Dmitriy I. Polyakov
Research Subjects
Dmitriy I. Polyakov has a total of 33 co-authors. Here are the top co-authors by number of shared publications:
- Sergey A. Muslov
Russian University of Medicine of the Ministry of Health of the Russian Federation
5 shared publications - Sergey Darchoevich Arutyunov
Federal State Budgetary Educational Institution of Higher Education «Russian University of Medicine» of the Ministry of Health of Russia
4 shared publications - Alexander Gennadievich Stepanov
RUDN University
2 shared publications - Anton A. Pivovarov
Russian University of Medicine
2 shared publications - Kamalutdin Gadzhievich Akhmedov
Russian University of Medicine
2 shared publications - Nataliia V. Zaitseva
Russian University of Medicine
2 shared publications
Latest Publications
- 4 July 2026
- Published by Clinical Dentistry in Clinical Dentistry (Russia)
- Vol. 29 (2) , 86-92
Clinical, technological and economic justification of reinforcement with skeletal bases of complete removable dentures
The scientific article develops an algorithm for the interaction of manufacturers and consumers of frames reinforcing the bases of complete removable dentures in the large-scale healthcare system of the Russian Federation and dental practice, provides a clinical, technological and economic justification for strengthening such prosthetic structures with mesh frames of various production technologies according to the following criteria: clinical and economic, this refers to a decrease in the number of visits to the dental clinic by patients with complete loss of teeth during prosthetics with complete removable dentures (CRD) with a mesh-frame reinforced base of various production technologies; economic and technological — an increase in the profitability of the sale of CRD with a reinforced base, and a quotient of dividing its service life by a multiplier of the increase in the cost of such a prosthetic structure; socio-economic, estimated by a reduction in public health losses due to breakdowns of prosthetic bases and a reduction in forced downtime associated with patient visits to dentists, when reinforced with frames of various technologies for the production of CRD bases, and thereby the clinic’s profits for unpaid patient work on the reconstruction of CRD damage (warranty case). The results obtained showed that the use of factory-made metal mesh frames for reinforcing the bases of artificial teeth makes it possible to reduce public health losses annually due to breakdowns of prosthetic bases and reduce downtime associated with dental visits by patients by 2.2 billion rubles, factory-made quartz mesh frames reduce public health losses by 1.1 bn rubles per year, and personalized polymer reinforcing perforated frames, individually manufactured using digital 3D printing technology, annually reduce public health losses by 4.4 bn rubles. Printed polymer frames have an advantage over factory-made reinforcing metal mesh frames according to the criteria: clinical and economic — 2 times; economic and technological — 1.5 times; socio-economic — by 2 times, they also have an advantage over quartz mesh frames according to the criteria: clinico-economic — by 3.88 times; economic and technological — by 12.92 times; socio-economic — by 4 times. The multiplicative coefficient of synergy for metal mesh frames is 4.7 bn rubles, for quartz mesh frames it is 0.14 bn rubles, and for polymer printed frames it is 28.1 bn rubles. In other words, the multiplicative coefficient of synergy for a printed polymer frame has an advantage of 6.04 times over a similar indicator for a metal mesh frame, and 200.63 times for a quartz mesh frame, which proves the advantage of printed polymer reinforcing frames.
- 4 July 2026
- Published by Clinical Dentistry in Clinical Dentistry (Russia)
- Vol. 29 (2) , 86-92
Clinical, technological and economic justification of reinforcement with skeletal bases of complete removable dentures
The scientific article develops an algorithm for the interaction of manufacturers and consumers of frames reinforcing the bases of complete removable dentures in the large-scale healthcare system of the Russian Federation and dental practice, provides a clinical, technological and economic justification for strengthening such prosthetic structures with mesh frames of various production technologies according to the following criteria: clinical and economic, this refers to a decrease in the number of visits to the dental clinic by patients with complete loss of teeth during prosthetics with complete removable dentures (CRD) with a mesh-frame reinforced base of various production technologies; economic and technological — an increase in the profitability of the sale of CRD with a reinforced base, and a quotient of dividing its service life by a multiplier of the increase in the cost of such a prosthetic structure; socio-economic, estimated by a reduction in public health losses due to breakdowns of prosthetic bases and a reduction in forced downtime associated with patient visits to dentists, when reinforced with frames of various technologies for the production of CRD bases, and thereby the clinic’s profits for unpaid patient work on the reconstruction of CRD damage (warranty case). The results obtained showed that the use of factory-made metal mesh frames for reinforcing the bases of artificial teeth makes it possible to reduce public health losses annually due to breakdowns of prosthetic bases and reduce downtime associated with dental visits by patients by 2.2 billion rubles, factory-made quartz mesh frames reduce public health losses by 1.1 bn rubles per year, and personalized polymer reinforcing perforated frames, individually manufactured using digital 3D printing technology, annually reduce public health losses by 4.4 bn rubles. Printed polymer frames have an advantage over factory-made reinforcing metal mesh frames according to the criteria: clinical and economic — 2 times; economic and technological — 1.5 times; socio-economic — by 2 times, they also have an advantage over quartz mesh frames according to the criteria: clinico-economic — by 3.88 times; economic and technological — by 12.92 times; socio-economic — by 4 times. The multiplicative coefficient of synergy for metal mesh frames is 4.7 bn rubles, for quartz mesh frames it is 0.14 bn rubles, and for polymer printed frames it is 28.1 bn rubles. In other words, the multiplicative coefficient of synergy for a printed polymer frame has an advantage of 6.04 times over a similar indicator for a metal mesh frame, and 200.63 times for a quartz mesh frame, which proves the advantage of printed polymer reinforcing frames.
