will be oriented mainly on the study of fixed samples.
- Open Access
- 1 January 2023
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 2803 (1) , 040006
New intuitive regularizing approaches for deconvolution problems
We propose two intuitive simple approaches that would help to make the solving scheme of deconvolution problem so as to minimize strongly the systematic component of the error of the right part of convolution equation. Specific changes are included to the block Toeplitz matrix that are defined according to the main purpose which is to minimize the influence of either discretization errors, or those originated by bound effects, or both. Wherein the problem does not lose its linear features, remaining a system of linear equations but with changed matrix (convolution operator). Two different modified solving schemes have been adapted and successfully tested in one-and two-dimensional cases with model signal distributions, respectively. The final gain of precision in the first case was 10 to 30 % by the RMS value of restored solutions’ error whereas in the second case only the approach we propose yielded a satisfactory result.
- 1 January 2023
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 2803 (1) , 040006
Open AccessNew intuitive regularizing approaches for deconvolution problems
We propose two intuitive simple approaches that would help to make the solving scheme of deconvolution problem so as to minimize strongly the systematic component of the error of the right part of convolution equation. Specific changes are included to the block Toeplitz matrix that are defined according to the main purpose which is to minimize the influence of either discretization errors, or those originated by bound effects, or both. Wherein the problem does not lose its linear features, remaining a system of linear equations but with changed matrix (convolution operator). Two different modified solving schemes have been adapted and successfully tested in one-and two-dimensional cases with model signal distributions, respectively. The final gain of precision in the first case was 10 to 30 % by the RMS value of restored solutions’ error whereas in the second case only the approach we propose yielded a satisfactory result.
- 1 January 2023
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 94 (1) , 013305
A concept of “materials” diffraction and imaging beamline for SKIF: Siberian circular photon source
Over the next decade, the extremely brilliant fourth generation synchrotron radiation sources are set to become a key driving force in materials characterization and technology development. In this study, we present a conceptual design of a versatile “Materia” diffraction and imaging beamline for a low-emittance synchrotron radiation facility. The beamline was optimized for operation with three main principal delivery regimes: parallel collimated beam ∼1 mm beam size, micro-focus regime with ∼10 μm beam spot size on the sample, and nano-focus regime with ΔE/E of 5 × 10−2. The manuscript presents the details of the principal characteristics selected for the insertion device and beamline optics, the materials characterization techniques, including the simulations of thermal load impact on the critical beamline optics components. Significant efforts were made to design the monochromators to mitigate the very high beam power load produced by a superconducting undulator source. The manuscript will be of interest to research groups involved in the design of new synchrotron beamlines.
- 1 January 2023
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 94 (1) , 013305
A concept of “materials” diffraction and imaging beamline for SKIF: Siberian circular photon source
Over the next decade, the extremely brilliant fourth generation synchrotron radiation sources are set to become a key driving force in materials characterization and technology development. In this study, we present a conceptual design of a versatile “Materia” diffraction and imaging beamline for a low-emittance synchrotron radiation facility. The beamline was optimized for operation with three main principal delivery regimes: parallel collimated beam ∼1 mm beam size, micro-focus regime with ∼10 μm beam spot size on the sample, and nano-focus regime with ΔE/E of 5 × 10−2. The manuscript presents the details of the principal characteristics selected for the insertion device and beamline optics, the materials characterization techniques, including the simulations of thermal load impact on the critical beamline optics components. Significant efforts were made to design the monochromators to mitigate the very high beam power load produced by a superconducting undulator source. The manuscript will be of interest to research groups involved in the design of new synchrotron beamlines.
- Open Access
- 26 March 2021
- Published by International Union of Crystallography (IUCr) in Journal of Synchrotron Radiation
- Vol. 28 (3) , 769-777
Spatial-frequency features of radiation produced by a step-wise tapered undulator
A scheme to generate wide-bandwidth radiation using a step-wise tapered undulator with a segmented structure is proposed. This magnetic field configuration allows to broaden the undulator harmonic spectrum by two orders of magnitude, providing 1 keV bandwidth with spectral flux density exceeding 1016 photons s−1 mm−2 (0.1% bandwidth)−1 at 5 keV on the sample. Such a magnetic setup is applicable to superconducting devices where magnetic tapering cannot be arranged mechanically. The resulting radiation with broadband spectrum and flat-top shape may be exploited at a multipurpose beamline for scanning over the spectrum at time scales of 10–100 ms. The radiation from a segmented undulator is described analytically and derivations with numerical simulations are verified. In addition, a start-to-end simulation of an optical beamline is performed and issues related to the longitudinally distributed radiation source and its image upon focusing on the sample are addressed.
