HWHanwei Wang

Hanwei Wang

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Hanwei Wang has a total of 24 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Plasmon-enhanced chiral absorption through electric dipole–electric quadrupole interaction

    by Hanwei Wang, Yang Zhao

    Enantioselective interactions of chiral molecules include distinct absorptions to opposite-handed circularly polarized light, known as chiral absorption. Traditionally, chiral absorption has been primarily attributed to electric dipole (ED) and magnetic dipole (MD) interaction with molecular chirality. However, this approach falls short for large molecules that support high-order multipolar components, such as electric quadrupole (EQ) moment. Here, we introduce a theoretical model to study the chiral absorption of large molecules in the presence of plasmonic nanostructures. This model considers both ED–MD interaction and ED–EQ interaction enhanced by a resonant structure. We numerically study such interactions of the chiral molecular solution in the vicinity of an achiral plasmonic nano-resonator. Our results show the distinct spectral information of the chiral medium on- and off-resonance of the resonator.


  • Open Access

    Visualizing ultrafast photothermal dynamics with decoupled optical force nanoscopy

    by Hanwei Wang, Sean M. Meyer, Catherine J. Murphy, Yun-Sheng Chen, Yang Zhao

    The photothermal effect in nanomaterials, resulting from resonant optical absorption, finds wide applications in biomedicine, cancer therapy, and microscopy. Despite its prevalence, the photothermal effect in light-absorbing nanoparticles has typically been assessed using bulk measurements, neglecting near-field effects. Beyond standard imaging and therapeutic uses, nanosecond-transient photothermal effects have been harnessed for bacterial inactivation, neural stimulation, drug delivery, and chemical synthesis. While scanning probe microscopy and electron microscopy offer single-particle imaging of photothermal fields, their slow speed limits observations to milliseconds or seconds, preventing nanoscale dynamic investigations. Here, we introduce decoupled optical force nanoscopy (Dofn), enabling nanometer-scale mapping of photothermal forces by exploiting unique phase responses to temporal modulation. We employ the photothermal effect’s back-action to distinguish various time frames within a modulation period. This allows us to capture the dynamic photothermal process of a single gold nanorod in the nanosecond range, providing insights into non-stationary thermal diffusion at the nanoscale.


  • Open Access

    A wearable metasurface for high efficiency, free-positioning omnidirectional wireless power transfer

    by Hanwei Wang, Yun-Sheng Chen, Yang Zhao

    We introduce a design principle of metasurfaces that can form any desired distribution of magnetic field for high-efficiency wireless power transfer centered at 200 kHz, which can be used to efficiently charge implanted medical devices. This metasurface can improve the power transfer efficiency for both single-user and multi-user cases by over tenfold compared to those without the metasurface. Our design enables a robust field distribution to the positions of the transmitting and receiving coils, as well as the geometric distortions of the metasurface itself, demonstrating its feasibility as a wearable device. With our design, the field distribution and subsequent power division among the multiple users can be readily controlled from equal distribution to any selective user(s). When incorporating a three-dimensional unit cell of the metasurface, we theoretically demonstrate an omnidirectional control of the field orientation to achieve a high-efficiency wireless power transfer for multiple users.


  • Ultra-high-frequency radio-frequency acoustic molecular imaging with saline nanodroplets in living subjects

    by Yun-Sheng Chen, Yang Zhao, Corinne Beinat, Aimen Zlitni, En-Chi Hsu, Dong-Hua Chen, Friso Achterberg, Hanwei Wang, Tanya Stoyanova, Jennifer Dionne, et al.

