Wenxia Ma
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Wenxia Ma has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
- Ai‐Fen Pan
Department of Anaesthesia Surgery The First Affiliated Hospital of Soochow University Suzhou City Jiangsu Province China
1 shared publication Haiying Wang
Department of Information The First Affiliated Hospital of Soochow University Suzhou City China
1 shared publicationJuanmei Fang
Department of Surgery The First Affiliated Hospital of Soochow University Suzhou City China
1 shared publication- Jun Huang
Departments of Orthopaedic Surgery (J.H., Z.Z., W.S., and J.L.), Clinical Pharmacology (Y.Z.), and Quality Management (W.M.), the First Affiliated Hospital of Soochow University, Suzhou, People’s Republic of China
1 shared publication - Jun Lin
The Fourth Affiliated Hospital of Soochow University, Suzhou Dushu Lake Hospital, Medical Center of Soochow University
1 shared publication Li Fan
Department of Surgery The First Affiliated Hospital of Soochow University Suzhou City China
1 shared publication
Latest Publications
- 10 April 2021
- Published by Wiley in International Journal of Nursing Practice
- Vol. 27 (4) , e12942
Risk factors for incorrect surgical count during surgery: An observational study
Background: Incorrect surgical counts are closely related to retained surgical items, which pose a threat to patients. However, the risk factors for incorrect surgical counts have not been identified yet.Aim: To identify the risk factors associated with incorrect surgical counts during surgery in a tertiary hospital.Design: An observational case–control study.Methods: Seventy cases of incorrect surgical counts were reviewed in this study. Data were collected from January 1, 2014, to April 4, 2019. For each case, we included four randomly selected control cases involving the same surgical procedures by the same surgeon within a 6‐month period for comparison. The medical data of these cases were extracted for further statistical analysis.Results: A higher incidence of incorrect surgical counts was observed among surgical counts performed between 8:00 a.m. to 12:00 a.m., emergency operations, prolonged procedures, and/or after addition of surgical items.Conclusion: Prolonged surgical procedures, emergency operations, time of occurrence, and addition of surgical items were the risk factors related to incorrect surgical counts during surgery.
- 10 April 2021
- Published by Wiley in International Journal of Nursing Practice
- Vol. 27 (4) , e12942
Risk factors for incorrect surgical count during surgery: An observational study
Background: Incorrect surgical counts are closely related to retained surgical items, which pose a threat to patients. However, the risk factors for incorrect surgical counts have not been identified yet.Aim: To identify the risk factors associated with incorrect surgical counts during surgery in a tertiary hospital.Design: An observational case–control study.Methods: Seventy cases of incorrect surgical counts were reviewed in this study. Data were collected from January 1, 2014, to April 4, 2019. For each case, we included four randomly selected control cases involving the same surgical procedures by the same surgeon within a 6‐month period for comparison. The medical data of these cases were extracted for further statistical analysis.Results: A higher incidence of incorrect surgical counts was observed among surgical counts performed between 8:00 a.m. to 12:00 a.m., emergency operations, prolonged procedures, and/or after addition of surgical items.Conclusion: Prolonged surgical procedures, emergency operations, time of occurrence, and addition of surgical items were the risk factors related to incorrect surgical counts during surgery.
