Thomas Skårup Kristensen
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Thomas Skårup Kristensen has a total of 37 co-authors. Here are the top co-authors by number of shared publications:
- Andreas Ronit
Department of Infectious Diseases, Copenhagen University Hospital - Rigshospitalet , Copenhagen
1 shared publication - Anna Kalhauge
Department of Radiology, Copenhagen University Hospital – Rigshospitalet, Copenhagen, Denmark
1 shared publication Anna Sundberg
Centre for Physical Activity Research (CFAS), Rigshospitalet, University of Copenhagen, Blegdamsvej 9, DK-2100 Copenhagen, Denmark
1 shared publication- Annika Loft
Department of Clinical Physiology, Nuclear Medicine and PET, Rigshospitalet, Copenhagen University Hospital, Blegdamsvej 9, 2100 Copenhagen, Denmark
1 shared publication - Annika Reynberg Langkilde
Department of Radiology, Copenhagen University Hospital Rigshospitalet, 2100 Copenhagen, Denmark
1 shared publication - Bojan Kovacevic
Copenhagen University Hospital, Denmark
1 shared publication
Latest Publications
- Open Access
- 27 January 2026
- Published by MDPI AG in Diagnostics
- Vol. 16 (3) , 398
First Clinical Experiences with the Ultra-Fast Time-of-Flight BIOGRAPH One Next-Generation Hybrid PET/MRI System
Objective : We present the first clinical experience with the BIOGRAPH One next-generation PET/MRI system scanner, evaluating its performance for body and brain imaging in patients across multiple tracers. Methods: A total of 59 patients were scanned on the BIOGRAPH One PET/MRI following standard clinical PET/CT (n = 52) or first-generation PET/MRI (Biograph mMR, n = 7). Scans comprised 30 total body (TB), whole body (WB), or regional scans with [18F]FDG, and 29 brain scans with either [18F]FDG (n = 5), [18F]FE-PE2I (n = 10), [18F]FET (n = 4), or [68Ga]Ga-DOTATOC (n = 10). The PET image quality was visually assessed using a 5-point Likert scale (1 = very good to 5 = very bad) and compared with clinical scans acquired on either a current-generation digital PET/CT or a first-generation PET/MRI system, including evaluation of diagnostic concordance. PET quantification and image noise was compared in brain and WB/TB [18F]FDG PET scans. Results: PET image quality was rated as good or very good in 93% of scans with a median [inter-quartile range] score of 1.5 [1.5;2]. In 99% of cases, image quality was judged equal to or better than the clinical reference scan (median score 3 [2.5;3]). Diagnostic concordance was observed in 99% of readings. Imaging metrics revealed the anticipated regional bias in brain imaging, while no significant bias was observed in body imaging. Image noise was comparable to that observed with digital PET/CT and demonstrated superiority over first-generation PET/MRI despite potential degradation related to isotope decay in BIOGRAPH One PET/MRI acquisitions scans performed at the end of the imaging workflow. Conclusions: Within the study limitations related to sequential imaging, the BIOGRAPH One PET/MRI scanner demonstrated improved PET sensitivity and workflow potential over its first-generation predecessor, which may allow for broader clinical and research applications.
- 27 January 2026
- Published by MDPI AG in Diagnostics
- Vol. 16 (3) , 398
Open AccessFirst Clinical Experiences with the Ultra-Fast Time-of-Flight BIOGRAPH One Next-Generation Hybrid PET/MRI System
Objective : We present the first clinical experience with the BIOGRAPH One next-generation PET/MRI system scanner, evaluating its performance for body and brain imaging in patients across multiple tracers. Methods: A total of 59 patients were scanned on the BIOGRAPH One PET/MRI following standard clinical PET/CT (n = 52) or first-generation PET/MRI (Biograph mMR, n = 7). Scans comprised 30 total body (TB), whole body (WB), or regional scans with [18F]FDG, and 29 brain scans with either [18F]FDG (n = 5), [18F]FE-PE2I (n = 10), [18F]FET (n = 4), or [68Ga]Ga-DOTATOC (n = 10). The PET image quality was visually assessed using a 5-point Likert scale (1 = very good to 5 = very bad) and compared with clinical scans acquired on either a current-generation digital PET/CT or a first-generation PET/MRI system, including evaluation of diagnostic concordance. PET quantification and image noise was compared in brain and WB/TB [18F]FDG PET scans. Results: PET image quality was rated as good or very good in 93% of scans with a median [inter-quartile range] score of 1.5 [1.5;2]. In 99% of cases, image quality was judged equal to or better than the clinical reference scan (median score 3 [2.5;3]). Diagnostic concordance was observed in 99% of readings. Imaging metrics revealed the anticipated regional bias in brain imaging, while no significant bias was observed in body imaging. Image noise was comparable to that observed with digital PET/CT and demonstrated superiority over first-generation PET/MRI despite potential degradation related to isotope decay in BIOGRAPH One PET/MRI acquisitions scans performed at the end of the imaging workflow. Conclusions: Within the study limitations related to sequential imaging, the BIOGRAPH One PET/MRI scanner demonstrated improved PET sensitivity and workflow potential over its first-generation predecessor, which may allow for broader clinical and research applications.
