IMIbrahim A. Metwally

Ibrahim A. Metwally

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Ibrahim A. Metwally has a total of 17 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Effectiveness and Robustness Design of 500 kV HVDC Presaturated Iron-Core Fault Current Limiters

    by Mohamed Eladawy, Ibrahim A. Metwally

    This paper presents a novel full-scale compact design of $500\ {\text{kV}}$ HVDC, with rated pre-fault steady-state and fault currents of $2\ {\text{kA}}$ and $10\ {\text{kA}}$, respectively, presaturated core fault current limiter (PFCL) through connecting two series units rated $250\ {\text{kV}}$ each. It can replace the conventionally used PFCL in the form of a bulk CI (letters: CI) iron-core by a much smaller six CI iron-core units arranged on the six sides of a regular hexagon. The PFCL design and performance improvement are carried out through three-dimensional (3D) finite-element (FE) simulation using COMSOL Multiphysics. The time-varying fault inductance value significantly depends on the line coil generated magnetomotive force (mmf). The PFCL line coils are subdivided and wound by $500\ {\text{kV}}$ cross-linked polyethylene (XPLE) cables. The total high induced voltage across the presaturation coil is eliminated by subdividing it into subcoils orthogonally distributed around the iron core and differentially connected in series. A laboratory-scale PFCL is developed to validate FE simulation results of the time-varying current at different presaturation current, and a good agreement is found between both of them. The design capability can be extended by adding more CI-core units located on the sides of both regular octagonal and regular decagonal, or by increasing the design dimensions by an overall geometry scale factor. This modular topology gives substantial reduction in the iron-core volume (cost-effective design), superior performance, enhanced longevity, reliability, and flexibility in controllability and upgrading.


  • Open Access

    Presaturated iron‐core fault current limiters for MVDC power system applications

    by Ibrahim A. Metwally, Mohamed Eladawy

    This paper presents design and dynamic performance investigation of a full‐scale, modular topology (arranged on the sides of a regular hexagon), medium voltage direct current (MVDC) permanent magnet (PM) biased presaturated fault current limiter (PMFCL). This PMFCL represents a cost‐effective design with enhanced longevity, reliability, scalability, and controllability. The scalability of this modular design can be extended by adding or removing CI (letters: CI) core units for different power system applications in a voltage range from to or more. The rated steady‐state (DC) and fault currents of and , respectively. The detection free and self‐triggering performance of this PMFCL is designed and simulated through a 3D coupled model of electric‐circuit magnetic‐field of COMSOL Multiphysics. Accurate representation of PM behaviour, especially in the second quadrant of its hysteresis loop of Jiles‐Atherton method gives realistic performance of the PMFCL. Comprehensive finite element simulations are carried out to study the effect of design parameters on the dynamic performance of PMFCL. Good agreement is found between COMSOL simulation results of DC‐biased PFCL and experimental results of a developed small‐scale prototype. Results reveal that the MVDC PMFCL shows significant improvement and satisfactory performance, in terms of fault current clipping ratio, fault current slope, and power losses, as compared to the conventional MVDC DC‐biased presaturated CI iron‐core fault current limiter (PFCL).


  • Performance Improvement of Different Resonant Inductive Couplers Used for Wireless Power Transfer

    by Mohamed Eladawy, Ibrahim A. Metwally

    This paper experimentally investigates the performance of spiral coil configurations commonly used in the magnetic resonant wireless power transfer (WPT) inductive couplers. Three different designs are illustrated, namely, single-core, twin-core “bifilar”, and single-core coaxial cable spiral coils. The major concern is the improvement of both the voltage gain and transmitted power efficiency at different distances between the transmitter and receiver coils. Moreover, the performance analysis of the experimental setup is compared with the results of three-dimensional frequency-domain extensive finite element (FE) simulations of COMSOL Multiphysics package, through radio frequency modelling of coupled electromagnetic waves and electric circuits. Such FE simulations help in realizing the relative effect of inherent parameters that are hardly to be investigated through experimental measurement without disturbing the WPT system. Additionally, PSPICE is used to facilitate the performance investigation of such magnetic resonant WPT couplers. Results reveal that adding the ferrite sheets to single-core spiral coils helps in improving the WPT efficiency. Shorted bifilar wound flat spiral coils show higher WPT efficiency at short coil separation due to their intrinsic self-capacitance and high self-inductance. Self-resonating “capacitorless”, single-core coaxial cable wound flat spiral coils show an enhanced performance improvement when compared with the other two designs.


