Hengli Cai
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Hengli Cai has a total of 16 co-authors. Here are the top co-authors by number of shared publications:
- Wei Wang
School of Civil Engineering, Xi’an University of Architecture and Technology, Xi’an, China
4 shared publications - Shujun Hu
School of Infrastructure Engineering, Nanchang University, Nanchang 330031, China
2 shared publications - Xingyou Yao
Jiangxi Province Key Laboratory of Hydraulic and Civil Engineering Infrastructure Security, Nanchang Institute of Technology, Nanchang, China
2 shared publications Boyuan Gao
School of Civil Engineering Xi'an University of Architecture and Technology Xi'an China
1 shared publicationCongyou Bai
School of Civil Engineering Xi'an University of Architecture and Technology Xi'an China
1 shared publicationHaiyang Bao
School of Civil Engineering Xi'an University of Architecture and Technology Xi'an China
1 shared publication
Latest Publications
- Open Access
Experimental Investigation of Tensile Behavior of One-Side-Bolted T-Stub Connections
In this paper, an innovative T-stub connection with square-neck one-side bolts (TS-SNUBC) is developed to improve the bearing capacity and construction reliability of the box column-H beam joint. Twelve T-stub specimens, considering variations in bolt type, flange thickness, and bolt hole orientation, were designed and tested under uniaxial tension. The failure modes, load–displacement responses, ultimate load-bearing capacities, and key quantitative mechanical indicators (initial stiffness, ductility index and cumulative energy dissipation) of the specimens were evaluated. The results indicate that all specimens failed due to the yielding of the thin flange. Specimens with conventional bolts demonstrated the highest load-bearing capacity, followed by those with TS-SNUBC and then slotted one-side bolts. Increasing the thin flange thickness significantly improved the ultimate bearing capacity of the TS-SNUBC specimens. Notably, TS-SNUBC specimens with thin flange thicknesses below 10 mm experienced tear-out failure. Furthermore, specimens with horizontally oriented bolt holes exhibited higher load-bearing capacity than those with vertically oriented holes. A thin flange thickness above 10 mm ensures high initial stiffness, and TF12H has a stiffness of 32.00 kN/mm. Ductility gradually reduces with the growth of thin flange thickness. Energy dissipation decreases sharply when the thin flange is thicker than 10 mm. The joint with 16 mm thick flange, 8 mm thin flange and horizontally arranged square-neck one-side bolts presents the best comprehensive performance. The proposed TS-SNUBC shows favorable bearing performance and initial stiffness, offering a promising solution for reliable and efficiently constructed connections between box columns and steel beams.
Open AccessExperimental Investigation of Tensile Behavior of One-Side-Bolted T-Stub Connections
In this paper, an innovative T-stub connection with square-neck one-side bolts (TS-SNUBC) is developed to improve the bearing capacity and construction reliability of the box column-H beam joint. Twelve T-stub specimens, considering variations in bolt type, flange thickness, and bolt hole orientation, were designed and tested under uniaxial tension. The failure modes, load–displacement responses, ultimate load-bearing capacities, and key quantitative mechanical indicators (initial stiffness, ductility index and cumulative energy dissipation) of the specimens were evaluated. The results indicate that all specimens failed due to the yielding of the thin flange. Specimens with conventional bolts demonstrated the highest load-bearing capacity, followed by those with TS-SNUBC and then slotted one-side bolts. Increasing the thin flange thickness significantly improved the ultimate bearing capacity of the TS-SNUBC specimens. Notably, TS-SNUBC specimens with thin flange thicknesses below 10 mm experienced tear-out failure. Furthermore, specimens with horizontally oriented bolt holes exhibited higher load-bearing capacity than those with vertically oriented holes. A thin flange thickness above 10 mm ensures high initial stiffness, and TF12H has a stiffness of 32.00 kN/mm. Ductility gradually reduces with the growth of thin flange thickness. Energy dissipation decreases sharply when the thin flange is thicker than 10 mm. The joint with 16 mm thick flange, 8 mm thin flange and horizontally arranged square-neck one-side bolts presents the best comprehensive performance. The proposed TS-SNUBC shows favorable bearing performance and initial stiffness, offering a promising solution for reliable and efficiently constructed connections between box columns and steel beams.
- 23 March 2026
- Published by Springer Nature in International Journal of Steel Structures
- Vol. 26 (2) , 255-266
Numerical Simulation of Partially-Encased Composite Columns Under Monotonic and Cyclic Loading
- 23 March 2026
- Published by Springer Nature in International Journal of Steel Structures
- Vol. 26 (2) , 255-266
Numerical Simulation of Partially-Encased Composite Columns Under Monotonic and Cyclic Loading
- 13 December 2023
- Published by Wiley in The Structural Design of Tall and Special Buildings
- Vol. 33 (4)
Experimental and numerical study on eccentric compression performance of partially encased composite columns with corrugated web
Summary: Partially encased composite (PEC) members are becoming increasingly popular because of their high strength and suitability for prefabrication and assembly. Corrugated steel plate has higher out‐of‐plane stiffness than flat steel plate. When it is combined with concrete, the bonding between corrugated steel plate and concrete is more obvious than that between flat steel plate and concrete. For this reason, a new type of corrugated web PEC column (CPEC column) was proposed in this paper, and its eccentric compression performance was studied by experiment and numerical method. Nine specimens were tested, of which two were subjected to axial compression and seven were subjected to eccentric compression. The key factors considered in the experiment were the loading direction, load eccentricity, link spacing, and width‐to‐thickness ratio of flange. A three‐dimensional finite element model of the CPEC columns was established and verified, and the influence of the wave angle of corrugated web on the behavior of CPEC columns under eccentric compression was investigated using a parametric study. Finally, the current design codes for estimating the interaction curve and bearing capacity of CPEC columns were assessed.
- 13 December 2023
- Published by Wiley in The Structural Design of Tall and Special Buildings
- Vol. 33 (4)
Experimental and numerical study on eccentric compression performance of partially encased composite columns with corrugated web
Summary: Partially encased composite (PEC) members are becoming increasingly popular because of their high strength and suitability for prefabrication and assembly. Corrugated steel plate has higher out‐of‐plane stiffness than flat steel plate. When it is combined with concrete, the bonding between corrugated steel plate and concrete is more obvious than that between flat steel plate and concrete. For this reason, a new type of corrugated web PEC column (CPEC column) was proposed in this paper, and its eccentric compression performance was studied by experiment and numerical method. Nine specimens were tested, of which two were subjected to axial compression and seven were subjected to eccentric compression. The key factors considered in the experiment were the loading direction, load eccentricity, link spacing, and width‐to‐thickness ratio of flange. A three‐dimensional finite element model of the CPEC columns was established and verified, and the influence of the wave angle of corrugated web on the behavior of CPEC columns under eccentric compression was investigated using a parametric study. Finally, the current design codes for estimating the interaction curve and bearing capacity of CPEC columns were assessed.
- 1 June 2021
- Published by Elsevier in Thin-Walled Structures
- Vol. 163
Experimental and numerical studies of an axial tension-compression corrugated steel plate damper
- 1 June 2021
- Published by Elsevier in Thin-Walled Structures
- Vol. 163
Experimental and numerical studies of an axial tension-compression corrugated steel plate damper