- Open Access
- 30 March 2026
- Published by ECO-Vector LLC (Publications) in Medical academic journal
- Vol. 26 (1) , 81-90
Comparison of deformation models of the tympanic membrane
BACKGROUND: The development of methods for assessing the conformity of the physical properties of artificial materials with the physiological parameters of native tissues and organs is one of the pressing tasks of tissue engineering. This also applies to artificial wound dressings used in tympanoplasty operations. AIM: To determine a group of deformation models of the human eardrum for the purpose of screening artificial materials for surgical replacement of its defects. METHODS: Formally defined deformation models were considered: elastic linear, bilinear, trilinear, exponential, and hyperelastic models. Among the hyperelastic models, the neo-Hookean, 2-parameter Mooney–Rivlin, 1st-order Ogden, 3rd-order Yeoh, 2nd-order polynomial, and Veronda–Westmann model were analyzed. The agreement between the calculated deformation data and experimental data was assessed using descriptive statistics. The Mathcad 15.0 and ANSYS 2022 R2 software packages were used for the calculations. RESULTS: The numerical values of the parameters of the linear, bilinear, trilinear, exponential, and hyperelastic family models were determined. Of the studied hyperelastic models, the polynomial model demonstrated the lowest mean square approximation error (SD = 0.002 MPa); the highest correlation between experimental and model data was demonstrated by the polynomial, Ogden, and Yeoh models (r = 0.9999). CONCLUSION: The polynomial model is the most preferable for describing the mechanical properties of such a biological object as the eardrum, which experiences various deformation modes, and can be used for screening artificial materials for replacing defects in tympanic membrane grafting. Among other models, the smallest discrepancy between model and experimental data was found for the exponential model (SD = 0.002 MPa, r = 0.9998). The obtained data may be useful in the field of regenerative medicine and tissue engineering in the search for replacement materials for reconstructive interventions on the middle ear.
- 30 March 2026
- Published by ECO-Vector LLC (Publications) in Medical academic journal
- Vol. 26 (1) , 81-90
Open AccessComparison of deformation models of the tympanic membrane
BACKGROUND: The development of methods for assessing the conformity of the physical properties of artificial materials with the physiological parameters of native tissues and organs is one of the pressing tasks of tissue engineering. This also applies to artificial wound dressings used in tympanoplasty operations. AIM: To determine a group of deformation models of the human eardrum for the purpose of screening artificial materials for surgical replacement of its defects. METHODS: Formally defined deformation models were considered: elastic linear, bilinear, trilinear, exponential, and hyperelastic models. Among the hyperelastic models, the neo-Hookean, 2-parameter Mooney–Rivlin, 1st-order Ogden, 3rd-order Yeoh, 2nd-order polynomial, and Veronda–Westmann model were analyzed. The agreement between the calculated deformation data and experimental data was assessed using descriptive statistics. The Mathcad 15.0 and ANSYS 2022 R2 software packages were used for the calculations. RESULTS: The numerical values of the parameters of the linear, bilinear, trilinear, exponential, and hyperelastic family models were determined. Of the studied hyperelastic models, the polynomial model demonstrated the lowest mean square approximation error (SD = 0.002 MPa); the highest correlation between experimental and model data was demonstrated by the polynomial, Ogden, and Yeoh models (r = 0.9999). CONCLUSION: The polynomial model is the most preferable for describing the mechanical properties of such a biological object as the eardrum, which experiences various deformation modes, and can be used for screening artificial materials for replacing defects in tympanic membrane grafting. Among other models, the smallest discrepancy between model and experimental data was found for the exponential model (SD = 0.002 MPa, r = 0.9998). The obtained data may be useful in the field of regenerative medicine and tissue engineering in the search for replacement materials for reconstructive interventions on the middle ear.
