Shota Hoshika
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Shota Hoshika has a total of 49 co-authors. Here are the top co-authors by number of shared publications:
- Norimasa Takahashi
Sports Medicine and Joint Center, Funabashi Orthopaedic Hospital, Funabashi, Chiba, Japan
13 shared publications - Hiroyuki Sugaya
Tokyo Sports & Orthopaedic Clinic, Tokyo, Japan
11 shared publications - Keisuke Matsuki
Sports Medicine and Joint Center, Funabashi Orthopaedic Hospital, Funabashi, Chiba, Japan
11 shared publications - Itaru Kawashima
Department of Orthopaedic Surgery Yachiyo Hospital Anjo Aichi Japan
5 shared publications Keisuke Matsuki
Shoulder & Elbow Service, Funabashi Orthopaedic Sports Medicine & Joint Center, Funabashi, Chiba, Japan
4 shared publications- Akimoto Nimura
Department of Functional Joint Anatomy, Biomedical Engineering Laboratory, Institute of Industry Incubation, Institute of Science Tokyo, Tokyo, Japan
3 shared publications
Latest Publications
- 30 October 2026
- Published by Wiley in Arthroscopy
Teres Minor Fatty Degeneration Progression by Magnetic Resonance Imaging Analysis Is Associated With Graft Failure After Arthroscopic Superior Capsule Reconstruction
Purpose: To investigate risk factors, including rotator cuff fatty degeneration, for postoperative graft failure within 1 year after arthroscopic superior capsule reconstruction using a fascia lata autograft in shoulders with an intact or reparable subscapularis tendon. Methods: Patients who underwent arthroscopic superior capsule reconstruction for massive or irreparable rotator cuff tears between June 2016 and December 2022, with a minimum 12‐month follow‐up, were retrospectively reviewed. Radiological evaluations included measurement of acromiohumeral distance and fatty degeneration of the rotator cuff muscles using the Goutallier classification. The Goutallier grades were classified into none‐to‐mild (grades 0‐1) and moderate‐to‐severe fatty infiltration (grades 2‐4). Graft integrity was assessed using the Sugaya classification on postoperative magnetic resonance imaging obtained 1 year after surgery, and patients were categorized into a nonfailure group (Group I) and graft failure group (Group GF). Univariate and multivariate logistic regression analyses were performed to identify the significant risk factors for graft failure. Results: Eighty‐seven shoulders were included: 70 in Group I and 17 in Group GF. The mean radiological follow‐up (range) was 22.2 (12‐72) in Group I versus 25.5 (12‐65) months in Group GF ( P = .163). Similarly, patient‐reported outcome measure follow‐up was 22.3 (12‐48) versus 22.6 (12‐47) months ( P = .839). Group GF showed significantly greater fatty degeneration of the teres minor and a higher prevalence of moderate‐to‐severe fatty infiltration (58.8% vs 25.7%, P = .012). Multivariate logistic regression identified teres minor fatty degeneration and the preoperative acromiohumeral distance as risk factors for graft failure. Clinical outcomes improved significantly in both groups, although the magnitude was lower in Group GF. Conclusions: This study showed that moderate‐to‐severe fatty degeneration of the teres minor and a smaller preoperative acromiohumeral distance are significant risk factors for graft failure after arthroscopic superior capsule reconstruction in shoulders with an intact or reparable subscapularis tendon. Level of Evidence: Level III, retrospective cohort study.
- 30 October 2026
- Published by Wiley in Arthroscopy
Teres Minor Fatty Degeneration Progression by Magnetic Resonance Imaging Analysis Is Associated With Graft Failure After Arthroscopic Superior Capsule Reconstruction
Purpose: To investigate risk factors, including rotator cuff fatty degeneration, for postoperative graft failure within 1 year after arthroscopic superior capsule reconstruction using a fascia lata autograft in shoulders with an intact or reparable subscapularis tendon. Methods: Patients who underwent arthroscopic superior capsule reconstruction for massive or irreparable rotator cuff tears between June 2016 and December 2022, with a minimum 12‐month follow‐up, were retrospectively reviewed. Radiological evaluations included measurement of acromiohumeral distance and fatty degeneration of the rotator cuff muscles using the Goutallier classification. The Goutallier grades were classified into none‐to‐mild (grades 0‐1) and moderate‐to‐severe fatty infiltration (grades 2‐4). Graft integrity was assessed using the Sugaya classification on postoperative magnetic resonance imaging obtained 1 year after surgery, and patients were categorized into a nonfailure group (Group I) and graft failure group (Group GF). Univariate and multivariate logistic regression analyses were performed to identify the significant risk factors for graft failure. Results: Eighty‐seven shoulders were included: 70 in Group I and 17 in Group GF. The mean radiological follow‐up (range) was 22.2 (12‐72) in Group I versus 25.5 (12‐65) months in Group GF ( P = .163). Similarly, patient‐reported outcome measure follow‐up was 22.3 (12‐48) versus 22.6 (12‐47) months ( P = .839). Group GF showed significantly greater fatty degeneration of the teres minor and a higher prevalence of moderate‐to‐severe fatty infiltration (58.8% vs 25.7%, P = .012). Multivariate logistic regression identified teres minor fatty degeneration and the preoperative acromiohumeral distance as risk factors for graft failure. Clinical outcomes improved significantly in both groups, although the magnitude was lower in Group GF. Conclusions: This study showed that moderate‐to‐severe fatty degeneration of the teres minor and a smaller preoperative acromiohumeral distance are significant risk factors for graft failure after arthroscopic superior capsule reconstruction in shoulders with an intact or reparable subscapularis tendon. Level of Evidence: Level III, retrospective cohort study.
