Kung-Bin Sung
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Kung-Bin Sung has a total of 125 co-authors. Here are the top co-authors by number of shared publications:
Yang-Hsien Lin
4 shared publications- Chii-Wann Lin
National Taiwan University
3 shared publications Hao-Wei Lee
Graduate Institute of Biomedical Electronics and Bioinformatics, National Taiwan Universityhttps://ror.org/05bqach95, Taipei 106319, Taiwan
3 shared publicationsJing-Wei Su
Institute of Biomedical Electronics and Bioinformatics, National Taiwan University, Taiwan
3 shared publicationsLi-Da Huang
CytonSys Inc
3 shared publications- Shih-Chung Wei
National University of Singapore
3 shared publications
Latest Publications
- 1 October 2026
- Published by SPIE-Intl Soc Optical Eng
- p. 23
Non-invasive quantification of optical properties of the human head by combining continuous-wave and time-resolved near-infrared spectroscopy systems
The combination of the cost-effective, multi-wavelength capabilities of continuous-wave (CW) near-infrared spectroscopy (NIRS) and the depth-sensitivity of time-resolved (TR) NIRS improves the quantification of head tissue optical properties (OPs) non-invasively.
- 1 October 2026
- Published by SPIE-Intl Soc Optical Eng
- p. 23
Non-invasive quantification of optical properties of the human head by combining continuous-wave and time-resolved near-infrared spectroscopy systems
The combination of the cost-effective, multi-wavelength capabilities of continuous-wave (CW) near-infrared spectroscopy (NIRS) and the depth-sensitivity of time-resolved (TR) NIRS improves the quantification of head tissue optical properties (OPs) non-invasively.
- 3 November 2025
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 16 (12) , 4929-4943
Noninvasive prediction of photon fluence rate in targeted brain regions for personalized transcranial photobiomodulation dosage: model development and in silico evaluation
Transcranial photobiomodulation (tPBM) shows promise in delivering beneficial effects to the brain. However, accurately estimating the stimulus energy reaching the targeted brain region remains difficult due to individual differences in anatomy and optical properties. We present a noninvasive method that combines diffuse reflectance spectroscopy with deep learning to predict the fluence rate of the stimulus light. Incorporating tissue layer thicknesses into the model significantly enhances prediction accuracy, reducing errors to approximately 13%, compared to 49% when assuming a constant irradiance at the scalp surface. By eliminating the need for expensive magnetic resonance imaging, our approach offers a scalable solution for optimizing irradiation parameters in future tPBM applications.
- 3 November 2025
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 16 (12) , 4929-4943
Noninvasive prediction of photon fluence rate in targeted brain regions for personalized transcranial photobiomodulation dosage: model development and in silico evaluation
Transcranial photobiomodulation (tPBM) shows promise in delivering beneficial effects to the brain. However, accurately estimating the stimulus energy reaching the targeted brain region remains difficult due to individual differences in anatomy and optical properties. We present a noninvasive method that combines diffuse reflectance spectroscopy with deep learning to predict the fluence rate of the stimulus light. Incorporating tissue layer thicknesses into the model significantly enhances prediction accuracy, reducing errors to approximately 13%, compared to 49% when assuming a constant irradiance at the scalp surface. By eliminating the need for expensive magnetic resonance imaging, our approach offers a scalable solution for optimizing irradiation parameters in future tPBM applications.
- 20 March 2025
- Published by SPIE-Intl Soc Optical Eng
- Vol. 13314, 21
Investigating chromophore changes in bruised skin In vivo using diffuse reflectance spectroscopy and Monte Carlo simulation (Conference Presentation)
Evaluating bruise age is crucial in forensic and medical contexts. This study presents a non-contact system using Diffuse Reflectance Spectroscopy (DRS) and Monte Carlo (MC) simulations to analyze chromophore changes in bruised skin. Measuring multiple sites improves accuracy and convenience over traditional methods. Using a broad-band visible light source (450-600 nm) and a three-layer skin model, the Modified Beer-Lambert Law (MBLL) calculated changes in optical density (ΔOD) and absorption coefficients (Δμa), estimating relative chromophore concentration changes. This method enhances non-invasive bruise age assessment for forensic and clinical evaluations.