- 1 January 2026
- Published by LLC Polyforum Group in Russian Otorhinolaryngology
- Vol. 25 (1)
Application of theory of latent variables to assess the quality of life of patients with auricular epithesis
Prosthetic reconstruction of patients with microtia and post-traumatic loss of the auricle of various origins silicone using epithesis is accepted by the professional community of doctors as an alternative method of surgical plastic surgery. Modern epitheses of the auricle are modeled in a CAD system based on a scan of the preserved contralateral natural auricle, the virtual mirror image of which is adapted in a computer modeling program to the prosthetic bed. According to the created virtual model of the auricle, a personalized design of the mold (cuvette) of the auricle ectoprosthesis is modeled, which is made of a heat-resistant polymer using additive printing technology. Objective. To develop a methodology for assessing the quality of life for patients who have undergone the procedure of prosthetic reconstruction of the missing auricle, which is based on the Rasch model of estimating latent variables, which will make it possible to obtain an integral assessment of the quality of life on a linear scale independent of the number of patients and a set of questionnaire questions. Results. The author suggests a direction for obtaining objective assessments based on subjective criteria of patients who have received auricular prosthetics, which is associated with a model for processing private assessments of quality of life when receiving a final assessment. It is based on a new but intensively developing model of objective measurements, which is based on the theory of latent variables.
- 1 January 2026
- Published by LLC Polyforum Group in Russian Otorhinolaryngology
- Vol. 25 (1)
Application of theory of latent variables to assess the quality of life of patients with auricular epithesis
Prosthetic reconstruction of patients with microtia and post-traumatic loss of the auricle of various origins silicone using epithesis is accepted by the professional community of doctors as an alternative method of surgical plastic surgery. Modern epitheses of the auricle are modeled in a CAD system based on a scan of the preserved contralateral natural auricle, the virtual mirror image of which is adapted in a computer modeling program to the prosthetic bed. According to the created virtual model of the auricle, a personalized design of the mold (cuvette) of the auricle ectoprosthesis is modeled, which is made of a heat-resistant polymer using additive printing technology. Objective. To develop a methodology for assessing the quality of life for patients who have undergone the procedure of prosthetic reconstruction of the missing auricle, which is based on the Rasch model of estimating latent variables, which will make it possible to obtain an integral assessment of the quality of life on a linear scale independent of the number of patients and a set of questionnaire questions. Results. The author suggests a direction for obtaining objective assessments based on subjective criteria of patients who have received auricular prosthetics, which is associated with a model for processing private assessments of quality of life when receiving a final assessment. It is based on a new but intensively developing model of objective measurements, which is based on the theory of latent variables.
- 18 December 2025
- Published by Clinical Dentistry in Clinical Dentistry (Russia)
- Vol. 28 (4) , 174-180
Adhesion of oral microbiota representatives to polymethylmethacrylate samples with a polyetheretherketone framework: an in vitro study
Fracture of complete removable denture (CRD) bases is common in contemporary prosthodontic practice. High-strength polymer reinforcing meshes, particularly polyether-ether-ketone (PEEK), may serve as an alternative because they can chemically bond to PMMA and increase structural durability. In addition, the base composition can influence microbial adhesion—an important factor for preventing biodeterioration and infectious complications. Objectives — evaluate the effect of integrating a PEEK framework into the denture-base structure on adhesion of marker oral microorganisms, taking into account their specific interactions with composite materials. Materials and methods. Compared monolithic PMMA specimens (heat- and cold-cured), monolithic PEEK, and two PMMA+PEEK composites with a perforated ring-type framework and stoppers of different heights (0.5 mm on both sides; 1.0 mm on one side) (n=5 per group). Test strains: Streptococcus sanguinis, Porphyromonas gingivalis, Staphylococcus aureus, Candida albicans. The adhesion index (Ia) was defined as the fraction of cells retained after standardized inoculation and washing. Significance threshold: α=0.05. Results. On PMMA, bacterial Ia values were 0.54—0.70 (“substantial”), while C. albicans reached 0.74—0.75 (“high”). Relative to PMMA, PEEK showed lower Ia for Str. sanguinis (0.55 vs 0.69—0.70), P. gingivalis (0.34 vs 0.54), and C. albicans (0.59 vs 0.74—0.75) (all p0.05). PMMA+PEEK composites showed lower Ia than PMMA for P. gingivalis (0.47—0.49 vs 0.54; p<0.05) and numerically lower values for Str. sanguinis (0.55—0.58 vs 0.69—0.70) and C. albicans (0.65—0.68 vs 0.74—0.75); for S. aureus differences were not significant (0.65—0.66 vs 0.67—0.69). Conclusions. Embedding a perforated PEEK framework in PMMA reduces adhesion of P. gingivalis and tends to reduce adhesion of Str. sanguinis and C. albicans, without affecting S. aureus. These findings support the bioinert properties of PEEK and its potential to limit microbial contamination of denture bases.
