Irene Mendez Guerra
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Irene Mendez Guerra has a total of 21 co-authors. Here are the top co-authors by number of shared publications:
- Dario Farina
Department of Bioengineering, Imperial College London, London, UK
8 shared publications - Deren Yusuf Barsakcioglu
Imperial College London, London, United Kingdom of Great Britain and Northern Ireland
4 shared publications - Ivan Vujaklija
Department of Electrical Engineering and Automation, Aalto University, Espoo, Finland
3 shared publications - Jumpei Kashiwakura
Department of Bioengineering, Imperial College London, London, U.K
2 shared publications - Seyed Farokh Atashzar
Department of Electrical and Computer Engineering, New York University (NYU), USA
2 shared publications - Alexander Kenneth Clarke
Department of Bioengineering, Imperial College London, London, U.K.
1 shared publication
Latest Publications
- Open Access
- 29 July 2024
- Published by IOP Publishing in Journal of Neural Engineering
- Vol. 21 (4) , 046023
Adaptive EMG decomposition in dynamic conditions based on online learning metrics with tunable hyperparameters
Objective. Developing neural decoders robust to non-stationary conditions is essential to ensure their long-term accuracy and stability. This is particularly important when decoding the neural drive to muscles during dynamic contractions, which pose significant challenges for stationary decoders. Approach. We propose a novel adaptive electromyography (EMG) decomposition algorithm that builds on blind source separation methods by leveraging the Kullback–Leibler divergence and kurtosis of the signals as metrics for online learning. The proposed approach provides a theoretical framework to tune the adaptation hyperparameters and compensate for non-stationarities in the mixing matrix, such as due to dynamic contractions, and to identify the underlying motor neuron (MN) discharges. The adaptation is performed in real-time (∼22 ms of computational time per 100 ms batches). Main results. The hyperparameters of the proposed adaptation captured anatomical differences between recording locations (forearm vs wrist) and generalised across subjects. Once optimised, the proposed adaptation algorithm significantly improved all decomposition performance metrics with respect to the absence of adaptation in a wide range of motion of the wrist (80∘). The rate of agreement, sensitivity, and precision were ⩾ 90 % in ⩾ 80 % of the cases in both simulated and experimentally recorded data, according to a two-source validation approach. Significance. The findings demonstrate the suitability of the proposed online learning metrics and hyperparameter optimisation to compensate the induced modulation and accurately decode MN discharges in dynamic conditions. Moreover, the study proposes an experimental validation method for EMG decomposition in dynamic tasks.
- 29 July 2024
- Published by IOP Publishing in Journal of Neural Engineering
- Vol. 21 (4) , 046023
Open AccessAdaptive EMG decomposition in dynamic conditions based on online learning metrics with tunable hyperparameters
Objective. Developing neural decoders robust to non-stationary conditions is essential to ensure their long-term accuracy and stability. This is particularly important when decoding the neural drive to muscles during dynamic contractions, which pose significant challenges for stationary decoders. Approach. We propose a novel adaptive electromyography (EMG) decomposition algorithm that builds on blind source separation methods by leveraging the Kullback–Leibler divergence and kurtosis of the signals as metrics for online learning. The proposed approach provides a theoretical framework to tune the adaptation hyperparameters and compensate for non-stationarities in the mixing matrix, such as due to dynamic contractions, and to identify the underlying motor neuron (MN) discharges. The adaptation is performed in real-time (∼22 ms of computational time per 100 ms batches). Main results. The hyperparameters of the proposed adaptation captured anatomical differences between recording locations (forearm vs wrist) and generalised across subjects. Once optimised, the proposed adaptation algorithm significantly improved all decomposition performance metrics with respect to the absence of adaptation in a wide range of motion of the wrist (80∘). The rate of agreement, sensitivity, and precision were ⩾ 90 % in ⩾ 80 % of the cases in both simulated and experimentally recorded data, according to a two-source validation approach. Significance. The findings demonstrate the suitability of the proposed online learning metrics and hyperparameter optimisation to compensate the induced modulation and accurately decode MN discharges in dynamic conditions. Moreover, the study proposes an experimental validation method for EMG decomposition in dynamic tasks.