    Molecular imaging is a crucial technique in clinical diagnostics but it relies on radioactive tracers or strong magnetic fields that are unsuitable for many patients, particularly infants and pregnant women. Ultra-high-frequency radio-frequency acoustic (UHF-RF-acoustic) imaging using non-ionizing RF pulses allows deep-tissue imaging with sub-millimetre spatial resolution. However, lack of biocompatible and targetable contrast agents has prevented the successful in vivo application of UHF-RF-acoustic imaging. Here we report our development of targetable nanodroplets for UHF-RF-acoustic molecular imaging of cancers. We synthesize all-liquid nanodroplets containing hypertonic saline that are stable for at least 2 weeks and can produce high-intensity UHF-RF-acoustic signals. Compared with concentration-matched iron oxide nanoparticles, our nanodroplets produce at least 1,600 times higher UHF-RF-acoustic signals at the same imaging depth. We demonstrate in vivo imaging using the targeted nanodroplets in a prostate cancer xenograft mouse model expressing gastrin release protein receptor (GRPR), and show that targeting specificity is increased by more than 2-fold compared with untargeted nanodroplets or prostate cancer cells not expressing this receptor.


  • Open Access

    A Comparative Study on Overall Efficiency of Two-Dimensional Wireless Power Transfer Systems Using Rotational and Directional Methods

    by Hanwei Wang, Cheng Zhang, Yun Yang, Hui Wen Rebecca Liang, Shu Yuen Ron Hui

    Two-dimensional (2-D) wireless power transfer (WPT) systems can be controlled by either the directional method or the rotational method. The rotational method refers to the use of omnidirectional transmitter generating rotational flux regardless of the load positions, while the directional method refers to the use of omnidirectional transmitter generating magnetic flux directly toward the power-consuming load directions. This article compares the overall efficiency of the two methods for 2-D WPT systems. Theoretical analysis reveals that the directional WPT can be more efficient than the rotational WPT with either single or multiple loads when the magnetic field vector is controlled within the feasible zones; and the efficiency difference between the two methods are more significant when the dimensions of the receiver coils are smaller. Both simulation and experimental results are consistent in validating the two discoveries. They indicate that the averaged efficiency of the directional method is at least 5% higher than that of the rotational one.


  • Robust 3-D Wireless Power Transfer System Based on Rotating Fields for Multi-User Charging

    by Nelson Xuntuo Wang, Han-Wei Wang, Jie Mei, Sajjad Mohammadi, Jinyeong Moon, Jeffrey H. Lang, James L. Kirtley

    A wireless power transfer systems for multi-user charging is proposed to demonstrate a robust quasi-uniform power efficiency in 3-D space. It employs a set of balanced magnetic coils excited with phase-shifted currents on the transmitting side to feature omnidirectionality. In this paper, two transmitter structures, 2-coil and 3-coil systems are discussed and compared. These systems produce a quasi-uniform magnetic field magnitude regardless of the location of the receiving coils provided that the coils point to the center of the transmitting system sphere at the same distance. A simulation platform is established for the proposed method. Experimental results at 2MHz substantiate uniform spatial efficiency, and bound the average error of analytical calculations within 10%. Furthermore, the proposed method with rotating fields based on phase-shifted currents shows that 3-coil system yields a higher and much more stable efficiency range, 6.8% improvement on average efficiency and 88.7% reduction on efficiency variance compared to the 2-coil system. However, 3-coil suffers considerable cost disadvantage.


  • Analysis and Performance Enhancement of Wireless Power Transfer Systems With Intended Metallic Objects

    by Hui Wen Rebecca Liang, Hanwei Wang, Chi-Kwan Lee, S. Y. Ron Hui

    While detection of foreign or unintended metallic objects is an important topic for wireless power transfer (WPT), operation of WPT systems with intended metallic objects is largely an unchartered territory. This paper presents a methodology for analyzing the effects of intended metallic object on a WPT system through the study of the magnetic field distribution and the use of a reduced-order equivalent model of the systems for comparing the WPT system with and without the metallic object. The methodology is applied to a metallic corona ring of low resistance used with a WPT system. The analysis quantifies how an intended metallic object could change the magnetic coupling between the transmitter and receiver coils, and alter the equivalent resonant tank parameters of the WPT system. Re-compensation of the resonant tank can only enhance the power transfer capability but not the energy efficiency. The theory and practical verification of a new performance-enhancement method based on a combination of (i) re-compensating the resonant tanks and (ii) maximizing the equivalent mutual inductance of the Tx and Rx coils is presented. Such methodology provides a general approach to analyze WPT systems with or without relay resonators in the presence of intended metallic objects.