CPCarl Oskar Paulrud

Carl Oskar Paulrud

*This is an algorithmically generated author record based on publicly available information.

Carl Oskar Paulrud has a total of 20 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    An observational study investigating the association of teat condition with clinical mastitis risk

    by M. Wieland, C.O. Paulrud, K. Kakoulis, M.E. Spellman, H. Somula, A. Singh

    The objectives were to investigate the association between machine milking-induced teat tissue changes and the occurrence of clinical mastitis in Holstein dairy cows. We conducted 2 separate prospective cohort studies at 1 commercial dairy farm in New York State to study the association of machine milking-induced short-term changes (STC, trial 1) and machine milking-induced long-term changes (LTC, trial 2) with clinical mastitis occurrence. Each trial consisted of four 3-wk periods. On d 1 of each period, STC and LTC were assessed through visual inspection and manual palpation. Short-term teat tissue changes were assessed based on teat discoloration, the condition of the teat base, and the consistency of the teat end and categorized into a binary variable (STC present or absent). Long-term teat tissue changes were categorized into 4 groups as follows: no callosity present (score 1), callosity ring present with no or only mild roughness (score 2); callosity ring and roughness present with keratin fronds extending 1 to 3 mm from the teat orifice (score 3); and callosity ring present with excessive keratin fronds extending ≥4 mm from the teat orifice (score 4). Data on clinical mastitis occurrence was extracted from the herd management software. We used the first clinical mastitis event of a quarter for each 3-wk trial period and applied a 14-d gap to define a new mastitis case within a quarter between 2 trial periods. In trial 1, STC was documented in 6,110 of 66,702 cases (9.2%) over the four 3-wk periods, The frequency distribution of LTC in trial 2 was as follows: score 1 in 7,348 of 61,624 cases (11.9%), score 2 in 48,553 cases (78.8%), score 3 in 5,514 cases (8.9%), and score 4 in 209 cases (0.3%). We documented 944/66,702 (1.4%) clinical mastitis cases at the quarter level during trial 1 and 866/61,624 (1.4%) cases during trial 2. Generalized linear mixed models with a logit link and a binomial distribution were used to test if machine milking-induced teat tissue changes were associated with clinical mastitis occurrence. In trial 1, we analyzed 66,702 quarter-level observations from 5,094 cows. We found no significant association between STC and clinical mastitis occurrence. Compared with a quarter with a teat without STC, the odds (95% CI) of clinical mastitis were 1.22 (0.95-1.59). In trial 2, we used 61,624 quarter-level observations from 4,998 cows. We found no significant association between LTC and clinical mastitis occurrence. Compared with a quarter with a teat with a smooth end (score 1), the odds of a clinical mastitis case were 1.02 (0.77-1.36) for score 2, 1.19 (0.84-1.69) for score 3, and 2.14 (0.80-5.71) for score 4. We concluded that in the study cohort presented here, machine milking-induced teat tissue changes were not associated with the occurrence of clinical mastitis.


  • Open Access

    Effects of flow-responsive milking on milking performance of an automatic milking installation

    by D.J. Reinemann, C.O. Paulrud, Johan ter Weele

    Summary: This paper presents the results of a field test of a vacuum-control system, flow-responsive milking (FRM), applied to the DeLaval VMS automatic milking system that maintains teat-end vacuum during the milking process with the aim of reducing milking duration. This FRM system was implemented on an automatic milking installation and resulted in increased milk flow rates at the udder and quarter level, with indications of more complete milking, and demonstrated the potential to improve the capacity of automatic milking installations.


