May Jorella Lazaro
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
May Jorella Lazaro has a total of 21 co-authors. Here are the top co-authors by number of shared publications:
- Sungho Kim
Republic of Korea Air Force Academy
8 shared publications Myung Hwan Yun
4 shared publications- Myung Hwan Yun
Department of Industrial Engineering, Seoul National University
4 shared publications Sungho Kim
Seoul Natl Univ, Dept Ind Engn, Seoul, South Korea
3 shared publicationsYohan Kang
Department of Industrial Engineering, Seoul National University, South Korea
3 shared publicationsJaemin Chun
Samsung Electronics Co, Ltd, Seoul, South Korea
2 shared publications
Latest Publications
- Open Access
- 25 April 2025
- Published by Association for Computing Machinery (ACM)
- p. 1-7
Rethinking Heuristics, Are We Heading the Right Way? A Case Study on Heuristic Evaluation in Action
- 25 April 2025
- Published by Association for Computing Machinery (ACM)
- p. 1-7
Open AccessRethinking Heuristics, Are We Heading the Right Way? A Case Study on Heuristic Evaluation in Action
- 17 January 2025
- Published by Taylor & Francis in International Journal of Human–Computer Interaction
- Vol. 41 (17) , 11227-11243
Review of Multimodal Interaction in Optical See-Through Augmented Reality
- 17 January 2025
- Published by Taylor & Francis in International Journal of Human–Computer Interaction
- Vol. 41 (17) , 11227-11243
Review of Multimodal Interaction in Optical See-Through Augmented Reality
- 9 January 2025
- Published by Elsevier in Applied Ergonomics
- Vol. 125, 104457
Development and validation of spatial disorientation scenarios using virtual reality and motion simulator
- 9 January 2025
- Published by Elsevier in Applied Ergonomics
- Vol. 125, 104457
Development and validation of spatial disorientation scenarios using virtual reality and motion simulator
- Open Access
- 2 May 2024
- Published by Association for Computing Machinery (ACM)
- p. 1-7
Mind the Mix: Exploring the Cognitive Underpinnings of Multimodal Interaction in Augmented Reality Systems
Exploring the intricate dynamics of Multimodal Interaction (MMI) in Augmented Reality (AR), this study presents a novel conceptual framework, crafted from a review of cognitive theories. Our research delves into how input modalities, output modalities, and their combinations uniquely influence user experiences in AR environments. Recognizing a gap in the existing MMI literature, especially within the AR context, we propose a conceptual framework to understand these complex relationships. Our framework pinpoints three critical factors: the choice of input modality, the verbal processing code of outputs, and the synergistic effects of input-output combinations. These elements are hypothesized to significantly impact user interaction and performance in AR systems. This work-in-progress not only contributes to the theoretical discourse in HCI but also sets the stage for future empirical investigations, aiming to enhance user-centered design in the evolving field of AR technology.
- 2 May 2024
- Published by Association for Computing Machinery (ACM)
- p. 1-7
Open AccessMind the Mix: Exploring the Cognitive Underpinnings of Multimodal Interaction in Augmented Reality Systems
Exploring the intricate dynamics of Multimodal Interaction (MMI) in Augmented Reality (AR), this study presents a novel conceptual framework, crafted from a review of cognitive theories. Our research delves into how input modalities, output modalities, and their combinations uniquely influence user experiences in AR environments. Recognizing a gap in the existing MMI literature, especially within the AR context, we propose a conceptual framework to understand these complex relationships. Our framework pinpoints three critical factors: the choice of input modality, the verbal processing code of outputs, and the synergistic effects of input-output combinations. These elements are hypothesized to significantly impact user interaction and performance in AR systems. This work-in-progress not only contributes to the theoretical discourse in HCI but also sets the stage for future empirical investigations, aiming to enhance user-centered design in the evolving field of AR technology.
- 19 July 2022
- Published by Elsevier in Applied Ergonomics
- Vol. 105, 103842
Multimodal interaction: Input-output modality combinations for identification tasks in augmented reality
- 19 July 2022
- Published by Elsevier in Applied Ergonomics
- Vol. 105, 103842
Multimodal interaction: Input-output modality combinations for identification tasks in augmented reality
- 29 June 2022
- Published by Taylor & Francis in Ergonomics
- Vol. 66 (4) , 432-442
Galvanic vestibular stimulation to counteract leans illusion: comparing step and ramped waveforms
Leans is a common type of Spatial Disorientation (SD) illusion that causes pilots to be confused about the position of the aircraft during a flight. This illusion could lead to serious adverse effects and even flight mishaps. Therefore, an effective means to deal with leans is crucial for flight safety. This study aims to investigate the effects of Galvanic Vestibular Stimulation (GVS) technology with different waveforms as a tool to mitigate the negative effects of leans. 20 Air Force pilots participated in leans-induced flight simulation experiment with three GVS conditions (without-GVS, step-GVS, ramped-GVS). Bank angle error, subjective SD, perceived strength, and annoyance were measured as the dependent variables. Analysis revealed that step-GVS and ramped-GVS yielded lower bank angle errors and subjective SD than without-GVS. In addition, annoyance ratings were lower for ramped-GVS than step-GVS. This study suggests that GVS has the potential to be utilized as a counteracting tool to cope with leans. Galvanic Vestibular Stimulation (GVS) can be utilized as a tool to counteract the detrimental effects of leans illusion, specifically the ramped style GVS, considering that it is less annoying and distracting for the pilots. In general, GVS induces a roll sensation that can offset the false sensation caused by the leans, which can potentially help maintain flight safety and avoid spatial disorientation-related accidents.
