RSRoman V. Studenikin

Roman V. Studenikin

*This is an algorithmically generated author record based on publicly available information.

Roman V. Studenikin has a total of 13 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • DIGITAL PROTOCOL AND PREDICTABLE REHABILITATION IN THE CONCEPT OF IMMEDIATE LOADING OF IMPLANTS IN COMPLETELY EDENTIAL CASES

    by R.V. Studenikin, E.G. Borisov, A.V. Povolotsky

    The modern realities of implantology require combining a digital approach with technology that determines the implant loading period, taking into account the biomechanical parameters affecting osseointegration. A unified clinical and engineering process, from diagnosis and planning to surgery with prosthetic fabrication in a milling center, is implemented within the framework of fully digital automated production. The aim of this study was to familiarize practicing physicians with the technique of immediate loading of implants in completely edentulous patients. The clinical case presented by the authors concerns a completely edentulous upper jaw using a removable implant-supported prosthesis. The time from examination to temporary prosthesis installation was approximately four days. This clinical case of a completely edentulous upper jaw illustrates an innovative approach that significantly reduces patient rehabilitation time and the risk of communication errors within the specialist team. The use of a modern scanning approach improves the accuracy of the prosthetic structure's fit to the foundations of both temporary and permanent bridge structures. Implant survival monitoring after 3, 6, and 12 months demonstrates good bone regeneration and the absence of bone resorption. Predicting the implant loading period using the Dr. Student software package and the COMMUNICATOR system as a technical guide allows the entire team of specialists to follow a predetermined path, from collecting parameters responsible for implant integration and a navigation protocol to fabrication and fixation of the structure obtained after scanning on the day of surgery.

  • PREDICTION OF THE IMMEDIATE LOAD ON IMPLANTS WITH FULL ADENTIA USING DIGITAL SOLUTIONS AND INTELLIGENT ASSISTANTS

    by R.V. Studenikin, E.G. Borisova, A.а. Povolotskaya

    The authors have implemented a treatment protocol in clinical practice using an intelligent system that predicts the duration of orthopedic loading on implants, taking into account parameters that affect implant osseointegration. This system also utilizes digital technologies that enable all stages of diagnosis, planning, surgical intervention, prosthesis fabrication in a milling center, and its installation in the oral cavity. The aim of the study was to evaluate the survival rate of completely edentulous implants using a temporary structure with immediate loading, taking into account the predicted data of artificial intelligence. The article presents a clinical case of completely edentulous maxilla, which allowed for the patient's rehabilitation using a conditionally removable structure on implants and the restoration of chewing function in the oral cavity. The digital protocol, which was developed by the authors and implemented in clinical practice, was adjusted according to the clinical case. After three and six months, radiographic monitoring of implant survival was performed. The radiographic examination data indicate the absence of bone resorption. The obtained results suggest that this approach significantly accelerates the patient's rehabilitation time. Thus, the period from the initial examination and digital data collection to the installation of a temporary removable appliance takes only five days. Managing patients using a digital protocol for predictive rehabilitation not only reduces the likelihood of dental errors but also shortens the number of treatment stages and duration, while improving the patient's quality of life.


  • Open Access

    Digital Technologies and Artificial Intelligence in the Protocol for Immediate Loading of Implants with Complete Edentia

    by N.N. Burdenko Voronezh State Medical University, Roman V. Studenikin, Oleg I. Volovikov, Vash Stomatolog Dentistry Clinic, Artem V. Povolockii, Nsd Clinic Llc, Andrey V. Sushhenko

    The article describes the clinical case of a patient with completely edentulous lower jaw requiring rehabilitation with the help of a fixed prosthesis on implants, which allowed restoring the functions of the oral cavity. A developed protocol for immediate loading of a temporary structure on implants was tested. It is implemented as a complex combination of artificial intelligence that predicts the duration of the orthopedic load based on the parameters affecting osseointegration, and digital technologies covering the entire cycle of examination, planning, surgical intervention, 3D printing of the prosthesis and its installation. The results obtained suggest that this approach significantly reduces the patient’s rehabilitation time - the time from the start of the initial examination to the installation of a temporary structure took only 7 hours. After three and six months, radiographic monitoring of implant survival was carried out. The data indicate the absence of bone resorption.


