Tobias Duda
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Tobias Duda has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
- Georg Jacobs
Institute for Machine Elements and Systems Engineering, RWTH Aachen University, Aachen, Germany, Germany
4 shared publications Dennis Bosse
Center for Wind Power Drives - RWTH Aachen University Campus Boulevard 61, 52074 Aachen, Germany
2 shared publications- Dennis Bosse
Center for Wind Power Drives, Aachen, Germany
2 shared publications - Julian Röder
RWTH Aachen University
2 shared publications - Christoph Mulder
Institute of Electrical Machines (IEM), RWTH Aachen University,Aachen,Germany
1 shared publication - Dennis Bosse
Center for Wind Power Drives (CWD), RWTH Aachen University, 52062 Aachen, Germany
1 shared publication
Latest Publications
- Open Access
Investigation of Dynamic Loads in Wind Turbine Drive Trains Due to Grid and Power Converter Faults
Electrical faults can lead to transient and dynamic excitations of the electromagnetic generator torque in wind turbines. The fast changes in the generator torque lead to load oscillations and rapid changes in the speed of rotation. The combination of dynamic load reversals and changing rotational speeds can be detrimental to gearbox components. This paper shows, via simulation, that the smearing risk increases due to the electrical faults for cylindrical roller bearings on the high speed shaft of a wind turbine research nacelle. A grid fault was examined for the research nacelle with a doubly fed induction generator concept. Furthermore, a converter fault was analyzed for the full size converter concept. Both wind turbine grid connection concepts used the same mechanical drive train. Thus, the mechanical component loading was comparable. During the grid fault, the risk of smearing increased momentarily by a maximum of around 1.8 times. During the converter fault, the risk of smearing increased by around 4.9 times. Subsequently, electrical faults increased the risk of damage to the wind turbine gearbox bearings, especially on the high speed stage.
Open AccessInvestigation of Dynamic Loads in Wind Turbine Drive Trains Due to Grid and Power Converter Faults
Electrical faults can lead to transient and dynamic excitations of the electromagnetic generator torque in wind turbines. The fast changes in the generator torque lead to load oscillations and rapid changes in the speed of rotation. The combination of dynamic load reversals and changing rotational speeds can be detrimental to gearbox components. This paper shows, via simulation, that the smearing risk increases due to the electrical faults for cylindrical roller bearings on the high speed shaft of a wind turbine research nacelle. A grid fault was examined for the research nacelle with a doubly fed induction generator concept. Furthermore, a converter fault was analyzed for the full size converter concept. Both wind turbine grid connection concepts used the same mechanical drive train. Thus, the mechanical component loading was comparable. During the grid fault, the risk of smearing increased momentarily by a maximum of around 1.8 times. During the converter fault, the risk of smearing increased by around 4.9 times. Subsequently, electrical faults increased the risk of damage to the wind turbine gearbox bearings, especially on the high speed stage.
- Open Access
- 30 March 2021
- Published by Springer Nature in Forschung im Ingenieurwesen
- Vol. 85 (2) , 257-264
Integration of electromagnetic finite element models in a multibody simulation to evaluate vibrations in direct-drive generators
This paper introduces a novel electromechanical model for calculating electromagnetic excited structural vibrations and structure borne acoustics for gearless wind turbines. Therefore, the wind turbine model structure is explained and a drivetrain model is derived to investigate the drivetrain decoupled from the aerodynamic excitations. The drivetrain model is fed with results from an electromagnetic finite element model of the generator considering air gap width changes and the wind turbine torque and speed characteristics. Furthermore, an exemplary ramp-up of the drivetrain is simulated. It can be seen, that generator structure oscillations are excited during certain rotational speeds, which may be relevant for the acoustic behavior of the turbine.
- 30 March 2021
- Published by Springer Nature in Forschung im Ingenieurwesen
- Vol. 85 (2) , 257-264
Open AccessIntegration of electromagnetic finite element models in a multibody simulation to evaluate vibrations in direct-drive generators
This paper introduces a novel electromechanical model for calculating electromagnetic excited structural vibrations and structure borne acoustics for gearless wind turbines. Therefore, the wind turbine model structure is explained and a drivetrain model is derived to investigate the drivetrain decoupled from the aerodynamic excitations. The drivetrain model is fed with results from an electromagnetic finite element model of the generator considering air gap width changes and the wind turbine torque and speed characteristics. Furthermore, an exemplary ramp-up of the drivetrain is simulated. It can be seen, that generator structure oscillations are excited during certain rotational speeds, which may be relevant for the acoustic behavior of the turbine.