  • Open Access

    DC‐presaturated fault current limiter for high voltage direct current transmission systems

    by Mohamed Eladawy, Ibrahim A. Metwally, Naser G. Tarhuni

    The authors present a 500 kV real‐dimension DC‐presaturated fault current limiter (PFCL) with a steady‐state rated current of 2 kA for limiting large fault current of 8 kA with high rate of rise. These characteristics of the fault current can be a threat to high voltage direct current (HVDC) transmission systems, and hence PFCL design and performance improvement are investigated through three‐dimensional, time‐domain, magnetic‐field and electric‐circuit coupled model using finite element simulation of COMSOL Multiphysics package. The nonlinear magnetic characteristics of the soft magnet ensure variable inductance depending on demagnetisation magnetomotive force generated by the line current. This DC‐biased PFCL can replace the traditional smoothing reactor during the normal operation of the system by controlling the level of presaturation. In addition, PFCL is a self‐triggered device and therefore it can automatically limit the fault current and reduce its value below the interruption rating of the used HVDC circuit breakers (CBs). Moreover, the rate of rise of the fault current can be controlled to ensure the compatibility with the available type of HVDC CBs. The dynamic performance of PFCL is investigated during fault condition through the fault current clipping ratio and rate of rise of the fault current, and during steady‐state operation through the voltage drop across PFCL and its power losses. It is found that the proposed PFCL presents adequate capability in limiting large fault currents with extremely low values of voltage drop and power losses during the steady‐state condition. However, the switching transient overvoltages that appear at terminals of PFCL coils during the fault duration have been successfully suppressed by carefully selected ratings of zinc‐oxide surge arresters.


  • Open Access

    Influence of Driven Rods on Performance of Grounding Grids in Stratified Soils.(Dept.E)

    by Magdi Mohamed Ali El-Saadawi, I. A. Metwally, S. A . El-Driedy

    The variation in soil structure has a great infleunce on the grounding grid performance. This influnce can be measured in terms of ground resistance, touch and step potentials. The addition of driven rods 10 the grid significantly affects the grounding grid performance. This paper presents a comprehensive experimental study for the influence of adding driven rods on the performance of grounding grids. The study is applied on three constructed scale models. The models have been performed to simulate a single-, double- and triple-layer soils. A comparison between results obtained experimentally and that computed by mathematical equations is introduced.

  • Open Access

    Multiple Xenosteroid Pollutants Biomarker Changes in Cultured Nile Tilapia Using Wastewater Effluents as Their Primary Water Source

    by Eman Zahran, Mohammed Elmetwally, Walaa Awadin, Mansour El-Matbouli

    This study was undertaken to screen levels of xenosteroids (estrogenic endocrine disrupting chemicals/E-EDCs) in Nile tilapia (Oreochromis niloticus) fish farms subjected to water fill from the drain at three sites S1 (highly polluted), S2 (moderately polluted), and a putative reference site (RS). Biometric, hormonal, gene expression, and histopathological analysis were investigated. Testosterone, progesterone, and zeranol residues were detected at (0.12–3.44 µg/L) in water samples of different sites. Bisphenol-A (BPA) exhibited a very high concentration (6.5 µg/mL) in water samples from S1. Testosterone, 17β-estradiol residues were detected in fish tissues from all sites at (0.16–3.8 µg/Kg) and (1.05–5.01 µg/Kg), respectively. BPA residues were detected at a very high concentration in the liver and muscle of fish collected from S1 at higher levels of 25.9 and 48.07 µg/Kg, respectively. The detected E-EDCs, at different sites, particularly BPA, reduced the somatic and testicular growth among sites and oversampling time points. Meanwhile, hepatosomatic index (HSI) was significantly increased in S1 compared to S2. All analyzed genes estrogen receptor-type I (er-I, er-ɑ) and II (er-II, er-ß1), polypeptide 1a (cyp19a1), SRY-box containing gene 9 (sox9), and vitellogenin (vtg) and gonadotropin hormones (luteinizing hormone (LH), follicle-stimulating hormone (FSH)), testosterone, 17β-estradiol, and anti-Mullerian hormone (AMH) were significantly expressed at S1 compared to other sites. Histopathology was more evident in S1 than other sites. These findings warrant immediate strategies development to control aquatic pollution and maintain fish welfare and aquaculture sustainability.


