Marina Valença Alencar
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Marina Valença Alencar has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
- Edilaine Martins Soler
UNESP
2 shared publications - Leonardo Nepomuceno
Faculdade de Engenharia, Universidade Estadual Paulista
2 shared publications André Christóvão Pio Martins
Univ Estadual Paulista UNESP, Fac Engn, Campus Bauru, Sao Paulo, Brazil
1 shared publicationAntonio Roberto Balbo
Univ Estadual Paulista UNESP, Fac Ciencias, Campus Bauru, Sao Paulo, Brazil
1 shared publication- Antonio Roberto Balbo
Universidade Estadual Paulista (UNESP)
1 shared publication - Diego Nunes da Silva
Instituto Federal de Educação, Ciência e Tecnologia de São Paulo
1 shared publication
Latest Publications
- 6 January 2024
- Published by Elsevier in Applied Energy
- Vol. 358
Discrete optimal power flow with prohibited zones, multiple-fuel options, and practical operational rules for control devices
- 6 January 2024
- Published by Elsevier in Applied Energy
- Vol. 358
Discrete optimal power flow with prohibited zones, multiple-fuel options, and practical operational rules for control devices
- 1 October 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Latin America Transactions
- Vol. 18 (10) , 1666-1674
Reducing the Number of Control Actions in the Discrete Reactive Optimal Power Flow
This paper proposes a new formulation for the Discrete Reactive Optimal Power Flow problem (DROPF) that aims at reducing the number of control actions of the problem. For such a purpose, additional constraints are introduced in the classical model to the DROPF problem so as to represent specific behaviors of voltage control devices in the electrical system. These behaviors involve the actuation of a control device only when the voltage magnitude limit of the bus controlled by such device is effectively reached. The proposed DROPF model is solved by the branch-and-bound method implemented in the free solver BONMIN. Numerical tests were performed using the IEEE 14, 30 and 118 bus electrical systems and demonstrated the efficiency of the proposed model. The results are compared with the ones obtained by a classical DROPF.
- 1 October 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Latin America Transactions
- Vol. 18 (10) , 1666-1674
Reducing the Number of Control Actions in the Discrete Reactive Optimal Power Flow
This paper proposes a new formulation for the Discrete Reactive Optimal Power Flow problem (DROPF) that aims at reducing the number of control actions of the problem. For such a purpose, additional constraints are introduced in the classical model to the DROPF problem so as to represent specific behaviors of voltage control devices in the electrical system. These behaviors involve the actuation of a control device only when the voltage magnitude limit of the bus controlled by such device is effectively reached. The proposed DROPF model is solved by the branch-and-bound method implemented in the free solver BONMIN. Numerical tests were performed using the IEEE 14, 30 and 118 bus electrical systems and demonstrated the efficiency of the proposed model. The results are compared with the ones obtained by a classical DROPF.