Oddgeir Gudmundsson
Oddgeir Gudmundsson has a total of 26 co-authors. Here are the top co-authors by number of shared publications:
- Jan Eric Thorsen
DCS Solutions & Technology
5 shared publications Anders Dyrelund
3 shared publicationsAhmad Arabkoohsar
2 shared publications- Henrik Lund
Aalborg University
2 shared publications Jan Eric Thorsen
2 shared publications- Michele Tunzi
DTU Construct, Technical University of Denmark
2 shared publications
Latest Publications
- 19 June 2026
- Published by Aalborg University in International Journal of Sustainable Energy Planning and Management
- Vol. 49, 37-52
Techno-Economic Comparison of Different District and Individual Heating and Cooling Systems
Various renewable and infrastructure options are available for decarbonising the heating sector and at the same time cooling is getting increasingly important. Existing approaches and tools for urban heat planning often require detailed modelling and often only address a limited range of heating and cooling (H&C) options. This paper introduces a simplified approach for quick assessment of 4th generation district heating (4GDH), thermal source networks and individual solutions. The approach uses publicly available datasets, a seasonal representation of energy balances and levelised cost indicators under limited early-stage data availability. The approach is validated by comparison with a detailed hourly feasibility study for a large-scale 4GDH case study in the UK. Cost deviations are within pre-feasibility screening ranges (± 30%), while component-level capacities and costs can differ due to deterministic peak sizing and network correlations, which result from the simplified representation of peak loads and network structures. Since these differences are generally acceptable, the proposed approach enables rapid, transparent comparison of H&C systems and thus can support early planning decisions.
- 19 June 2026
- Published by Aalborg University in International Journal of Sustainable Energy Planning and Management
- Vol. 49, 37-52
Techno-Economic Comparison of Different District and Individual Heating and Cooling Systems
Various renewable and infrastructure options are available for decarbonising the heating sector and at the same time cooling is getting increasingly important. Existing approaches and tools for urban heat planning often require detailed modelling and often only address a limited range of heating and cooling (H&C) options. This paper introduces a simplified approach for quick assessment of 4th generation district heating (4GDH), thermal source networks and individual solutions. The approach uses publicly available datasets, a seasonal representation of energy balances and levelised cost indicators under limited early-stage data availability. The approach is validated by comparison with a detailed hourly feasibility study for a large-scale 4GDH case study in the UK. Cost deviations are within pre-feasibility screening ranges (± 30%), while component-level capacities and costs can differ due to deterministic peak sizing and network correlations, which result from the simplified representation of peak loads and network structures. Since these differences are generally acceptable, the proposed approach enables rapid, transparent comparison of H&C systems and thus can support early planning decisions.
- Open Access
- 24 January 2026
- Published by Springer Nature
- p. 183-192
Improved District Heating Return Temperatures by Cascading Concepts
As the focus on the performance of district heating (DH) systems intensifies, this study explores three cascaded substation concepts to assess their potential for reducing the DH return temperature at the building level substation. A lower DH return temperature is crucial for lowering the DH flow temperature to optimal levels, thereby enhancing system efficiency, which is a key feature of 4th generation DH (4GDH). Within the ARV project ( https://greendeal-arv.eu ), DH substation concepts have been evaluated, including parallel, two-stage, aftercooling, and midcooling configurations, with the parallel concept serving as the baseline for comparison. The analysis, based on annual simulations, covers generalized parameter combinations to demonstrate the potential for DH return temperature reduction across the different substation concepts in comparison to the baseline. Additionally, the impact of various climate profiles is explored, represented by the locations of Copenhagen, Helsinki, Paris, and Rome. Field data from a two-year test of the aftercooling concept validates the analysis results. The aftercooling and midcooling concepts have a significant reduction potential in annual DH return temperatures by 3 to 9,5 °C for 4GDH operations, compared to the baseline system.
- 24 January 2026
- Published by Springer Nature
- p. 183-192
Open AccessImproved District Heating Return Temperatures by Cascading Concepts
As the focus on the performance of district heating (DH) systems intensifies, this study explores three cascaded substation concepts to assess their potential for reducing the DH return temperature at the building level substation. A lower DH return temperature is crucial for lowering the DH flow temperature to optimal levels, thereby enhancing system efficiency, which is a key feature of 4th generation DH (4GDH). Within the ARV project ( https://greendeal-arv.eu ), DH substation concepts have been evaluated, including parallel, two-stage, aftercooling, and midcooling configurations, with the parallel concept serving as the baseline for comparison. The analysis, based on annual simulations, covers generalized parameter combinations to demonstrate the potential for DH return temperature reduction across the different substation concepts in comparison to the baseline. Additionally, the impact of various climate profiles is explored, represented by the locations of Copenhagen, Helsinki, Paris, and Rome. Field data from a two-year test of the aftercooling concept validates the analysis results. The aftercooling and midcooling concepts have a significant reduction potential in annual DH return temperatures by 3 to 9,5 °C for 4GDH operations, compared to the baseline system.