- Open Access
- 4 September 2026
- Published by Elsevier in JSES International
- Vol. 10 (6)
The usefulness of a newly developed ultrasonographic measurement method for predicting post-operative stiffness after arthroscopic rotator cuff repair
- 4 September 2026
- Published by Elsevier in JSES International
- Vol. 10 (6)
Open AccessThe usefulness of a newly developed ultrasonographic measurement method for predicting post-operative stiffness after arthroscopic rotator cuff repair
- 29 July 2026
- Published by Wiley in Arthroscopy
- Vol. 42 (11) , 2408-2416
Surgical Time Is More Predictive of Suture Contamination During Arthroscopic Rotator Cuff Repair Compared With Skin‐Preparation Method: A Prospective Randomized Study on Male Patients
Purpose: To compare 3 antiseptics and to identify factors associated with suture contamination during arthroscopic rotator cuff repair. Methods: One hundred fifty male patients scheduled for rotator cuff repair between July 2021 and October 2022 were enrolled. Patients were randomly assigned to 1 of 3 antiseptics groups: povidone‐iodine (P), alcohol‐containing povidone‐iodine (AP), and olanexidine gluconate (O). To minimize variability in surgical duration, surgeons were categorized into 3 groups (A, shortest; B, intermediate; C, longest) based on their preliminary average surgical time, and 1 of 3 antiseptics was randomly assigned to each group. Sutures cut after the last medial knot tying were cultured for a maximum of 3 weeks. The positive rates of Cutibacterium acnes and miscellaneous bacteria were compared between antiseptics and surgeon groups. Repair integrity was evaluated via postoperative magnetic resonance imaging, and its relation with contamination was assessed. Results: C. acnes was detected in 92 shoulders (61%) and miscellaneous bacteria in 34 shoulders (23%), with coagulase‐negative Staphylococcus predominating. There were no significant differences in the C. acnes ‐positive rates between the antiseptics groups. The contamination rate for any bacteria was significantly lower in AP than in O. Logistic regression analysis showed that O had a higher risk of any bacterial contamination than AP (odds ratio, 3.82; P = .013). Shorter surgical and suture exposure times were associated with lower contamination rates. No relation was found between contamination and retear. Conclusions: C. acnes was the most commonly detected bacterium in suture contamination during arthroscopic rotator cuff repairs. There was no difference in the efficacy of the 3 disinfectants in preventing C. acnes contamination; however, the overall bacterial contamination rate was significantly higher in olanexidine compared with alcohol‐containing povidone‐iodine. Shorter surgical and suture exposure times were associated with a lower incidence of suture contamination. Level of Evidence: Level I, prospective randomized study.
