SBSükrü Bayraktar

Sükrü Bayraktar

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Sükrü Bayraktar has a total of 9 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Intraocular pressure control after clear corneal phacoemulsification in eyes with previous trabeculectomy: a controlled study

    by Asli Inal, Sükrü Bayraktar, Berkay Inal, Zerrin Bayraktar, Ömer Faruk Yilmaz

    : Purpose:  To compare intraocular pressure (IOP) control in eyes with or without clear corneal phacoemulsification following trabeculectomy. Methods:  The study group included 30 eyes that underwent uneventful clear corneal phacoemulsification and foldable intraocular lens implantation following trabeculectomy without antimetabolites. Thirty eyes that had undergone filtering surgery without cataract extraction were selected as controls. Case and control groups were matched with respect to age, gender, IOP, number of glaucoma medications, glaucoma type (primary open‐angle glaucoma/ pseudoexfoliative glaucoma), trabeculectomy time and follow‐up. Comparisons between the study and control groups (intergroup) and within the same group at different time‐points (intragroup) were performed for IOP, glaucoma medications and bleb morphology. Success rates were investigated by Kaplan−Meier survival analysis and the factors influencing final success by logistic regression. Results:  Intraocular pressure (p = 0.04) and glaucoma medications (p = 0.001) increased during an average follow‐up of 26.1 ± 9.9 months in both groups. Intragroup differences became statistically significant after the 6‐month visit, but intergroup differences remained insignificant. Bleb height decreased significantly following phacoemulsification in the study group (p = 0.017). Success rates decreased with time in both groups, with no intergroup difference (p = 0.46). The final success rate was negatively correlated with IOP and number of glaucoma medications used at the study entry, while there was a positive correlation between the baseline and final success rates. Conclusion:  Trabeculectomy success decreased in a time‐dependent manner in eyes with and without subsequent phacoemulsification. Uncomplicated clear corneal phacoemulsification was not found to have any additional unfavorable influence on IOP control in eyes with filtering blebs.


  • Central Corneal Thickness and Intraocular Pressure Relationship in Eyes with and without Previous LASIK: Comparison of Goldmann Applanation Tonometer with Pneumatonometer

    by Ş. Bayraktar, Z. Bayraktar

    Purpose: To investigate central corneal thickness (CCT) and intraocular pressure (IOP) relationship in eyes with and without previous corneal laser refractive surgery and to compare the estimates of two different tonometers–Goldmann applanation and pneumatonometer. Methods: The study population included 234 glaucoma suspects who were referred to the glaucoma clinic with cup/disc ratios greater than 0.4, asymmetric cupping, and/or IOP greater than 22 mmHg during routine eye examination. Of those, 84 had previous myopic laser-assisted in situ keratomileusis (LASIK) (Group 1) while 150 of them did not (Group 2). CCT was measured by using optical coherence tomography (OCT) and IOP with both Goldmann applanation tonometer (GAT) and pneumatonometer (PT). In both groups, the difference between IOP estimates of two different tonometers and the relationship between CCT and IOP were analyzed. Results: In eyes with previous LASIK, GAT measured IOP significantly lower than PT (mean difference of 3.8±1.9 mmHg, p<0.0001). In eyes with virgin corneas, IOP estimates of GAT or PT were not different from each other (19.9±2.8 versus 19.9±2.2 mmHg, respectively, p=0.81). In both groups, there was a significant positive correlation between CCT and IOP estimates of GAT (R=0.29, p=0.007 in eyes with LASIK and R=0.38, p<0.0001 in those without), while no similar relationship was present between CCT with those of PT (R=0.03, p=0.76 in eyes with LASIK and R=0.03, p=0.69 in those without). Conclusions: In eyes with previous LASIK, GAT measured IOP significantly lower than PT. Because IOP estimates of PT were found to be independent from CCT in all of the study eyes, this device was considered to be a more reliable method of IOP estimation than GAT in eyes with and without previous LASIK.