Yunqing Liu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Yunqing Liu has a total of 21 co-authors. Here are the top co-authors by number of shared publications:
- Chengjin Qin
Shanghai Jiao Tong University
4 shared publications - Chengliang Liu
Shanghai Jiao Tong University
3 shared publications - Jinlei Liu
School of Mechanical Engineering, Shanghai Jiao Tong University, Shanghai, China
3 shared publications - Zhiyuan Li
Shanghai Jiao Tong University
3 shared publications - Yanrui Jin
State Key Laboratory of Mechanical System and Vibration, School of Mechanical Engineering, Shanghai Jiao Tong University, Shanghai 200240, China
2 shared publications - Aijun He
School of Art and Design, LanZhou JiaoTong University, LanZhou, China
1 shared publication
Latest Publications
- 1 January 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 73 (00189456) , 1-17
Lightweight Optimization of Deep Learning Models for Accurate Arrhythmia Detection in Clinical 12-Lead ECG Data
Although significant progress has been made in diagnosing arrhythmias, current deep neural network (DNN)-based methods still suffer from misdiagnosis and redundant parameters. One reason for this is the lack of high-quality clinical 12-lead Electrocardiogram (ECG) data sets and the absence of a systematic set of general task-oriented network lightweight methods. The objective of this paper is to propose a lightweight optimization method of deep learning models for accurate arrhythmia detection in clinical 12-lead ECG data. We show that the proposed optimized module replacement method can provide a strategy for arrhythmia detection in the lightweight network design for clinical 12-lead classification. The key of this method is to design compact convolution to replace standard convolutions based on module functional equivalence and identify the accuracy fractured segment (AFS). To achieve this, we randomly choose a network base (the initial model) that achieves satisfactory classification performance on a given classification task, replace larger-scale parameter convolutions with smaller-scale parameter convolutions, observe the degenerated process of accuracy until an AFS is found, and conduct tests in the candidate models. We validate the proposed method against the 3-year 12-lead ECGs of patients who have undergone ECG detection at Shanghai First People’s Hospital and achieve an overall accuracy of 95.532%, a precision score of 0.927, a recall score of 0.910, and a specificity score of 0.990, which are better than other methods. The comparative analysis shows that the proposed method can not only effectively reduce network parameters but also boost model performance for specific classification tasks.
- 1 January 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 73 (00189456) , 1-17
Lightweight Optimization of Deep Learning Models for Accurate Arrhythmia Detection in Clinical 12-Lead ECG Data
Although significant progress has been made in diagnosing arrhythmias, current deep neural network (DNN)-based methods still suffer from misdiagnosis and redundant parameters. One reason for this is the lack of high-quality clinical 12-lead Electrocardiogram (ECG) data sets and the absence of a systematic set of general task-oriented network lightweight methods. The objective of this paper is to propose a lightweight optimization method of deep learning models for accurate arrhythmia detection in clinical 12-lead ECG data. We show that the proposed optimized module replacement method can provide a strategy for arrhythmia detection in the lightweight network design for clinical 12-lead classification. The key of this method is to design compact convolution to replace standard convolutions based on module functional equivalence and identify the accuracy fractured segment (AFS). To achieve this, we randomly choose a network base (the initial model) that achieves satisfactory classification performance on a given classification task, replace larger-scale parameter convolutions with smaller-scale parameter convolutions, observe the degenerated process of accuracy until an AFS is found, and conduct tests in the candidate models. We validate the proposed method against the 3-year 12-lead ECGs of patients who have undergone ECG detection at Shanghai First People’s Hospital and achieve an overall accuracy of 95.532%, a precision score of 0.927, a recall score of 0.910, and a specificity score of 0.990, which are better than other methods. The comparative analysis shows that the proposed method can not only effectively reduce network parameters but also boost model performance for specific classification tasks.
- 17 May 2022
- Published by Elsevier in Knowledge-Based Systems
- Vol. 250
An efficient neural network-based method for patient-specific information involved arrhythmia detection
- 17 May 2022
- Published by Elsevier in Knowledge-Based Systems
- Vol. 250
An efficient neural network-based method for patient-specific information involved arrhythmia detection
- 1 January 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 71 (00189456) , 1-11
A Novel Interpretable Method Based on Dual-Level Attentional Deep Neural Network for Actual Multilabel Arrhythmia Detection
Arrhythmia accounts for more than 80% of sudden cardiac death, and its incidence rate has increased rapidly recently. Nowadays, many studies have applied artificial intelligence (AI) methods to arrhythmia detection. Deep learning approaches can improve model performance but lack the capability to mine the relationship between the electrocardiogram (ECG) samples and final results. Furthermore, most arrhythmia diagnosis methods aim at only multiclassification problems. However, in many cases, an ECG recording may have more than one arrhythmia disease. In this article, we develop an accurate and interpretable model for multilabel ECG signals, which is called dual-level attentional convolutional long short-term memory neural network (DLA-CLSTM). Convolutional layers, bidirectional long short-term memory layers, and attention mechanisms are used for extracting beat- and rhythm-level information. Notably, the attention mechanism helps the model be more interpretable. In addition, we design a weighted multilabel classifier to address multilabel and imbalance problems. Finally, the MIT-BIH Arrhythmia Database and the 1st China Physiological Signal Challenge dataset are utilized to evaluate DLA-CLSTM. Compared with existing methods, DLA-CLSTM can improve the accuracy by 22.50% and the F1-macro by 20.51% on average. Further analysis shows that the areas focused by DLA-CLSTM match the clinical judgment basis to some extent. Collectively, DLA-CLSTM has good potential for assisting clinicians in real applications.
