Masahide Yagi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Masahide Yagi has a total of 90 co-authors. Here are the top co-authors by number of shared publications:
- Noriaki Ichihashi
Human Health Sciences, Graduate School of Medicine, Kyoto University, Kyoto, Japan
34 shared publications - Masashi Taniguchi
Human Health Sciences, Graduate School of Medicine, Kyoto University, Kyoto, Japan
24 shared publications - Yoshihiro Fukumoto
Human Health Sciences, Graduate School of Medicine, Kyoto University, 53 Kawahara-cho, Shogoin, Sakyo-ku, Kyoto 606-8507, Japan; Faculty of Rehabilitation, Kansai Medical University, 18-89 Uyama Higashimachi, Hirakata, Osaka 573-1136, Japan
19 shared publications Noriaki Ichihashi
Human Health Sciences, Graduate School of Medicine, Kyoto University, 53 Shogoin Kawahara-cho, Sakyo-ku, Kyoto 606-8507, Japan; Faculty of Rehabilitation, Kansai Medical University, 18-89 Uyama-higashi, Hirakata, Osaka, 573-1136, Japan
14 shared publications- Shogo Okada
Human Health Sciences, Graduate School of Medicine, Kyoto University, Kyoto, Japan
13 shared publications - Jun Umehara
Faculty of Rehabilitation, Kansai Medical University, Hirakata, Osaka, Japan
11 shared publications
Latest Publications
- 5 November 2026
- Published by Wiley in Clinical Physiology and Functional Imaging
- Vol. 46 (6) , e70107
Higher intramuscular fat infiltration of the vastus medialis is associated with progression of femoral cartilage quality degeneration after 3 years
Purpose: This study aimed to determine whether the progression of medial femoral cartilage quality degeneration is associated with baseline measures of quadriceps muscle atrophy or intramuscular adipose tissue (IntraMAT) infiltration. Methods: This was a 3‐year prospective study involving 66 adults aged ≥60 years. Magnetic resonance imaging (MRI) was performed on the knee and thigh. At baseline, muscle volume and IntraMAT ratio were assessed for the rectus femoris, vastus medialis (VM), vastus intermedius, vastus lateralis, and entire quadriceps muscles. At baseline and follow‐up, the T2 relaxation time and volume of the weight‐bearing area of the medial femoral cartilage were measured. Cartilage quality degeneration over 3 years was assessed using the change in T2 relaxation time (ΔT2). A paired t ‐test was performed to compare the cartilage T2 relaxation time and volume at baseline and follow‐up. Linear regression analyses were performed to examine associations of quadriceps muscle volume and IntraMAT at baseline with ΔT2. The final regression model was adjusted for sex, age, height, body mass, and cartilage T2 relaxation time at baseline. Results: Of the 66 participants, 48 completed both the baseline and follow‐up MRI. Over 3 years, cartilage T2 relaxation time significantly increased ( p < 0.001), whereas cartilage volume remained unchanged ( p = 0.761). Linear regression analyses revealed that a higher baseline VM IntraMAT ratio was significantly associated with greater 3‐year ΔT2 (regression coefficient [ B ] = 0.980; 95% confidence interval, 0.282–1.677; p = 0.007). Conclusion: Baseline VM IntraMAT infiltration was associated with the 3‐year progression of medial femoral cartilage quality degeneration.
- 5 November 2026
- Published by Wiley in Clinical Physiology and Functional Imaging
- Vol. 46 (6) , e70107
Higher intramuscular fat infiltration of the vastus medialis is associated with progression of femoral cartilage quality degeneration after 3 years
Purpose: This study aimed to determine whether the progression of medial femoral cartilage quality degeneration is associated with baseline measures of quadriceps muscle atrophy or intramuscular adipose tissue (IntraMAT) infiltration. Methods: This was a 3‐year prospective study involving 66 adults aged ≥60 years. Magnetic resonance imaging (MRI) was performed on the knee and thigh. At baseline, muscle volume and IntraMAT ratio were assessed for the rectus femoris, vastus medialis (VM), vastus intermedius, vastus lateralis, and entire quadriceps muscles. At baseline and follow‐up, the T2 relaxation time and volume of the weight‐bearing area of the medial femoral cartilage were measured. Cartilage quality degeneration over 3 years was assessed using the change in T2 relaxation time (ΔT2). A paired t ‐test was performed to compare the cartilage T2 relaxation time and volume at baseline and follow‐up. Linear regression analyses were performed to examine associations of quadriceps muscle volume and IntraMAT at baseline with ΔT2. The final regression model was adjusted for sex, age, height, body mass, and cartilage T2 relaxation time at baseline. Results: Of the 66 participants, 48 completed both the baseline and follow‐up MRI. Over 3 years, cartilage T2 relaxation time significantly increased ( p < 0.001), whereas cartilage volume remained unchanged ( p = 0.761). Linear regression analyses revealed that a higher baseline VM IntraMAT ratio was significantly associated with greater 3‐year ΔT2 (regression coefficient [ B ] = 0.980; 95% confidence interval, 0.282–1.677; p = 0.007). Conclusion: Baseline VM IntraMAT infiltration was associated with the 3‐year progression of medial femoral cartilage quality degeneration.