- 18 December 2025
- Published by Clinical Dentistry in Clinical Dentistry (Russia)
- Vol. 28 (4) , 174-180
Adhesion of oral microbiota representatives to polymethylmethacrylate samples with a polyetheretherketone framework: an in vitro study
Fracture of complete removable denture (CRD) bases is common in contemporary prosthodontic practice. High-strength polymer reinforcing meshes, particularly polyether-ether-ketone (PEEK), may serve as an alternative because they can chemically bond to PMMA and increase structural durability. In addition, the base composition can influence microbial adhesion—an important factor for preventing biodeterioration and infectious complications. Objectives — evaluate the effect of integrating a PEEK framework into the denture-base structure on adhesion of marker oral microorganisms, taking into account their specific interactions with composite materials. Materials and methods. Compared monolithic PMMA specimens (heat- and cold-cured), monolithic PEEK, and two PMMA+PEEK composites with a perforated ring-type framework and stoppers of different heights (0.5 mm on both sides; 1.0 mm on one side) (n=5 per group). Test strains: Streptococcus sanguinis, Porphyromonas gingivalis, Staphylococcus aureus, Candida albicans. The adhesion index (Ia) was defined as the fraction of cells retained after standardized inoculation and washing. Significance threshold: α=0.05. Results. On PMMA, bacterial Ia values were 0.54—0.70 (“substantial”), while C. albicans reached 0.74—0.75 (“high”). Relative to PMMA, PEEK showed lower Ia for Str. sanguinis (0.55 vs 0.69—0.70), P. gingivalis (0.34 vs 0.54), and C. albicans (0.59 vs 0.74—0.75) (all p0.05). PMMA+PEEK composites showed lower Ia than PMMA for P. gingivalis (0.47—0.49 vs 0.54; p<0.05) and numerically lower values for Str. sanguinis (0.55—0.58 vs 0.69—0.70) and C. albicans (0.65—0.68 vs 0.74—0.75); for S. aureus differences were not significant (0.65—0.66 vs 0.67—0.69). Conclusions. Embedding a perforated PEEK framework in PMMA reduces adhesion of P. gingivalis and tends to reduce adhesion of Str. sanguinis and C. albicans, without affecting S. aureus. These findings support the bioinert properties of PEEK and its potential to limit microbial contamination of denture bases.
- 21 June 2023
- Published by Media Sphere Publishing Group in Russian Journal of Stomatology
- Vol. 16 (2)
Key features of anaplastology of auricle for craniofacial microsomia
Congenital microtia (partial and total absence of auricle) are symptoms of craniofacial microsomia syndrome. One of the methods for restoring of auricle is anaplastology based on extraoral implants. Purpose of the study is to determine the key features of planning and anaplastology of the auricle in craniofacial mircosomia. Material and methods. The results of examination and treatment wereanalyzed. 111 children with craniofacial microsomia syndrome aged 0—18 years were identified from 2011 to 2022, 40 of examined persons (36%) underwent MSCT. For 12 patients the study was conducted 2 or more times. In the standard software the dimensions of the auricles were measured, as well as the thickness of the temporal bone corresponding the location of the auricle on the healthy side and the ear area on the affected side. Results. Regardless of the age and side of the lesion, even considering the sclerotic type of the structure of the temporal bone on the affected side, its thickness in patients with craniofacial microsomia in front of the pyramid is in most cases insufficient for implantation. The most optimal would-be implantation in the mastoid process, however, the safest area for trepanation and formation of the implant bed is the trepanation triangle. Conclusions. In patients with craniofacial microsomia, structural features of the temporal bone are determined: deformation and thinning of the scales, dystopia of the facial nerve canal, hypoplasia of the auditory ossicles and cochlea, sclerosis of the cells of the mastoid process. These nuances must be considered when planning both aesthetic and functional restoration of the external and middle ear. MSCT is the method of choice in the examination of this group of patients, without which the planning of surgical treatment is not possible.