- Open Access
Wearable Neural Interfaces: Real-Time Identification of Motor Neuron Discharges in Dynamic Motor Tasks
Objective Robustness to non-stationary conditions is essential to develop stable and accurate wearable neural interfaces. Approach We propose a novel adaptive electromyography (EMG) decomposition algorithm that builds on blind source separation methods by leveraging the Kullback-Liebler divergence and kurtosis of the signals as metrics for online learning. The proposed approach provides a theoretical framework to tune the adaptation hyperparameters and compensate for non-stationarities in the mixing matrix, such as due to dynamic contractions, and to identify the underlying motor neuron (MN) discharges. The adaptation is performed in real-time (∼22 ms of computational time per 100-ms batches). Main results The proposed adaptation algorithm significantly improved all decomposition performance metrics with respect to the absence of adaptation in a wide range of motion of the wrist (80°). The rate of agreement, sensitivity, and precision were ≥ 90% in ≥ 80% of the cases in both simulated and experimentally recorded data, according to a two-source validation approach. Significance The findings demonstrate the feasibility of accurately decoding MN discharges in real-time during dynamic contractions from wearable systems mounted at the wrist and forearm. Moreover, the study proposes an experimental validation method for EMG decomposition in dynamic tasks.
Open AccessWearable Neural Interfaces: Real-Time Identification of Motor Neuron Discharges in Dynamic Motor Tasks
Objective Robustness to non-stationary conditions is essential to develop stable and accurate wearable neural interfaces. Approach We propose a novel adaptive electromyography (EMG) decomposition algorithm that builds on blind source separation methods by leveraging the Kullback-Liebler divergence and kurtosis of the signals as metrics for online learning. The proposed approach provides a theoretical framework to tune the adaptation hyperparameters and compensate for non-stationarities in the mixing matrix, such as due to dynamic contractions, and to identify the underlying motor neuron (MN) discharges. The adaptation is performed in real-time (∼22 ms of computational time per 100-ms batches). Main results The proposed adaptation algorithm significantly improved all decomposition performance metrics with respect to the absence of adaptation in a wide range of motion of the wrist (80°). The rate of agreement, sensitivity, and precision were ≥ 90% in ≥ 80% of the cases in both simulated and experimentally recorded data, according to a two-source validation approach. Significance The findings demonstrate the feasibility of accurately decoding MN discharges in real-time during dynamic contractions from wearable systems mounted at the wrist and forearm. Moreover, the study proposes an experimental validation method for EMG decomposition in dynamic tasks.
- 31 August 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Robotics and Bionics
- Vol. 5 (4) , 1067-1081
Task-Oriented Design of a Multi-Degree of Freedom Upper Limb Prosthesis With Integrated Myocontrol and Sensory Feedback
Despite the progresses in upper limb prosthetic technologies of the past decades, there is still a large gap between the user needs and the available devices. Here, we describe the design and validation of a fully integrated, multi-degree of freedom upper limb prosthetic system designed on the basis of user survey studies. The system has five degrees of actuation, a combination of direct and under-actuated activation to produce the grasping/pinching force to perform activities of daily living, an active wrist, a closed-loop tactile biofeedback system, and simultaneous/proportional myoelectric control. The aforementioned features have been successfully integrated into a standalone prosthetic system. The system has been tested for its capacity to reproduce the human grasp when manipulating objects common in daily living. Moreover, the system underwent standardized clinical tests, showing a significant decrease in both shoulder and trunk compensatory movements with respect to a state-of-the-art commercial prosthesis.
- 31 August 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Robotics and Bionics
- Vol. 5 (4) , 1067-1081
Task-Oriented Design of a Multi-Degree of Freedom Upper Limb Prosthesis With Integrated Myocontrol and Sensory Feedback
Despite the progresses in upper limb prosthetic technologies of the past decades, there is still a large gap between the user needs and the available devices. Here, we describe the design and validation of a fully integrated, multi-degree of freedom upper limb prosthetic system designed on the basis of user survey studies. The system has five degrees of actuation, a combination of direct and under-actuated activation to produce the grasping/pinching force to perform activities of daily living, an active wrist, a closed-loop tactile biofeedback system, and simultaneous/proportional myoelectric control. The aforementioned features have been successfully integrated into a standalone prosthetic system. The system has been tested for its capacity to reproduce the human grasp when manipulating objects common in daily living. Moreover, the system underwent standardized clinical tests, showing a significant decrease in both shoulder and trunk compensatory movements with respect to a state-of-the-art commercial prosthesis.