- 9 September 2026
- Published by Elsevier in Archives of Gerontology and Geriatrics
- Vol. 151, 106407
Heterogeneous and partially uncoupled muscle degeneration patterns in older adults: a 3-year longitudinal MRI study
- 9 September 2026
- Published by Elsevier in Archives of Gerontology and Geriatrics
- Vol. 151, 106407
Heterogeneous and partially uncoupled muscle degeneration patterns in older adults: a 3-year longitudinal MRI study
- 16 July 2026
- Published by Springer Nature in Annals of Biomedical Engineering
- p. 1-8
Medial Meniscus Extrusion During Weight-Bearing in Early-Stage Knee Osteoarthritis
Purpose To determine whether medial meniscus extrusion (MME) measured in the standing or supine position better characterizes early-stage knee osteoarthritis (OA) and to assess the association between MME in the optimal position and physical function. Methods This study included 43 community-dwelling women. MME was measured beneath the medial collateral ligament in the supine and standing positions. Early OA was defined by a Kellgren–Lawrence grade of 0–1, tenderness and/or stiffness around the knee, and a knee society score (KSS) symptom subscore ≤ 22. Thirteen participants were classified as having early OA, and 30 as asymptomatic. Firth logistic regression analysis was used to determine which MME measurement was more strongly associated with early OA. Multiple linear regression analysis was conducted to explore associations between the KSS function subscore and the MME in the predictive position. Results MME standing was significantly greater in the early OA group than in the asymptomatic group (4.5 ± 1.2 mm vs. 3.1 ± 0.9 mm; p < 0.001; d = 1.3) and was independently associated with early knee OA (OR = 18.13 per 1 mm increase, 95%CI 1.88–323.91, p = 0.011). In regression models, MME standing was associated with self-reported knee function (β = − 0.31, p = 0.034), independently of quadriceps strength (β = 0.38, p = 0.004). Conclusion MME measured under weight-bearing conditions can help differentiate individuals with early knee OA from asymptomatic individuals with similar radiographic features and is associated with self-reported knee function, suggesting its potential as an adjunctive clinical indicator.
- 16 July 2026
- Published by Springer Nature in Annals of Biomedical Engineering
- p. 1-8
Medial Meniscus Extrusion During Weight-Bearing in Early-Stage Knee Osteoarthritis
Purpose To determine whether medial meniscus extrusion (MME) measured in the standing or supine position better characterizes early-stage knee osteoarthritis (OA) and to assess the association between MME in the optimal position and physical function. Methods This study included 43 community-dwelling women. MME was measured beneath the medial collateral ligament in the supine and standing positions. Early OA was defined by a Kellgren–Lawrence grade of 0–1, tenderness and/or stiffness around the knee, and a knee society score (KSS) symptom subscore ≤ 22. Thirteen participants were classified as having early OA, and 30 as asymptomatic. Firth logistic regression analysis was used to determine which MME measurement was more strongly associated with early OA. Multiple linear regression analysis was conducted to explore associations between the KSS function subscore and the MME in the predictive position. Results MME standing was significantly greater in the early OA group than in the asymptomatic group (4.5 ± 1.2 mm vs. 3.1 ± 0.9 mm; p < 0.001; d = 1.3) and was independently associated with early knee OA (OR = 18.13 per 1 mm increase, 95%CI 1.88–323.91, p = 0.011). In regression models, MME standing was associated with self-reported knee function (β = − 0.31, p = 0.034), independently of quadriceps strength (β = 0.38, p = 0.004). Conclusion MME measured under weight-bearing conditions can help differentiate individuals with early knee OA from asymptomatic individuals with similar radiographic features and is associated with self-reported knee function, suggesting its potential as an adjunctive clinical indicator.