- Open Access
- 23 November 2024
- Published by Elsevier in Pancreatology
- Vol. 25 (2) , 228-233
Progression of resectable pancreatic ductal adenocarcinoma during surgical delay and effects on survival – A propensity score matched study
- 23 November 2024
- Published by Elsevier in Pancreatology
- Vol. 25 (2) , 228-233
Open AccessProgression of resectable pancreatic ductal adenocarcinoma during surgical delay and effects on survival – A propensity score matched study
- Open Access
- 4 November 2022
- Published by Oxford University Press (OUP) in Open Forum Infectious Diseases
- Vol. 9 (11) , ofac596
Lung Abnormalities in Severe Acute Respiratory Syndrome Coronavirus 2 Infection: An Analysis of Paired Computed Tomography Scans Before and After Infection
Studies on the pulmonary consequences of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) infection are impeded by limited access to pre–SARS-CoV-2 examinations. We invited Copenhagen General Population Study participants with a confirmed SARS-CoV-2 polymerase chain reaction (PCR) test during the first and second coronavirus disease 2019 waves in Denmark for a repeat chest computed tomography (CT) scan. Paired CT scans were independently assessed for interstitial and noninterstitial abnormalities by 2 trained radiologists. A semiquantitative CT score (ranging from 0 to 20) was used to quantify the extent of interstitial abnormalities. Of 111 SARS-CoV-2–infected individuals, 102 (91.2%) experienced symptoms and 12 (11.2%) were hospitalized. Follow-up examination was performed at median of 5.4 (interquartile range, 4.1–7.8) months after a positive SARS-CoV-2 PCR test. Of 67 individuals with paired CT scans, ground glass opacities and reticulation were present in 31 (46.3%) individuals post–SARS-CoV-2 compared to 23 (34.1%) pre–SARS-CoV-2 (mean CT score, 3.0 vs 1.3; P = .011). Results were similar for nonhospitalized individuals. We did not detect development of bronchiectasis, emphysema, or nodules. SARS-CoV-2 infection in predominantly nonhospitalized individuals with mild disease was associated with a small increase in only interstitial lung abnormalities.
- 4 November 2022
- Published by Oxford University Press (OUP) in Open Forum Infectious Diseases
- Vol. 9 (11) , ofac596
Open AccessLung Abnormalities in Severe Acute Respiratory Syndrome Coronavirus 2 Infection: An Analysis of Paired Computed Tomography Scans Before and After Infection
Studies on the pulmonary consequences of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) infection are impeded by limited access to pre–SARS-CoV-2 examinations. We invited Copenhagen General Population Study participants with a confirmed SARS-CoV-2 polymerase chain reaction (PCR) test during the first and second coronavirus disease 2019 waves in Denmark for a repeat chest computed tomography (CT) scan. Paired CT scans were independently assessed for interstitial and noninterstitial abnormalities by 2 trained radiologists. A semiquantitative CT score (ranging from 0 to 20) was used to quantify the extent of interstitial abnormalities. Of 111 SARS-CoV-2–infected individuals, 102 (91.2%) experienced symptoms and 12 (11.2%) were hospitalized. Follow-up examination was performed at median of 5.4 (interquartile range, 4.1–7.8) months after a positive SARS-CoV-2 PCR test. Of 67 individuals with paired CT scans, ground glass opacities and reticulation were present in 31 (46.3%) individuals post–SARS-CoV-2 compared to 23 (34.1%) pre–SARS-CoV-2 (mean CT score, 3.0 vs 1.3; P = .011). Results were similar for nonhospitalized individuals. We did not detect development of bronchiectasis, emphysema, or nodules. SARS-CoV-2 infection in predominantly nonhospitalized individuals with mild disease was associated with a small increase in only interstitial lung abnormalities.
- 1 May 2021
- Published by Elsevier in Clinical Nutrition
- Vol. 40 (5) , 2809-2816
Assessment of sarcopenia in patients with upper gastrointestinal tumors: Prevalence and agreement between computed tomography and dual-energy x-ray absorptiometry
- 1 May 2021
- Published by Elsevier in Clinical Nutrition
- Vol. 40 (5) , 2809-2816
Assessment of sarcopenia in patients with upper gastrointestinal tumors: Prevalence and agreement between computed tomography and dual-energy x-ray absorptiometry