- Open Access
- 1 January 2020
- Published by Wolters Kluwer Health in JBJS Open Access
- Vol. 5 (4) , e20.00078
A Novel Method for Accurate Preoperative Templating for Total Hip Arthroplasty Using a Biplanar Digital Radiographic (EOS) System
Background: Accurate preoperative planning for total hip arthroplasty (THA) relies on conventional anteroposterior radiographs. The difficulty of determining the magnification factor of radiographs is a major limitation. Despite the use of markers for calibration, identifying the plane of the hip joint is a major challenge. The aim of this study was to evaluate the accuracy of a novel method for image calibration and preoperative planning in THA involving the use of a biplanar radiographic (EOS imaging) system and a self-designed coin device. Methods: Biplanar radiographs (with the self-designed coin device) and a conventional anteroposterior radiograph (with a coin) were made for 26 patients after primary THA. The agreement between the actual and calculated diameters for each method was assessed using the concordance correlation coefficient (CCC) and Bland-Altman plots. In addition, 15 patients undergoing primary THA were prospectively enrolled to evaluate the EOS imaging-based method (EOS method), with biplanar radiographs made with use of the coin device. The accuracy of the preoperative predicted size of the implants was evaluated. Results: Both the EOS and conventional anteroposterior radiograph-based methods were reliable in repeated measurements of the diameter of the artificial femoral head in the reproducibility study, with the average CCCs for both methods >0.990. The agreement between the actual and EOS-based calculated diameters of the artificial femoral head was excellent, with a CCC of >0.990, while the agreement was poor between the actual and anteroposterior radiograph-based calculated diameters, with a CCC of <0.75. The EOS method exhibited a lower absolute difference (0.09 ± 0.07 mm) between the actual and calculated diameters compared with conventional anteroposterior radiography (1.26 ± 0.86 mm) (p < 0.001). EOS-based preoperative plans also exhibited excellent performance on the accuracy of the planning of the cups and stems; only 1 patient (6.7%) had a final implanted cup that differed by 1 size from the predicted size. Two patients (13.3%) had final implanted stems that differed by 1 size from the predicted size, and for 1 patient (6.7%), the stem size was off by ≥2 sizes. Conclusions: We describe a novel and easy-to-use method for the accurate calibration of radiographs and preoperative planning for THA. The EOS method evaluated in this study is an alternative method for preoperative planning in clinical practice.
- 1 January 2020
- Published by Wolters Kluwer Health in JBJS Open Access
- Vol. 5 (4) , e20.00078
Open AccessA Novel Method for Accurate Preoperative Templating for Total Hip Arthroplasty Using a Biplanar Digital Radiographic (EOS) System
Background: Accurate preoperative planning for total hip arthroplasty (THA) relies on conventional anteroposterior radiographs. The difficulty of determining the magnification factor of radiographs is a major limitation. Despite the use of markers for calibration, identifying the plane of the hip joint is a major challenge. The aim of this study was to evaluate the accuracy of a novel method for image calibration and preoperative planning in THA involving the use of a biplanar radiographic (EOS imaging) system and a self-designed coin device. Methods: Biplanar radiographs (with the self-designed coin device) and a conventional anteroposterior radiograph (with a coin) were made for 26 patients after primary THA. The agreement between the actual and calculated diameters for each method was assessed using the concordance correlation coefficient (CCC) and Bland-Altman plots. In addition, 15 patients undergoing primary THA were prospectively enrolled to evaluate the EOS imaging-based method (EOS method), with biplanar radiographs made with use of the coin device. The accuracy of the preoperative predicted size of the implants was evaluated. Results: Both the EOS and conventional anteroposterior radiograph-based methods were reliable in repeated measurements of the diameter of the artificial femoral head in the reproducibility study, with the average CCCs for both methods >0.990. The agreement between the actual and EOS-based calculated diameters of the artificial femoral head was excellent, with a CCC of >0.990, while the agreement was poor between the actual and anteroposterior radiograph-based calculated diameters, with a CCC of <0.75. The EOS method exhibited a lower absolute difference (0.09 ± 0.07 mm) between the actual and calculated diameters compared with conventional anteroposterior radiography (1.26 ± 0.86 mm) (p < 0.001). EOS-based preoperative plans also exhibited excellent performance on the accuracy of the planning of the cups and stems; only 1 patient (6.7%) had a final implanted cup that differed by 1 size from the predicted size. Two patients (13.3%) had final implanted stems that differed by 1 size from the predicted size, and for 1 patient (6.7%), the stem size was off by ≥2 sizes. Conclusions: We describe a novel and easy-to-use method for the accurate calibration of radiographs and preoperative planning for THA. The EOS method evaluated in this study is an alternative method for preoperative planning in clinical practice.