- Open Access
- 26 March 2021
- Published by Springer Nature in Forschung im Ingenieurwesen
- Vol. 85 (2) , 251-256
Simulative investigation of wind turbine gearbox loads during power converter fault
Three phase short circuit power converter faults in wind turbines (WT) result in highly dynamic generator torque reversals, which lead to load reversals within the drivetrain. Dynamic load reversals in combination with changing rotational speeds are, for example, critical for smearing within roller bearings. Therefore, an investigation of the correlation between three phase short circuit converter faults and drivetrain component failures is necessary.Due to the risk of damage and the resulting costs, it is not economically feasible to extensively investigate three phase short circuit converter faults on test benches. Valid WT drivetrain models can be used instead. A WT drivetrain model, which has been developed and validated in a national project at the CWD, is used and a three phase short circuit converter fault is implemented. In this paper, the resulting torque load on the drivetrain for a three phase short circuit converter fault in rated power production is presented. This converter fault leads to a highly dynamic reversing electromagnetic torque which exceeds the rated torque by a factor of three. As a result the load on the rotor side high speed shaft (HSS) bearing oscillates and increases by around 15 per cent compared to rated power production. Simultaneously the rotational velocity of the HSS oscillates with an amplitude of 10 rpm. Therefore an increase in the risk of smearing is expected.
- 26 March 2021
- Published by Springer Nature in Forschung im Ingenieurwesen
- Vol. 85 (2) , 251-256
Open AccessSimulative investigation of wind turbine gearbox loads during power converter fault
Three phase short circuit power converter faults in wind turbines (WT) result in highly dynamic generator torque reversals, which lead to load reversals within the drivetrain. Dynamic load reversals in combination with changing rotational speeds are, for example, critical for smearing within roller bearings. Therefore, an investigation of the correlation between three phase short circuit converter faults and drivetrain component failures is necessary.Due to the risk of damage and the resulting costs, it is not economically feasible to extensively investigate three phase short circuit converter faults on test benches. Valid WT drivetrain models can be used instead. A WT drivetrain model, which has been developed and validated in a national project at the CWD, is used and a three phase short circuit converter fault is implemented. In this paper, the resulting torque load on the drivetrain for a three phase short circuit converter fault in rated power production is presented. This converter fault leads to a highly dynamic reversing electromagnetic torque which exceeds the rated torque by a factor of three. As a result the load on the rotor side high speed shaft (HSS) bearing oscillates and increases by around 15 per cent compared to rated power production. Simultaneously the rotational velocity of the HSS oscillates with an amplitude of 10 rpm. Therefore an increase in the risk of smearing is expected.
- Open Access
- 1 May 2019
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 1222 (1) , 012029
Investigation of Modelling Depths for an Electromechanical Simulation of a Direct-Drive Generator Considering Parasitic Airgap Forces and External Loads
This paper shows a multiphysical simulation approach for direct - drive generators, including electromagnetic force calculations and multibody simulation. The objective of this method is to determine the airgap width distribution of the generator during operation. In this investigation different modelling depths of the electromechanical model are discussed. Especially the modelling of the electromagnetic force application and integration of flexible structural elements is discussed.
- 1 May 2019
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 1222 (1) , 012029
Open AccessInvestigation of Modelling Depths for an Electromechanical Simulation of a Direct-Drive Generator Considering Parasitic Airgap Forces and External Loads
This paper shows a multiphysical simulation approach for direct - drive generators, including electromagnetic force calculations and multibody simulation. The objective of this method is to determine the airgap width distribution of the generator during operation. In this investigation different modelling depths of the electromechanical model are discussed. Especially the modelling of the electromagnetic force application and integration of flexible structural elements is discussed.
- Open Access
- 18 June 2018
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 1037 (5) , 052031
Investigation of dynamic drivetrain behaviour of a wind turbine during a power converter fault
Damage in electrical components during operation of the drive train of wind turbines can lead to highly dynamic load situations. In particular, power converter components are affected by frequent damage, which leads to highly dynamic torque oscillations. As part of a national project, a research nacelle for a wind turbine was set up at the Center for Wind Power Drives (CWD) and examined with the help of a 4 MW test rig. This test rig allows the drive train of a wind turbine to be intensively investigated so that even the highly dynamic load conditions of a power converter fault could be studied. Among other tests, the fault case of a power converter short circuit was synthetically generated. This paper aims to give an insight into the investigation methodology, test setup and looks into the high speed shaft bearing of the gearbox during this load case in detail.
- 18 June 2018
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 1037 (5) , 052031
Open AccessInvestigation of dynamic drivetrain behaviour of a wind turbine during a power converter fault
Damage in electrical components during operation of the drive train of wind turbines can lead to highly dynamic load situations. In particular, power converter components are affected by frequent damage, which leads to highly dynamic torque oscillations. As part of a national project, a research nacelle for a wind turbine was set up at the Center for Wind Power Drives (CWD) and examined with the help of a 4 MW test rig. This test rig allows the drive train of a wind turbine to be intensively investigated so that even the highly dynamic load conditions of a power converter fault could be studied. Among other tests, the fault case of a power converter short circuit was synthetically generated. This paper aims to give an insight into the investigation methodology, test setup and looks into the high speed shaft bearing of the gearbox during this load case in detail.