  • Open Access

    Invited review: Contribution of milk harvesting research to optimal interaction between biology and milking technology

    by J. Upton, R.M. Bruckmaier, G.A. Mein, D.J. Reinemann, M. Wieland, C.O. Paulrud, J. Baines, I. Ohnstad, M D Rasmussen

    The broad focus of this review is on milk harvesting in machine-milked herds. With particular emphasis on: (1) milk secretion and storage dynamics in the udder, (2) milk ejection, (3) milk flow profiles and their effect on milking efficiency, (5) immunological activity and milking efficiency, (5) milking machine aspects of milk removal, and (6) the future potential of milking technology. Machine milking has evolved from its early mechanical beginnings into a technologically advanced, data-driven process that must balance speed, chosen completeness, and gentleness on teat tissue to support efficient milk removal and optimal udder health. This review summarizes the current understanding of milk harvesting from a physiological, mechanical, and managerial perspective and outlines the key factors shaping its future development. Fundamentally, milk harvesting is built upon a biological sequence involving milk synthesis, ejection, and removal. Milk synthesis occurs at the alveolar level and is influenced by local quarter-specific physiology. Milk ejection is driven by the oxytocin-mediated contraction of myoepithelial cells, a process sensitive to the degree of udder filling, familiarity with the milking environment, and cow-operator interactions. Milk flow profiles, shaped by these biological processes, provide crucial insights into milking efficiency and udder health outcomes. At the machine level, key variables include milking vacuum, pulsation characteristics, liner properties, and teatcup removal strategies. Optimal settings for each of these parameters depend on dynamic interactions with cow physiology and milking stage. Recent research highlights the need to consider these factors not in isolation but as part of an integrated milking system, where vacuum, pulsation, liner design, and timing of teatcup removal interact to affect milking speed, teat condition, and udder health. Automation of milking systems and indeed automated milking systems have driven a shift toward individualized milking at the quarter level, enabling more precise control of extraction timing and flow rate. The integration of real-time sensor data, machine learning, and adaptive milking parameters represents a major step forward in the optimization of milking systems. In the near future, distinctions between automated milking systems and conventional systems will become increasingly blurred, as both adopt automation and intelligent controls tailored to individual cows and quarters. This review also explores the role of immunological activity in shaping milking efficiency. Elevated SCC has been associated with altered milk flow curves and decreased productivity. There is emerging evidence suggesting that modern selection and management strategies may reduce the historical link between fast milking and mastitis risk. This relationship remains complex and context dependent. The detection and management of abnormal milk (supported by more advanced inline sensor systems) is expected to become a cornerstone of future milking technology. Looking forward, the drivers of change in milk harvesting will include labor availability, economic pressures, environmental concerns, animal health, and consumer expectations. A new era of biologically aware, data-informed, and precision-engineered milking systems is emerging. These systems will support the gentle, efficient removal of milk to a user-defined end point, tailored to each animal and each milking event.


  • Open Access

    Increased pulsation ratio in rear quarters reduces machine-on time and milking on empty teats

    by Patricia Fürst, Moritz Affentranger, Carl Oskar Paulrud, Rupert M. Bruckmaier

    Dairy cows usually store more milk in rear than in front quarters. At conventional machine milking this leads to an earlier cessation of milk flow in front than in rear quarters and hence unavoidable milking on empty front teats. We tested the hypothesis that an increased pulsation ratio in rear quarters reduces both milking on empty front teats and machine-on time. We have also tested if the different amplitude of cyclic vacuum fluctuations during milking with simultaneous vs. alternate pulsation within front and rear quarters, respectively, impacts milking characteristics. Ten Holstein dairy cows were milked twice daily at 14-h and 10-h milking intervals. Pulsation ratio in front quarters was 65:35, but was either set at 65:35, 70:30, 75:25 or 80:20 in rear quarters. Whole udder milk flow, claw vacuum, and mouthpiece chamber vacuum of all 4 quarters were recorded during milking. Teat tissue thickness of all 4 teats was measured with a cutimeter at 5 and 30 min after cluster detachment. Total milk yield did not differ among treatments, indicating complete udder emptying. The time of quarter milk flow (tQMF) of front quarters did not differ among treatments but decreased with increasing pulsation ratio in rear quarters. In addition, the faster milking of rear quarters at higher pulsation ratio caused higher peak and average milk flow rates, a shorter duration of milk flow decline, and a reduced machine-on time. The increased milk flow at a higher pulsation ratio did not cause a significant reduction of the claw vacuum at the used sample size. Teat tissue thickness did not significantly differ among treatments, likely because milking on empty teats did almost not occur in the rear quarters, and treatment settings did not differ in front quarters. Simultaneous pulsation caused higher amplitudes of cyclic vacuum fluctuation than alternate pulsation. However, milking characteristics did not differ between simultaneous and alternate pulsation. In conclusion, an increased pulsation ratio in rear quarters reduces machine-on time, increases milking performance, and reduces the time of milking on empty teats in front quarters, without an increased impact on teat tissue thickness.


