Shrikant R. Bharadwaj
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Shrikant R. Bharadwaj has a total of 120 co-authors. Here are the top co-authors by number of shared publications:
Pravin K. Vaddavalli
Shantilal Sanghvi Cornea Institute L V Prasad Eye Institute Hyderabad Telangana India
5 shared publicationsChristopher W. Tyler
Centre for Applied Vision Research, City St. George's, University of London, Northampton Square, London, United Kingdom
4 shared publicationsPravin Krishna Vaddavalli
The Cornea Institute, L V Prasad Eye Institute, Road no. 2, Banjara Hills, Hyderabad 500034, Telangana, India
4 shared publicationsPreetirupa Devi
Brien Holden Institute of Optometry and Vision Sciences, LV Prasad Eye Institute, Banjara Hills, Hyderabad, Telangana, India
4 shared publications- PremNandhini Satgunam
L V Prasad Eye Institute
4 shared publications Clifton M. Schor
Herbert Wertheim School of Optometry University of California at Berkeley Berkeley California USA
3 shared publications
Latest Publications
- Open Access
- 1 June 2026
- Published by Association for Research in Vision and Ophthalmology (ARVO) in Investigative Ophthalmology & Visual Science
- Vol. 67 (6) , 52
Reduced Image Quality Impairs Monocular Blur-Driven Accommodation in Keratoconus
The purpose of this study was to test the hypotheses that (1) monocular blur-driven accommodation is attenuated in keratoconus due to weaker defocus-blur signals arising from degraded image quality (IQ) compared with non-keratoconic controls, and (2) manipulating the strength of defocus-blur signal, either by correcting higher-order aberrations (HOAs) in keratoconus or by inducing keratoconic HOAs in controls, will correspondingly improve or degrade accommodative performance. Monochromatic IQ degradation was computed from HOAs of 15 mild-to-moderate keratoconic participants (13-29 years) and 15 controls for a 4.5-mm pupil diameter. Participants monocularly accommodated to 0.5 to 4.0 diopter (D) hyperopic step changes whereas their lower-order aberrations (LOAs) or both LOAs and HOAs were corrected using an adaptive optics visual simulator. The protocol was repeated in 10 controls with induced HOAs from one moderate keratoconic eye. IQ loss with induced blur was significantly lower in patients with keratoconus than in healthy controls (P < 0.001). Accommodative responses were reduced in keratoconus (0.6 ± 0.9 D across the 4-D range) compared with controls (2.6 ± 1.1 D, P < 0.01) and were correlated with the corresponding IQ loss (r = 0.75, P < 0.001). Although IQ improved with combined LOA + HOA correction in keratoconus, no significant change in accommodation was observed (P = 0.58). Inducing keratoconic HOAs, however, significantly attenuated accommodation in controls (0.27 ± 0.41 D, P = 0.001). Reduced monocular accommodation is consistent with weakened defocus-blur signals available to drive these responses in keratoconic eyes. The absence of improvement in accommodation despite optical quality enhancement may indicate a limited role of pure defocus as an accommodative cue and/or reduced neural sensitivity to blur following chronically degraded retinal images.