- Open Access
- 14 August 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in TechRxiv
Task-oriented design of a multi-degree of freedom upper limb prosthesis with integrated myocontrol and sensory feedback
Despite the progresses in upper limb prosthetic technologies of the past decades, there is still a large gap between the user needs and the available devices. Here, we describe the design and validation of a fully integrated, multi-degree of freedom upper limb prosthetic system designed on the basis of user survey studies. The system has five degrees of freedom, sufficient grasping/pinching force achieved by a combination of direct and underactuated activation to perform activities of daily living, an active wrist, a closed-loop tactile biofeedback system, and simultaneous/proportional myoelectric control. The aforementioned components have been successfully integrated into a standalone prosthetic system. The system has been tested for its capacity to reproduce the human grasp when applied to objects common in daily living. Moreover, we tested the system in standardized clinical tests that showed a reduction of shoulder and trunk compensatory movements with respect to a state-of- the-art commercial prosthesis.
- 14 August 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in TechRxiv
Open AccessTask-oriented design of a multi-degree of freedom upper limb prosthesis with integrated myocontrol and sensory feedback
Despite the progresses in upper limb prosthetic technologies of the past decades, there is still a large gap between the user needs and the available devices. Here, we describe the design and validation of a fully integrated, multi-degree of freedom upper limb prosthetic system designed on the basis of user survey studies. The system has five degrees of freedom, sufficient grasping/pinching force achieved by a combination of direct and underactuated activation to perform activities of daily living, an active wrist, a closed-loop tactile biofeedback system, and simultaneous/proportional myoelectric control. The aforementioned components have been successfully integrated into a standalone prosthetic system. The system has been tested for its capacity to reproduce the human grasp when applied to objects common in daily living. Moreover, we tested the system in standardized clinical tests that showed a reduction of shoulder and trunk compensatory movements with respect to a state-of- the-art commercial prosthesis.
- Open Access
- 23 March 2023
- Published by Springer Nature in Nature Communications
- Vol. 14 (1) , 1-15
A myoelectric digital twin for fast and realistic modelling in deep learning
Muscle electrophysiology has emerged as a powerful tool to drive human machine interfaces, with many new recent applications outside the traditional clinical domains, such as robotics and virtual reality. However, more sophisticated, functional, and robust decoding algorithms are required to meet the fine control requirements of these applications. Deep learning has shown high potential in meeting these demands, but requires a large amount of high-quality annotated data, which is expensive and time-consuming to acquire. Data augmentation using simulations, a strategy applied in other deep learning applications, has never been attempted in electromyography due to the absence of computationally efficient models. We introduce a concept of Myoelectric Digital Twin - highly realistic and fast computational model tailored for the training of deep learning algorithms. It enables simulation of arbitrary large and perfectly annotated datasets of realistic electromyography signals, allowing new approaches to muscular signal decoding, accelerating the development of human-machine interfaces.
- 23 March 2023
- Published by Springer Nature in Nature Communications
- Vol. 14 (1) , 1-15
Open AccessA myoelectric digital twin for fast and realistic modelling in deep learning
Muscle electrophysiology has emerged as a powerful tool to drive human machine interfaces, with many new recent applications outside the traditional clinical domains, such as robotics and virtual reality. However, more sophisticated, functional, and robust decoding algorithms are required to meet the fine control requirements of these applications. Deep learning has shown high potential in meeting these demands, but requires a large amount of high-quality annotated data, which is expensive and time-consuming to acquire. Data augmentation using simulations, a strategy applied in other deep learning applications, has never been attempted in electromyography due to the absence of computationally efficient models. We introduce a concept of Myoelectric Digital Twin - highly realistic and fast computational model tailored for the training of deep learning algorithms. It enables simulation of arbitrary large and perfectly annotated datasets of realistic electromyography signals, allowing new approaches to muscular signal decoding, accelerating the development of human-machine interfaces.
- Open Access
- 1 April 2022
- Published by IOP Publishing in Journal of Neural Engineering
- Vol. 19 (2) , 026031
Far-field electric potentials provide access to the output from the spinal cord from wrist-mounted sensors
Objective. Neural interfaces need to become more unobtrusive and socially acceptable to appeal to general consumers outside rehabilitation settings. Approach. We developed a non-invasive neural interface that provides access to spinal motor neuron activities from the wrist, which is the preferred location for a wearable. The interface decodes far-field potentials present at the tendon endings of the forearm muscles using blind source separation. First, we evaluated the reliability of the interface to detect motor neuron firings based on far-field potentials, and thereafter we used the decoded motor neuron activity for the prediction of finger contractions in offline and real-time conditions. Main results. The results showed that motor neuron activity decoded from the far-field potentials at the wrist accurately predicted individual and combined finger commands and therefore allowed for highly accurate real-time task classification. Significance. These findings demonstrate the feasibility of a non-invasive, neural interface at the wrist for precise real-time control based on the output of the spinal cord.
