Ronald Owen Nelson
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Ronald Owen Nelson has a total of 94 co-authors. Here are the top co-authors by number of shared publications:
- Matthew Devlin
Los Alamos National Laboratory
8 shared publications N. Fotiades
Los Alamos National Laboratory, PO Box 1663, Los Alamos, NM 87545, USA
5 shared publications- Toshihiko Kawano
Los Alamos National Laboratory
4 shared publications - Robert C. Haight
University of North Texas System College of Pharmacy, 3500 Camp Bowie Blvd, Fort Worth, Texas 76107, United States of America
3 shared publications - Stephen Arthur Wender
Los Alamos National Laboratory, Los Alamos, NM, USA
3 shared publications A. Chyzh
Lawrence Livermore National Laboratory, PO Box 808, Livermore, CA 94551, USA
2 shared publications
Latest Publications
- 30 October 2026
- Published by American Physical Society (APS) in Physical Review C
- Vol. 114 (4) , 044627
Prompt γ -ray production cross sections for neutron-induced reactions on Kr 86
Prompt $\ensuremath{\gamma}$-ray production cross sections are important for nuclear reaction and structure calculations and in several applications. In particular, $\ensuremath{\gamma}$-ray production data and calculations are used in material assay and neutron diagnostics. $^{86}\mathrm{Kr}$ is a common, stable fission fragment, and as such can be used to test nuclear reaction models at the edge of stability, in order to improve calculations extending into unstable fission fragments in the region. Partial prompt $\ensuremath{\gamma}$-ray cross sections were measured, produced in neutron-induced reactions for neutron energies $11\phantom{\rule{0.16em}{0ex}}\mathrm{MeV}<{E}_{n}<80\phantom{\rule{0.16em}{0ex}}\mathrm{MeV}$ on $^{86}\mathrm{Kr}$: three $\ensuremath{\gamma}$ rays of $^{85}\mathrm{Kr}$ and one $\ensuremath{\gamma}$ ray each in $^{82,83,84}\mathrm{Kr}$ and $^{83,85}\mathrm{Br}$. A large part of the total cross section for the $^{86}\mathrm{Kr}(n,3n)^{84}\mathrm{Kr}$ reaction is experimentally observed. The results are compared with predictions from calculations using the ${\mathrm{CoH}}_{3}$ reaction code and are used to check on the consistency of the parameters in the calculations.- 30 October 2026
- Published by American Physical Society (APS) in Physical Review C
- Vol. 114 (4) , 044627
Prompt γ -ray production cross sections for neutron-induced reactions on Kr 86
Prompt $\ensuremath{\gamma}$-ray production cross sections are important for nuclear reaction and structure calculations and in several applications. In particular, $\ensuremath{\gamma}$-ray production data and calculations are used in material assay and neutron diagnostics. $^{86}\mathrm{Kr}$ is a common, stable fission fragment, and as such can be used to test nuclear reaction models at the edge of stability, in order to improve calculations extending into unstable fission fragments in the region. Partial prompt $\ensuremath{\gamma}$-ray cross sections were measured, produced in neutron-induced reactions for neutron energies $11\phantom{\rule{0.16em}{0ex}}\mathrm{MeV}<{E}_{n}<80\phantom{\rule{0.16em}{0ex}}\mathrm{MeV}$ on $^{86}\mathrm{Kr}$: three $\ensuremath{\gamma}$ rays of $^{85}\mathrm{Kr}$ and one $\ensuremath{\gamma}$ ray each in $^{82,83,84}\mathrm{Kr}$ and $^{83,85}\mathrm{Br}$. A large part of the total cross section for the $^{86}\mathrm{Kr}(n,3n)^{84}\mathrm{Kr}$ reaction is experimentally observed. The results are compared with predictions from calculations using the ${\mathrm{CoH}}_{3}$ reaction code and are used to check on the consistency of the parameters in the calculations.- 10 October 2022
- Published by Office of Scientific and Technical Information (OSTI)
Two bright, optically clear, intrinsic fast-neutron and charged-particle detector materials for neutron imaging and other applications
The U.S. Department of Energy's Office of Scientific and Technical Information
- 10 October 2022
- Published by Office of Scientific and Technical Information (OSTI)
Two bright, optically clear, intrinsic fast-neutron and charged-particle detector materials for neutron imaging and other applications
The U.S. Department of Energy's Office of Scientific and Technical Information
- Open Access
- 16 November 2021
- Published by AIP Publishing in Journal of Applied Physics
- Vol. 130 (19) , 193102
Investigations of radiation damaged arranged scintillating particle composites