- 1 June 2026
- Published by Association for Research in Vision and Ophthalmology (ARVO) in Investigative Ophthalmology & Visual Science
- Vol. 67 (6) , 52
Open AccessReduced Image Quality Impairs Monocular Blur-Driven Accommodation in Keratoconus
The purpose of this study was to test the hypotheses that (1) monocular blur-driven accommodation is attenuated in keratoconus due to weaker defocus-blur signals arising from degraded image quality (IQ) compared with non-keratoconic controls, and (2) manipulating the strength of defocus-blur signal, either by correcting higher-order aberrations (HOAs) in keratoconus or by inducing keratoconic HOAs in controls, will correspondingly improve or degrade accommodative performance. Monochromatic IQ degradation was computed from HOAs of 15 mild-to-moderate keratoconic participants (13-29 years) and 15 controls for a 4.5-mm pupil diameter. Participants monocularly accommodated to 0.5 to 4.0 diopter (D) hyperopic step changes whereas their lower-order aberrations (LOAs) or both LOAs and HOAs were corrected using an adaptive optics visual simulator. The protocol was repeated in 10 controls with induced HOAs from one moderate keratoconic eye. IQ loss with induced blur was significantly lower in patients with keratoconus than in healthy controls (P < 0.001). Accommodative responses were reduced in keratoconus (0.6 ± 0.9 D across the 4-D range) compared with controls (2.6 ± 1.1 D, P < 0.01) and were correlated with the corresponding IQ loss (r = 0.75, P < 0.001). Although IQ improved with combined LOA + HOA correction in keratoconus, no significant change in accommodation was observed (P = 0.58). Inducing keratoconic HOAs, however, significantly attenuated accommodation in controls (0.27 ± 0.41 D, P = 0.001). Reduced monocular accommodation is consistent with weakened defocus-blur signals available to drive these responses in keratoconic eyes. The absence of improvement in accommodation despite optical quality enhancement may indicate a limited role of pure defocus as an accommodative cue and/or reduced neural sensitivity to blur following chronically degraded retinal images.
- 1 March 2026
- Published by Wiley in Optometry and Vision Science
- Vol. 103 (3) , e70021
Interocular mismatches of high‐order wavefront aberrations impair stereoacuity following refractive surgeries by reducing the disparity signal quality
Purpose: (1) To investigate if binocular cross‐correlation metrics derived from the aberrated monocular retinal images can explain the deterioration of stereoacuity following keratorefractive surgeries. (2) To investigate if the quality of binocular metrics improves with improved monocular retinal image quality and pupil miosis. Methods: High‐order aberrations (HOAs) were obtained over 6 mm pupil diameter from 99 young adults undergoing photorefractive keratectomy (PRK) ( n = 26), laser‐assisted in situ keratomileusis (LASIK) ( n = 38), and ReLEx small‐incision lenticule extraction (SMILE; n = 35) for myopia correction. Point spread functions derived from HOAs were convolved with random‐dot stereo pairs and cross‐correlated to obtain four binocular metrics—signal width, signal height, signal‐to‐noise ratio, and height‐to‐width ratio—that signified the quality of the disparity signal. These metrics were derived pre‐operatively and at 1‐week, 1‐month, 3‐month, and 6‐month after surgeries, and correlated with the subject's stereoacuity for 6 mm pupil diameters. Binocular metrics were also derived for 4 mm pupil diameters and compared with the 6 mm data. Results: Larger interocular differences in retinal image quality led to reduced disparity signal quality and less optimal values of the binocular metrics. These trends were strongly correlated with the subject's stereoacuity across refractive surgeries ( ρ ≥ 0.71; p < 0.001). Relative to pre‐operative values, post‐operative metrics worsened at 1‐week followed by a recovery period ( p < 0.001). All post‐operative metrics for PRK and LASIK surgeries were similar ( p ≥ 0.67), but worse than SMILE surgery ( p < 0.001). The binocular metrics derived for the 4 mm pupil diameters were superior to those of the 6 mm pupil diameters ( p < 0.001). Conclusions: Binocular cross‐correlation metrics derived from the aberrated monocular retinal images signify the strength of the disparity signal, and capture much of the stereoacuity losses following keratorefractive surgeries for myopia. Binocularity may be better preserved after SMILE surgery owing to the smaller interocular mismatches in optical quality, relative to PRK and LASIK surgeries for comparable pupil diameters.
