Chengshun Yang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Chengshun Yang has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
- Dongdong Zhang
School of Electric Power Engineering, Nanjing Institute of Technology, Nanjing 211167, China
2 shared publications - Tao Hua
School of Electric Power Engineering, Nanjing Institute of Technology, Nanjing, China
2 shared publications - Yuchen Dai
College of Engineering, Zhejiang Normal University, Jinhua 321004, China
2 shared publications - Dongdong Zhang
School of Electric Power Engineering, Nanjing Institute of Technology, Nanjing, China
1 shared publication Guofu Liu
School of Electric Power Engineering, Nanjing Institute of Technology, Nanjing 211167, China
1 shared publication- Hong Xu
School of Electric Power Engineering, Nanjing Institute of Technology, Nanjing, China
1 shared publication
Latest Publications
- 1 September 2022
- Published by Springer Nature in Journal of Electrical Engineering & Technology
- Vol. 18 (3) , 1919-1930
Second-Order Nonlinear Disturbance Observer Based Adaptive Disturbance Rejection Control for PMSM in Electric Vehicles
- 1 September 2022
- Published by Springer Nature in Journal of Electrical Engineering & Technology
- Vol. 18 (3) , 1919-1930
Second-Order Nonlinear Disturbance Observer Based Adaptive Disturbance Rejection Control for PMSM in Electric Vehicles
- Open Access
- 3 February 2022
- Published by Wiley in Mathematical Problems in Engineering
- Vol. 2022, 1-12
Disturbance-Observer-Based Adaptive Fuzzy Control for Islanded Distributed Energy Resource Systems
With the aim to improve the antidisturbance ability of the islanded distributed energy resource (DER) systems, a disturbance-observer-based adaptive fuzzy sliding mode control (DAFSC) voltage controller is designed based on indirect vector control, which implements the voltage tracking and improves the self-regulation ability of the islanded DER systems. Firstly, the circuit diagram and the mathematical model of the DER system are presented. Then, the second-order sliding mode differentiator is designed to solve the problem of calculation expansion in the backstepping control method. To solve the influence of lumped disturbance on the system, a disturbance-observer is proposed to observe the unknown disturbance and compensate the controller feed-forward. Moreover, fuzzy control is proposed to reduce the dependence of the control effect on model accuracy. Finally, the stability of the controller is verified by Lyapunov stability theory, and the hardware in the loop results is given to verify that the control effect of the proposed DAFC controller has better dynamic performance compared with proportion-integral (PI) and the backstepping control strategy.
- 3 February 2022
- Published by Wiley in Mathematical Problems in Engineering
- Vol. 2022, 1-12
Open AccessDisturbance-Observer-Based Adaptive Fuzzy Control for Islanded Distributed Energy Resource Systems
With the aim to improve the antidisturbance ability of the islanded distributed energy resource (DER) systems, a disturbance-observer-based adaptive fuzzy sliding mode control (DAFSC) voltage controller is designed based on indirect vector control, which implements the voltage tracking and improves the self-regulation ability of the islanded DER systems. Firstly, the circuit diagram and the mathematical model of the DER system are presented. Then, the second-order sliding mode differentiator is designed to solve the problem of calculation expansion in the backstepping control method. To solve the influence of lumped disturbance on the system, a disturbance-observer is proposed to observe the unknown disturbance and compensate the controller feed-forward. Moreover, fuzzy control is proposed to reduce the dependence of the control effect on model accuracy. Finally, the stability of the controller is verified by Lyapunov stability theory, and the hardware in the loop results is given to verify that the control effect of the proposed DAFC controller has better dynamic performance compared with proportion-integral (PI) and the backstepping control strategy.
- Open Access
Research on the Non-Contact Pollution Monitoring Method of Composite Insulator Based on Space Electric Field
Through spatial electric field monitoring, it is expected to realize insulator pollution condition monitoring and contamination flashover warning in a non-contact way. Therefore, in this paper, the spatial electric field distribution characteristics of 110 kV composite insulators are simulated, where the effects of different surface states and their discharge levels on the spatial electric field of insulators are analyzed. On this basis, a non-contact monitoring method for composite insulator pollution based on the spatial electric field is proposed. The results show that there are significant differences in the spatial electric field of the composite insulator among three conditions, namely cleaning, pollution layer wetting, and dry band arcing. Increases of pollution layer wetting and dry band arcing would lead to an increase of the amplitude of the spatial electric field of the insulator. Verification experiments well indicated that it is feasible to identify the degree of pollution layer wetting as well as dry band arcing of the insulator string by fixed-point monitoring, the spatial electric field signal at the cross-strand of d = 0.5 m and directly opposite the last three positions. Research results can provide references for the online monitoring of overhead line polluted insulators and its flashover warning.
Open AccessResearch on the Non-Contact Pollution Monitoring Method of Composite Insulator Based on Space Electric Field
Through spatial electric field monitoring, it is expected to realize insulator pollution condition monitoring and contamination flashover warning in a non-contact way. Therefore, in this paper, the spatial electric field distribution characteristics of 110 kV composite insulators are simulated, where the effects of different surface states and their discharge levels on the spatial electric field of insulators are analyzed. On this basis, a non-contact monitoring method for composite insulator pollution based on the spatial electric field is proposed. The results show that there are significant differences in the spatial electric field of the composite insulator among three conditions, namely cleaning, pollution layer wetting, and dry band arcing. Increases of pollution layer wetting and dry band arcing would lead to an increase of the amplitude of the spatial electric field of the insulator. Verification experiments well indicated that it is feasible to identify the degree of pollution layer wetting as well as dry band arcing of the insulator string by fixed-point monitoring, the spatial electric field signal at the cross-strand of d = 0.5 m and directly opposite the last three positions. Research results can provide references for the online monitoring of overhead line polluted insulators and its flashover warning.