Composites consisting of periodically arranged scintillating particles within an acrylic (poly methyl methacrylate) matrix are excellent templates for the gamma-insensitive detection of fast neutrons. In order to study the impact of radiation damage on acrylic-based scintillating particle composites, we exposed acrylic samples to different doses of fast neutrons up to 119.7 kGy and investigated the change in optical characteristics using optical absorption spectroscopy in the 200–800 nm wavelength range. The experimental results are compared to coupled MCNP6 and optical ray-tracing (FRED) simulations, and qualitative agreement is found. Neutron-induced radiation damage in the acrylic matrix manifests as a red-shift in the ultra-violet absorption edge of the acrylic and a corresponding decrease in the light propagation efficiency, which leads to detector performance degradation. We show for the first time that the effects of radiation damage can be mitigated by the use of wavelength-shifting coatings. We predict that composites with wavelength-shifting coatings can enable neutron detectors with high tolerance against neutron-induced radiation damage, a property that is particularly desired for neutron detection in high radiation environments.
- 16 November 2021
- Published by AIP Publishing in Journal of Applied Physics
- Vol. 130 (19) , 193102
Open AccessInvestigations of radiation damaged arranged scintillating particle composites
Composites consisting of periodically arranged scintillating particles within an acrylic (poly methyl methacrylate) matrix are excellent templates for the gamma-insensitive detection of fast neutrons. In order to study the impact of radiation damage on acrylic-based scintillating particle composites, we exposed acrylic samples to different doses of fast neutrons up to 119.7 kGy and investigated the change in optical characteristics using optical absorption spectroscopy in the 200–800 nm wavelength range. The experimental results are compared to coupled MCNP6 and optical ray-tracing (FRED) simulations, and qualitative agreement is found. Neutron-induced radiation damage in the acrylic matrix manifests as a red-shift in the ultra-violet absorption edge of the acrylic and a corresponding decrease in the light propagation efficiency, which leads to detector performance degradation. We show for the first time that the effects of radiation damage can be mitigated by the use of wavelength-shifting coatings. We predict that composites with wavelength-shifting coatings can enable neutron detectors with high tolerance against neutron-induced radiation damage, a property that is particularly desired for neutron detection in high radiation environments.
- 1 April 2021
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 92 (4) , 043501
Neutron radiation hardness of aluminum gallium nitride UV LEDs at various wavelengths
Radiation hard diagnostics are critical to the success of nuclear fusion at National Ignition Facility, Z, ITER, and prolonged space explorations. We have first demonstrated the exceptional proton radiation hardness of initial GaN devices and qualified their space flight and deployment for missions such as the Laser Interferometer Space Antenna and International Space Station. We have further conducted neutron radiation hardness experiments at Los Alamos Neutron Science Center by opening a new high fluence beam station. During 2014–2016, we irradiated multiple Aluminum Gallium Nitride (AlGaN) LEDs with a maximum fluence of 2.4 × 1013 neutrons/cm2 in 3 years and generated 54 161 current–voltage (I–V) scan traces. Our data processing program analyzes each and all I–V traces. In addition, we retrieved local temperature records to analyze and remove temperature effects in the outdoor environment. The I–V curve families of AlGaN UV LEDs with emitting wavelengths of 265, 275, and 310 nm were compared. The I–V curves of 265 nm AlGaN UV LEDs have the smallest deviations from the average value, while the I–V curves for 310 nm AlGaN LEDs showed the largest deviations from the average value. We have reached another important recommendation for the optimal use of multiple AlGaN optoelectronic devices or imaging arrays for inertially confined fusion diagnostics: Shorter wavelength devices at 265 nm exhibit more consistent radiation hardness performance than the 310 nm devices. Higher aluminum content LEDs or AlxGa1–xN devices with higher mole fraction x for generating shorter wavelengths have better radiation hardness for fusion diagnostics.