- 29 July 2026
- Published by Wiley in Arthroscopy
- Vol. 42 (11) , 2408-2416
Surgical Time Is More Predictive of Suture Contamination During Arthroscopic Rotator Cuff Repair Compared With Skin‐Preparation Method: A Prospective Randomized Study on Male Patients
Purpose: To compare 3 antiseptics and to identify factors associated with suture contamination during arthroscopic rotator cuff repair. Methods: One hundred fifty male patients scheduled for rotator cuff repair between July 2021 and October 2022 were enrolled. Patients were randomly assigned to 1 of 3 antiseptics groups: povidone‐iodine (P), alcohol‐containing povidone‐iodine (AP), and olanexidine gluconate (O). To minimize variability in surgical duration, surgeons were categorized into 3 groups (A, shortest; B, intermediate; C, longest) based on their preliminary average surgical time, and 1 of 3 antiseptics was randomly assigned to each group. Sutures cut after the last medial knot tying were cultured for a maximum of 3 weeks. The positive rates of Cutibacterium acnes and miscellaneous bacteria were compared between antiseptics and surgeon groups. Repair integrity was evaluated via postoperative magnetic resonance imaging, and its relation with contamination was assessed. Results: C. acnes was detected in 92 shoulders (61%) and miscellaneous bacteria in 34 shoulders (23%), with coagulase‐negative Staphylococcus predominating. There were no significant differences in the C. acnes ‐positive rates between the antiseptics groups. The contamination rate for any bacteria was significantly lower in AP than in O. Logistic regression analysis showed that O had a higher risk of any bacterial contamination than AP (odds ratio, 3.82; P = .013). Shorter surgical and suture exposure times were associated with lower contamination rates. No relation was found between contamination and retear. Conclusions: C. acnes was the most commonly detected bacterium in suture contamination during arthroscopic rotator cuff repairs. There was no difference in the efficacy of the 3 disinfectants in preventing C. acnes contamination; however, the overall bacterial contamination rate was significantly higher in olanexidine compared with alcohol‐containing povidone‐iodine. Shorter surgical and suture exposure times were associated with a lower incidence of suture contamination. Level of Evidence: Level I, prospective randomized study.
- Open Access
- 12 January 2026
- Published by Elsevier in JSES International
- Vol. 10 (2) , 101626
Prophylactic acromion pin fixation reduces catastrophic failure in weakened acromion biomechanical model of reverse shoulder arthroplasty
- 12 January 2026
- Published by Elsevier in JSES International
- Vol. 10 (2) , 101626
Open AccessProphylactic acromion pin fixation reduces catastrophic failure in weakened acromion biomechanical model of reverse shoulder arthroplasty
- Open Access
- 29 December 2025
- Published by Elsevier in JSES Reviews, Reports, and Techniques
- Vol. 6 (2) , 100649
Return to play and recovery metrics after arthroscopic Bankart repair with augmentations in rugby players
- 29 December 2025
- Published by Elsevier in JSES Reviews, Reports, and Techniques
- Vol. 6 (2) , 100649
Open AccessReturn to play and recovery metrics after arthroscopic Bankart repair with augmentations in rugby players
- Open Access
- 15 October 2025
- Published by Elsevier in JSES International
- Vol. 10 (1) , 101390
Effectiveness of focused extracorporeal shock wave therapy for suspected ulnar collateral ligament–related symptoms in competitive baseball pitchers
- 15 October 2025
- Published by Elsevier in JSES International
- Vol. 10 (1) , 101390
Open AccessEffectiveness of focused extracorporeal shock wave therapy for suspected ulnar collateral ligament–related symptoms in competitive baseball pitchers
- Open Access
- 28 May 2025
- Published by Elsevier in JSES International
- Vol. 9 (5) , 1511-1516
Prolonged early postoperative adduction restriction is significantly associated with shoulder stiffness 1 year after arthroscopic rotator cuff repair
- 28 May 2025
- Published by Elsevier in JSES International
- Vol. 9 (5) , 1511-1516
Open AccessProlonged early postoperative adduction restriction is significantly associated with shoulder stiffness 1 year after arthroscopic rotator cuff repair
- Open Access
- 28 May 2025
- Published by Elsevier in JSES International
- Vol. 9 (5) , 1504-1510
Superior capsule reconstruction stabilizes the humeral head during scaption: in vivo 3-dimensional kinematic analysis using model–image registration
- 28 May 2025
- Published by Elsevier in JSES International
- Vol. 9 (5) , 1504-1510
Open AccessSuperior capsule reconstruction stabilizes the humeral head during scaption: in vivo 3-dimensional kinematic analysis using model–image registration
- 30 January 2025
- Published by Elsevier in Journal of Shoulder and Elbow Surgery
- Vol. 34 (9) , e740-e749
Lateralized reverse shoulder arthroplasty shows similar scaption kinematics but greater scapular neck-insert distance during external rotation compared to Grammont prosthesis
- 30 January 2025
- Published by Elsevier in Journal of Shoulder and Elbow Surgery
- Vol. 34 (9) , e740-e749
Lateralized reverse shoulder arthroplasty shows similar scaption kinematics but greater scapular neck-insert distance during external rotation compared to Grammont prosthesis
- Open Access
- 27 January 2025
- Published by Elsevier in JSES International
- Vol. 9 (3) , 619-624
Revision arthroscopic soft-tissue stabilization for failed coracoid transfer yields low recurrence and high sports return rates
- 27 January 2025
- Published by Elsevier in JSES International
- Vol. 9 (3) , 619-624
Open AccessRevision arthroscopic soft-tissue stabilization for failed coracoid transfer yields low recurrence and high sports return rates