- 20 March 2025
- Published by SPIE-Intl Soc Optical Eng
- Vol. 13314, 21
Investigating chromophore changes in bruised skin In vivo using diffuse reflectance spectroscopy and Monte Carlo simulation (Conference Presentation)
Evaluating bruise age is crucial in forensic and medical contexts. This study presents a non-contact system using Diffuse Reflectance Spectroscopy (DRS) and Monte Carlo (MC) simulations to analyze chromophore changes in bruised skin. Measuring multiple sites improves accuracy and convenience over traditional methods. Using a broad-band visible light source (450-600 nm) and a three-layer skin model, the Modified Beer-Lambert Law (MBLL) calculated changes in optical density (ΔOD) and absorption coefficients (Δμa), estimating relative chromophore concentration changes. This method enhances non-invasive bruise age assessment for forensic and clinical evaluations.
- 8 May 2024
- Published by Optica Publishing Group in Optics Letters
- Vol. 49 (10) , 2669-2672
Quantifying changes in oxygen saturation of the internal jugular vein in vivo using deep neural networks and subject-specific three-dimensional Monte Carlo models
Central venous oxygen saturation (ScvO2) is an important parameter for assessing global oxygen usage and guiding clinical interventions. However, measuring ScvO2 requires invasive catheterization. As an alternative, we aim to noninvasively and continuously measure changes in oxygen saturation of the internal jugular vein (SijvO2) by a multi-channel near-infrared spectroscopy system. The relation between the measured reflectance and changes in SijvO2 is modeled by Monte Carlo simulations and used to build a prediction model using deep neural networks (DNNs). The prediction model is tested with simulated data to show robustness to individual variations in tissue optical properties. The proposed technique is promising to provide a noninvasive tool for monitoring the stability of brain oxygenation in broad patient populations.
- 8 May 2024
- Published by Optica Publishing Group in Optics Letters
- Vol. 49 (10) , 2669-2672
Quantifying changes in oxygen saturation of the internal jugular vein in vivo using deep neural networks and subject-specific three-dimensional Monte Carlo models
Central venous oxygen saturation (ScvO2) is an important parameter for assessing global oxygen usage and guiding clinical interventions. However, measuring ScvO2 requires invasive catheterization. As an alternative, we aim to noninvasively and continuously measure changes in oxygen saturation of the internal jugular vein (SijvO2) by a multi-channel near-infrared spectroscopy system. The relation between the measured reflectance and changes in SijvO2 is modeled by Monte Carlo simulations and used to build a prediction model using deep neural networks (DNNs). The prediction model is tested with simulated data to show robustness to individual variations in tissue optical properties. The proposed technique is promising to provide a noninvasive tool for monitoring the stability of brain oxygenation in broad patient populations.
- 13 March 2024
- Published by SPIE-Intl Soc Optical Eng
- Vol. PC12833, PC1283303
High-fidelity quantification of changes in blood oxygen saturation of the internal jugular vein by accelerated Monte-Carlo based models
This study aims to develop a high-fidelity prediction model based on artificial neural networks to quantify changes in blood oxygen saturation of the internal jugular vein (IJV) (ΔSijvO2) from the pulsatile component of diffuse reflectance spectra measured non-invasively from the neck surface above the IJV. Training and testing data are generated using a surrogate model, which is millions of times faster than the original Monte Carlo simulations. We have investigated the model’s resilience to measurement noise, changes in surrounding tissue’s oxygen saturation, and fluctuations in IJV’s depth and size due to respiration. Results of validating the prediction model by simulated data have exhibited root mean square errors of less than 4%. Finally, validation of the prediction model on healthy subjects performing the Valsalva maneuver in vivo has demonstrated agreements between predicted results and expected physiological responses.