- 1 April 2021
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 92 (4) , 043501
Neutron radiation hardness of aluminum gallium nitride UV LEDs at various wavelengths
Radiation hard diagnostics are critical to the success of nuclear fusion at National Ignition Facility, Z, ITER, and prolonged space explorations. We have first demonstrated the exceptional proton radiation hardness of initial GaN devices and qualified their space flight and deployment for missions such as the Laser Interferometer Space Antenna and International Space Station. We have further conducted neutron radiation hardness experiments at Los Alamos Neutron Science Center by opening a new high fluence beam station. During 2014–2016, we irradiated multiple Aluminum Gallium Nitride (AlGaN) LEDs with a maximum fluence of 2.4 × 1013 neutrons/cm2 in 3 years and generated 54 161 current–voltage (I–V) scan traces. Our data processing program analyzes each and all I–V traces. In addition, we retrieved local temperature records to analyze and remove temperature effects in the outdoor environment. The I–V curve families of AlGaN UV LEDs with emitting wavelengths of 265, 275, and 310 nm were compared. The I–V curves of 265 nm AlGaN UV LEDs have the smallest deviations from the average value, while the I–V curves for 310 nm AlGaN LEDs showed the largest deviations from the average value. We have reached another important recommendation for the optimal use of multiple AlGaN optoelectronic devices or imaging arrays for inertially confined fusion diagnostics: Shorter wavelength devices at 265 nm exhibit more consistent radiation hardness performance than the 310 nm devices. Higher aluminum content LEDs or AlxGa1–xN devices with higher mole fraction x for generating shorter wavelengths have better radiation hardness for fusion diagnostics.
- 21 April 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 67 (6) , 1086-1092
Neutron-Induced Radiation Damage in LYSO, BaF2, and PWO Crystals
One crucial issue for the application of scintillation crystals in future high-energy physics experiments is radiation damage in a severe radiation environment, such as the high luminosity large hadron collider. While radiation damage induced by ionization dose in inorganic scintillators is well understood, investigations are on-going to understand radiation damage induced by hadrons, including both charged hadrons and neutrons. Aiming at understanding neutron induced radiation damage in fast inorganic scintillators, LYSO/LFS, BaF2 and PWO crystals were irradiated at Los Alamos Neutron Science Center by a combination of particles, including neutrons, protons and γ-rays. The results indicate that LYSO/LFS and BaF2 crystal plates are radiation hard up to a 1 MeV equivalent neutrons fluence of 9 ×1015 neq/cm2, but not PWO, and the neutron-induced radiation damage in LYSO crystals is a factor of ten less than protons.
- 21 April 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 67 (6) , 1086-1092
Neutron-Induced Radiation Damage in LYSO, BaF2, and PWO Crystals
One crucial issue for the application of scintillation crystals in future high-energy physics experiments is radiation damage in a severe radiation environment, such as the high luminosity large hadron collider. While radiation damage induced by ionization dose in inorganic scintillators is well understood, investigations are on-going to understand radiation damage induced by hadrons, including both charged hadrons and neutrons. Aiming at understanding neutron induced radiation damage in fast inorganic scintillators, LYSO/LFS, BaF2 and PWO crystals were irradiated at Los Alamos Neutron Science Center by a combination of particles, including neutrons, protons and γ-rays. The results indicate that LYSO/LFS and BaF2 crystal plates are radiation hard up to a 1 MeV equivalent neutrons fluence of 9 ×1015 neq/cm2, but not PWO, and the neutron-induced radiation damage in LYSO crystals is a factor of ten less than protons.