- 21 April 2026
- Published by Springer Nature in European Journal of Applied Physiology
- Vol. 126 (7) , 3903-3916
Gearing in the human medial gastrocnemius: effects of contraction conditions, tissue stiffness, and echo intensity
In isolated animal muscles, contraction intensity and tissue stiffness have been shown to be related to gearing. However, these relationships remain poorly understood in humans. This study aimed to clarify how contraction intensity and velocity impact gearing and their relationship with tissue properties in humans. Fifty-two healthy young adults participated in this study. We measured the shear elastic modulus of the medial gastrocnemius muscle, its aponeurosis, and the Achilles tendon, as well as muscle echo intensity. The shear elastic modulus of the aponeurosis was used for analysis as the ratio of transverse to longitudinal directions. Belly segment gear was quantified using ultrasound images of the medial gastrocnemius during isokinetic and isometric plantarflexion. During isometric contraction, belly segment gear under 60% MVC (1.054 ± 0.029) was significantly greater than that under 20% MVC (1.029 ± 0.044). In contrast, during isokinetic contraction, no significant difference between belly segment gear under 100°/s (1.053 ± 0.024) and that under 20°/s (1.056 ± 0.021) was observed. During lower-intensity, higher-velocity isokinetic contractions, greater belly segment gear was associated with a higher transverse to longitudinal stiffness ratio of the superficial aponeurosis (β = 0.274, p = 0.038), lower tendon stiffness (β=-0.312, p = 0.021), and lower echo intensity (β=-0.308, p = 0.021). Furthermore, mediation analysis revealed that the effect of aponeurosis stiffness on torque through belly segment gear was significant (indirect effect = 4.35; 95% confidence interval, 0.11-10.09). Belly segment gear was associated with contraction intensity and connective tissue properties.
- 21 April 2026
- Published by Springer Nature in European Journal of Applied Physiology
- Vol. 126 (7) , 3903-3916
Gearing in the human medial gastrocnemius: effects of contraction conditions, tissue stiffness, and echo intensity
In isolated animal muscles, contraction intensity and tissue stiffness have been shown to be related to gearing. However, these relationships remain poorly understood in humans. This study aimed to clarify how contraction intensity and velocity impact gearing and their relationship with tissue properties in humans. Fifty-two healthy young adults participated in this study. We measured the shear elastic modulus of the medial gastrocnemius muscle, its aponeurosis, and the Achilles tendon, as well as muscle echo intensity. The shear elastic modulus of the aponeurosis was used for analysis as the ratio of transverse to longitudinal directions. Belly segment gear was quantified using ultrasound images of the medial gastrocnemius during isokinetic and isometric plantarflexion. During isometric contraction, belly segment gear under 60% MVC (1.054 ± 0.029) was significantly greater than that under 20% MVC (1.029 ± 0.044). In contrast, during isokinetic contraction, no significant difference between belly segment gear under 100°/s (1.053 ± 0.024) and that under 20°/s (1.056 ± 0.021) was observed. During lower-intensity, higher-velocity isokinetic contractions, greater belly segment gear was associated with a higher transverse to longitudinal stiffness ratio of the superficial aponeurosis (β = 0.274, p = 0.038), lower tendon stiffness (β=-0.312, p = 0.021), and lower echo intensity (β=-0.308, p = 0.021). Furthermore, mediation analysis revealed that the effect of aponeurosis stiffness on torque through belly segment gear was significant (indirect effect = 4.35; 95% confidence interval, 0.11-10.09). Belly segment gear was associated with contraction intensity and connective tissue properties.