  • Open Access

    Effects of flow-responsive vacuum and pulsation with early attachment of the milking unit on teat tissue condition and milking performance in Holstein dairy cows

    by A. Singh, M.E. Spellman, H. Somula, K. Kakoulis, C.O. Paulrud, M. Wieland

    The objectives of this study were to assess the effect of flow-responsive vacuum and pulsation, in conjunction with the early attachment of the milking unit (TRT), on teat tissue conditions and milking characteristics in dairy cows. In a switch-back trial, 5,235 Holstein cows milked 3 times daily in a rotary parlor were assigned to the TRT or control (CON) group. The trial lasted 84 d and was comprised of 4 alternating 3-week periods of TRT and CON. For both groups, premilking udder preparation consisted of teat brushing, forestripping and predipping, and wiping of teats, resulting in a stimulation time of 4 s. In the TRT group, the preparation lag time was 58 s, and in the CON group, it was 91 s for early- and mid-lactation cows and 105 s for late-lactation animals. Upon milking unit attachment, the TRT cows were milked at a lower vacuum (37.6 kPa) and pulsation (50 cycles/min, pulsation ratio of 30:70). The vacuum and pulsation settings were changed to milking mode when the milk flow reached 0.5 kg/min (pulsation switch-point) and 1.6 kg/min (vacuum switch-point). For milking mode, the vacuum setting was 47.7 kPa, and the pulsation rate was 60 cycles/min at a ratio of 65:35. The CON cows were milked with a flow-responsive vacuum, using the same vacuum settings as the TRT group. We assessed machine milking-induced short-term teat tissue changes and teat-end hyperkeratosis by palpation and visual inspection postmilking. Electronic on-farm milk meters were used to assess milking characteristics. Generalized linear mixed models were used to analyze the effect of treatment on the outcome variables. Compared with cows in group CON, the odds ratios (95% confidence interval; 95% CI) of short-term teat-tissue changes in early-, mid-, and late lactation cows in group TRT were 0.62 (0.52-0.76), 0.61 (0.48-0.77), and 0.93 (0.76-1.14), respectively. The least squares means [LSM, (95% CI)] for milking unit-on time in early-, mid-, and late lactation animals, respectively, were 251 (248-253), 236 (234-238), and 220 (218-222) s for group TRT and 247 (245-249), 232 (230-234), and 214 (213-216) s for the CON group. The LSM (95% CI) of peak milk flow rate in early-, mid-, and late lactation animals, respectively, were 5.75 (5.68-5.82), 5.77 (5.70-5.84), and 5.54 (5.48-5.59) kg/min for the TRT cows and 5.65 (5.58-5.72), 5.74 (5.68-5.81), and 5.45 (5.40-5.51) kg/min for the CON cows. The odds ratios (95% CI) of forced take-off in group TRT for early-, mid-, and late lactation cows, respectively, were 0.39 (0.37-0.41), 0.32 (0.30-0.34), and 0.47 (0.44-0.52) compared with their respective CON groups. In this study, cows that were milked using flow-responsive vacuum and pulsation with early attachment of the milking unit had lower odds of short-term teat tissue changes and forced take-off, as well as a higher peak milk flow rate. Our data suggest that the application of flow-responsive vacuum and pulsation facilitates early attachment of the milking unit, improves teat tissue condition, and has the potential to improve parlor efficiency.


