HAHazem Abouelleil

Hazem Abouelleil

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Hazem Abouelleil has a total of 34 co-authors. Here are the top co-authors by number of shared publications:

  • Brigitte Grosgogeat

    Faculté d’Odontologie, University Claude Bernard Lyon 1, 69100 Lyon, France

    5 shared publications
  • Nina Attik

    Universite Claude Bernard Lyon 1, Laboratoire des Multimatériaux et Interfaces (LMI) UMR 5615, Villeurbanne, France

    4 shared publications
  • Dominique Decoret

    UFR Odontologie, Université Lyon1, Lyon, France

    2 shared publications
  • Dominique Seux

    Universite Lyon1, Laboratoire des Multimatériaux et Interfaces, UMR CNRS 5615, Villeurbanne, France; UFR Odontologie, Université Lyon1, Lyon, France

    2 shared publications
  • Fatima Zohra Cherchali

    Laboratoire des Multimatériaux et Interfaces UMR CNRS 5615, Univ Lyon Université Claude Bernard Lyon 1 Villeurbanne France

    2 shared publications
  • Mohamed Mouzali

    Laboratoire de Synthèse Macromoléculaire et Thio-organique Macromoléculaire, Faculté de Chimie, Université des Sciences et de la Technologie Houari Boumediene, BP 32 El Alia, BabEzzouar, Alger, Algeria

    2 shared publications

Latest Publications

  • Open Access

    Effects of low-pressure non-thermal oxygen plasma treatments on mechanical properties of a PMMA resin for denture base

    by Christina Maillet, Damien Bureau, Yessine Toumi, Frédéric Velard, Hazem Abouelleil, Sophie C. Gangloff, Marie-Paule Gelle

    Aim To evaluate the mechanical properties of a denture base resin after repeated exposure to an alternative disinfection treatment using low-pressure non-thermal oxygen plasma (O₂ NTP). Materials and methods For each assay, the resin (ProBase® Hot, Ivoclar) samples were prepared using the heat-compression mold technique. They were exposed to one or six low-pressure or O2 NTP treatments for 120 min (n = 10/group). Dimensional stability, surface hardness, flexural strength and elastic modulus were evaluated before and after low pressure and O2 NTP treatments. SEM was used to observe the effect of the different treatments on the samples. Statistical analyses were performed using Student’s t-test or one-way ANOVA followed by a Tukey’s post hoc test according to the Shapiro-Wilk test normal distribution analysis (p < 0.05). Results No adverse effects on the dimensional stability and surface hardness were noted after repeated O2 NTP treatments. Flexural strength and elastic modulus were not significantly altered only if the resin was dehydrated under the controlled dry condition of this study. Indeed, SEM images revealed cracks on the samples surfaces only when moisture remained in the resin prior to plasma exposure. Conclusion O2 NTP could be a promising alternative approach to disinfect dentures, provided the resin’s hydration state is strictly controlled.

  • Merlon machinability and mechanical properties of four CAD/CAM block materials

    by Nina Attik, Pierre Colon, Brigitte Grosgogeat, Fatma Zohra Cherchali, Hazem Abouelleil

    The mechanical properties and machinability of CAD/CAM materials are critical in determining their clinical applications. This study evaluated and compared the mechanical behavior and machinability of three composite‐based blocks: Cerasmart (CS), Lava Ultimate (LU), and Grandio Blocs (GR), with a ceramic‐based block, Initial LRF (IR). Flexural strength, flexural modulus, fracture toughness, and Vickers hardness were assessed following standardized ISO protocols. The machinability was tested using the Merlon fracture method (ISO 18675:2022), and machined margins were examined using scanning electron microscopy (SEM). One‐way ANOVA was performed for statistical analysis (α = 0.05). GR exhibited the highest flexural strength among the tested materials, while IR showed significantly higher flexural modulus and Vickers hardness than the other materials. CS showed the lowest fracture toughness values. SEM observations revealed clear differences in surface quality after machining, with the ceramic block IR displaying inferior edge integrity compared with the composite‐based blocks. All four materials demonstrated satisfactory machinability according to ISO standards. However, composite‐based blocks exhibited better edge quality compared with the leucite‐reinforced ceramic block. The findings indicate that composite‐based restorative materials may result in better adaptation at the dental margins in posterior restorations, whereas ceramic materials present greater hardness, making them particularly suitable for enamel replacement.