- Open Access
- 16 March 2026
- Published by Wiley in Scandinavian Journal of Medicine & Science in Sports
- Vol. 36 (3) , e70260
Sex Differences in Three‐Dimensional Muscle Shape: Disentangling Allometry From Sexual Dimorphism Using Statistical Shape Modeling
Sexual dimorphism in skeletal muscles is evident in both size and shape. As most morphological traits scale with size, disentangling allometric effects from sexual dimorphism is essential for revealing sex‐related shape differences; however, this remains underexplored in human muscles. This study aimed to identify sex differences in muscle shape within the human quadriceps femoris, with a novel approach based on muscle statistical shape modeling. Magnetic resonance images of 43 healthy young adults (22 males and 21 females) were obtained. Muscle size of the four heads of quadriceps femoris was measured, and statistical shape models were developed to quantify the muscle shape variation. Muscle size and shape were compared between males and females, and shape‐based sex classification was performed using linear discrimination. While males showed significantly greater volume, anatomical cross‐sectional area, length, width, and thickness in all muscles, the statistical shape models demonstrated sex‐related shape differences. When adjusting for muscle volume, the primary sex‐related shape differences were largely explained by allometry. However, some distinct sex differences were preserved, specifically for the bulging and shrinkage at different regions in the vastus lateralis and the anterior edge shrinkage, distal bulging, and thickness variation within the vastus medialis. These shape differences distinguished male and female with high accuracy. Our findings revealed that although most sex differences in quadriceps femoris shape are driven by size (allometry), intrinsic shape differences between sexes exist. This study highlights the utility of statistical shape modeling in distinguishing allometric effects from true sexual dimorphism in muscle morphology.
- 16 March 2026
- Published by Wiley in Scandinavian Journal of Medicine & Science in Sports
- Vol. 36 (3) , e70260
Open AccessSex Differences in Three‐Dimensional Muscle Shape: Disentangling Allometry From Sexual Dimorphism Using Statistical Shape Modeling
Sexual dimorphism in skeletal muscles is evident in both size and shape. As most morphological traits scale with size, disentangling allometric effects from sexual dimorphism is essential for revealing sex‐related shape differences; however, this remains underexplored in human muscles. This study aimed to identify sex differences in muscle shape within the human quadriceps femoris, with a novel approach based on muscle statistical shape modeling. Magnetic resonance images of 43 healthy young adults (22 males and 21 females) were obtained. Muscle size of the four heads of quadriceps femoris was measured, and statistical shape models were developed to quantify the muscle shape variation. Muscle size and shape were compared between males and females, and shape‐based sex classification was performed using linear discrimination. While males showed significantly greater volume, anatomical cross‐sectional area, length, width, and thickness in all muscles, the statistical shape models demonstrated sex‐related shape differences. When adjusting for muscle volume, the primary sex‐related shape differences were largely explained by allometry. However, some distinct sex differences were preserved, specifically for the bulging and shrinkage at different regions in the vastus lateralis and the anterior edge shrinkage, distal bulging, and thickness variation within the vastus medialis. These shape differences distinguished male and female with high accuracy. Our findings revealed that although most sex differences in quadriceps femoris shape are driven by size (allometry), intrinsic shape differences between sexes exist. This study highlights the utility of statistical shape modeling in distinguishing allometric effects from true sexual dimorphism in muscle morphology.
- 5 February 2026
- Published by Elsevier in European Journal of Radiology
- Vol. 196, 112714
Corrigendum to “Degeneration of the cartilage quality is correlated with a higher intramuscular fat infiltration of the vastus medialis in older adults with pre-to-mild knee osteoarthritis” [Eur. J. Radiol. 183 (2025) 111930]
- 5 February 2026
- Published by Elsevier in European Journal of Radiology
- Vol. 196, 112714
Corrigendum to “Degeneration of the cartilage quality is correlated with a higher intramuscular fat infiltration of the vastus medialis in older adults with pre-to-mild knee osteoarthritis” [Eur. J. Radiol. 183 (2025) 111930]
- 2 February 2026
- Published by Wiley in Clinical Anatomy
Contraction of the Deep Hip Muscles Contributes to Hip Capsulo‐Ligamentous Complex Tension In Vivo
The anterior hip muscles, especially the iliocapsularis, reflected head of rectus femoris and gluteus minimus, attach to hip capsulo‐ligamentous complex directly, and may contribute to anterior hip stability by increasing the tension of the capsulo‐ligamentous complex by muscle contraction. However, it has not been verified whether the contraction of these muscles actually increases the tension of the capsulo‐ligamentous complex in vivo. The objectives of our study were to clarify (1) whether deep hip muscle contractions increase the tension of the hip capsulo‐ligamentous complex, and (2) which muscles most affect the changes in the tension of the capsulo‐ligamentous complex. Twenty‐eight healthy young individuals (22.8 ± 1.6 years) participated. The tasks included isometric hip flexion, abduction, adduction, and knee extension contraction and rest in a supine position. The shear elastic moduli ( G ) of the capsulo‐ligamentous complex, iliocapsularis, rectus femoris, and gluteus minimus were measured using shear wave elastography. Higher G values correspond to increased muscle activity and tension of the capsulo‐ligamentous complex. The G of the capsulo‐ligamentous complex showed higher in hip abduction contraction than in the resting position ( p = 0.008). The results of the multiple regression analysis showed that only the amount of change in G of the iliocapsularis was a significant variable, even when adjusted for maximum torque (R 2 = 0.412, β = 0.513, p = 0.009). The tension of the hip capsulo‐ligamentous complex increased with isometric hip abduction, implying tension transfer between the muscle and the capsulo‐ligamentous complex. Furthermore, the iliocapsularis has been suggested to play an important role in the transmission of tension.