  • Open Access

    The mouthpiece chamber vacuum pattern indicates the cessation of milk flow and suits as an indicator to reduce teat end vacuum at a quarter level

    by Kathrin Schlapbach, Momena Khatun, Carl Oskar Paulrud, Rupert M. Bruckmaier

    We investigated the suitability of the quarter mouthpiece chamber vacuum (MPCV) as an indicator for cessation of quarter milk flow to potentially adjust the teat end vacuum at a quarter level. We tested the hypothesis that a MPCV increase is a clear indicator of quarter milk flow cessation. In addition, we tested if a quarter -individual vacuum reduction at MPCV increase reduces the mechanical effect on the teat. Ten dairy cows were milked twice daily with a quarterspecific vacuum supply with continuously high (51 kPa; TRT51) or low vacuum setting (41 kPa; TRT41), or high vacuum setting combined with a quarter -specific vacuum reduction by 10 kPa immediately after the quarter -specific MPCV increase (TRT51/41). Whole udder milk flow was continuously recorded. Each treatment was repeated at 4 subsequent milkings. The high vacuum settings (TRT51; TRT51/41) reached higher values in peak flow rate and average milk flow and consequently shorter machine -on time. The time from start of milking until the steep increase of the MPCV was shorter in front than rear quarters, and hence the time from start of MPCV increase until end of milking was longer in front than rear teats. Teat condition of the right front teats was measured for teat wall diameter by ultrasound and teat tissue thickness by cutimeter at 5 and 20 min after each experimental milking. The teat measurements were taken at the teat tip (distal barrel) and 2 cm above the teat tip (proximal barrel). The proximal teat wall diameter tended to be higher in TRT51 than in TRT41, both 5 and 20 min after milking. The distal teat wall diameter at 5 min was greater in TRT51 than in TRT41. In TRT51/41 the teat wall diameter at both locations was intermediate, not significantly different from either TRT51 or TRT41. The distal teat tissue thickness was greater in TRT51 than in TRT41, and tended to be greater in TRT51/41 than in TRT41 at 5 min. The proximal teat tissue thickness at 5 min was higher in TRT51 and TRT51/41 than in TRT41. The teat tissue thickness decreased from 5 to 20 min only in the proximal barrel. The quarter -individual MPCV increase appears to be a suitable indicator of the cessation of milk flow. The lack of a significant reduction of mechanical effect on the teat by a reduced vacuum of 41 kPa indicates that the vacuum level chosen may be still too high under conditions of a separate vacuum supply for each quarter, which prevents a vacuum drop caused by the whole udder milk flow.


  • Open Access

    Effects of flow-controlled vacuum on milking performance and teat condition in a rotary milking parlor

    by D.J. Reinemann, B.H.P. van Den Borne, H. Hogeveen, M. Wiedemann, C.O. Paulrud

    The objective of this study was to compare a vacuum control system that increases milking system vacuum during the peak flow period of milking to conventional constant vacuum control technology regarding its effect on milk flowrate and milking duration. Further objectives were to study the effects of flow-controlled vacuum on milking parlor performance. An observational study was conducted on a commercial dairy farm milking from 848 to 896 cows per day over the study period using a 60-stall rotary milking parlor. The flow-controlled vacuum control system was applied for 3 wk. Milking performance and teat condition were compared with 3-wk periods prior and subsequent to the test period using conventional vacuum control. Statistical analysis was performed assuming a cross-sectional study design during each period. Flow-controlled vacuum increased peak milk flowrate by 12% and increased average milk flowrate by 4%. The decrease in individual cow milking duration was proportional to milk yield per milking. Postmilking teat condition was good during the entire study period. The occurrence of rough teat ends was slightly reduced during the flow-controlled vacuum period with no meaningful difference in the occurrence of teats with blue color, palpable rings, or petechia. The combination of reduced vacuum during the low flow period of milking and the decrease in milking duration are likely factors that are protective of teat tissues. Bioeconomic modeling of the use of flow-controlled vacuum on the performance of rotary milking parlors, using the data that were collected during the study, showed that the reduction in milking duration of individual cows allows a higher rotary parlor speed. Modeled parlor throughput increased by 5.0% to 419 cows/h, 6.8% to 407 cows/h, and 4.2% to 326 cows/h when 80%, 95%, and 99% of the cows were finished milking at the end of the rotation for a 60-stall parlor. Model results showed that increased parlor throughput resulted in increased labor efficiency, reduced labor costs for milking, and a positive benefit-cost ratio on the investment for all but the smallest herd and parlor sizes considered.