Jason K. Ellis
Research Subjects
Research Interests
Jason K. Ellis has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
Andrei Iagaru
Division of Nuclear Medicine and Molecular Imaging, Department of Radiology, Stanford University, Stanford, USA
1 shared publicationBenjamin L. Franc
Division of Nuclear Medicine and Molecular Imaging, Department of Radiology, Stanford University, Stanford, USA
1 shared publicationClaudia Zacharias
Clinic for Nuclear Medicine, University Hospital Essen, Essen, Germany
1 shared publication- Guido Davidzon
Stanford University
1 shared publication Mary Ellen Koran
Division of Nuclear Medicine and Molecular Imaging, Department of Radiology, Stanford University, Stanford, USA
1 shared publicationTomomi Nobashi
Division of Nuclear Medicine and Molecular Imaging, Department of Radiology, Stanford University, Stanford, USA
1 shared publication
Latest Publications
- 28 October 2019
- Published by Springer Nature in Journal of Digital Imaging
- Vol. 33 (2) , 447-455
Performance Comparison of Individual and Ensemble CNN Models for the Classification of Brain 18F-FDG-PET Scans
The high-background glucose metabolism of normal gray matter on [18F]-fluoro-2-D-deoxyglucose (FDG) positron emission tomography (PET) of the brain results in a low signal-to-background ratio, potentially increasing the possibility of missing important findings in patients with intracranial malignancies. To explore the strategy of using a deep learning classifier to aid in distinguishing normal versus abnormal findings on PET brain images, this study evaluated the performance of a two-dimensional convolutional neural network (2D-CNN) to classify FDG PET brain scans as normal (N) or abnormal (A). Methods: Two hundred eighty-nine brain FDG-PET scans (N; n = 150, A; n = 139) resulting in a total of 68,260 images were included. Nine individual 2D-CNN models with three different window settings for axial, coronal, and sagittal axes were trained and validated. The performance of these individual and ensemble models was evaluated and compared using a test dataset. Odds ratio, Akaike’s information criterion (AIC), and area under curve (AUC) on receiver-operative-characteristic curve, accuracy, and standard deviation (SD) were calculated. Results: An optimal window setting to classify normal and abnormal scans was different for each axis of the individual models. An ensembled model using different axes with an optimized window setting (window-triad) showed better performance than ensembled models using the same axis and different windows settings (axis-triad). Increase in odds ratio and decrease in SD were observed in both axis-triad and window-triad models compared with individual models, whereas improvements of AUC and AIC were seen in window-triad models. An overall model averaging the probabilities of all individual models showed the best accuracy of 82.0%. Conclusions: Data ensemble using different window settings and axes was effective to improve 2D-CNN performance parameters for the classification of brain FDG-PET scans. If prospectively validated with a larger cohort of patients, similar models could provide decision support in a clinical setting.
- 28 October 2019
- Published by Springer Nature in Journal of Digital Imaging
- Vol. 33 (2) , 447-455
Performance Comparison of Individual and Ensemble CNN Models for the Classification of Brain 18F-FDG-PET Scans
The high-background glucose metabolism of normal gray matter on [18F]-fluoro-2-D-deoxyglucose (FDG) positron emission tomography (PET) of the brain results in a low signal-to-background ratio, potentially increasing the possibility of missing important findings in patients with intracranial malignancies. To explore the strategy of using a deep learning classifier to aid in distinguishing normal versus abnormal findings on PET brain images, this study evaluated the performance of a two-dimensional convolutional neural network (2D-CNN) to classify FDG PET brain scans as normal (N) or abnormal (A). Methods: Two hundred eighty-nine brain FDG-PET scans (N; n = 150, A; n = 139) resulting in a total of 68,260 images were included. Nine individual 2D-CNN models with three different window settings for axial, coronal, and sagittal axes were trained and validated. The performance of these individual and ensemble models was evaluated and compared using a test dataset. Odds ratio, Akaike’s information criterion (AIC), and area under curve (AUC) on receiver-operative-characteristic curve, accuracy, and standard deviation (SD) were calculated. Results: An optimal window setting to classify normal and abnormal scans was different for each axis of the individual models. An ensembled model using different axes with an optimized window setting (window-triad) showed better performance than ensembled models using the same axis and different windows settings (axis-triad). Increase in odds ratio and decrease in SD were observed in both axis-triad and window-triad models compared with individual models, whereas improvements of AUC and AIC were seen in window-triad models. An overall model averaging the probabilities of all individual models showed the best accuracy of 82.0%. Conclusions: Data ensemble using different window settings and axes was effective to improve 2D-CNN performance parameters for the classification of brain FDG-PET scans. If prospectively validated with a larger cohort of patients, similar models could provide decision support in a clinical setting.