Yi Zhao
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Yi Zhao has a total of 20 co-authors. Here are the top co-authors by number of shared publications:
- Guirong Yan
Missouri University of Science and Technology, Rolla, USA
2 shared publications John W. van de Lindt
2 shared publications- Arindam Gan Chowdhury
Florida International Univ
1 shared publication Cassandra A. Shivers-Williams
Social Science Deputy Program Manager, Weather Program Office, National Oceanic and Atmospheric Administration, 1315 East-West Highway, Silver Spring, MD 20910; Cooperative Institute for Severe and High-Impact Weather Research and Operations, Norman, OK 73072; National Severe Storms Laboratory, National Oceanic and Atmospheric Administration, Norman, OK 73072
1 shared publicationDaphne S. LaDue
Senior Research Scientist, Center for Analysis and Prediction of Storms, Univ. of Oklahoma, Norman, OK 73072
1 shared publicationGrace Yan
1 shared publication
Latest Publications
- Open Access
- 1 September 2025
- Published by KEAI Publishing in Advances in Wind Engineering
- Vol. 2 (3)
Understanding the relationship between structural failure and fatalities in Tornadoes: A quantitative investigation of the 2021 Midwest Tornado Outbreak
- 1 September 2025
- Published by KEAI Publishing in Advances in Wind Engineering
- Vol. 2 (3)
Open AccessUnderstanding the relationship between structural failure and fatalities in Tornadoes: A quantitative investigation of the 2021 Midwest Tornado Outbreak
- 1 December 2023
- Published by American Society of Civil Engineers (ASCE) in Journal of Structural Engineering
- Vol. 149 (12)
Understanding Tornadic Wind Effects on Manufactured or Mobile Homes through High-Fidelity CFD Simulations
- 1 December 2023
- Published by American Society of Civil Engineers (ASCE) in Journal of Structural Engineering
- Vol. 149 (12)
Understanding Tornadic Wind Effects on Manufactured or Mobile Homes through High-Fidelity CFD Simulations
- Open Access
- 5 March 2023
- Published by MDPI AG in Sustainability
- Vol. 15 (5) , 4635
Wind Effects on Dome Structures and Evaluation of CFD Simulations through Wind Tunnel Testing
In the study, a series of wind tunnel tests were conducted to investigate wind effects acting on dome structures (1/60 scale) induced by straight-line winds at a Reynolds number in the order of 106. Computational Fluid Dynamics (CFD) simulations were performed as well, including a Large Eddy Simulation (LES) and Reynolds-Averaged Navier–Stokes (RANS) simulation, and their performances were validated by a comparison with the wind tunnel testing data. It is concluded that wind loads generally increase with upstream wind velocities, and they are reduced over suburban terrain due to ground friction. The maximum positive pressure normally occurs near the base of the dome on the windward side caused by the stagnation area and divergence of streamlines. The minimum suction pressure occurs at the apex of the dome because of the blockage of the dome and convergence of streamlines. Suction force is the most significant among all wind loads, and special attention should be paid to the roof design for proper wind resistance. Numerical simulations also indicate that LES results match better with the wind tunnel testing in terms of the distribution pattern of the mean pressure coefficient on the dome surface and total suction force. The mean and root-mean-square errors of the meridian pressure coefficient associated with the LES are about 60% less than those associated with RANS results, and the error of suction force is about 40–70% less. Moreover, the LES is more accurate in predicting the location of boundary layer separation and reproducing the complex flow field behind the dome, and is superior in simulating vortex structures around the dome to further understand the unsteadiness and dynamics in the flow field.
- 5 March 2023
- Published by MDPI AG in Sustainability
- Vol. 15 (5) , 4635
Open AccessWind Effects on Dome Structures and Evaluation of CFD Simulations through Wind Tunnel Testing
In the study, a series of wind tunnel tests were conducted to investigate wind effects acting on dome structures (1/60 scale) induced by straight-line winds at a Reynolds number in the order of 106. Computational Fluid Dynamics (CFD) simulations were performed as well, including a Large Eddy Simulation (LES) and Reynolds-Averaged Navier–Stokes (RANS) simulation, and their performances were validated by a comparison with the wind tunnel testing data. It is concluded that wind loads generally increase with upstream wind velocities, and they are reduced over suburban terrain due to ground friction. The maximum positive pressure normally occurs near the base of the dome on the windward side caused by the stagnation area and divergence of streamlines. The minimum suction pressure occurs at the apex of the dome because of the blockage of the dome and convergence of streamlines. Suction force is the most significant among all wind loads, and special attention should be paid to the roof design for proper wind resistance. Numerical simulations also indicate that LES results match better with the wind tunnel testing in terms of the distribution pattern of the mean pressure coefficient on the dome surface and total suction force. The mean and root-mean-square errors of the meridian pressure coefficient associated with the LES are about 60% less than those associated with RANS results, and the error of suction force is about 40–70% less. Moreover, the LES is more accurate in predicting the location of boundary layer separation and reproducing the complex flow field behind the dome, and is superior in simulating vortex structures around the dome to further understand the unsteadiness and dynamics in the flow field.
