Cheng-Yen Chen
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Cheng-Yen Chen has a total of 37 co-authors. Here are the top co-authors by number of shared publications:
Niang-Cheng Lin
Division of Transplantation Surgery, Department of Surgery, Taipei Veterans General Hospital, Taipei, Taiwan; School of Medicine, National Yang Ming Chiao Tung University, Taipei, Taiwan
4 shared publicationsChe-Chuan Loong
Division of Transplantation Surgery, Department of Surgery, Taipei Veterans General Hospital, Taipei, Taiwan; School of Medicine, National Yang Ming Chiao Tung University, Taipei, Taiwan
3 shared publications- Chinsu Liu
Division of Transplantation Surgery, Department of Surgery, Taipei Veterans General Hospital, Taipei, Taiwan
3 shared publications Cheng-Yuan Hsia
School of Medicine, National Yang Ming Chiao Tung University, Taipei, Taiwan; Division of General Surgery, Department of Surgery, Taipei Veterans General Hospital, Taipei, Taiwan
2 shared publications- Chih Chung Yang
Institute of Photonics and Optoelectronics, and Department of Electrical Engineering, National Taiwan University, Taipei, Taiwan
2 shared publications - Chih-Ching Lin
School of Medicine, National Yang Ming Chiao Tung University, Taipei, Taiwan ROC; Division of Nephrology, Department of Medicine, Taipei Veterans General Hospital, Taipei, Taiwan ROC; Institute of Clinical Medicine, National Yang Ming Chiao Tung University, Taipei, Taiwan ROC
2 shared publications
Latest Publications
- 23 May 2025
- Published by MyJove Corporation in Journal of Visualized Experiments
- No. 219,p. e67988
Laparoscopic-Assisted Seldinger Technique for Peritoneal Dialysis Catheter Insertion
The management of kidney failure has advanced considerably, with peritoneal dialysis (PD) established as a reliable treatment option that uses the peritoneal membrane to remove excess fluid and toxins. PD has shown particular benefits in the initial stages of treatment, potentially leading to better outcomes compared to hemodialysis. Successful PD, however, depends heavily on the correct placement of the PD catheter. This study presents a protocol to perform the laparoscopic-assisted Seldinger technique (LAST) for peritoneal dialysis catheter insertion, highlighting a combination of the Seldinger method's minimal invasiveness with the enhanced visualization of laparoscopy. LAST allows precise catheter placement, making it especially suitable for patients with prior abdominal surgery or those requiring urgent-start PD. This technique enables patients to initiate PD within a day of catheter insertion. The post-surgical protocol involves a gradual increase in dialysate volume, allowing patients to achieve a full PD dose by day five while maintaining controlled peritoneal pressure and minimizing the risk of dialysate leaks. By integrating laparoscopic visualization with the minimally invasive Seldinger technique, LAST has the potential to offer a superior alternative to traditional methods
- 23 May 2025
- Published by MyJove Corporation in Journal of Visualized Experiments
- No. 219,p. e67988
Laparoscopic-Assisted Seldinger Technique for Peritoneal Dialysis Catheter Insertion
The management of kidney failure has advanced considerably, with peritoneal dialysis (PD) established as a reliable treatment option that uses the peritoneal membrane to remove excess fluid and toxins. PD has shown particular benefits in the initial stages of treatment, potentially leading to better outcomes compared to hemodialysis. Successful PD, however, depends heavily on the correct placement of the PD catheter. This study presents a protocol to perform the laparoscopic-assisted Seldinger technique (LAST) for peritoneal dialysis catheter insertion, highlighting a combination of the Seldinger method's minimal invasiveness with the enhanced visualization of laparoscopy. LAST allows precise catheter placement, making it especially suitable for patients with prior abdominal surgery or those requiring urgent-start PD. This technique enables patients to initiate PD within a day of catheter insertion. The post-surgical protocol involves a gradual increase in dialysate volume, allowing patients to achieve a full PD dose by day five while maintaining controlled peritoneal pressure and minimizing the risk of dialysate leaks. By integrating laparoscopic visualization with the minimally invasive Seldinger technique, LAST has the potential to offer a superior alternative to traditional methods
- 23 May 2025
- Published by MyJove Corporation
- No. 219,p. e67988
JoVE Video Dataset