- 13 March 2024
- Published by SPIE-Intl Soc Optical Eng
- Vol. PC12833, PC1283303
High-fidelity quantification of changes in blood oxygen saturation of the internal jugular vein by accelerated Monte-Carlo based models
This study aims to develop a high-fidelity prediction model based on artificial neural networks to quantify changes in blood oxygen saturation of the internal jugular vein (IJV) (ΔSijvO2) from the pulsatile component of diffuse reflectance spectra measured non-invasively from the neck surface above the IJV. Training and testing data are generated using a surrogate model, which is millions of times faster than the original Monte Carlo simulations. We have investigated the model’s resilience to measurement noise, changes in surrounding tissue’s oxygen saturation, and fluctuations in IJV’s depth and size due to respiration. Results of validating the prediction model by simulated data have exhibited root mean square errors of less than 4%. Finally, validation of the prediction model on healthy subjects performing the Valsalva maneuver in vivo has demonstrated agreements between predicted results and expected physiological responses.
- 20 September 2023
- Published by SPIE-Intl Soc Optical Eng
- Vol. 12608, 193-194
Optimizing transcranial infrared light stimulation for cognitive function enhancement: near-infrared spectroscopy approaches
We study effects of long-term transcranial infrared light stimulation on cognitive functions of the elders. The fraction of photon energy penetrating to the brain is estimated noninvasively to enable the optimization of light source parameters.
- 20 September 2023
- Published by SPIE-Intl Soc Optical Eng
- Vol. 12608, 193-194
Optimizing transcranial infrared light stimulation for cognitive function enhancement: near-infrared spectroscopy approaches
We study effects of long-term transcranial infrared light stimulation on cognitive functions of the elders. The fraction of photon energy penetrating to the brain is estimated noninvasively to enable the optimization of light source parameters.
- 6 March 2023
- Published by SPIE-Intl Soc Optical Eng
- Vol. PC12370, 15
Non-invasive quantification of changes in blood oxygen saturation of the internal jugular vein: theoretical evaluation and in-vivo demonstration (Conference Presentation)
A prediction model based on artificial neural networks was built to quantify changes in blood oxygen saturation of the internal jugular vein (dSijvO2) from diffuse reflectance measured at five wavelengths. The model was trained by Monte Carlo simulations with various tissue optical coefficients and subject-specific tissue structure determined by ultrasound imaging. Errors in dSijvO2 estimated from simulated data are below 2.2% and independent of the initial oxygen saturation. The model was further validated by excellent agreements between modeled and measured in-vivo reflectance spectra from a healthy volunteer undergoing hyperventilation, and the quantified trend of dSijvO2 followed expectations during and after hyperventilation. The proposed method is promising to provide non-invasive quantification of dSijvO2.
- 6 March 2023
- Published by SPIE-Intl Soc Optical Eng
- Vol. PC12370, 15
Non-invasive quantification of changes in blood oxygen saturation of the internal jugular vein: theoretical evaluation and in-vivo demonstration (Conference Presentation)
A prediction model based on artificial neural networks was built to quantify changes in blood oxygen saturation of the internal jugular vein (dSijvO2) from diffuse reflectance measured at five wavelengths. The model was trained by Monte Carlo simulations with various tissue optical coefficients and subject-specific tissue structure determined by ultrasound imaging. Errors in dSijvO2 estimated from simulated data are below 2.2% and independent of the initial oxygen saturation. The model was further validated by excellent agreements between modeled and measured in-vivo reflectance spectra from a healthy volunteer undergoing hyperventilation, and the quantified trend of dSijvO2 followed expectations during and after hyperventilation. The proposed method is promising to provide non-invasive quantification of dSijvO2.
- 30 January 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Selected Topics in Quantum Electronics
- Vol. 29 (4: Biophot) , 1-10
Long-Term Photobiomodulation of Cellular and Mitochondrial Activities in IMR-32 Cells Using an 810 nm Light-Emitting Diode
In photobiomodulation (PBM), biological tissues are stimulated using low-energy light. Mitochondria are thought to be integral to the process, and PBM effects vary with light parameters. Biphasic curves are commonly used to describe the dose response of PBM but do not fit in some cases. Dose-dependent PBM effects, especially mitochondrial responses, must be understood to optimize clinical therapies. However, most previous studies have reported short-term mitochondrial activity changes, neglecting long-term effects or dose-dependent changes in whole transcriptomes. We studied the effects of 3-day PBM with an 810 nm circular LED beam on human neuroblastoma IMR-32 cells. Two light doses with opposite effects on mitochondrial DNA copy number were chosen to analyze total RNA, protein content and function of mitochondrial respiratory complexes, and mitochondrial morphology. Daily 15-minute 810 nm light treatment enhanced drug resistance to the mitochondrial inhibitors and uncoupling agent via two distinct mechanisms: 1.40 mW/cm 2 light increased cell proliferation and the proportion of cells in the cell cycle S phase; 1.95 mW/cm 2 light enhanced oxidative phosphorylation at the RNA, protein, and functional levels and the proportion of network-like mitochondria. Our findings reveal the complexity of PBM dose responses and provide insights into light-cell interactions.
