LMLeto Mailli

Leto Mailli

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Leto Mailli has a total of 14 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Impact of site of occlusion in proximal splenic artery embolisation for blunt splenic trauma

    by A. Boscà-Ramon, L. Ratnam, T. Cavenagh, J-Y Chun, R. Morgan, M. Gonsalves, R. Das, S. Ameli-Renani, V. Pavlidis, B. Hawthorn, et al.

    Background: Proximal splenic artery embolisation (PSAE) can be performed in stable patients with Association for the Surgery of Trauma (AAST) grade III-V splenic injury. PSAE reduces splenic perfusion but maintains viability of the spleen and pancreas via the collateral circulation. The hypothesized ideal location is between the dorsal pancreatic artery (DPA) and great pancreatic artery (GPA). This study compares the outcomes resulting from PSAE embolisation in different locations along the splenic artery.Materials and methods: Retrospective review was performed of PSAE for blunt splenic trauma (2015–2020). Embolisation locations were divided into: Type I, proximal to DPA; Type II, DPA-GPA; Type III, distal to GPA. Fifty-eight patients underwent 59 PSAE: Type I (7); Type II (27); Type III (25). Data was collected on technical and clinical success, post-embolisation pancreatitis and splenic perfusion. Statistical significance was assessed using a chi-squared test.Results: Technical success was achieved in 100% of cases. Clinical success was 100% for Type I/II embolisation and 88% for Type III: one patient underwent reintervention and two had splenectomies for ongoing instability. Clinical success was significantly higher in Type II embolisation compared to Type III (p = 0.02). No episodes of pancreatitis occurred post-embolisation. Where post-procedural imaging was obtained, splenic perfusion remained 100% in Type I and II embolisation and 94% in Type III. Splenic perfusion was significantly higher in the theorized ideal Type II group compared to Type I and III combined (p = 0.01).Conclusion: The results support the proposed optimal embolisation location as being between the DPA and GPA.


  • Open Access

    Clinical experience with a shape memory polymer peripheral vascular embolisation plug: a case series

    by Robert A. Morgan, Ian Loftus, Lakshmi Ratnam, Raj Das, Leto Mailli, Mohamad S. Hamady, Kyriakos Lobotesis

    Background: Shape memory polymers are materials that are manufactured in a certain shape, can be stored in a temporary deformed shape, and then return to – or remember – their original shape upon exposure to external stimuli such as temperature and moisture. This property lends itself to application in endovascular medical devices. Peripheral vasculature embolisation devices incorporating this novel technology have become commercially available and this case series, where the data were collected as part of a post market registry, outlines initial clinical experience with these novel devices. Results: Eight cases are described in this series. The disease state/conditions for which embolisation was indicated were right common iliac artery aneurysms (n = 3), a type II endoleak into the thoracic aorta following thoracic endovascular aneurysm repair (n = 1), a left inferior gluteal artery aneurysm (n = 1), left internal iliac artery aneurysms (n = 2), and a case of splenomegaly, where splenectomy was planned after the embolisation procedure (n = 1). Target arteries were 5–10 mm in diameter. In each case, at least one IMPEDE Embolization Plug (IMP-Device) of an appropriate diameter was used. All procedures were technically successful and target vessel thrombosis was achieved in all cases. Follow-up imaging available during the 45–90-day data collection timeframe showed sustained vessel occlusion. This case series includes examples of situations commonly encountered when embolising the peripheral vasculature, namely, the use of one or multiple devices in a single vessel and in combination with the use of other embolic devices (e.g., microcoils, gelatin sponge, and PVA particles) in the same case. There were no adverse events related to the specific use of the device. Conclusions: This small series illustrates the safety and efficacy of this novel sponge-based embolic device for the embolisation of small and medium sized arteries and further experience will demonstrate the utility of the shape memory polymer devices.