The management of kidney failure has advanced considerably, with peritoneal dialysis (PD) established as a reliable treatment option that uses the peritoneal membrane to remove excess fluid and toxins. PD has shown particular benefits in the initial stages of treatment, potentially leading to better outcomes compared to hemodialysis. Successful PD, however, depends heavily on the correct placement of the PD catheter. This study presents a protocol to perform the laparoscopic-assisted Seldinger technique (LAST) for peritoneal dialysis catheter insertion, highlighting a combination of the Seldinger method's minimal invasiveness with the enhanced visualization of laparoscopy. LAST allows precise catheter placement, making it especially suitable for patients with prior abdominal surgery or those requiring urgent-start PD. This technique enables patients to initiate PD within a day of catheter insertion. The post-surgical protocol involves a gradual increase in dialysate volume, allowing patients to achieve a full PD dose by day five while maintaining controlled peritoneal pressure and minimizing the risk of dialysate leaks. By integrating laparoscopic visualization with the minimally invasive Seldinger technique, LAST has the potential to offer a superior alternative to traditional methods
- 23 May 2025
- Published by MyJove Corporation
- No. 219,p. e67988
JoVE Video Dataset
The management of kidney failure has advanced considerably, with peritoneal dialysis (PD) established as a reliable treatment option that uses the peritoneal membrane to remove excess fluid and toxins. PD has shown particular benefits in the initial stages of treatment, potentially leading to better outcomes compared to hemodialysis. Successful PD, however, depends heavily on the correct placement of the PD catheter. This study presents a protocol to perform the laparoscopic-assisted Seldinger technique (LAST) for peritoneal dialysis catheter insertion, highlighting a combination of the Seldinger method's minimal invasiveness with the enhanced visualization of laparoscopy. LAST allows precise catheter placement, making it especially suitable for patients with prior abdominal surgery or those requiring urgent-start PD. This technique enables patients to initiate PD within a day of catheter insertion. The post-surgical protocol involves a gradual increase in dialysate volume, allowing patients to achieve a full PD dose by day five while maintaining controlled peritoneal pressure and minimizing the risk of dialysate leaks. By integrating laparoscopic visualization with the minimally invasive Seldinger technique, LAST has the potential to offer a superior alternative to traditional methods
- 5 May 2023
- Published by Elsevier in Transplantation Proceedings
- Vol. 55 (4) , 888-892
Single-Center Experience in Managing Right Liver Grafts From Trifurcation or Independent Right Posterior Portal Vein in Adult Living Donor Liver Transplantation
- 5 May 2023
- Published by Elsevier in Transplantation Proceedings
- Vol. 55 (4) , 888-892
Single-Center Experience in Managing Right Liver Grafts From Trifurcation or Independent Right Posterior Portal Vein in Adult Living Donor Liver Transplantation
- 29 April 2023
- Published by Elsevier in Transplantation Proceedings
- Vol. 55 (4) , 878-883
Optimizing the Safe Washout Period for Liver Transplantation Following Immune Checkpoint Inhibitors with Atezolizumab, Nivolumab, or Pembrolizumab
- 29 April 2023
- Published by Elsevier in Transplantation Proceedings
- Vol. 55 (4) , 878-883
Optimizing the Safe Washout Period for Liver Transplantation Following Immune Checkpoint Inhibitors with Atezolizumab, Nivolumab, or Pembrolizumab
- Open Access
- 21 October 2022
- Published by Wolters Kluwer Health in Journal of the Chinese Medical Association
- Vol. 86 (1) , 65-71
The strategy of diminishing age gap effect on different donor-recipient combinations in living donor kidney transplantation
Background: The disparity between kidney donation and the number of uremic patients on the waiting list has increased the demand for older live-donor kidneys (OLK). However, the donor-recipient age gap may have an impact on the recipient’s outcome. Methods: Patients who underwent living donor kidney transplantation at our institute between 2005 and 2019 were enrolled and categorized into four donor-recipient groups according to age (≥50 years and p = 0.014) and rejection (adjusted HR, 4.26; 95% CI, 1.36-13.37; p = 0.013) were significant risk factors for overall and death-censored graft survival, respectively. Recipients with pretransplant diabetes or prior solid organ transplantation could have amplified risk effects. The main causes of graft loss were death in older recipients and chronic rejection in younger recipients. Conclusion: OLK is safe for young recipients. Nevertheless, adequate immunosuppression should be maintained to prevent rejection and subsequent graft loss, especially for those receiving second kidney transplantation. In contrast, older recipients should avoid overt immunosuppression and control their comorbidities, such as diabetes-related complications to improve their long-term outcomes.