- Open Access
Aftercooling concept: An innovative substation ready for 4th generation district heating networks
- Open Access
- 16 May 2022
- Published by Elsevier in Smart Energy
- Vol. 6
Source-to-sink efficiency of blue and green district heating and hydrogen-based heat supply systems
- 16 May 2022
- Published by Elsevier in Smart Energy
- Vol. 6
Open AccessSource-to-sink efficiency of blue and green district heating and hydrogen-based heat supply systems
- Top Cited PapersOpen Access
Perspectives on fourth and fifth generation district heating
- Open Access
- 29 March 2021
- Published by EDP Sciences
- Vol. 246, 09004
Comparison of 4th and 5th generation district heating systems
In a pursuit to increase the efficiency of district heating system there has been a continuous focus to reduce the system operating temperatures. This has led to the current state of the art district heating systems, commonly referred to as the 4th generation district heating, also known as low temperature district heating (LTDH). The success of the LTDH has fuelled a lot of research interest in district energy systems, one of the new research topics has been focusing on reducing the operating temperatures down to the ambient temperature (ATDH), commonly referred as 5th generation district heating. In these systems the supply temperature is insufficient for fulfilling the heating demands of the connected buildings, which then requires end-user located heat pumps to raise the supply temperature to the level required by the buildings. As of today, number of ATDH systems have been realized as part of various research projects. The question however remains if ATDH brings additional benefits compared to LTDH. This paper compares the levelized cost of heat from these two systems types for two countries with different climate zones. The results of the analysis indicate that LTDH is the favourable solution in both countries.
- 29 March 2021
- Published by EDP Sciences
- Vol. 246, 09004
Open AccessComparison of 4th and 5th generation district heating systems
In a pursuit to increase the efficiency of district heating system there has been a continuous focus to reduce the system operating temperatures. This has led to the current state of the art district heating systems, commonly referred to as the 4th generation district heating, also known as low temperature district heating (LTDH). The success of the LTDH has fuelled a lot of research interest in district energy systems, one of the new research topics has been focusing on reducing the operating temperatures down to the ambient temperature (ATDH), commonly referred as 5th generation district heating. In these systems the supply temperature is insufficient for fulfilling the heating demands of the connected buildings, which then requires end-user located heat pumps to raise the supply temperature to the level required by the buildings. As of today, number of ATDH systems have been realized as part of various research projects. The question however remains if ATDH brings additional benefits compared to LTDH. This paper compares the levelized cost of heat from these two systems types for two countries with different climate zones. The results of the analysis indicate that LTDH is the favourable solution in both countries.
- 25 March 2016
- Published by Taylor & Francis in Heat Transfer Engineering
- Vol. 37 (15) , 1231-1241
Online Fouling Detection of Domestic Hot Water Heat Exchangers
Due to hardness of cold water supply in many countries, there is a risk of fouling in domestic hot water (DHW) counterflow plate heat exchangers. The scaling will result in increased resistance to heat transfer, which has negative effects on the economics of the district heating network. A common approach is to clean or change the heat exchanger periodically, which can be expensive if only limited fouling has occurred (unnecessary) or if a higher than expected scaling layer has formed (inefficiency). A better approach is to monitor the state of the heat exchangers and clean them when actually required. This would result in more energy-efficient operation and provide an optimum schedule for heat exchanger cleaning. This can be simple if the heat exchangers are operating under steady-state conditions; however, if large variations in the inlets are experienced, as is the case with the mass flows in DHW heat exchangers, it quickly becomes impossible with standard methods. In this paper it is proposed to monitor the state of the heat exchanger online by using measurements that are easily obtainable under normal operation and applying fast mathematical models to estimate the overall heat transfer coefficient of the heat exchanger. The results show that the methods proposed can be used to detect fouling in DHW heat exchangers.
- 25 March 2016
- Published by Taylor & Francis in Heat Transfer Engineering
- Vol. 37 (15) , 1231-1241
Online Fouling Detection of Domestic Hot Water Heat Exchangers
Due to hardness of cold water supply in many countries, there is a risk of fouling in domestic hot water (DHW) counterflow plate heat exchangers. The scaling will result in increased resistance to heat transfer, which has negative effects on the economics of the district heating network. A common approach is to clean or change the heat exchanger periodically, which can be expensive if only limited fouling has occurred (unnecessary) or if a higher than expected scaling layer has formed (inefficiency). A better approach is to monitor the state of the heat exchangers and clean them when actually required. This would result in more energy-efficient operation and provide an optimum schedule for heat exchanger cleaning. This can be simple if the heat exchangers are operating under steady-state conditions; however, if large variations in the inlets are experienced, as is the case with the mass flows in DHW heat exchangers, it quickly becomes impossible with standard methods. In this paper it is proposed to monitor the state of the heat exchanger online by using measurements that are easily obtainable under normal operation and applying fast mathematical models to estimate the overall heat transfer coefficient of the heat exchanger. The results show that the methods proposed can be used to detect fouling in DHW heat exchangers.