DODenys Oliinyk

Denys Oliinyk

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Denys Oliinyk has a total of 34 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    In situ polymerized monolith tips for reproducible, format-flexible proteomic sample preparation applied to biofluids

    by Kathrin Korff, Lukas Henneberg, Denys Oliinyk, Nils Eikmeier, Anton M. Schuele, Tim Heymann, Alicia-Sophie Schebesta, Vincent Albrecht, Christoph J.O. Kaiser, Matthias Mann, et al.

    Sample preparation increasingly sets the throughput and reproducibility of mass spectrometry (MS)-based proteomics. StageTips (stop-and-go extraction tips) and variants thereof have long been common implements to purify samples, and we recently extended the concept to solid-phase extraction capture (SPEC) tips, in which the entire digestion takes place in sub-microliter volumes. Here we replace the hand-packed bed with a strong anion-exchange (SAX) monolith photopolymerized directly inside the pipette tip from a defined recipe (pSPEC). A liquid-handling robot casts 384 tunable tips in minutes, at low cost and in any format, adding negligibly to the workflow's variance. Across biofluids, pSPEC added ~20% more identifications than in-solution plasma and reached 3,500 protein groups from a single injection of healthy urine and 4,800 from saliva at 100 samples per day, depths usually requiring depletion or fractionation. The same light-cast chemistry should extend to single cells, affinity capture, and population-scale studies.

  • Open Access

    diaPASEF analysis for HLA-I peptides enables quantification of common cancer neoantigens

    by Denys Oliinyk, Hem Gurung, Zhenru Zhou, Kristin Leskoske, Christopher M. Rose, Susan Klaeger

    Human leukocyte antigen class I (HLA-I) molecules present short peptide sequences from endogenous or foreign proteins to cytotoxic T cells. The low abundance of HLA-I peptides poses significant technical challenges for their identification and accurate quantification. While mass spectrometry (MS) is currently a method of choice for direct system-wide identification of cellular immunopeptidome, there is still a need for enhanced sensitivity in detecting and quantifying tumor specific epitopes. As gas phase separation in data-dependent MS data acquisition (DDA) increased HLA-I peptide detection by up to 50%, here, we aimed to evaluate the performance of data-independent acquisition (DIA) in combination with ion mobility (diaPASEF) for high-sensitivity identification of HLA presented peptides. Our streamlined diaPASEF workflow enabled identification of 11,412 unique peptides from 12.5 million A375 cells and 3,426 8-11mers from as low as 500,000 cells with high reproducibility. By taking advantage of HLA binder-specific in-silico predicted spectral libraries, we were able to further increase the number of identified HLA-I peptides. We applied SILAC-DIA to a mixture of labeled HLA-I peptides, calculated heavy-to-light ratios for 7,742 peptides across 5 conditions and demonstrated that diaPASEF achieves high quantitative accuracy up to 4-fold dilution. Finally, we identified and quantified shared neoantigens in a monoallelic C1R cell line model. By spiking in heavy synthetic peptides, we verified the identification of the peptide sequences and calculated relative abundances for 13 neoantigens. Taken together, diaPASEF analysis workflows for HLA-I peptides can increase the peptidome coverage for lower sample amounts. The sensitivity and quantitative precision provided by DIA can enable the detection and quantification of less abundant peptide species such as neoantigens across samples from the same background.

  • Open Access

    EXCRETE enables deep proteomics of the microbial extracellular environment

    by David A. Russo, Denys Oliinyk, Georg Pohnert, Florian Meier, Julie A. Z. Zedler

    Extracellular proteins play a significant role in shaping microbial communities which, in turn, can impact ecosystem function, human health, and biotechnological processes. Yet, for many ubiquitous microbes, there is limited knowledge regarding the identity and function of secreted proteins. Here, we introduce EXCRETE (enhanced exoproteome characterization by mass spectrometry), a workflow that enables comprehensive description of microbial exoproteomes from minimal starting material. Using cyanobacteria as a case study, we benchmark EXCRETE and show a significant increase over current methods in the identification of extracellular proteins. Subsequently, we show that EXCRETE can be miniaturized and adapted to a 96-well high-throughput format. Application of EXCRETE to cyanobacteria from different habitats ( Synechocystis sp. PCC 6803, Synechococcus sp. PCC 11901, and Nostoc punctiforme PCC 73102), and in different cultivation conditions, identified up to 85% of all predicted secreted proteins. Finally, functional analysis reveals that cell envelope maintenance and nutrient acquisition are central functions of the cyanobacterial secretome. Collectively, these findings challenge the general belief that cyanobacteria lack secretory proteins and point to a functional conservation of the secretome across freshwater, marine, and terrestrial species.