- 1 April 2022
- Published by IOP Publishing in Journal of Neural Engineering
- Vol. 19 (2) , 026031
Open AccessFar-field electric potentials provide access to the output from the spinal cord from wrist-mounted sensors
Objective. Neural interfaces need to become more unobtrusive and socially acceptable to appeal to general consumers outside rehabilitation settings. Approach. We developed a non-invasive neural interface that provides access to spinal motor neuron activities from the wrist, which is the preferred location for a wearable. The interface decodes far-field potentials present at the tendon endings of the forearm muscles using blind source separation. First, we evaluated the reliability of the interface to detect motor neuron firings based on far-field potentials, and thereafter we used the decoded motor neuron activity for the prediction of finger contractions in offline and real-time conditions. Main results. The results showed that motor neuron activity decoded from the far-field potentials at the wrist accurately predicted individual and combined finger commands and therefore allowed for highly accurate real-time task classification. Significance. These findings demonstrate the feasibility of a non-invasive, neural interface at the wrist for precise real-time control based on the output of the spinal cord.
- Open Access
- 14 February 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 69 (8) , 2581-2592
Co-Adaptive Control of Bionic Limbs via Unsupervised Adaptation of Muscle Synergies
Objective: In this work, we present a myoelectric interface that extracts natural motor synergies from multi-muscle signals and adapts in real-time with new user inputs. With this unsupervised adaptive myocontrol (UAM) system, optimal synergies for control are continuously co-adapted with changes in user motor control, or as a function of perturbed conditions via online non-negative matrix factorization guided by physiologically informed sparseness constraints in lieu of explicit data labelling. Methods: UAM was tested in a set of virtual target reaching tasks completed by able-bodied and amputee subjects. Tests were conducted under normative and electrode perturbed conditions to gauge control robustness with comparisons to non-adaptive and supervised adaptive myocontrol schemes. Furthermore, UAM was used to interface an amputee with a multi-functional powered hand prosthesis during standardized Clothespin Relocation Tests, also conducted in normative and perturbed conditions. Results: In virtual tests, UAM effectively mitigated performance degradation caused by electrode displacement, affording greater resilience over an existing supervised adaptive system for amputee subjects. Induced electrode shifts also had negligible effect on the real world control performance of UAM with consistent completion times (23.91 $\pm$ 1.33 s) achieved across Clothespin Relocation Tests in the normative and electrode perturbed conditions. Conclusion: UAM affords comparable robustness improvements to existing supervised adaptive myocontrol interfaces whilst providing additional practical advantages for clinical deployment. Significance: The proposed system uniquely incorporates neuromuscular control principles with unsupervised online learning methods and presents a working example of a freely co-adaptive bionic interface.
- 14 February 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 69 (8) , 2581-2592
Open AccessCo-Adaptive Control of Bionic Limbs via Unsupervised Adaptation of Muscle Synergies
Objective: In this work, we present a myoelectric interface that extracts natural motor synergies from multi-muscle signals and adapts in real-time with new user inputs. With this unsupervised adaptive myocontrol (UAM) system, optimal synergies for control are continuously co-adapted with changes in user motor control, or as a function of perturbed conditions via online non-negative matrix factorization guided by physiologically informed sparseness constraints in lieu of explicit data labelling. Methods: UAM was tested in a set of virtual target reaching tasks completed by able-bodied and amputee subjects. Tests were conducted under normative and electrode perturbed conditions to gauge control robustness with comparisons to non-adaptive and supervised adaptive myocontrol schemes. Furthermore, UAM was used to interface an amputee with a multi-functional powered hand prosthesis during standardized Clothespin Relocation Tests, also conducted in normative and perturbed conditions. Results: In virtual tests, UAM effectively mitigated performance degradation caused by electrode displacement, affording greater resilience over an existing supervised adaptive system for amputee subjects. Induced electrode shifts also had negligible effect on the real world control performance of UAM with consistent completion times (23.91 $\pm$ 1.33 s) achieved across Clothespin Relocation Tests in the normative and electrode perturbed conditions. Conclusion: UAM affords comparable robustness improvements to existing supervised adaptive myocontrol interfaces whilst providing additional practical advantages for clinical deployment. Significance: The proposed system uniquely incorporates neuromuscular control principles with unsupervised online learning methods and presents a working example of a freely co-adaptive bionic interface.
