Mani Arivazhagan
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Mani Arivazhagan has a total of 3 co-authors. Here are the top co-authors by number of shared publications:
- Govindhan Maduraiveeran
Materials Electrochemistry Laboratory, Department of Chemistry, SRM Institute of Science and Technology, Kattankulathur – 603 203, Chengalpattu, Tamil Nadu, India
2 shared publications - Palanisamy Kannan
Jiaxing University, Jiaxing, Zhejiang, 314001, China
1 shared publication - Yesupatham Manova Santhosh
Materials Electrochemistry Laboratory, Department of Chemistry, SRM Institute of Science and Technology, Kattankulathur 603 203, Tamil Nadu, India
1 shared publication
Latest Publications
- Open Access
- 5 December 2022
- Published by MDPI AG in Biosensors
- Vol. 12 (12) , 1128
Gold Nanoclusters Dispersed on Gold Dendrite-Based Carbon Fibre Microelectrodes for the Sensitive Detection of Nitric Oxide in Human Serum
Herein, gold nanoclusters (Au NC) dispersed on gold dendrite (Au DS)-based flexible carbon fibre (AuNC@AuDS|CF) microelectrodes are developed using a one-step electrochemical approach. The as-fabricated AuNC@AuDS|CF microelectrodes work as the prospective electrode materials for the sensitive detection of nitric oxide (NO) in a 0.1 M phosphate buffer (PB) solution. Carbon microfibre acts as an efficient matrix for the direct growth of AuNC@AuDS without any binder/extra reductant. The AuNC@AuDS|CF microelectrodes exhibit outstanding electrocatalytic activity towards NO oxidation, which is ascribed to their large electrochemical active surface area (ECSA), high electrical conductivity, and high dispersion of Au nanoclusters. As a result, the AuNC@AuDS|CF microelectrodes attain a rapid response time (3 s), a low limit of detection (LOD) (0.11 nM), high sensitivity (66.32 µA µM cm−2), a wide linear range (2 nM–7.7 µM), long-term stability, good reproducibility, and a strong anti-interference capability. Moreover, the present microsensor successfully tested for the discriminating detection of NO in real human serum samples, revealing its potential practicability.
- 5 December 2022
- Published by MDPI AG in Biosensors
- Vol. 12 (12) , 1128
Open AccessGold Nanoclusters Dispersed on Gold Dendrite-Based Carbon Fibre Microelectrodes for the Sensitive Detection of Nitric Oxide in Human Serum
Herein, gold nanoclusters (Au NC) dispersed on gold dendrite (Au DS)-based flexible carbon fibre (AuNC@AuDS|CF) microelectrodes are developed using a one-step electrochemical approach. The as-fabricated AuNC@AuDS|CF microelectrodes work as the prospective electrode materials for the sensitive detection of nitric oxide (NO) in a 0.1 M phosphate buffer (PB) solution. Carbon microfibre acts as an efficient matrix for the direct growth of AuNC@AuDS without any binder/extra reductant. The AuNC@AuDS|CF microelectrodes exhibit outstanding electrocatalytic activity towards NO oxidation, which is ascribed to their large electrochemical active surface area (ECSA), high electrical conductivity, and high dispersion of Au nanoclusters. As a result, the AuNC@AuDS|CF microelectrodes attain a rapid response time (3 s), a low limit of detection (LOD) (0.11 nM), high sensitivity (66.32 µA µM cm−2), a wide linear range (2 nM–7.7 µM), long-term stability, good reproducibility, and a strong anti-interference capability. Moreover, the present microsensor successfully tested for the discriminating detection of NO in real human serum samples, revealing its potential practicability.
- Open Access
- 5 April 2021
- Published by MDPI AG in Micromachines
- Vol. 12 (4) , 403
Non-Enzymatic Glucose Detection Based on NiS Nanoclusters@NiS Nanosphere in Human Serum and Urine
Herein, we report a non-enzymatic electrochemical glucose sensing platform based on NiS nanoclusters dispersed on NiS nanosphere (NC-NiS@NS-NiS) in human serum and urine samples. The NC-NiS@NS-NiS are directly grown on nickel foam (NF) (NC-NiS@NS-NiS|NF) substrate by a facile, and one-step electrodeposition strategy under acidic solution. The as-developed nanostructured NC-NiS@NS-NiS|NF electrode materials successfully employ as the enzyme-mimic electrocatalysts toward the improved electrocatalytic glucose oxidation and sensitive glucose sensing. The NC-NiS@NS-NiS|NF electrode presents an outstanding electrocatalytic activity and sensing capability towards the glucose owing to the attribution of great double layer capacitance, excessive electrochemical active surface area (ECASA), and high electrochemical active sites. The present sensor delivers a limit of detection (LOD) of ~0.0083 µM with a high sensitivity of 54.6 µA mM−1 cm−2 and a wide linear concentration range (20.0 µM–5.0 mM). The NC-NiS@NS-NiS|NF-based sensor demonstrates the good selectivity against the potential interferences and shows high practicability by glucose sensing in human urine and serum samples.
- 5 April 2021
- Published by MDPI AG in Micromachines
- Vol. 12 (4) , 403
Open AccessNon-Enzymatic Glucose Detection Based on NiS Nanoclusters@NiS Nanosphere in Human Serum and Urine
Herein, we report a non-enzymatic electrochemical glucose sensing platform based on NiS nanoclusters dispersed on NiS nanosphere (NC-NiS@NS-NiS) in human serum and urine samples. The NC-NiS@NS-NiS are directly grown on nickel foam (NF) (NC-NiS@NS-NiS|NF) substrate by a facile, and one-step electrodeposition strategy under acidic solution. The as-developed nanostructured NC-NiS@NS-NiS|NF electrode materials successfully employ as the enzyme-mimic electrocatalysts toward the improved electrocatalytic glucose oxidation and sensitive glucose sensing. The NC-NiS@NS-NiS|NF electrode presents an outstanding electrocatalytic activity and sensing capability towards the glucose owing to the attribution of great double layer capacitance, excessive electrochemical active surface area (ECASA), and high electrochemical active sites. The present sensor delivers a limit of detection (LOD) of ~0.0083 µM with a high sensitivity of 54.6 µA mM−1 cm−2 and a wide linear concentration range (20.0 µM–5.0 mM). The NC-NiS@NS-NiS|NF-based sensor demonstrates the good selectivity against the potential interferences and shows high practicability by glucose sensing in human urine and serum samples.