  • Open Access

    Peptide collision cross sections of 22 post-translational modifications

    by Andreas Will, Denys Oliinyk, Christian Bleiholder, Florian Meier

    Recent advances have rekindled the interest in ion mobility as an additional dimension of separation in mass spectrometry (MS)-based proteomics. Ion mobility separates ions according to their size and shape in the gas phase. Here, we set out to investigate the effect of 22 different post-translational modifications (PTMs) on the collision cross section (CCS) of peptides. In total, we analyzed ~4300 pairs of matching modified and unmodified peptide ion species by trapped ion mobility spectrometry (TIMS). Linear alignment based on spike-in reference peptides resulted in highly reproducible CCS values with a median coefficient of variation of 0.26%. On a global level, we observed a redistribution in the m/z vs. ion mobility space for modified peptides upon changes in their charge state. Pairwise comparison between modified and unmodified peptides of the same charge state revealed median shifts in CCS between −1.4% (arginine citrullination) and +4.5% (O-GlcNAcylation). In general, increasing modified peptide masses were correlated with higher CCS values, in particular within homologous PTM series. However, investigating the ion populations in more detail, we found that the change in CCS can vary substantially for a given PTM and is partially correlated with the gas phase structure of its unmodified counterpart. In conclusion, our study shows PTM- and sequence-specific effects on the cross section of peptides, which could be further leveraged for proteome-wide PTM analysis. Graphical Abstract


  • Open Access

    Peptide collision cross sections of 22 post-translational modifications

    by Andreas Will, Denys Oliinyk, Florian Meier

    Recent advances have rekindled the interest in ion mobility spectrometry as an additional dimension of separation in mass spectrometry (MS)-based proteomics. It separates ions according to their size and shape in the gas phase. Here, we set out to investigate the effect of 22 different post-translational modifications (PTMs) on the collision cross section (CCS) of peptides. In total, we analyzed ∼4700 pairs of matching modified and unmodified peptide ions by trapped ion mobility spectrometry (TIMS). Linear alignment based on spike-in reference peptides resulted in highly reproducible CCS values with a median coefficient of variation of 0.3%. On a global level, we observed a redistribution in the m/z vs. ion mobility space for modified peptides upon changes in their charge state. Pairwise comparison between modified and unmodified peptides of the same charge state revealed median shifts in CCS between – 1.1% (lysine formylation) and +4.5% (O-GlcNAcylation). In general, increasing modified peptide masses were correlated with higher CCS values, in particular within homologous PTM series. However, investigating the ion populations in more detail, we found that the change in CCS can vary substantially for a given PTM depending on the gas phase structure of its unmodified counterpart. In conclusion, our study shows PTM- and sequence-specific effects on the cross section of peptides, which could be further leveraged for proteome-wide PTM analysis.

  • Open Access

    PD-1 expression on NK cells can be related to cytokine stimulation and tissue residency

    by Arnika K Wagner, Nadir Kadri, Chris Tibbitt, Koen van de Ven, Sunitha Bagawath-Singh, Denys Oliinyk, Eric LeGresly, Nicole Campbell, Stephanie Trittel, Peggy Riese, et al.

    Although PD-1 was shown to be a hallmark of T cells exhaustion, controversial studies have been reported on the role of PD-1 on NK cells. Here, we found by flow cytometry and single cell RNA sequencing analysis that PD-1 can be expressed on MHC class I-deficient tumor-infiltrating NK cells in vivo . We also demonstrate distinct alterations in the phenotype of PD-1 -deficient NK cells which in part could be attributed to a decrease in tumor-infiltrating NK cells in PD-1 -deficient mice. NK cells from PD-1 -deficient mice exhibited a more mature phenotype which might reduce their capacity to migrate and kill in vivo . Finally, our results demonstrate that PD-L1 molecules in membranes of PD-1 -deficient NK cells migrate faster than in NK cells from wildtype mice, suggesting that PD-1 and PD-L1 form cis interactions with each other on NK cells.