  • Open Access

    Influence of geometrical parameters of dental implants on secondary stability and osseointegration process depending on the type of bone

    by R. V. Studenikin, A. V. Sushchenko, A. A. Mamedov

    Aim. Comparison of the secondary stability and osseointegration rate of dental implants with fine and coarse threads placed in bones of various types.Materials and Methods. The study considered the data of 60 implants with fine and coarse threads, installed in the bone types I-III. After two and six months, an analysis of the loss of marginal bone, micromotion tests were carried out, changes in the stability coefficients were determined by the method of frequency magnetic resonance.Results. The 30 coarse threaded implants showed higher secondary stability compared to the finely threaded implants in all three bone types. Marginal bone loss was observed for both types of implants only in type III bone – but when comparing the absolute values, it is noticeable that they are smaller with large threads. Micromotion was absent in all cases for bone types I and II. For implants with large threads in type III bone, micromotion was less than 30 μm, and for implants with fine threads, it was 150-160 μm.Conclusions. High secondary stability is typical for implants installed in type I-II bone, regardless of the thread pitch, but the value of the stability coefficient is higher for specimens with coarse threads. In addition, there is no loss of marginal bone in these cases. Finely threaded implants placed in Type III bone are subject to micromovement.


  • One-stage dental implantation without orthopedic loads – histological and radiographic control of survival

    by R. V. Studenikin, A. A. Filin, A. A. Mamedov, K. S. Niftaliev

    Purpose: histological and radiographic study and comparison of osseointegration and stability of implants without orthopedic load, installed in different ways (simultaneously in a fresh socket immediately after tooth extraction and in mature bone).Materials and methods: the criterion for inclusion in the study was the possibility of placing a test (immediately after tooth extraction) and a control implant (in mature bone) on opposite sites without the use of osteoplastic materials or membranes. The procedures were followed by periapical radiography, which was repeated three months later. According to the comparative data of the images, the marginal loss of bone tissue was calculated. Both implants were removed to obtain histological specimens. Sections were prepared by standard staining with hematoxylin and eosin. Using an X-ray digitizer, the percentage of implant-to-bone connection was calculated.Results: the data of histological and radiographic studies showed no significant difference in the osseointegration of the implant in the post-extraction lenok and in the mature bone. There was no statistically significant difference in the percentage of bone connection between test and control implants placed in different jaws. Connective tissue in implants is absent, as well as fibrous. Bone destruction was not observed in histological sections.Conclusions: jsseointegration and survival of dental implants without orthopedic load, installed without the use of osteoplastic materials in a fresh post-extraction hole and in a mature bone is almost the same, regardless of the place of installation (upper or lower jaw).

  • Stability of short and long dental implants placed at different levels

    by R. V. Studenikin, A. A. Mamedov

    Purpose. The purpose of the study was to evaluate the stability during healing and before loading of implants placed at different levels depending on the texture of their neck.Materials and methods. The study included patients with the same type of bone (type II), who were implanted with screw implants with a conical connection: – parallel walls (polished collar – 0.3 mm), installed at the level of the alveolar ridge without immersion (group A); – root-shaped with micro-thread in the collar area, set below the level of the alveolar ridge by 1 mm (group B); – root-shaped (polished collar – 0.75 mm), installed above the level of the alveolar ridge by 1 mm (group B).All implants were used with shapers. The values of the implant stability coefficient (ISQ) were determined using resonance frequency analysis immediately after implant placement during surgery and 1, 4, 8 and 12 weeks after it. Other evaluated stability factors are the diameter and length of the implant, the place of their installation (upper or lower jaw).Results. A total of 60 implants were evaluated (20 in each group). Mean ISQ values at baseline on the day of surgery and 1 week after insertion were significantly higher in group B (p=0.006, p=0.022 and p=0.031, respectively, for groups B, C, A). There were no differences at subsequent observation points. The ISQ value was higher for wide (diameter – 4.3 mm) implants than with a smaller diameter value (3.5 mm) and for mandibular implants than for maxillary implants at all points of observation. Neglecting the diameter data, the length of the implant did not affect the ISQ values.Conclusion. Inserting the implant deeper into the bone may only matter for primary stability. Moreover, the diameter of the implant and its location affect the primary and secondary stability before loading, while the length of the implant does not play an important role if the diameter is not taken into account.


  • The full cycle of digitalization and automation in dental practice

    by R.V. Studenikin, A.A. Mamedov

    According to the literature, was made overview of the current state of development of CAD/CAM technology: the optical and mechanical scanners used, software, methods of implementing production technology, milling devices, materials used, features of dental preparation. The technology of full digitalization of dental restoration proposed by the authors is described in detail including all stages from computer-aided design to the production of dentures. The technique has been tested on 20 patients. The conclusions note the competitive advantages of the technology used and its existing disadvantages.