- 21 October 2022
- Published by Wolters Kluwer Health in Journal of the Chinese Medical Association
- Vol. 86 (1) , 65-71
Open AccessThe strategy of diminishing age gap effect on different donor-recipient combinations in living donor kidney transplantation
Background: The disparity between kidney donation and the number of uremic patients on the waiting list has increased the demand for older live-donor kidneys (OLK). However, the donor-recipient age gap may have an impact on the recipient’s outcome. Methods: Patients who underwent living donor kidney transplantation at our institute between 2005 and 2019 were enrolled and categorized into four donor-recipient groups according to age (≥50 years and p = 0.014) and rejection (adjusted HR, 4.26; 95% CI, 1.36-13.37; p = 0.013) were significant risk factors for overall and death-censored graft survival, respectively. Recipients with pretransplant diabetes or prior solid organ transplantation could have amplified risk effects. The main causes of graft loss were death in older recipients and chronic rejection in younger recipients. Conclusion: OLK is safe for young recipients. Nevertheless, adequate immunosuppression should be maintained to prevent rejection and subsequent graft loss, especially for those receiving second kidney transplantation. In contrast, older recipients should avoid overt immunosuppression and control their comorbidities, such as diabetes-related complications to improve their long-term outcomes.
- 16 May 2022
- Published by Wiley in Clinical Transplantation
- Vol. 36 (7) , e14691
Minimal invasive treatment for post‐liver and renal transplant lymphatic leaks
Introduction: Persistent lymphatic leakage from the surgical drain is a troubling complication occasionally encountered postoperatively. This study investigated lymphatic leaks after renal or liver transplantation, comparing the treatment efficacy of traditional catheter drainage vs. minimally invasive lymphatic interventions. We also discuss access and treatment targets considering the physiology of lymphatic flow.Methods: Between September 2018 and September 2020, 13 patients with lymphatic leakage were treated with minimally invasive lymphatic interventions; 11 had received a renal transplant, and two received a liver transplant. The control group included 10 patients with postrenal transplant lymphatic leakage treated with catheter drainage. The treatment efficacy of catheter drainage, lymphatic interventions, and different targets of embolization were compared.Results: The technical success rate for lymphatic intervention was 100%, and the clinical success rate was 92%, with an 82.9% reduction in drain volume on the first day after treatment. The duration to reach clinical success was 5.9 days with lymphatic intervention, and 33.9 days with conservative catheter drainage.Conclusion: Lymphangiography and embolization are minimally invasive and efficient procedures for treating persistent lymphatic leaks after renal or liver transplantation. We suggest prompt diagnosis and embolization at upstream lymphatics to reduce the duration of drain retention, days of hospitalization, and associated comorbidities.
- 16 May 2022
- Published by Wiley in Clinical Transplantation
- Vol. 36 (7) , e14691
Minimal invasive treatment for post‐liver and renal transplant lymphatic leaks
Introduction: Persistent lymphatic leakage from the surgical drain is a troubling complication occasionally encountered postoperatively. This study investigated lymphatic leaks after renal or liver transplantation, comparing the treatment efficacy of traditional catheter drainage vs. minimally invasive lymphatic interventions. We also discuss access and treatment targets considering the physiology of lymphatic flow.Methods: Between September 2018 and September 2020, 13 patients with lymphatic leakage were treated with minimally invasive lymphatic interventions; 11 had received a renal transplant, and two received a liver transplant. The control group included 10 patients with postrenal transplant lymphatic leakage treated with catheter drainage. The treatment efficacy of catheter drainage, lymphatic interventions, and different targets of embolization were compared.Results: The technical success rate for lymphatic intervention was 100%, and the clinical success rate was 92%, with an 82.9% reduction in drain volume on the first day after treatment. The duration to reach clinical success was 5.9 days with lymphatic intervention, and 33.9 days with conservative catheter drainage.Conclusion: Lymphangiography and embolization are minimally invasive and efficient procedures for treating persistent lymphatic leaks after renal or liver transplantation. We suggest prompt diagnosis and embolization at upstream lymphatics to reduce the duration of drain retention, days of hospitalization, and associated comorbidities.