- 20 May 2019
- Published by Office of Scientific and Technical Information (OSTI)
LANSCE Pulse
The U.S. Department of Energy's Office of Scientific and Technical Information
- 20 May 2019
- Published by Office of Scientific and Technical Information (OSTI)
LANSCE Pulse
The U.S. Department of Energy's Office of Scientific and Technical Information
- 1 October 2018
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 89 (10) , 10K113
Gallium nitride (GaN) devices as a platform technology for radiation hard inertial confinement fusion diagnostics
Inertial Confinement Fusion (ICF) is undergoing more detailed research to increase neutron yield and will require high resolution imaging near the target. Neutron damage to diagnostics remains a serious issue in understanding and achieving ICF. We have demonstrated that Gallium Nitride (GaN) optoelectronic devices have exceptional neutron radiation hardness, by systematic testing of neutron radiation effects in GaN devices and materials with elevated neutron fluence levels and a broad neutron energy spectrum. During the 2013-2017 run cycles at Los Alamos Neutron Science Center (LANSCE), we irradiated various GaN materials and devices with fast and thermal plus resonance neutrons at several beamlines. This paper presents a radiation hardness study for Aluminum Gallium Nitride and Gallium Nitride (AlGaN/GaN) deep UV LEDs irradiated at the LANSCE 4FP60R beamline. The fluence level was up to 2.4 × 1013 neutrons/cm2 for neutrons with energies greater than 0.1 MeV. The device performance was monitored in real time. After three years of irradiation studies, we found that the GaN devices maintained operation in the forward active region. The current and voltage relation (I-V curves) varied insignificantly in the linear region. Our results demonstrate the radiation hardness needed for laser fusion diagnostics at least up to 1017 neutron yield per shot, if the diagnostics is placed 1 m away from the target, where the neutron fluence per shot is approximately 8 × 1011 n/cm2. The GaN devices can operate for multiple shots.
- 1 October 2018
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 89 (10) , 10K113
Gallium nitride (GaN) devices as a platform technology for radiation hard inertial confinement fusion diagnostics
Inertial Confinement Fusion (ICF) is undergoing more detailed research to increase neutron yield and will require high resolution imaging near the target. Neutron damage to diagnostics remains a serious issue in understanding and achieving ICF. We have demonstrated that Gallium Nitride (GaN) optoelectronic devices have exceptional neutron radiation hardness, by systematic testing of neutron radiation effects in GaN devices and materials with elevated neutron fluence levels and a broad neutron energy spectrum. During the 2013-2017 run cycles at Los Alamos Neutron Science Center (LANSCE), we irradiated various GaN materials and devices with fast and thermal plus resonance neutrons at several beamlines. This paper presents a radiation hardness study for Aluminum Gallium Nitride and Gallium Nitride (AlGaN/GaN) deep UV LEDs irradiated at the LANSCE 4FP60R beamline. The fluence level was up to 2.4 × 1013 neutrons/cm2 for neutrons with energies greater than 0.1 MeV. The device performance was monitored in real time. After three years of irradiation studies, we found that the GaN devices maintained operation in the forward active region. The current and voltage relation (I-V curves) varied insignificantly in the linear region. Our results demonstrate the radiation hardness needed for laser fusion diagnostics at least up to 1017 neutron yield per shot, if the diagnostics is placed 1 m away from the target, where the neutron fluence per shot is approximately 8 × 1011 n/cm2. The GaN devices can operate for multiple shots.
- 27 October 2013
- Published by World Scientific Pub Co Pte Ltd
- p. 430-436
PROMPT FISSION NEUTRON SPECTRUM STUDY AT LANSCE: CHI-NU PROJECT
- 27 October 2013
- Published by World Scientific Pub Co Pte Ltd
- p. 430-436
PROMPT FISSION NEUTRON SPECTRUM STUDY AT LANSCE: CHI-NU PROJECT
- Open Access
- 13 June 2013
- Published by American Physical Society (APS) in Physical Review C
- Vol. 87 (6) , 064607
Neutron inelastic scattering in natural Cu as a background in neutrinoless double-decay experimentsBackground: Experiments designed to study rare processes, such as neutrinoless double- decay (), are crucial tests for physics beyond the standard model. These experiments rely on reducing the intrinsic radioactive background to unprecedented levels, while adequately shielding the detectors from external sources of radioactivity.- 13 June 2013
- Published by American Physical Society (APS) in Physical Review C
- Vol. 87 (6) , 064607
Open AccessNeutron inelastic scattering in natural Cu as a background in neutrinoless double-decay experimentsBackground: Experiments designed to study rare processes, such as neutrinoless double- decay (), are crucial tests for physics beyond the standard model. These experiments rely on reducing the intrinsic radioactive background to unprecedented levels, while adequately shielding the detectors from external sources of radioactivity.