  • A Comparative Investigation of Presaturated Core Fault Current Limiters Biased by DC Current and Permanent Magnet

    by Mohamed Eladawy, Ibrahim A. Metwally

    In this paper, the dc biasing magnetomotive force (mmf) in presaturated core fault current limiter (PCFCL) is replaced with permanent magnet (PM) to overcome the well-known drawbacks of the dc biased PCFCLs. These drawbacks are excessively induced voltage across the terminals of the dc coil during fault condition and high total power losses during the steady-state condition. The novel contributions of this paper are the introduction of the selection criteria of PM material and its representation by actual nonlinear B-H hysteresis loop of Jiles-Atherton method, and the use of PM alone as an equivalent to the dc biasing coils for three-phase fault current limiter (FCL), contrary to work reported in earlier papers. Single- and three-phase PCFCLs are modified by replacement of dc saturation coil by the equivalent PM through time-domain finite element (FE) simulation of COMSOL Multiphysics package. Experimental verification shows that the implementation of accurate nonlinear representation of PM demagnetization curve with FE simulation gives a realistic performance of the PM biased PCFCL, especially in the fault condition. The performance of PCFCL can be evaluated through the voltage drop and total power losses during the steady-state condition and the fault current clipping ratio during fault condition of the grid. Furthermore, a comparative investigation of dynamic behavior is considered between dc and PM biased PCFCLs. It is found that the PM biased PCFCL has enriched capability of limiting any type of fault current with leading advantages of reduced voltage drop and power losses significantly together with risk elimination of the high induced voltage across dc coil terminals. Moreover, the governing parameters of PM biased PCFCLs are subjected to performance analysis to study their inherent effects.


  • A Novel Five-Leg Design for Performance Improvement of Three-Phase Presaturated Core Fault-Current Limiter

    by Mohamed Eladawy, Ibrahim A. Metwally

    In this paper, a novel five-leg design of non-superconducting, three-phase, presaturated core fault-current limiter (PCFCL) is proposed based on the time-domain, electromagnetic finite-element simulations to overcome the main drawbacks of the well-known topologies of PCFCLs. These drawbacks are large volume of magnetic iron core, high total power loss under steady-state condition, high-induced voltage across the dc coil terminals during the fault condition, and the technical risks of high-temperature superconducting coil and cryogenics in the case of superconducting fault-current limiter (SFCLs). The general performance of PCFCL can be expressed through the steady-state power loss and voltage drop, and fault-current clipping ratio and the induced voltage across the dc coil terminals during the fault condition. Different topologies of three-phase PCFCLs are considered with the comparison of their limiting capability for different types of faults. The results reveal that the proposed design of PCFCL has superior properties in limiting any type of fault currents with reduced volume of the magnetic iron core, total power loss, and the induced voltage across the dc coil terminals in comparison with those of the well-known dual-core PCFCL design. Furthermore, a performance analysis of the novel five-leg design is considered throughout an extensive simulation of the constructive controlling parameters to study their relative effects on the general performance of operation.


  • Measurement of High Pulsed Currents Through Plates by Novel Linear Side-Looking Coils

    by Ibrahim A. Metwally

    This paper presents a design and calibration of six novel linear side-looking “Rogowski” coils to measure impulse currents through plates. This special design of Rogowski coils enables the measurement of impulse currents in some applications, where such measurements are very difficult to be achieved using the toroidal Rogowski coils. The six designed coils are divided into two sets based on the coil-operating mode. The first set consists of three coils, which are wound in a single layer by varnished wires on perspex and ferrite rods, and they are operated in differentiating mode with external passive integrators. The second set consists of three coils, which are wound in a single layer or flat spiral by coaxial cables on ferrite rod or cylinders, and they are operated in self-integrating mode with non-inductive termination resistance. For each set of coils, the integrator parameters and coil-termination resistance values are optimized in order to have a wider bandwidth and to avoid any droop effect. The designed six coils are calibrated using different over damped unidirectional and oscillatory impulse currents up to 12 kA. Two commercial impulse current transformers, namely, ICT1 and ICT2, simultaneously measure these currents. The modeling results reveal that most of the designed coils have sensitivity in the range from few tens to few hundreds mV/kA and bandwidth in the order of MHz. Finally, the results are interpreted in terms of frequency response analysis, and the correlation between coil performance, and both the current density distribution in the plate and the produced magnetic flux density.