- 1 March 2026
- Published by Wiley in Optometry and Vision Science
- Vol. 103 (3) , e70021
Interocular mismatches of high‐order wavefront aberrations impair stereoacuity following refractive surgeries by reducing the disparity signal quality
Purpose: (1) To investigate if binocular cross‐correlation metrics derived from the aberrated monocular retinal images can explain the deterioration of stereoacuity following keratorefractive surgeries. (2) To investigate if the quality of binocular metrics improves with improved monocular retinal image quality and pupil miosis. Methods: High‐order aberrations (HOAs) were obtained over 6 mm pupil diameter from 99 young adults undergoing photorefractive keratectomy (PRK) ( n = 26), laser‐assisted in situ keratomileusis (LASIK) ( n = 38), and ReLEx small‐incision lenticule extraction (SMILE; n = 35) for myopia correction. Point spread functions derived from HOAs were convolved with random‐dot stereo pairs and cross‐correlated to obtain four binocular metrics—signal width, signal height, signal‐to‐noise ratio, and height‐to‐width ratio—that signified the quality of the disparity signal. These metrics were derived pre‐operatively and at 1‐week, 1‐month, 3‐month, and 6‐month after surgeries, and correlated with the subject's stereoacuity for 6 mm pupil diameters. Binocular metrics were also derived for 4 mm pupil diameters and compared with the 6 mm data. Results: Larger interocular differences in retinal image quality led to reduced disparity signal quality and less optimal values of the binocular metrics. These trends were strongly correlated with the subject's stereoacuity across refractive surgeries ( ρ ≥ 0.71; p < 0.001). Relative to pre‐operative values, post‐operative metrics worsened at 1‐week followed by a recovery period ( p < 0.001). All post‐operative metrics for PRK and LASIK surgeries were similar ( p ≥ 0.67), but worse than SMILE surgery ( p < 0.001). The binocular metrics derived for the 4 mm pupil diameters were superior to those of the 6 mm pupil diameters ( p < 0.001). Conclusions: Binocular cross‐correlation metrics derived from the aberrated monocular retinal images signify the strength of the disparity signal, and capture much of the stereoacuity losses following keratorefractive surgeries for myopia. Binocularity may be better preserved after SMILE surgery owing to the smaller interocular mismatches in optical quality, relative to PRK and LASIK surgeries for comparable pupil diameters.
- 1 February 2026
- Published by Wiley in Optometry and Vision Science
- Vol. 103 (2) , e70024
Assessment of eye movement endurance using the OculoMotor Assessment Tool: A replication study on young Indian adults
Purpose: This replication study sought to determine (1) the frequency of horizontal/vertical saccades, vergence jumps, and horizontal/vertical vestibulo‐ocular reflexes (VORs) elicited per minute in young Indian adults using the OculoMotor and Vestibular Endurance Screening (MoVES) protocol with the OculoMotor Assessment Tool (OMAT) and (2) the association between the participant's MoVES values and routine clinical binocular vision status. Methods: Two hundred twenty‐two healthy participants (17–33 years) repeatedly generated the aforesaid eye movements using the OMAT as a target for 60 s. A subset ( n = 75) also underwent binocular vision assessment using standard optometric protocols. Eye movement frequency of participants with a near point of convergence ≤ 6 cm, stereoacuity ≤ 70 arcsec, and BIVSS score ≤ 31 constituted the normative cohort. Results: Eye movement responses of 153 participants who formed the replication cohort showed a higher frequency in the last 30 s compared to the initial 30 s ( p < 0.01). The overall frequency of vergence jumps was lower in those who failed these criteria, vis‐à‐vis, the pass cohort ( p < 0.01). These values were lower than previously published data from USA ( p ≤ 0.05), but the differences diminished when matched with participants in organized sports activities. The clinical binocular vision parameters did not show a strong correlation with oculomotor frequency ( r ≤ 0.3). Conclusions: The endurance values of eye movements established here allow screening for oculomotor dysfunctions in young Indian adults. These values may be impacted significantly by the level of organized physical activity engaged by the participant. Routine binocular vision evaluation does not correlate with eye movement endurance values, reflecting the need for dedicated assessments of the latter functions using standardized techniques and tools.