- 13 March 2022
- Published by Elsevier in Journal of Pediatric Surgery
- Vol. 57 (7) , 1210-1214
Advanced preoperative three-dimensional planning decreases the surgical complications of using large-for-size grafts in pediatric living donor liver transplantation
- 13 March 2022
- Published by Elsevier in Journal of Pediatric Surgery
- Vol. 57 (7) , 1210-1214
Advanced preoperative three-dimensional planning decreases the surgical complications of using large-for-size grafts in pediatric living donor liver transplantation
- 1 July 2021
- Published by Elsevier in Journal of Pediatric Surgery
- Vol. 56 (7) , 1162-1168
The feasibility of medial segment graft in pediatric liver transplantation revisited by three-dimensional printing
- 1 July 2021
- Published by Elsevier in Journal of Pediatric Surgery
- Vol. 56 (7) , 1162-1168
The feasibility of medial segment graft in pediatric liver transplantation revisited by three-dimensional printing
- 1 April 2016
- Published by Elsevier in Transplantation Proceedings
- Vol. 48 (3) , 924-928
How to Improve the Positive Predictive Value of Urinary Decoy Cell Surveillance for Polyomavirus BK-Associated Nephropathy in Kidney Transplant Patients
- 1 April 2016
- Published by Elsevier in Transplantation Proceedings
- Vol. 48 (3) , 924-928
How to Improve the Positive Predictive Value of Urinary Decoy Cell Surveillance for Polyomavirus BK-Associated Nephropathy in Kidney Transplant Patients
- 7 December 2010
- Published by IOP Publishing in Nanotechnology
- Vol. 22 (2) , 025201
A GaN photonic crystal membrane laser
The implementation of a series of optically pumped GaN photonic crystal (PhC) membrane lasers is demonstrated at room temperature. The photonic crystal is composed of a scalene-triangular arrangement of circular holes in GaN. Three defect structures are fabricated for comparing their lasing characteristics with those of perfect PhC. It is observed that all the lasing defect modes have lasing wavelengths very close to the band-edge modes in the perfect PhC structure. Although those lasing modes, including band-edge and defect modes, have different optical pump thresholds, different lasing spectral widths, different quality factors (Q factors), and different polarization ratios, all their polarization distributions show maxima in the directions around one of the hole arrangement axes. The similar lasing characteristics between the band-edge and defect modes are attributed to the existence of extremely narrow partial band gaps for forming the defect modes. Also, the oriented polarization properties are due to the scalene-triangle PhC structure. In one of the defect lasing modes, the lasing threshold is as low as 0.82 mJ cm(-2), the cavity Q factor is as large as 1743, and the polarization ratio is as large as 25.4. Such output parameters represent generally superior lasing behaviors when compared with previously reported implementations of similar laser structures.
- 7 December 2010
- Published by IOP Publishing in Nanotechnology
- Vol. 22 (2) , 025201
A GaN photonic crystal membrane laser
The implementation of a series of optically pumped GaN photonic crystal (PhC) membrane lasers is demonstrated at room temperature. The photonic crystal is composed of a scalene-triangular arrangement of circular holes in GaN. Three defect structures are fabricated for comparing their lasing characteristics with those of perfect PhC. It is observed that all the lasing defect modes have lasing wavelengths very close to the band-edge modes in the perfect PhC structure. Although those lasing modes, including band-edge and defect modes, have different optical pump thresholds, different lasing spectral widths, different quality factors (Q factors), and different polarization ratios, all their polarization distributions show maxima in the directions around one of the hole arrangement axes. The similar lasing characteristics between the band-edge and defect modes are attributed to the existence of extremely narrow partial band gaps for forming the defect modes. Also, the oriented polarization properties are due to the scalene-triangle PhC structure. In one of the defect lasing modes, the lasing threshold is as low as 0.82 mJ cm(-2), the cavity Q factor is as large as 1743, and the polarization ratio is as large as 25.4. Such output parameters represent generally superior lasing behaviors when compared with previously reported implementations of similar laser structures.