  • Comparison of digital scanning and conventional impression taking for implant-supported prostheses

    by R. V. Studenikin, A. A. Mamedov

    The effect of discrepancies between digital scans and conventional impressions on the clinical performance of a permanent restoration has not been fully understood.Thirty patients received conventional impressions and digital scans of a single implant restoration. Two crowns were made for the same implant using both methods. The time taken for each procedure was recorded. After analyzing the accuracy and effectiveness of both crowns, the best one was placed. A questionnaire was conducted to assess the preferences and comfort when using crowns made by one method or another.The total time for the traditional impression technique was 15 minutes, while the time for the digital scanning technique was significantly less – 10 minutes.The preparation time, including the disinfection of the silicone impressions, their transportation to the laboratory, the casting of the impressions, the hardening of the plaster, as well as the preparation of the model by the technician, was 4 hours for conventional impressions.The timing for sending the STL file and modeling the structure was less than 2 hours for the digital scan method. The production time of crowns takes 3 hours for both conventional impressions and digital ones.Of all crowns selected for placement, 46.7% were made from conventional impressions and 53.3% from digital scans. Participants preferred the digital scanning technique (89%) over the traditional impression-taking technique (11%).The data from this study suggest that digital scanning and CAD/CAM technology may be more effective and better accepted by study par-ticipants for a single implant restoration than conventional impressions and plaster casts.

  • Open Access

    Fabrication and Use of a Customized Provisional Composite Abutment in Dental Practice

    by Roman Studenikin, Sabukhi Niftaliev

    Introduction. Reducing the time of implant integration and the period of prosthetics is an important task of dentistry since this leads to improved quality of life and successful rehabilitation of the patient. Therefore, currently, there is an intensely increased interest in immediate or early loading of the implant, when certain parameters of primary implant stability in the bone tissue are achieved. Materials and Methods. The materials used to perform the procedure for placement of a customized provisional composite abutment were a provisional prefabricated abutment with a retention grip for the composite; aluminum oxide powder with a particle size of 27 mu m for better adhesion of the composite, with which the retention grip of the provisional abutment is coated; 3M Single Bond Universal light-curing adhesive applied to the provisional abutment; and Filtek Bulk Fill 3M composite including a low-viscosity radiopaque nanocomponent and ytterbium trifluoride filler with a particle size of 0.01-3.5 nm. Methods used in this study were as follows: fabrication technique using the Cervico system for a customized provisional composite abutment; sandblasting of the provisional abutment using the apparatus RONDOFLEX (KERR); light polymerization of low-viscosity composite using Demi Ultra Kerr lamp (luminous flux power not less than 1100 mW/cm(2)); and radiographic control of the abutment fit in the implant. Results. The surgical and orthopedic treatment of 20 patients was performed using this technique. The control group consisted of 11 patients with similar pathology, in whose surgery the fabrication of a provisional prosthesis was used. As a result, it was possible to form a gingival profile, in comparison with the control group, to accelerate mucogingival and bone integration, as well as to quickly carry out orthopedic rehabilitation of the patient. The average value of the time required for the final formation of soft tissues for prosthetics in patients in the experimental group was significantly lower than those in the comparison group (p=0.007 and p=0.028, respectively). In most clinical cases, there is no need for surgery on soft tissues, which eliminates the possibility of additional traumas. Conclusions. The use of a promising technology for the fabrication of a crown on the implant and a customized provisional composite abutment significantly reduced the period of orthopedic rehabilitation of the patient. Immediate implantation with a customized provisional composite abutment completely forms the gingival profile, reduces the risk of microbial contamination in the area of bone formation, minimizes soft tissue ischemia, and accelerates the processes of mucogingival and bone integration around the implant.


  • Open Access

    Prosthodontics Using Removable Platform Switching Technologies (Multiunit, On1) as Exemplified by Conical Connection Implant Systems for Early and Immediate Loading

    by Roman Studenikin

    The removable platform switching technology (multiunit, On1) was tested intraoperatively using the passive placement technique as exemplified by a conical connection implant system, which makes it possible to visually control the placement of these platforms with respect to the alveolar bone in the correct orthopedic position. The technology is characterized by a rapid epithelialization of tissues around the base platform until the final integration of the implant, minimal trauma in the emergence profile zone, and an improved minimally invasive orthopedic protocol for working on a removable platform switching base.