- 1 February 2026
- Published by Wiley in Optometry and Vision Science
- Vol. 103 (2) , e70024
Assessment of eye movement endurance using the OculoMotor Assessment Tool: A replication study on young Indian adults
Purpose: This replication study sought to determine (1) the frequency of horizontal/vertical saccades, vergence jumps, and horizontal/vertical vestibulo‐ocular reflexes (VORs) elicited per minute in young Indian adults using the OculoMotor and Vestibular Endurance Screening (MoVES) protocol with the OculoMotor Assessment Tool (OMAT) and (2) the association between the participant's MoVES values and routine clinical binocular vision status. Methods: Two hundred twenty‐two healthy participants (17–33 years) repeatedly generated the aforesaid eye movements using the OMAT as a target for 60 s. A subset ( n = 75) also underwent binocular vision assessment using standard optometric protocols. Eye movement frequency of participants with a near point of convergence ≤ 6 cm, stereoacuity ≤ 70 arcsec, and BIVSS score ≤ 31 constituted the normative cohort. Results: Eye movement responses of 153 participants who formed the replication cohort showed a higher frequency in the last 30 s compared to the initial 30 s ( p < 0.01). The overall frequency of vergence jumps was lower in those who failed these criteria, vis‐à‐vis, the pass cohort ( p < 0.01). These values were lower than previously published data from USA ( p ≤ 0.05), but the differences diminished when matched with participants in organized sports activities. The clinical binocular vision parameters did not show a strong correlation with oculomotor frequency ( r ≤ 0.3). Conclusions: The endurance values of eye movements established here allow screening for oculomotor dysfunctions in young Indian adults. These values may be impacted significantly by the level of organized physical activity engaged by the participant. Routine binocular vision evaluation does not correlate with eye movement endurance values, reflecting the need for dedicated assessments of the latter functions using standardized techniques and tools.
- Open Access
- 1 December 2025
- Published by Association for Research in Vision and Ophthalmology (ARVO) in Investigative Ophthalmology & Visual Science
- Vol. 66 (15) , 8
The Impact of Induced Optical Blur on Monocular and Binocular Depth-Related Visuomotor Task Performance
The purpose of this study was to determine the impact of induced optical blur on a 3D task that probes complex visuomotor performance capabilities of humans. Fifteen visually normal, cyclopleged adults (mean ± 1 SD = 23 ± 2.6 years) guided a metal loop along a wire convoluted in depth without making contact, while being video recorded for analysis. The task was performed binocularly and monocularly, without blur, and with two magnitudes of induced spherical and astigmatic blur of equal strengths (2.25 diopters [D] and 6.25 D). Blur patterns were induced before both eyes (isometropia) or before only one eye (anisometropia). For isometropic astigmatism, blur was also induced with parallel and orthogonal axes in both eyes. The buzz-wire patterns, viewing condition, and induced blur were all randomized across participants. Binocular error rate (number of loop-to-wire contacts per second) and error duration (percentage of time spent making errors) increased at high blur strength (P < 0.001), more so for astigmatism than spherical power (p < 0.001) and more so for isometropic than anisometropic viewing (P = 0.02). Low astigmatism with orthogonal axes bilaterally produced higher error rate and error duration than astigmatism with parallel axes bilaterally (P < 0.001). Only error duration increased with high blur for monocular viewing (P ≤ 0.004). Task speed remained invariant across test conditions. Multiple repetitions did not impact task performance. The deterioration of depth-related visuomotor task performance with optical blur depends on its magnitude, radial symmetry and the similarity between the two eyes. Performance drop is largely from spending more time making/correcting errors, whereas the overall speed remained undiminished.