- 26 March 2021
- Published by International Union of Crystallography (IUCr) in Journal of Synchrotron Radiation
- Vol. 28 (3) , 769-777
Open AccessSpatial-frequency features of radiation produced by a step-wise tapered undulator
A scheme to generate wide-bandwidth radiation using a step-wise tapered undulator with a segmented structure is proposed. This magnetic field configuration allows to broaden the undulator harmonic spectrum by two orders of magnitude, providing 1 keV bandwidth with spectral flux density exceeding 1016 photons s−1 mm−2 (0.1% bandwidth)−1 at 5 keV on the sample. Such a magnetic setup is applicable to superconducting devices where magnetic tapering cannot be arranged mechanically. The resulting radiation with broadband spectrum and flat-top shape may be exploited at a multipurpose beamline for scanning over the spectrum at time scales of 10–100 ms. The radiation from a segmented undulator is described analytically and derivations with numerical simulations are verified. In addition, a start-to-end simulation of an optical beamline is performed and issues related to the longitudinally distributed radiation source and its image upon focusing on the sample are addressed.
- 1 February 2019
- Published by Allerton Press in Bulletin of the Russian Academy of Sciences: Physics
- Vol. 83 (2) , 129-133
Designing a Technological Station for Synchrotron Radiation on the VEPP-4M
A technological station for synchrotron radiation (referred to below as the TSSR) is created on Channel 1 of synchrotron radiation (SR) output on the VEPP-4M storage ring. The new station is...
- 1 February 2019
- Published by Allerton Press in Bulletin of the Russian Academy of Sciences: Physics
- Vol. 83 (2) , 129-133
Designing a Technological Station for Synchrotron Radiation on the VEPP-4M
A technological station for synchrotron radiation (referred to below as the TSSR) is created on Channel 1 of synchrotron radiation (SR) output on the VEPP-4M storage ring. The new station is...
- 31 January 2015
- Published by Allerton Press in Bulletin of the Russian Academy of Sciences: Physics
- Vol. 79 (1) , 122-125
Seasonal geochemical signals in varves of the Lake Donguz-Orun bottom sediments from scanning X-ray fluorescence with the use of microcapillary X-ray optics
The distribution of minor elements in a sample of bottom sediments from Lake Donguz-Orun, Northern Caucasus, is studied via scanning X-ray fluorescence microanalysis using beams of synchrotron radiation from the VEPP-3 storage ring. A beam of exciting radiation 15 μm in diameter is obtained with microcapillary X-ray optics to conduct detailed studies of the inner structure of individual varves. It is shown that the Rb/Sr ratio is related to particle size and could be a spring flood marker. Estimates of the current rate of sedimentation in the lake, based on counting visually discernible layers and from geochemical indicators, coincides with the isotopic data. Quantitative links between sediment composition and meteorological data (temperature and atmospheric precipitation) were found.
- 31 January 2015
- Published by Allerton Press in Bulletin of the Russian Academy of Sciences: Physics
- Vol. 79 (1) , 122-125
Seasonal geochemical signals in varves of the Lake Donguz-Orun bottom sediments from scanning X-ray fluorescence with the use of microcapillary X-ray optics
The distribution of minor elements in a sample of bottom sediments from Lake Donguz-Orun, Northern Caucasus, is studied via scanning X-ray fluorescence microanalysis using beams of synchrotron radiation from the VEPP-3 storage ring. A beam of exciting radiation 15 μm in diameter is obtained with microcapillary X-ray optics to conduct detailed studies of the inner structure of individual varves. It is shown that the Rb/Sr ratio is related to particle size and could be a spring flood marker. Estimates of the current rate of sedimentation in the lake, based on counting visually discernible layers and from geochemical indicators, coincides with the isotopic data. Quantitative links between sediment composition and meteorological data (temperature and atmospheric precipitation) were found.