- 29 June 2022
- Published by Taylor & Francis in Ergonomics
- Vol. 66 (4) , 432-442
Galvanic vestibular stimulation to counteract leans illusion: comparing step and ramped waveforms
Leans is a common type of Spatial Disorientation (SD) illusion that causes pilots to be confused about the position of the aircraft during a flight. This illusion could lead to serious adverse effects and even flight mishaps. Therefore, an effective means to deal with leans is crucial for flight safety. This study aims to investigate the effects of Galvanic Vestibular Stimulation (GVS) technology with different waveforms as a tool to mitigate the negative effects of leans. 20 Air Force pilots participated in leans-induced flight simulation experiment with three GVS conditions (without-GVS, step-GVS, ramped-GVS). Bank angle error, subjective SD, perceived strength, and annoyance were measured as the dependent variables. Analysis revealed that step-GVS and ramped-GVS yielded lower bank angle errors and subjective SD than without-GVS. In addition, annoyance ratings were lower for ramped-GVS than step-GVS. This study suggests that GVS has the potential to be utilized as a counteracting tool to cope with leans. Galvanic Vestibular Stimulation (GVS) can be utilized as a tool to counteract the detrimental effects of leans illusion, specifically the ramped style GVS, considering that it is less annoying and distracting for the pilots. In general, GVS induces a roll sensation that can offset the false sensation caused by the leans, which can potentially help maintain flight safety and avoid spatial disorientation-related accidents.
- 11 May 2022
- Published by Audio Engineering Society in Journal of the Audio Engineering Society
- Vol. 70 (4) , 294-304
Design and Evaluation of Electric Vehicle Sound Using Granular Synthesis
Electric vehicles (EVs) generally do not have the natural engine sound; thus, sound design for such vehicles is more crucial. This study focuses on proposing an EV interior sound design through utilizing the granular synthesis method. Moreover, it aims to investigate the effect of each granular synthesis parameter on the drivers' affective experience. In the model proposed, four granular synthesis parameters (sample source, grain duration, grain envelope, and revolution per minute [RPM] range)...
- 11 May 2022
- Published by Audio Engineering Society in Journal of the Audio Engineering Society
- Vol. 70 (4) , 294-304
Design and Evaluation of Electric Vehicle Sound Using Granular Synthesis
Electric vehicles (EVs) generally do not have the natural engine sound; thus, sound design for such vehicles is more crucial. This study focuses on proposing an EV interior sound design through utilizing the granular synthesis method. Moreover, it aims to investigate the effect of each granular synthesis parameter on the drivers' affective experience. In the model proposed, four granular synthesis parameters (sample source, grain duration, grain envelope, and revolution per minute [RPM] range)...
- 25 March 2022
- Published by SAGE Publications in Human Factors: The Journal of the Human Factors and Ergonomics Society
- Vol. 66 (3) , 744-769
Mobile Health Application for Seizure Management: A Human-Systems Integration Approach
Objective: The study aims to develop a mHealth application for seizure management based on the human system integration (HSI) approach. Background: Unmet healthcare needs among people with epilepsy continue to exist despite the advancement in healthcare technology. Current seizure management methods are found to be ineffective. Therefore, a more efficient strategy such as mHealth technology is necessary to aid seizure management. Method: The needs identification phase involved identifying the user requirements by interviewing 10 stakeholders and conducting thematic analysis and needs interpretation technique. In the solution identification phase, the system requirements were derived using various human-centered design and systems engineering approaches and were evaluated through quality function deployment to determine design targets. For the design and evaluation phase, the design targets were reflected in the app through the iterative prototyping process, and the interface and functional design were evaluated by seven human factors and ergonomics experts and four stakeholders, respectively. Results: Three primary needs and ten user requirements were derived from the needs identification phase. Ten out of fifteen system requirements were selected as design targets to be included in the final prototype. Results of the evaluation showed that the interface design of the proposed app showed superior usability compared to a competitor app and that the app functions were beneficial for the stakeholders. Conclusion: The mHealth app designed through the HSI framework showed good potential in addressing the main issues in seizure management. Application: The mHealth app design methodology based on the HSI approach can be applied to the design of small-scale systems in various domains.
- 25 March 2022
- Published by SAGE Publications in Human Factors: The Journal of the Human Factors and Ergonomics Society
- Vol. 66 (3) , 744-769
Mobile Health Application for Seizure Management: A Human-Systems Integration Approach
Objective: The study aims to develop a mHealth application for seizure management based on the human system integration (HSI) approach. Background: Unmet healthcare needs among people with epilepsy continue to exist despite the advancement in healthcare technology. Current seizure management methods are found to be ineffective. Therefore, a more efficient strategy such as mHealth technology is necessary to aid seizure management. Method: The needs identification phase involved identifying the user requirements by interviewing 10 stakeholders and conducting thematic analysis and needs interpretation technique. In the solution identification phase, the system requirements were derived using various human-centered design and systems engineering approaches and were evaluated through quality function deployment to determine design targets. For the design and evaluation phase, the design targets were reflected in the app through the iterative prototyping process, and the interface and functional design were evaluated by seven human factors and ergonomics experts and four stakeholders, respectively. Results: Three primary needs and ten user requirements were derived from the needs identification phase. Ten out of fifteen system requirements were selected as design targets to be included in the final prototype. Results of the evaluation showed that the interface design of the proposed app showed superior usability compared to a competitor app and that the app functions were beneficial for the stakeholders. Conclusion: The mHealth app designed through the HSI framework showed good potential in addressing the main issues in seizure management. Application: The mHealth app design methodology based on the HSI approach can be applied to the design of small-scale systems in various domains.