Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Norman Pfeiffer has a total of 33 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Portable Impedance Analyzer for FET-Based Biosensors with Embedded Analysis of Randles Circuits’ Spectra

    by Norman Pfeiffer, Martin Bach, Alice Steiner, Anna-Elisabeth Gerhardt, Joan Bausells, Abdelhamid Errachid, Albert Heuberger

    The electrochemical impedance spectroscopy (EIS) is a measurement method for characterizing bio-recognition events of a sensor, such as field-effect transistor-based biosensors (BioFETs). Due to the lack of portable impedance spectroscopes, EIS applies mainly in laboratories preventing application-oriented use in the field. This work presents a portable impedance analyzer (PIA) providing a 4-channel EIS of BioFETs. It performs the analysis of the recorded spectra by determining the charge transfer resistance Rct with a power-saving algorithm. Therefore, a circle is fitted into the Nyquist representation of the Randles circuit, from whose zero crossings Rct can be determined. The introduced algorithm was evaluated on 100 simulated spectra of Randles circuits. To analyze the overall system, an adjustable reference circuit was developed that simulates configurable Randles circuits. Additional measurements with pH-sensitive ion-sensitive field-effect transistors (ISFETs) demonstrate the application of the measurement system with electrochemical sensors. Using simulated spectra, the circular fitting is able to detect Rct with a median accuracy of 1.2% at an average nominal power of 40 mW and 3054 µs computing time. The PIA with the embedded implementation of the circuit fitting achieves a median error for Rct of 4.2% using the introduced Randles circuit simulator (RCS). Measurements with ISFETs show deviations of 6.5 ± 2.8% compared to the complex non-linear least squares (CNLS), but is significantly faster and more efficient. The presented system allows a portable, power-saving performance of EIS. Future optimizations for a specific applications can improve the presented system and enable novel low-power and automated measurements of biosensors outside the laboratory.


  • Open Access

    An ImmunoFET Coupled with an Immunomagnetic Preconcentration Technique for the Sensitive EIS Detection of HF Biomarkers

    by Hamdi Ben Halima, Nadia Zine, Imad Abrao Nemeir, Norman Pfeiffer, Albert Heuberger, Joan Bausells, Abdelhamid Elaissari, Nicole Jaffrezic-Renault, Abdelhamid Errachid

    We propose a new strategy using a sandwich approach for the detection of two HF biomarkers: tumor necrosis factor-α (TNF-α) and interleukin-10 (IL-10). For this purpose, magnetic nanoparticles (MNPs) (MNPs@aminodextran) were biofunctionalized with monoclonal antibodies (mAbs) using bis (sulfosuccinimidyl) suberate (BS3) as a cross-linker for the pre-concentration of two biomarkers (TNF-α and IL-10). In addition, our ISFETs were biofunctionalized with polyclonal antibodies (pAbs) (TNF-α and IL-10). The biorecognition between pAbs immobilized on the ISFET and the pre-concentrate antigen (Ag) on MNPs was monitored using electrochemical impedance spectroscopy (EIS). Our developed ImmunoFET showed a low detection limit (0.03 pg/mL) toward our target analyte when compared to previously published electrochemical immunosensors. It showed a higher sensitivity than for other HF biomarkers. Finally, the standard addition method was used to determine the unknown concentration in artificial saliva. The results matched with the expected values well.


  • A novel electrochemical strategy for NT-proBNP detection using IMFET for monitoring heart failure by saliva analysis

    by Hamdi Ben Halima, Francesca G. Bellagambi, Marie Hangouët, Albert Alcacer, Norman Pfeiffer, Albert Heuberger, Nadia Zine, Joan Bausells, Abdelhamid Elaissari, Abdelhamid Errachid


  • Determination of Charge Transfer Resistance from Randles Circuit Spectra Using Elliptical Fitting

    by Norman Pfeiffer, Toni Wachter, Jürgen Frickel, Hamdi Ben Halima, Christian Hofmann, Abdelhamid Errachid, Albert Heuberger


  • A silicon nitride ISFET based immunosensor for tumor necrosis factor-alpha detection in saliva. A promising tool for heart failure monitoring

    by Hamdi Ben Halima, Francesca G. Bellagambi, Albert Alcacer, Norman Pfeiffer, Albert Heuberger, Marie Hangouët, Nadia Zine, Joan Bausells, Abdelhamid Elaissari, Abdelhamid Errachid


  • Open Access

    Wearable Current-Based ECG Monitoring System with Non-Insulated Electrodes for Underwater Application

    by Stefan Gradl, Tobias Cibis, Jasmine Lauber, Robert Richer, Ruslan Rybalko, Norman Pfeiffer, Heike Leutheuser, Markus Wirth, Vinzenz Von Tscharner, Bjoern M. Eskofier

    The second most common cause of diving fatalities is cardiovascular diseases. Monitoring the cardiovascular system in actual underwater conditions is necessary to gain insights into cardiac activity during immersion and to trigger preventive measures. We developed a wearable, current-based electrocardiogram (ECG) device in the eco-system of the FitnessSHIRT platform. It can be used for normal/dry ECG measuring purposes but is specifically designed to allow underwater signal acquisition without having to use insulated electrodes. Our design is based on a transimpedance amplifier circuit including active current feedback. We integrated additional cascaded filter components to counter noise characteristics specific to the immersed condition of such a system. The results of the evaluation show that our design is able to deliver high-quality ECG signals underwater with no interferences or loss of signal quality. To further evaluate the applicability of the system, we performed an applied study with it using 12 healthy subjects to examine whether differences in the heart rate variability exist between sitting and supine positions of the human body immersed in water and outside of it. We saw significant differences, for example, in the RMSSD and SDSD between sitting outside the water (36 ms) and sitting immersed in water (76 ms) and the pNN50 outside the water (6.4%) and immersed in water (18.2%). The power spectral density for the sitting positions in the TP and HF increased significantly during water immersion while the LF/HF decreased significantly. No significant changes were found for the supine position.