CYChengshun Yang

Chengshun Yang

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Chengshun Yang has a total of 12 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Disturbance-Observer-Based Adaptive Fuzzy Control for Islanded Distributed Energy Resource Systems

    by Chengshun Yang, Tao Hua, Yuchen Dai, Guofu Liu, Xiaoning Huang, Dongdong Zhang

    With the aim to improve the antidisturbance ability of the islanded distributed energy resource (DER) systems, a disturbance-observer-based adaptive fuzzy sliding mode control (DAFSC) voltage controller is designed based on indirect vector control, which implements the voltage tracking and improves the self-regulation ability of the islanded DER systems. Firstly, the circuit diagram and the mathematical model of the DER system are presented. Then, the second-order sliding mode differentiator is designed to solve the problem of calculation expansion in the backstepping control method. To solve the influence of lumped disturbance on the system, a disturbance-observer is proposed to observe the unknown disturbance and compensate the controller feed-forward. Moreover, fuzzy control is proposed to reduce the dependence of the control effect on model accuracy. Finally, the stability of the controller is verified by Lyapunov stability theory, and the hardware in the loop results is given to verify that the control effect of the proposed DAFC controller has better dynamic performance compared with proportion-integral (PI) and the backstepping control strategy.


  • Open Access

    Research on the Non-Contact Pollution Monitoring Method of Composite Insulator Based on Space Electric Field

    by Dongdong Zhang, Hong Xu, Jin Liu, Chengshun Yang, Xiaoning Huang, Zhijin Zhang, Xingliang Jiang

    Through spatial electric field monitoring, it is expected to realize insulator pollution condition monitoring and contamination flashover warning in a non-contact way. Therefore, in this paper, the spatial electric field distribution characteristics of 110 kV composite insulators are simulated, where the effects of different surface states and their discharge levels on the spatial electric field of insulators are analyzed. On this basis, a non-contact monitoring method for composite insulator pollution based on the spatial electric field is proposed. The results show that there are significant differences in the spatial electric field of the composite insulator among three conditions, namely cleaning, pollution layer wetting, and dry band arcing. Increases of pollution layer wetting and dry band arcing would lead to an increase of the amplitude of the spatial electric field of the insulator. Verification experiments well indicated that it is feasible to identify the degree of pollution layer wetting as well as dry band arcing of the insulator string by fixed-point monitoring, the spatial electric field signal at the cross-strand of d = 0.5 m and directly opposite the last three positions. Research results can provide references for the online monitoring of overhead line polluted insulators and its flashover warning.