- 30 January 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Selected Topics in Quantum Electronics
- Vol. 29 (4: Biophot) , 1-10
Long-Term Photobiomodulation of Cellular and Mitochondrial Activities in IMR-32 Cells Using an 810 nm Light-Emitting Diode
In photobiomodulation (PBM), biological tissues are stimulated using low-energy light. Mitochondria are thought to be integral to the process, and PBM effects vary with light parameters. Biphasic curves are commonly used to describe the dose response of PBM but do not fit in some cases. Dose-dependent PBM effects, especially mitochondrial responses, must be understood to optimize clinical therapies. However, most previous studies have reported short-term mitochondrial activity changes, neglecting long-term effects or dose-dependent changes in whole transcriptomes. We studied the effects of 3-day PBM with an 810 nm circular LED beam on human neuroblastoma IMR-32 cells. Two light doses with opposite effects on mitochondrial DNA copy number were chosen to analyze total RNA, protein content and function of mitochondrial respiratory complexes, and mitochondrial morphology. Daily 15-minute 810 nm light treatment enhanced drug resistance to the mitochondrial inhibitors and uncoupling agent via two distinct mechanisms: 1.40 mW/cm 2 light increased cell proliferation and the proportion of cells in the cell cycle S phase; 1.95 mW/cm 2 light enhanced oxidative phosphorylation at the RNA, protein, and functional levels and the proportion of network-like mitochondria. Our findings reveal the complexity of PBM dose responses and provide insights into light-cell interactions.
- 1 November 2022
- Published by Optica Publishing Group in Applied Optics
- Vol. 61 (32) , 9334-9341
Specific refraction-index increments of oxygenated hemoglobin from thalassemia-minor patients are not significantly different than those from healthy individuals
The mass and concentration of hemoglobin per erythrocyte are important hematological parameters. Measuring these parameters from intact erythrocytes requires the value of specific refraction-index increment (RII) of oxygenated hemoglobin, which diverges in the literature. Refractive indices of hemoglobin solutions are measured directly by digital holographic microscopy on a microfluidic channel filled with hemoglobin solutions prepared by hemolysis of fresh human erythrocytes and refractive-index standards sequentially. Hemoglobin extracted from thalassemic patients shows 3–4% higher RII than that from healthy volunteers, but the difference is not significant in comparison to inter-subject variations within each group. The quantified RIIs are applied to quantify mean corpuscular hemoglobin mass of blood from 37 human subjects, and results are in accord with standard clinical test results.
- 1 November 2022
- Published by Optica Publishing Group in Applied Optics
- Vol. 61 (32) , 9334-9341
Specific refraction-index increments of oxygenated hemoglobin from thalassemia-minor patients are not significantly different than those from healthy individuals
The mass and concentration of hemoglobin per erythrocyte are important hematological parameters. Measuring these parameters from intact erythrocytes requires the value of specific refraction-index increment (RII) of oxygenated hemoglobin, which diverges in the literature. Refractive indices of hemoglobin solutions are measured directly by digital holographic microscopy on a microfluidic channel filled with hemoglobin solutions prepared by hemolysis of fresh human erythrocytes and refractive-index standards sequentially. Hemoglobin extracted from thalassemic patients shows 3–4% higher RII than that from healthy volunteers, but the difference is not significant in comparison to inter-subject variations within each group. The quantified RIIs are applied to quantify mean corpuscular hemoglobin mass of blood from 37 human subjects, and results are in accord with standard clinical test results.