- 1 December 2025
- Published by Association for Research in Vision and Ophthalmology (ARVO) in Investigative Ophthalmology & Visual Science
- Vol. 66 (15) , 8
Open AccessThe Impact of Induced Optical Blur on Monocular and Binocular Depth-Related Visuomotor Task Performance
The purpose of this study was to determine the impact of induced optical blur on a 3D task that probes complex visuomotor performance capabilities of humans. Fifteen visually normal, cyclopleged adults (mean ± 1 SD = 23 ± 2.6 years) guided a metal loop along a wire convoluted in depth without making contact, while being video recorded for analysis. The task was performed binocularly and monocularly, without blur, and with two magnitudes of induced spherical and astigmatic blur of equal strengths (2.25 diopters [D] and 6.25 D). Blur patterns were induced before both eyes (isometropia) or before only one eye (anisometropia). For isometropic astigmatism, blur was also induced with parallel and orthogonal axes in both eyes. The buzz-wire patterns, viewing condition, and induced blur were all randomized across participants. Binocular error rate (number of loop-to-wire contacts per second) and error duration (percentage of time spent making errors) increased at high blur strength (P < 0.001), more so for astigmatism than spherical power (p < 0.001) and more so for isometropic than anisometropic viewing (P = 0.02). Low astigmatism with orthogonal axes bilaterally produced higher error rate and error duration than astigmatism with parallel axes bilaterally (P < 0.001). Only error duration increased with high blur for monocular viewing (P ≤ 0.004). Task speed remained invariant across test conditions. Multiple repetitions did not impact task performance. The deterioration of depth-related visuomotor task performance with optical blur depends on its magnitude, radial symmetry and the similarity between the two eyes. Performance drop is largely from spending more time making/correcting errors, whereas the overall speed remained undiminished.
- Open Access
- 17 September 2025
- Published by Annual Reviews in Annual Review of Vision Science
- Vol. 11 (1) , 19-41
Ocular Accommodation: The Autofocus Mechanism of the Human Eye
Ocular accommodation, the autofocus mechanism of the human eye, is fundamental for the achievement and maintenance of clear vision across viewing distances. Together with its close ally, vergence eye movements, this mechanism also ensures that binocular single vision is achieved at all these distances. Several dimensions of this mechanism have been investigated for well over a century. The present article summarizes this large volume of work under three themes: ( a ) biomechanics and neural control of the accommodative apparatus, ( b ) its behavioral properties, and ( c ) control-engineering modeling endeavors that offer a theoretical framework for gaining insights into the functioning of this mechanism. Built into these themes is a discussion on the development of accommodation, its loss with aging (presbyopia), sensory cues that aid the generation of these responses, and the technologies available for the measurement of these responses. The article also raises several unresolved questions for future research.
- 17 September 2025
- Published by Annual Reviews in Annual Review of Vision Science
- Vol. 11 (1) , 19-41
Open AccessOcular Accommodation: The Autofocus Mechanism of the Human Eye
Ocular accommodation, the autofocus mechanism of the human eye, is fundamental for the achievement and maintenance of clear vision across viewing distances. Together with its close ally, vergence eye movements, this mechanism also ensures that binocular single vision is achieved at all these distances. Several dimensions of this mechanism have been investigated for well over a century. The present article summarizes this large volume of work under three themes: ( a ) biomechanics and neural control of the accommodative apparatus, ( b ) its behavioral properties, and ( c ) control-engineering modeling endeavors that offer a theoretical framework for gaining insights into the functioning of this mechanism. Built into these themes is a discussion on the development of accommodation, its loss with aging (presbyopia), sensory cues that aid the generation of these responses, and the technologies available for the measurement of these responses. The article also raises several unresolved questions for future research.