- 21 June 2023
- Published by Media Sphere Publishing Group in Russian Journal of Stomatology
- Vol. 16 (2)
Key features of anaplastology of auricle for craniofacial microsomia
Congenital microtia (partial and total absence of auricle) are symptoms of craniofacial microsomia syndrome. One of the methods for restoring of auricle is anaplastology based on extraoral implants. Purpose of the study is to determine the key features of planning and anaplastology of the auricle in craniofacial mircosomia. Material and methods. The results of examination and treatment wereanalyzed. 111 children with craniofacial microsomia syndrome aged 0—18 years were identified from 2011 to 2022, 40 of examined persons (36%) underwent MSCT. For 12 patients the study was conducted 2 or more times. In the standard software the dimensions of the auricles were measured, as well as the thickness of the temporal bone corresponding the location of the auricle on the healthy side and the ear area on the affected side. Results. Regardless of the age and side of the lesion, even considering the sclerotic type of the structure of the temporal bone on the affected side, its thickness in patients with craniofacial microsomia in front of the pyramid is in most cases insufficient for implantation. The most optimal would-be implantation in the mastoid process, however, the safest area for trepanation and formation of the implant bed is the trepanation triangle. Conclusions. In patients with craniofacial microsomia, structural features of the temporal bone are determined: deformation and thinning of the scales, dystopia of the facial nerve canal, hypoplasia of the auditory ossicles and cochlea, sclerosis of the cells of the mastoid process. These nuances must be considered when planning both aesthetic and functional restoration of the external and middle ear. MSCT is the method of choice in the examination of this group of patients, without which the planning of surgical treatment is not possible.
- 20 January 2022
- Published by Periodontal Association - RPA in Parodontologiya
- Vol. 26 (4) , 327-333
Clinical and microbiological aspects of the auricle prosthetic reconstruction
Relevance. Plastic and reconstructive surgery of the missing outer ear is not always successful and may cause complications. Prosthetic reconstruction using silicone ectoprostheses (epitheses) is an alternative solution to this problem. Purpose – the study aimed to verify clinical and microbiological protocol of prosthetic rehabilitation of patients with a missing auricle using temporary silicone epitheses during implant osseointegration placed for the final magnet-bar retention system and assessment of the prosthetic reconstruction effe ctiveness.Materials and methods. The study compared and analyzed the quality of life and microbial colonization of the skin biotope in the main group patients – with temporary silicone auricle epithesis during extraoral implant osseointegration and in the control group without such prostheses. Quality of life was assessed before and after treatment using the automated questionnaires (WHOQOL-BREF and QL PAER) developed by us for mobile devices. We determined the quantitative and qualitative composition of the skin microbiota behind the ear in all patients with fixed silicone samples for seven days.Results. According to all domains of the "WHOQOL-BREF" and "QL PAER" questionnaires, an integral index of QLI (p < 0.05) was reliably higher after prosthesis fixation in the main group. Skin biotope colonization by strains of resident microorganisms in the region of Technovent silicone epithesis increased if B-460 glue was applied, and the water-soluble G609 glue did not have a similar effect.Conclusion. A digital protocol for the manufacture of a temporary silicone epithesis of the auricle for the period of extraoral implant osseointegration, with the fixation on a water-soluble glue, improves the quality of life of patients with anotia and minimizes microbial colonization of the biotope of t he skin behind the ear.