- 2 February 2026
- Published by Wiley in Clinical Anatomy
Contraction of the Deep Hip Muscles Contributes to Hip Capsulo‐Ligamentous Complex Tension In Vivo
The anterior hip muscles, especially the iliocapsularis, reflected head of rectus femoris and gluteus minimus, attach to hip capsulo‐ligamentous complex directly, and may contribute to anterior hip stability by increasing the tension of the capsulo‐ligamentous complex by muscle contraction. However, it has not been verified whether the contraction of these muscles actually increases the tension of the capsulo‐ligamentous complex in vivo. The objectives of our study were to clarify (1) whether deep hip muscle contractions increase the tension of the hip capsulo‐ligamentous complex, and (2) which muscles most affect the changes in the tension of the capsulo‐ligamentous complex. Twenty‐eight healthy young individuals (22.8 ± 1.6 years) participated. The tasks included isometric hip flexion, abduction, adduction, and knee extension contraction and rest in a supine position. The shear elastic moduli ( G ) of the capsulo‐ligamentous complex, iliocapsularis, rectus femoris, and gluteus minimus were measured using shear wave elastography. Higher G values correspond to increased muscle activity and tension of the capsulo‐ligamentous complex. The G of the capsulo‐ligamentous complex showed higher in hip abduction contraction than in the resting position ( p = 0.008). The results of the multiple regression analysis showed that only the amount of change in G of the iliocapsularis was a significant variable, even when adjusted for maximum torque (R 2 = 0.412, β = 0.513, p = 0.009). The tension of the hip capsulo‐ligamentous complex increased with isometric hip abduction, implying tension transfer between the muscle and the capsulo‐ligamentous complex. Furthermore, the iliocapsularis has been suggested to play an important role in the transmission of tension.
- 6 January 2026
- Published by Springer Nature in Annals of Biomedical Engineering
- Vol. 54 (5) , 1425-1434
Severity-Dependent Contributions of Knee Adduction Moment Lever Arm Components and Associated Gait Variables in Medial Knee Osteoarthritis
Purpose To investigate the contribution of knee adduction moment (KAM) lever arm components and examine their relationships with gait variables in Early-mild and Severe osteoarthritis (OA) groups. Methods Female patients with medial knee OA were classified into two groups: Early-mild (Kellgren-Lawrence (KL) grade 1–2, n = 46) and Severe (KL 3–4, n = 40). At the first peak of KAM, we measured the lever arm; the lateral positions of the body center of mass, knee joint center, and foot center of pressure (foot COP); and the frontal plane angles of the trunk, pelvis, hip, and knee. Additionally, foot progression angle and step width were measured. Hierarchical multiple regression determined the contribution of lever arm components, and partial correlation assessed their relationships with gait variables. Results In both groups, smaller knee varus angle (Early-mild: β = 0.563; Severe: β = 0.346) and more lateral foot COP position (Early-mild: β = − 0.316; Severe: β = − 0.686) were associated with a shorter lever arm. Knee varus angle and foot COP explained 46.4% and 4.8% of lever arm variance in Early-mild group, and 11.3% and 35.6% in Severe group. Smaller contralateral pelvic drop and greater hip adduction related to smaller knee varus angle. Especially in Early-mild OA, greater toe-in was associated with smaller knee varus. Additionally, greater toe-in and wider step width were related to foot COP closer to the knee. Conclusions The characteristics of the contributions of the lever arm components and related gait variables were revealed in Early-mild and Severe OA. These findings may inform gait strategies to reduce KAM.