- Open Access
- 9 July 2025
- Published by Scilight Press Pty Ltd in Journal of Bio-optics
- Vol. 1 (1) , 4
Eccentric Infrared Photorefraction: A Review of Evolution, Optical Design, Features and Applications
Photorefraction is seven-decade old technology that allows objective and non-invasive estimation of the eye’s refractive error using retro-illuminated photographs of the pupil. A special variant of this technique—eccentric infrared photorefraction—has now become the technology of choice for the screening of uncorrected refractive errors and other amblyogenic factors in the pediatric population. Eccentric infrared photorefraction is also the preferred measurement tool for scientific investigations on the physiology and pathobiology of the near-triadic reflex (accommodation, convergence and pupil miosis). Broadly, this technique uses an extended near-infrared light source that is mounted eccentric to the camera aperture to illuminate the retina. The optically double-pass reflected light generates a retro-illuminated luminance profile across the pupil, the gradient of which may be used to estimate the eye’s refractive power using standard calibration techniques. The present review summarizes the origins of photorefraction and then delves into the optical principles of eccentric infrared photorefraction, its properties, calibration techniques and associated pitfalls. The review also discusses the present and future use-cases of this technology. Overall, this review provides the basics of photorefraction for early readers of this topic and offers some practical guidelines for the moderate to advanced users of this technique.
- 9 July 2025
- Published by Scilight Press Pty Ltd in Journal of Bio-optics
- Vol. 1 (1) , 4
Open AccessEccentric Infrared Photorefraction: A Review of Evolution, Optical Design, Features and Applications
Photorefraction is seven-decade old technology that allows objective and non-invasive estimation of the eye’s refractive error using retro-illuminated photographs of the pupil. A special variant of this technique—eccentric infrared photorefraction—has now become the technology of choice for the screening of uncorrected refractive errors and other amblyogenic factors in the pediatric population. Eccentric infrared photorefraction is also the preferred measurement tool for scientific investigations on the physiology and pathobiology of the near-triadic reflex (accommodation, convergence and pupil miosis). Broadly, this technique uses an extended near-infrared light source that is mounted eccentric to the camera aperture to illuminate the retina. The optically double-pass reflected light generates a retro-illuminated luminance profile across the pupil, the gradient of which may be used to estimate the eye’s refractive power using standard calibration techniques. The present review summarizes the origins of photorefraction and then delves into the optical principles of eccentric infrared photorefraction, its properties, calibration techniques and associated pitfalls. The review also discusses the present and future use-cases of this technology. Overall, this review provides the basics of photorefraction for early readers of this topic and offers some practical guidelines for the moderate to advanced users of this technique.
- Open Access
- 1 April 2025
- Published by Association for Research in Vision and Ophthalmology (ARVO) in Investigative Ophthalmology & Visual Science
- Vol. 66 (4) , 31
Depth-Related Visuomotor Performance in Keratoconus and Its Relationship to Stereopsis
The purposes of this study were to quantify the impact of degraded binocularity in keratoconus and its improvement with rigid contact lenses on a depth-related visuomotor task that emulates complex activities in daily living; and to determine whether visuomotor performance may be predicted from psychophysical estimates of stereo threshold. Participants were instructed to pass a metal loop around a wire convoluted in depth. Error rate and speed were measured in 26 controls, 30 cases with keratoconus with best-corrected spectacles, a subset of 17 cases with rigid contact lenses, and 10 uncorrected myopes with acuity and stereo thresholds comparable to the keratoconic cohort. Stereo thresholds were determined using random-dot stimuli. Binocular error rates were lower than monocular error rates for controls, uncorrected myopes, and the better-performing half of cases (p < 0.001, for each), but not for the worst-performing half (p = 0.07). Error rates in cases improved with contact lenses (p < 0.001). Within each cohort, the error rate was poorly correlated with the stereo threshold (r2 < 0.12, for each). Monocular speeds were significantly lower than binocular speeds for controls than for cases (p = 0.003) and for uncorrected myopes than cases (p = 0.001). Degraded binocularity in keratoconus may limit the ability to perform depth-related visuomotor tasks. A portion of this loss may be overcome by using rigid contact lenses. The attributes of visuomotor task performance are, however, not predictable from the psychophysical estimates of stereo thresholds.