- 20 January 2022
- Published by Periodontal Association - RPA in Parodontologiya
- Vol. 26 (4) , 327-333
Clinical and microbiological aspects of the auricle prosthetic reconstruction
Relevance. Plastic and reconstructive surgery of the missing outer ear is not always successful and may cause complications. Prosthetic reconstruction using silicone ectoprostheses (epitheses) is an alternative solution to this problem. Purpose – the study aimed to verify clinical and microbiological protocol of prosthetic rehabilitation of patients with a missing auricle using temporary silicone epitheses during implant osseointegration placed for the final magnet-bar retention system and assessment of the prosthetic reconstruction effe ctiveness.Materials and methods. The study compared and analyzed the quality of life and microbial colonization of the skin biotope in the main group patients – with temporary silicone auricle epithesis during extraoral implant osseointegration and in the control group without such prostheses. Quality of life was assessed before and after treatment using the automated questionnaires (WHOQOL-BREF and QL PAER) developed by us for mobile devices. We determined the quantitative and qualitative composition of the skin microbiota behind the ear in all patients with fixed silicone samples for seven days.Results. According to all domains of the "WHOQOL-BREF" and "QL PAER" questionnaires, an integral index of QLI (p < 0.05) was reliably higher after prosthesis fixation in the main group. Skin biotope colonization by strains of resident microorganisms in the region of Technovent silicone epithesis increased if B-460 glue was applied, and the water-soluble G609 glue did not have a similar effect.Conclusion. A digital protocol for the manufacture of a temporary silicone epithesis of the auricle for the period of extraoral implant osseointegration, with the fixation on a water-soluble glue, improves the quality of life of patients with anotia and minimizes microbial colonization of the biotope of t he skin behind the ear.
- 1 January 2021
- Published by Clinical Dentistry in Clinical Dentistry (Russia)
- No. 1,p. 160-164
Study of the quality of life of patients using the QL PAER specific questionnaire after prosthetic auricular reconstruction
- 1 January 2021
- Published by Clinical Dentistry in Clinical Dentistry (Russia)
- No. 1,p. 160-164
Study of the quality of life of patients using the QL PAER specific questionnaire after prosthetic auricular reconstruction
- Open Access
- 1 January 2020
- Published by Tomsk State University in Izvestiya vysshikh uchebnykh zavedenii. Fizika
- No. 9,p. 68-71
Measurement and calculation of the parameters of mechanical properties of silicone rubber
The measurement and calculation of the mechanical properties of silicone rubber used for the manufacture of a prosthesis for the auricle of patients based on dental CAD/CAM systems, using a hybrid technology that includes traditional and digital methods of manufacturing medical devices were performed. Mechanical tensile tests were carried out in a climatic chamber at various temperatures: -20; 0; 25; 40 °C. All mechanical characteristics of silicone rubber lay in a very limited range of values and monotonically decreased with increasing test temperature from -20 to + 45°C. At the same time, the elastic characteristics (elastic modulus) decreased by 1.55, deformation (fracture deformation) - by 1.98, strength (tensile strength) - by 2.37 times. The average values of tensile strength were 6.54 MPa, fracture deformation - 1480.61%, modulus of elasticity - 0.53 MPa, and temperature gradient: 0.08 MPa/deg, 14.8%/deg and 0.004 MPa/deg, respectively. In the framework of the Mooney - Rivlin hyperelastic model, the coefficients of the model C 01 and C 10 are determined, which can be used as parameters when performing simulation modeling of the stress-strain state of prostheses. Based on the data obtained, an assessment was made of the cross-linked density of the silicone rubber material as a synthetic polymer. It turned out to be equal to 0.49.
- 1 January 2020
- Published by Tomsk State University in Izvestiya vysshikh uchebnykh zavedenii. Fizika
- No. 9,p. 68-71
Open AccessMeasurement and calculation of the parameters of mechanical properties of silicone rubber
The measurement and calculation of the mechanical properties of silicone rubber used for the manufacture of a prosthesis for the auricle of patients based on dental CAD/CAM systems, using a hybrid technology that includes traditional and digital methods of manufacturing medical devices were performed. Mechanical tensile tests were carried out in a climatic chamber at various temperatures: -20; 0; 25; 40 °C. All mechanical characteristics of silicone rubber lay in a very limited range of values and monotonically decreased with increasing test temperature from -20 to + 45°C. At the same time, the elastic characteristics (elastic modulus) decreased by 1.55, deformation (fracture deformation) - by 1.98, strength (tensile strength) - by 2.37 times. The average values of tensile strength were 6.54 MPa, fracture deformation - 1480.61%, modulus of elasticity - 0.53 MPa, and temperature gradient: 0.08 MPa/deg, 14.8%/deg and 0.004 MPa/deg, respectively. In the framework of the Mooney - Rivlin hyperelastic model, the coefficients of the model C 01 and C 10 are determined, which can be used as parameters when performing simulation modeling of the stress-strain state of prostheses. Based on the data obtained, an assessment was made of the cross-linked density of the silicone rubber material as a synthetic polymer. It turned out to be equal to 0.49.