- 6 January 2026
- Published by Springer Nature in Annals of Biomedical Engineering
- Vol. 54 (5) , 1425-1434
Severity-Dependent Contributions of Knee Adduction Moment Lever Arm Components and Associated Gait Variables in Medial Knee Osteoarthritis
Purpose To investigate the contribution of knee adduction moment (KAM) lever arm components and examine their relationships with gait variables in Early-mild and Severe osteoarthritis (OA) groups. Methods Female patients with medial knee OA were classified into two groups: Early-mild (Kellgren-Lawrence (KL) grade 1–2, n = 46) and Severe (KL 3–4, n = 40). At the first peak of KAM, we measured the lever arm; the lateral positions of the body center of mass, knee joint center, and foot center of pressure (foot COP); and the frontal plane angles of the trunk, pelvis, hip, and knee. Additionally, foot progression angle and step width were measured. Hierarchical multiple regression determined the contribution of lever arm components, and partial correlation assessed their relationships with gait variables. Results In both groups, smaller knee varus angle (Early-mild: β = 0.563; Severe: β = 0.346) and more lateral foot COP position (Early-mild: β = − 0.316; Severe: β = − 0.686) were associated with a shorter lever arm. Knee varus angle and foot COP explained 46.4% and 4.8% of lever arm variance in Early-mild group, and 11.3% and 35.6% in Severe group. Smaller contralateral pelvic drop and greater hip adduction related to smaller knee varus angle. Especially in Early-mild OA, greater toe-in was associated with smaller knee varus. Additionally, greater toe-in and wider step width were related to foot COP closer to the knee. Conclusions The characteristics of the contributions of the lever arm components and related gait variables were revealed in Early-mild and Severe OA. These findings may inform gait strategies to reduce KAM.
- 1 January 2026
- Published by Human Kinetics in Journal of Sport Rehabilitation
- Vol. -1 (aop) , 1-8
Do Ober Tests Reflect Iliotibial Band Stiffness? A Preliminary Shear Wave Elastography Study
Context : Clinical tests, such as the Ober, and modified Ober tests are commonly used to assess iliotibial band (ITB) stiffness. Whether these tests can be used to evaluate ITB stiffness in vivo, or whether alternatives are available remains unclear. We aimed to investigate whether commonly used and alternative clinical tests reflect ITB stiffness in vivo . Design : Cross-sectional. Methods : Thirty-five healthy males underwent the traditional Ober and modified versions of the Ober tes, including variations performed with the tested hip in extension, as well as a hip extension test with tibial external rotation. We defined positive cutoff values as < 0° of hip adduction for the Ober test and Ober test with the tested hip in extension, Results : Higher ITB stiffness was associated with positive findings in the modified Ober test performed with the tested hip in extension (odds ratio = 1.03, 95% confidence interval = 1.00–1.06, P = .04) and the hip extension test with tibial external rotation (odds ratio = 1.04, 95% confidence interval = 1.00–1.07, P = .03). The traditional Ober and modified Ober tests were not associated with ITB stiffness. Conclusions : Traditional Ober-based tests may have limited utility for evaluating ITB stiffness in vivo . Modified testing positions, particularly the modified Ober test with the tested hip in extension and the hip extension test with tibial external rotation, may better reflect ITB stiffness.
- 1 January 2026
- Published by Human Kinetics in Journal of Sport Rehabilitation
- Vol. -1 (aop) , 1-8
Do Ober Tests Reflect Iliotibial Band Stiffness? A Preliminary Shear Wave Elastography Study
Context : Clinical tests, such as the Ober, and modified Ober tests are commonly used to assess iliotibial band (ITB) stiffness. Whether these tests can be used to evaluate ITB stiffness in vivo, or whether alternatives are available remains unclear. We aimed to investigate whether commonly used and alternative clinical tests reflect ITB stiffness in vivo . Design : Cross-sectional. Methods : Thirty-five healthy males underwent the traditional Ober and modified versions of the Ober tes, including variations performed with the tested hip in extension, as well as a hip extension test with tibial external rotation. We defined positive cutoff values as < 0° of hip adduction for the Ober test and Ober test with the tested hip in extension, Results : Higher ITB stiffness was associated with positive findings in the modified Ober test performed with the tested hip in extension (odds ratio = 1.03, 95% confidence interval = 1.00–1.06, P = .04) and the hip extension test with tibial external rotation (odds ratio = 1.04, 95% confidence interval = 1.00–1.07, P = .03). The traditional Ober and modified Ober tests were not associated with ITB stiffness. Conclusions : Traditional Ober-based tests may have limited utility for evaluating ITB stiffness in vivo . Modified testing positions, particularly the modified Ober test with the tested hip in extension and the hip extension test with tibial external rotation, may better reflect ITB stiffness.