Ivica Ravić
Research Subjects
Research Interests
Ivica Ravić has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
- Danijela Horvatek Tomić
Department of Poultry Diseases with Clinic, Faculty of Veterinary Medicine, University of Zagreb, 10000 Zagreb, Croatia
2 shared publications - Mario Ostović
Department of Animal Hygiene, Behavior and Welfare, Faculty of Veterinary Medicine, University of Zagreb, 10000 Zagreb, Croatia
2 shared publications - Matija Kovačić
Kovačić Family Farm, Šopron, 48267 Orehovec, Croatia
2 shared publications - Željko Gottstein
Department of Poultry Diseases, Faculty of Veterinary Medicine University of Zagreb
2 shared publications - Anamaria Ekert Kabalin
Department of Animal Breeding and Livestock Production, Faculty of Veterinary Medicine, University of Zagreb, 10000 Zagreb, Croatia
1 shared publication - Anamaria Ekert Kabalin
Department of Animal Breeding and Livestock Production, Faculty of Veterinary Medicine, University of Zagreb, 10000 Zagreb, Croatia
1 shared publication
Latest Publications
- Open Access
- 18 May 2024
- Published by MDPI AG in Agriculture
- Vol. 14 (5) , 778
Dust and Bacterial Air Contamination in a Broiler House in Summer and Winter
This study aimed to investigate dust and bacterial air contamination in a broiler house during different seasons. The study was carried out in commercial housing conditions during five weeks of the rearing cycle in summer and winter. The total dust concentration ranged from 1.90 to 4.50 mg/m3 in summer and from 2.80 to 5.10 mg/m3 in winter. The total bacterial count ranged from 2.85 × 104 to 1.03 × 105 CFU/m3 in summer and from 2.12 × 104 to 2.28 × 105 CFU/m3 in winter. The study results showed the dust concentration to be increased in winter as compared to summer, yielding a significant correlation (r = 0.602, p < 0.05) with a significantly higher airborne bacterial count in winter (p < 0.001). Furthermore, dust concentration showed significant correlations (p < 0.05) with air temperature (r = −0.418), relative humidity (r = 0.673), and broiler activity (r = 0.709), while bacterial count yielded significant correlations (p < 0.05) with air temperature (r = −0.756), relative humidity (r = 0.831), and airflow rate (r = 0.511). The results obtained in the study can prove useful in the field. Seasonal variability in dust and bacterial air contamination should be considered in the development of guidelines or standards of air quality in broiler housing and evaluation of the effectiveness of remedial strategies.
- 18 May 2024
- Published by MDPI AG in Agriculture
- Vol. 14 (5) , 778
Open AccessDust and Bacterial Air Contamination in a Broiler House in Summer and Winter
This study aimed to investigate dust and bacterial air contamination in a broiler house during different seasons. The study was carried out in commercial housing conditions during five weeks of the rearing cycle in summer and winter. The total dust concentration ranged from 1.90 to 4.50 mg/m3 in summer and from 2.80 to 5.10 mg/m3 in winter. The total bacterial count ranged from 2.85 × 104 to 1.03 × 105 CFU/m3 in summer and from 2.12 × 104 to 2.28 × 105 CFU/m3 in winter. The study results showed the dust concentration to be increased in winter as compared to summer, yielding a significant correlation (r = 0.602, p < 0.05) with a significantly higher airborne bacterial count in winter (p < 0.001). Furthermore, dust concentration showed significant correlations (p < 0.05) with air temperature (r = −0.418), relative humidity (r = 0.673), and broiler activity (r = 0.709), while bacterial count yielded significant correlations (p < 0.05) with air temperature (r = −0.756), relative humidity (r = 0.831), and airflow rate (r = 0.511). The results obtained in the study can prove useful in the field. Seasonal variability in dust and bacterial air contamination should be considered in the development of guidelines or standards of air quality in broiler housing and evaluation of the effectiveness of remedial strategies.
- Open Access
- 6 April 2021
- Published by MDPI AG in Atmosphere
- Vol. 12 (4) , 459
Effects of Season and House Microclimate on Fungal Flora in Air and Broiler Trachea
Fungi are present in abundance in poultry housing. The aim of the study was to assess the effect of season and microclimate parameters in poultry housing on fungal flora in the air and broiler trachea in commercial fattening conditions. The study was conducted in summer and winter. Study results indicated seasonal impact and association between fungal flora composition in housing air and broiler trachea. However, the total fungal count in housing air was significantly higher in summer and in broiler trachea in winter, both significantly correlated with indoor relative humidity and ammonia concentration. There was no significant correlation between outdoor and indoor air temperature, relative humidity and airflow rate, respectively. Study results suggested that environmental determination of fungi should be accompanied by their determination in broilers. In addition, seasonal impact on fungal contamination should be associated with microclimate conditions in the poultry house rather than the season itself. The fungi detected and the results obtained have implications not only for broiler health but also for the health of humans working in such environments.
- 6 April 2021
- Published by MDPI AG in Atmosphere
- Vol. 12 (4) , 459
Open AccessEffects of Season and House Microclimate on Fungal Flora in Air and Broiler Trachea
Fungi are present in abundance in poultry housing. The aim of the study was to assess the effect of season and microclimate parameters in poultry housing on fungal flora in the air and broiler trachea in commercial fattening conditions. The study was conducted in summer and winter. Study results indicated seasonal impact and association between fungal flora composition in housing air and broiler trachea. However, the total fungal count in housing air was significantly higher in summer and in broiler trachea in winter, both significantly correlated with indoor relative humidity and ammonia concentration. There was no significant correlation between outdoor and indoor air temperature, relative humidity and airflow rate, respectively. Study results suggested that environmental determination of fungi should be accompanied by their determination in broilers. In addition, seasonal impact on fungal contamination should be associated with microclimate conditions in the poultry house rather than the season itself. The fungi detected and the results obtained have implications not only for broiler health but also for the health of humans working in such environments.