- 1 January 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 71 (00189456) , 1-11
A Novel Interpretable Method Based on Dual-Level Attentional Deep Neural Network for Actual Multilabel Arrhythmia Detection
Arrhythmia accounts for more than 80% of sudden cardiac death, and its incidence rate has increased rapidly recently. Nowadays, many studies have applied artificial intelligence (AI) methods to arrhythmia detection. Deep learning approaches can improve model performance but lack the capability to mine the relationship between the electrocardiogram (ECG) samples and final results. Furthermore, most arrhythmia diagnosis methods aim at only multiclassification problems. However, in many cases, an ECG recording may have more than one arrhythmia disease. In this article, we develop an accurate and interpretable model for multilabel ECG signals, which is called dual-level attentional convolutional long short-term memory neural network (DLA-CLSTM). Convolutional layers, bidirectional long short-term memory layers, and attention mechanisms are used for extracting beat- and rhythm-level information. Notably, the attention mechanism helps the model be more interpretable. In addition, we design a weighted multilabel classifier to address multilabel and imbalance problems. Finally, the MIT-BIH Arrhythmia Database and the 1st China Physiological Signal Challenge dataset are utilized to evaluate DLA-CLSTM. Compared with existing methods, DLA-CLSTM can improve the accuracy by 22.50% and the F1-macro by 20.51% on average. Further analysis shows that the areas focused by DLA-CLSTM match the clinical judgment basis to some extent. Collectively, DLA-CLSTM has good potential for assisting clinicians in real applications.
- 1 January 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 70 (00189456) , 1-12
A Novel Incremental and Interactive Method for Actual Heartbeat Classification With Limited Additional Labeled Samples
In the actual scenario, it is difficult for an automatic diagnosis system to detect each heartbeat when facing new patients. In this article, a novel active dual-scale residual convolutional long short-term memory neural network is proposed to classify heartbeats interactively and automatically. First, each heartbeat and electrocardiogram segment including current heartbeat are combined to build dual-scale input information. In addition, convolution layers, residual block, and bidirectional long short memory are integrated to extract features from dual-scale inputs. Furthermore, active learning approach with random breaking-ties selection strategy is introduced to choose the most representative unlabeled samples for labeling and fine-tune the trained model with these representative labeled samples. The experimental results show that the proposed method uses only 5.14% of the additional data set and improves the model accuracy and macro F1 score by 13.23% and 35.62%, respectively. The proposed structure has good representative ability and our selection strategy can reduce the workload of experts and improve the performance greatly. Thus, the proposed interactive and incremental method has good potential in real applications.
- 1 January 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 70 (00189456) , 1-12
A Novel Incremental and Interactive Method for Actual Heartbeat Classification With Limited Additional Labeled Samples
In the actual scenario, it is difficult for an automatic diagnosis system to detect each heartbeat when facing new patients. In this article, a novel active dual-scale residual convolutional long short-term memory neural network is proposed to classify heartbeats interactively and automatically. First, each heartbeat and electrocardiogram segment including current heartbeat are combined to build dual-scale input information. In addition, convolution layers, residual block, and bidirectional long short memory are integrated to extract features from dual-scale inputs. Furthermore, active learning approach with random breaking-ties selection strategy is introduced to choose the most representative unlabeled samples for labeling and fine-tune the trained model with these representative labeled samples. The experimental results show that the proposed method uses only 5.14% of the additional data set and improves the model accuracy and macro F1 score by 13.23% and 35.62%, respectively. The proposed structure has good representative ability and our selection strategy can reduce the workload of experts and improve the performance greatly. Thus, the proposed interactive and incremental method has good potential in real applications.
- 17 October 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 681-685
A Real-Time Impedance Measurement System for EEG Based on Embedded System
The contact between the electrodes in the electroencephalogram (EEG) machine and the scalp has a great influence on the quality of the EEG. In order to guarantee the quality of the collected brain waves, we designed an embedded real-time impedance measurement system for the EEG. The system uses the ADS1299 chip, which depends on the on-chip current source to generate an alternating current which is higher than the frequency of the EEG signal as the output signal for impedance measurement. After A/D conversion, the obtained signals contain both EEG signals and impedance measurement signals. Furthermore, the system uses stm32f723 as the main control chip to design a filter to separate the two kinds of signals, and calculate the impedance value between the electrode and scalp in real time. In this system, the EEG signal and the impedance value data are stored in the SD card in BDF format at the same time, which provides the basis for judging the effective EEG data in the later signal processing. At the same time, the impedance value is compared with the preset threshold, and the LED is used to indicate whether the scalp is in good contact. Based on stm32F723 embedded system, the whole system has high integration, small volume, high measurement accuracy and strong real-time performance, which is of great significance for obtaining high-quality EEG data.
- 17 October 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 681-685
A Real-Time Impedance Measurement System for EEG Based on Embedded System
The contact between the electrodes in the electroencephalogram (EEG) machine and the scalp has a great influence on the quality of the EEG. In order to guarantee the quality of the collected brain waves, we designed an embedded real-time impedance measurement system for the EEG. The system uses the ADS1299 chip, which depends on the on-chip current source to generate an alternating current which is higher than the frequency of the EEG signal as the output signal for impedance measurement. After A/D conversion, the obtained signals contain both EEG signals and impedance measurement signals. Furthermore, the system uses stm32f723 as the main control chip to design a filter to separate the two kinds of signals, and calculate the impedance value between the electrode and scalp in real time. In this system, the EEG signal and the impedance value data are stored in the SD card in BDF format at the same time, which provides the basis for judging the effective EEG data in the later signal processing. At the same time, the impedance value is compared with the preset threshold, and the LED is used to indicate whether the scalp is in good contact. Based on stm32F723 embedded system, the whole system has high integration, small volume, high measurement accuracy and strong real-time performance, which is of great significance for obtaining high-quality EEG data.