  • Integration of various forms of Salvadora Persica « Siwak » into dental composites: A pilot in vitro study

    by Fatma Zohra Cherchali, Nina Attik, Halima Meriem Issaadi, Hazem Abouelleil, Dominique Decoret, Amel Amirouche-Korichi, Mohamed Mouzali, Dominique Seux, Brigitte Grosgogeat


  • Experimental Investigation of Dental Composites Degradation After Early Water Exposure

    by Rémy Gauthier, Hazem Abouelleil, Yoan Boussès, Nathalie Brulat-Bouchard, Pierre Colon, Jean-Marc Chenal, Yannick Tillier, Brigitte Grosgogeat

    While dental composite long-term aging has already been studied in the past, no data exist about the early aging while it might be detrimental regarding the composites' longevity. This study aims to better understand the effects of early water exposure on dental composites. Dental resin composites with different fillers ratio were subjected to water exposure during 24 h, 1 week, or 1 month. After photopolymerization, the samples were stored at different conditions, whether in wet or dry condition (W, D, respectively) and in wet conditions after a first 24 h storage in dry conditions (DW). Three-point bending tests were performed to measure the flexural modulus. The samples were then subjected to a sorption/desorption protocol. While the matrix alone did not undergo any mechanical degradation with exposure time, the composites matrices presented a decrease in elastic modulus. This decrease was the highest for the matrix with nonsilanized fillers. Interestingly, the DW condition was detrimental for all the samples. Regarding the sample with nonsilanized fillers in DW for 1 month presented an elastic modulus lower than the matrix alone. These results were assigned to the sorption capacity of the polymer matrix, suggesting that the diffusion mechanisms and the nature of water molecules are determinant in the composite degradation. This study showed that dental composite early degradation mechanisms after water exposure are involved in the polymer matrix postpolymerization process as soon as after 24 h. Such mechanisms are detrimental in terms of the dental composite efficiency and have to be understood.


  • Open Access

    Comparison of the Biological Behavior and Topographical Surface Assessment of a Minimally Invasive Dental Implant and a Standard Implant: An In Vitro Study

    by Nina Attik, Marina Phantarasmy, Hazem Abouelleil, Charlène Chevalier, Aurore Barraco, Brigitte Grosgogeat, Arnaud Lafon

    The current study aimed to assess the topographical and physical properties of a minimally invasive implant (MagiCore®: MC®, InnosBioSurg, IBS) and to evaluate its biological behavior compared to a gold standard implant (NobelParallel™: NB™, Nobel Biocare™). After surface characterization, the biological behavior assessment was conducted regarding human gingival fibroblasts (hGF) and osteoblast-like cells (MG63). Roughness values for NBTM were Ra = 1.28 µm and for MC® they were Ra = 2.02 µm. Alamar BlueTM assay LIVE/DEADTM staining results indicated equivalent biological development regarding both cell types for the two implants. Significant enhancement was found for hGF ALP activity in the presence of the two tested implants in a time-dependent manner from day 7 to day 14 (** p < 0.01). Alizarin red staining demonstrated significant calcium deposition enhancement when cells were interfaced with the NB™ compared to the MC® implant (** p < 0.05). Moreover, SEM and confocal imaging revealed good cell adhesion with a denser cellular layer on the MC® than the NB™ surface. The MC® cytocompatibility was ranked as equivalent to the gold standard implant despite the surface properties differences. These findings provide new insights about the minimally invasive implant’s biological behavior and its potential clinical implication in different implantology situations.


  • Impact of the Microstructure of CAD/CAM Blocks on the Bonding Strength and the Bonded Interface

    by Hazem Abouelleil, Pierre Colon, Christophe Jeannin, Alexis Goujat, Nina Attik, Laurent Laforest, Remy Gauthier, Brigitte Grosgogeat

    Purpose: To investigate the relationship between the microstructure of CAD/CAM blocks and the quality of adhesion as function of the surface treatment and resin cement type.Materials and methods: Two nano‐ceramic composite resin CAD/CAM blocks, Lava Ultimate (LU) and Cerasmart (CS), and two Leucite‐reinforced glass ceramic CAD/CAM IPS blocks, Empress® CAD (EM) and InitialTM LRF (IR), received either Hydrofluoric acid (HF) or sandblasting (SB) surface treatments. The blocks were then luted using two dual‐cure resin cements, LinkForce (LF) and Multilink Automix (ML) with their corresponding silanes, resulting in 16 study groups. The luted blocks were then thermal‐cycling (TC) for 5000 cycles and subjected to a microtensile bond strength (μTBS) test. Scanning electron microscopy (SEM) micrographs of the treated surfaces were analyzed using ImageJ software and XRD analyses were performed for the two ceramic blocks. The data obtained were submitted to Games‐Howell post‐hoc nonparametric test to compare combinations of groups or treatments and a linear mixed‐effects model for the factors surface treatment, block type, and resin cement, together with their first‐degree interactions (α = 0.05).Results: The lowest mean μTBS values were obtained with LU‐HF, whereas the highest mean μTBS values were obtained with CS regardless of resin cement type and surface treatment method. IR‐HF mean μTBS were significantly higher than IR‐SB, EM‐SB, and EM‐HF. Analysis using ImageJ software demonstrated significant differences in the density and pore size after HF surface treatment.Conclusions: The specific microstructure of each block material within the same family group impacted the micromechanical retention and the bonded interface strength.


  • Structural stability of DHMAI antibacterial dental composite following in vitro biological aging

    by Fatima Zohra Cherchali, Nina Attik, Mohamed Mouzali, Jean Bernard Tommasino, Hazem Abouelleil, Dominique Decoret, Dominique Seux, Brigitte Grosgogeat