- 1 April 2025
- Published by Association for Research in Vision and Ophthalmology (ARVO) in Investigative Ophthalmology & Visual Science
- Vol. 66 (4) , 31
Open AccessDepth-Related Visuomotor Performance in Keratoconus and Its Relationship to Stereopsis
The purposes of this study were to quantify the impact of degraded binocularity in keratoconus and its improvement with rigid contact lenses on a depth-related visuomotor task that emulates complex activities in daily living; and to determine whether visuomotor performance may be predicted from psychophysical estimates of stereo threshold. Participants were instructed to pass a metal loop around a wire convoluted in depth. Error rate and speed were measured in 26 controls, 30 cases with keratoconus with best-corrected spectacles, a subset of 17 cases with rigid contact lenses, and 10 uncorrected myopes with acuity and stereo thresholds comparable to the keratoconic cohort. Stereo thresholds were determined using random-dot stimuli. Binocular error rates were lower than monocular error rates for controls, uncorrected myopes, and the better-performing half of cases (p < 0.001, for each), but not for the worst-performing half (p = 0.07). Error rates in cases improved with contact lenses (p < 0.001). Within each cohort, the error rate was poorly correlated with the stereo threshold (r2 < 0.12, for each). Monocular speeds were significantly lower than binocular speeds for controls than for cases (p = 0.003) and for uncorrected myopes than cases (p = 0.001). Degraded binocularity in keratoconus may limit the ability to perform depth-related visuomotor tasks. A portion of this loss may be overcome by using rigid contact lenses. The attributes of visuomotor task performance are, however, not predictable from the psychophysical estimates of stereo thresholds.
- 2 December 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Letters
- Vol. 9 (1) , 1-4
Explainable XceptionNet-Based Keratoconus Detection Using Infrared Images and Edge Computing
Keratoconus is a progressive eye disease affecting the cornea, potentially leading to vision impairment. Early detection is crucial to prevent long-term damage. Artificial intelligence (AI) with edge computing can significantly aid in the early diagnosis of keratoconus by reducing the computation time and increasing diagnostic accuracy. In this letter, we utilize a customized explainable Xception network for keratoconus detection. For this clinical infrared (IR) images are obtained from hospital under defined protocol. The IR images are preprocessed and pupil regions are extracted. The extracted regions are applied to XceptionNet, and integrated gradient-weighted class activation maps (GradCAM) are obtained. Experiment are performed to evaluate the performance of the network. Results show that the proposed approach is able to detect keratoconus images. The proposed approach yielded the average accuracy of 85%. GradCAM outcomes show that the trained model detected the regions similar to clinical interpretation. We assess the model's performance on an edge device, demonstrating its potential for real-time, on-site diagnostics. This application not only improves classification accuracy but also enhances interpretability, thereby assisting ophthalmologists in making informed decisions with greater confidence. Thus, the proposed architecture could be useful in clinical condition.
- 2 December 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Letters
- Vol. 9 (1) , 1-4
Explainable XceptionNet-Based Keratoconus Detection Using Infrared Images and Edge Computing
Keratoconus is a progressive eye disease affecting the cornea, potentially leading to vision impairment. Early detection is crucial to prevent long-term damage. Artificial intelligence (AI) with edge computing can significantly aid in the early diagnosis of keratoconus by reducing the computation time and increasing diagnostic accuracy. In this letter, we utilize a customized explainable Xception network for keratoconus detection. For this clinical infrared (IR) images are obtained from hospital under defined protocol. The IR images are preprocessed and pupil regions are extracted. The extracted regions are applied to XceptionNet, and integrated gradient-weighted class activation maps (GradCAM) are obtained. Experiment are performed to evaluate the performance of the network. Results show that the proposed approach is able to detect keratoconus images. The proposed approach yielded the average accuracy of 85%. GradCAM outcomes show that the trained model detected the regions similar to clinical interpretation. We assess the model's performance on an edge device, demonstrating its potential for real-time, on-site diagnostics. This application not only improves classification accuracy but also enhances interpretability, thereby assisting ophthalmologists in making informed decisions with greater confidence. Thus, the proposed architecture could be useful in clinical condition.