- Open Access
Non-invasive real-time access to the output of the spinal cord via a wrist wearable interface
Despite the promising features of neural interfaces, their trade-off between information transfer and invasiveness has limited translation and viability outside research settings. Here, we present a non-invasive neural interface that provides access to spinal motoneuron activities from a sensor band at the wrist. The interface decodes electric signals present at the tendon endings of the forearm muscles by using a model of signal generation and deconvolution. First, we evaluated the reliability of the interface to detect motoneuron firings, and thereafter we used the decoded neural activity for the prediction of finger movements in offline and real-time conditions. The results showed that motoneuron activity decoded from the wrist accurately predicted individual and combined finger commands and therefore allowed for highly accurate real-time control. These findings demonstrate the feasibility of a wearable, non-invasive, neural interface at the wrist for precise real-time control based on the output of the spinal cord.
Open AccessNon-invasive real-time access to the output of the spinal cord via a wrist wearable interface
Despite the promising features of neural interfaces, their trade-off between information transfer and invasiveness has limited translation and viability outside research settings. Here, we present a non-invasive neural interface that provides access to spinal motoneuron activities from a sensor band at the wrist. The interface decodes electric signals present at the tendon endings of the forearm muscles by using a model of signal generation and deconvolution. First, we evaluated the reliability of the interface to detect motoneuron firings, and thereafter we used the decoded neural activity for the prediction of finger movements in offline and real-time conditions. The results showed that motoneuron activity decoded from the wrist accurately predicted individual and combined finger commands and therefore allowed for highly accurate real-time control. These findings demonstrate the feasibility of a wearable, non-invasive, neural interface at the wrist for precise real-time control based on the output of the spinal cord.
- Open Access
- 21 January 2019
- Published by IOP Publishing in Journal of Neural Engineering
- Vol. 16 (2) , 026003
On the robustness of real-time myoelectric control investigations: a multiday Fitts’ law approach
Objective . Real-time myoelectric experimental protocol is considered as a means to quantify usability of myoelectric control schemes. While usability should be considered over time to assure clinical robustness, all real-time studies reported thus far are limited to a single session or day and thus the influence of time on real-time performance is still unexplored. In this study, the aim was to develop a novel experimental protocol to quantify the effect of time on real-time performance measures over multiple days using a Fitts’ law approach. Approach . Four metrics: throughput, completion rate, path efficiency and overshoot, were assessed using three train-test strategies: (i) an artificial neural network (ANN) classifier was trained on data collected from the previous day and tested on present day (BDT) (ii) trained and tested on the same day (WDT) and (iii) trained on all previous days including present day and tested on present day (CDT) in a week-long experimental protocol. Main results . It was found that on average, the completion rate (98.37% ± 1.47%) of CDT was significantly better ( P < 0.01) than that of BDT (86.25% ± 3.46%) and WDT (94.22% ± 2.74%). The throughput (0.40 ± 0.03 bits s −1 ) of CDT was significantly better ( P = 0.001) than that of BDT (0.38 ± 0.03 bits s −1 ). Offline analysis showed a different trend due to the difference in the training strategies. Significance . Results suggest that increasing the size of the training set over time can be beneficial to assure robust performance of the system over time.
- 21 January 2019
- Published by IOP Publishing in Journal of Neural Engineering
- Vol. 16 (2) , 026003
Open AccessOn the robustness of real-time myoelectric control investigations: a multiday Fitts’ law approach
Objective . Real-time myoelectric experimental protocol is considered as a means to quantify usability of myoelectric control schemes. While usability should be considered over time to assure clinical robustness, all real-time studies reported thus far are limited to a single session or day and thus the influence of time on real-time performance is still unexplored. In this study, the aim was to develop a novel experimental protocol to quantify the effect of time on real-time performance measures over multiple days using a Fitts’ law approach. Approach . Four metrics: throughput, completion rate, path efficiency and overshoot, were assessed using three train-test strategies: (i) an artificial neural network (ANN) classifier was trained on data collected from the previous day and tested on present day (BDT) (ii) trained and tested on the same day (WDT) and (iii) trained on all previous days including present day and tested on present day (CDT) in a week-long experimental protocol. Main results . It was found that on average, the completion rate (98.37% ± 1.47%) of CDT was significantly better ( P < 0.01) than that of BDT (86.25% ± 3.46%) and WDT (94.22% ± 2.74%). The throughput (0.40 ± 0.03 bits s −1 ) of CDT was significantly better ( P = 0.001) than that of BDT (0.38 ± 0.03 bits s −1 ). Offline analysis showed a different trend due to the difference in the training strategies. Significance . Results suggest that increasing the size of the training set over time can be beneficial to assure robust performance of the system over time.