- 16 August 2022
- Published by SAGE Publications in Advances in Structural Engineering
- Vol. 26 (1) , 89-107
Influence of swirl ratio and radial Reynolds number on wind characteristics of multi-vortex tornadoes
In this study, systematic numerical simulations are conducted to investigate how swirl ratio and radial Reynolds number affect the wind characteristics of multi-vortex tornadoes. By properly controlling boundary conditions, multi-vortex tornadoes are produced in a cylindrical computational domain. Six cases with different swirl ratios are studied to examine the influence of swirl ratio, while five cases with different radial Reynolds number are studied to investigate the influence of radial Reynolds number. To facilitate the characterization, the core size and rotational speed of subvortices, as well as the relative distance between the subvortex and the core radius of the main vortex, are defined. The results demonstrate that the increase in swirl ratio leads to the increase in the number of subvortices. For the overall vortex, the increase in swirl ratio decreases the maximum tangential velocity but increases the core radius of the overall flow. For subvortices, for the case where four subvortices are produced, the increase in swirl ratio increases the core size of subvortices but decreases the rotational speed of subvortices. While the increase in radial Reynolds number does not change the number of subvortices produced, it decreases the core size of subvortices, but increases the rotational speed of each subvortex.
- 16 August 2022
- Published by SAGE Publications in Advances in Structural Engineering
- Vol. 26 (1) , 89-107
Influence of swirl ratio and radial Reynolds number on wind characteristics of multi-vortex tornadoes
In this study, systematic numerical simulations are conducted to investigate how swirl ratio and radial Reynolds number affect the wind characteristics of multi-vortex tornadoes. By properly controlling boundary conditions, multi-vortex tornadoes are produced in a cylindrical computational domain. Six cases with different swirl ratios are studied to examine the influence of swirl ratio, while five cases with different radial Reynolds number are studied to investigate the influence of radial Reynolds number. To facilitate the characterization, the core size and rotational speed of subvortices, as well as the relative distance between the subvortex and the core radius of the main vortex, are defined. The results demonstrate that the increase in swirl ratio leads to the increase in the number of subvortices. For the overall vortex, the increase in swirl ratio decreases the maximum tangential velocity but increases the core radius of the overall flow. For subvortices, for the case where four subvortices are produced, the increase in swirl ratio increases the core size of subvortices but decreases the rotational speed of subvortices. While the increase in radial Reynolds number does not change the number of subvortices produced, it decreases the core size of subvortices, but increases the rotational speed of each subvortex.
- 1 August 2021
- Published by American Society of Civil Engineers (ASCE) in Natural Hazards Review
- Vol. 22 (3) , 04021015
Wind Flow Characteristics of Multivortex Tornadoes
A multivortex tornado refers to a tornado that contains two or more small subvortices in the wind field. Due to the presence of multiple vortices, this type of tornado is likely to be more dangerous and destructive than single-vortex tornadoes. To understand the action of the multivortex tornado on civil structures, the wind flow characteristics are investigated and compared with those of single-vortex tornadoes, by using computational fluid dynamics (CFD) simulations. The results show that the inner flow structure of a multivortex tornado is completely different from that of a single-vortex tornado. First, a multivortex tornado possesses more than one subvortex in the domain around the core radius of the main vortex, and each subvortex flows together with the main vortex while rotating around its own center. Second, the wind flow of a multivortex tornado is more turbulent than a single-vortex tornado, which may lead to significant dynamic responses in some types of civil structures. Third, the maximum negative pressure occurs at the center of each subvortex instead of the center of the main vortex, which means that the largest negative pressure and highest wind speed occur at the same location. This unique feature in the multivortex tornado leads to different worst loading scenarios from single-vortex tornadoes and the worst-case scenario might be the combination of high tangential velocity and high negative pressure around the core radius. Fourth, for a multivortex tornado, the difference between instantaneous values and space-averaged values of parameters is remarkable. Thus, the space-averaged values should be carefully used for determining design tornadic wind loads for civil structures.
- 1 August 2021
- Published by American Society of Civil Engineers (ASCE) in Natural Hazards Review
- Vol. 22 (3) , 04021015
Wind Flow Characteristics of Multivortex Tornadoes
A multivortex tornado refers to a tornado that contains two or more small subvortices in the wind field. Due to the presence of multiple vortices, this type of tornado is likely to be more dangerous and destructive than single-vortex tornadoes. To understand the action of the multivortex tornado on civil structures, the wind flow characteristics are investigated and compared with those of single-vortex tornadoes, by using computational fluid dynamics (CFD) simulations. The results show that the inner flow structure of a multivortex tornado is completely different from that of a single-vortex tornado. First, a multivortex tornado possesses more than one subvortex in the domain around the core radius of the main vortex, and each subvortex flows together with the main vortex while rotating around its own center. Second, the wind flow of a multivortex tornado is more turbulent than a single-vortex tornado, which may lead to significant dynamic responses in some types of civil structures. Third, the maximum negative pressure occurs at the center of each subvortex instead of the center of the main vortex, which means that the largest negative pressure and highest wind speed occur at the same location. This unique feature in the multivortex tornado leads to different worst loading scenarios from single-vortex tornadoes and the worst-case scenario might be the combination of high tangential velocity and high negative pressure around the core radius. Fourth, for a multivortex tornado, the difference between instantaneous values and space-averaged values of parameters is remarkable. Thus, the space-averaged values should be carefully used for determining design tornadic wind loads for civil structures.