Peter Walker Ferguson
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Peter Walker Ferguson has a total of 21 co-authors. Here are the top co-authors by number of shared publications:
Jacob Rosen
Mechanical and Aerospace Engineering Department, University of California, USA
9 shared publications- Jacob Rosen
Department of Mechanical and Aerospace Engineering, University of California at Los Angeles, Los Angeles, CA, USA
5 shared publications - Ji Ma
Department of Mechanical and Aerospace Engineering, University of California at Los Angeles, Los Angeles, CA, USA
4 shared publications - Sahba Aghajani Pedram
Department of Mechanical and Aerospace Engineering, University of California, Los Angeles, CA, USA
4 shared publications - Yang Shen
UBTECH North America Research and Development Center, Pasadena, CA, USA
4 shared publications Changyeob Shin
3 shared publications
Latest Publications
- 5 July 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Robotics and Bionics
- Vol. 6 (3) , 1158-1169
On the OTHER Hand: A Bilateral, Reconfigurable Hand Exoskeleton With Opposable Thumbs for Use With Upper Limb Exoskeletons
This study aims to document the design of the OTHER Hand: a novel bilateral, reconfigurable, hand exoskeleton with opposable thumbs for use with upper limb exoskeletons. Intended for grasp research and rehabilitation with an emphasis on stroke, the OTHER Hand is designed as a one-size-fits-all system that can enable most of the common prehensile grasps and hand postures performed in activities of daily living. The capacity of the system to perform such grasps and postures is experimentally demonstrated by an average 94% normalized Grasping Ability Score across thirteen subjects using the Anthropomorphic Hand Assessment Protocol. This score demonstrates near-unhindered grasping performance for individuals without hand impairments wearing the OTHER Hand.
- 5 July 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Robotics and Bionics
- Vol. 6 (3) , 1158-1169
On the OTHER Hand: A Bilateral, Reconfigurable Hand Exoskeleton With Opposable Thumbs for Use With Upper Limb Exoskeletons
This study aims to document the design of the OTHER Hand: a novel bilateral, reconfigurable, hand exoskeleton with opposable thumbs for use with upper limb exoskeletons. Intended for grasp research and rehabilitation with an emphasis on stroke, the OTHER Hand is designed as a one-size-fits-all system that can enable most of the common prehensile grasps and hand postures performed in activities of daily living. The capacity of the system to perform such grasps and postures is experimentally demonstrated by an average 94% normalized Grasping Ability Score across thirteen subjects using the Anthropomorphic Hand Assessment Protocol. This score demonstrates near-unhindered grasping performance for individuals without hand impairments wearing the OTHER Hand.
- 1 September 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 69 (2) , 910-920
A Novel Tissue Identification Framework in Cataract Surgery Using an Integrated Bioimpedance-Based Probe and Machine Learning Algorithms
Objective: The objective of this work was to develop and experimentally validate a bioimpedance-based framework to identify tissues in contact with the surgical instrument during cataract surgery. Methods: This work introduces an integrated hardware and software solution based on the unique bioimpedance of different intraocular tissues. The developed hardware can be readily integrated with commonly used surgical instruments. The proposed software framework, which encompasses data acquisition and a machine-learning classifier, is fast enough to be deployed in real-time surgical interventions. The experimental protocol included bioimpedance data collected from 31 ex vivo pig eyes targeting four intraocular tissues: Iris , Cornea , Lens , and Vitreous . Results: A classifier based on a support vector machine exhibited an overall accuracy of 91% across all trials. The algorithm provided substantial performance in detecting the intraocular tissues with 100% reliability and 95% sensitivity for the lens, along with 88% reliability and 94% sensitivity for the vitreous. Conclusion: The developed impedance-based framework demonstrated successful intraocular tissue identification. Significance: Clinical implications include the ability to ensure safe operations by detecting posterior capsule rapture with 94% probability and improving surgical efficacy through lens detection with 100% reliability.
- 1 September 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 69 (2) , 910-920
A Novel Tissue Identification Framework in Cataract Surgery Using an Integrated Bioimpedance-Based Probe and Machine Learning Algorithms
Objective: The objective of this work was to develop and experimentally validate a bioimpedance-based framework to identify tissues in contact with the surgical instrument during cataract surgery. Methods: This work introduces an integrated hardware and software solution based on the unique bioimpedance of different intraocular tissues. The developed hardware can be readily integrated with commonly used surgical instruments. The proposed software framework, which encompasses data acquisition and a machine-learning classifier, is fast enough to be deployed in real-time surgical interventions. The experimental protocol included bioimpedance data collected from 31 ex vivo pig eyes targeting four intraocular tissues: Iris , Cornea , Lens , and Vitreous . Results: A classifier based on a support vector machine exhibited an overall accuracy of 91% across all trials. The algorithm provided substantial performance in detecting the intraocular tissues with 100% reliability and 95% sensitivity for the lens, along with 88% reliability and 94% sensitivity for the vitreous. Conclusion: The developed impedance-based framework demonstrated successful intraocular tissue identification. Significance: Clinical implications include the ability to ensure safe operations by detecting posterior capsule rapture with 94% probability and improving surgical efficacy through lens detection with 100% reliability.
- 4 November 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Robotics
- Vol. 37 (2) , 404-417
Autonomous Suturing Framework and Quantification Using a Cable-Driven Surgical Robot
Suturing is required in almost all surgeries but it is challenging to perform with surgical robots due to limited vision and/or haptic feedback. To tackle this problem, we present an autonomous suturing framework that encompasses a novel needle path planner, as well as an accurate needle pose estimator and a six degrees-of-freedom controller. A novel needle grasper is developed that enables needle pose estimation both inside and outside the tissue. The framework was evaluated experimentally using the Raven IV surgical system and important suture parameters were quantified. The experiment results confirmed a needle pose estimation accuracy of < 0.87 mm in position and < 3.46 $^\circ$ in orientation across all directions. Moreover, the results revealed that using the proposed framework enabled following the reference needle trajectories with errors of 2.07 mm in position and 4.29 $^\circ$ in orientation. These are drastic improvements of more than 10× in position and 5× in orientation compared to the Raven IV kinematic controller. Additionally, the results verified that our framework delivered the desired clinical suture parameters successfully across tissue phantom environments with different mechanical properties and under various needle trajectories. A supplementary video can be found at: http://bionics.seas.ucla.edu/research/surgeryproject18.htmlhttp://bionics.seas.ucla.edu/research/surgeryproject18- 4 November 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Robotics
- Vol. 37 (2) , 404-417
Autonomous Suturing Framework and Quantification Using a Cable-Driven Surgical Robot
Suturing is required in almost all surgeries but it is challenging to perform with surgical robots due to limited vision and/or haptic feedback. To tackle this problem, we present an autonomous suturing framework that encompasses a novel needle path planner, as well as an accurate needle pose estimator and a six degrees-of-freedom controller. A novel needle grasper is developed that enables needle pose estimation both inside and outside the tissue. The framework was evaluated experimentally using the Raven IV surgical system and important suture parameters were quantified. The experiment results confirmed a needle pose estimation accuracy of < 0.87 mm in position and < 3.46 $^\circ$ in orientation across all directions. Moreover, the results revealed that using the proposed framework enabled following the reference needle trajectories with errors of 2.07 mm in position and 4.29 $^\circ$ in orientation. These are drastic improvements of more than 10× in position and 5× in orientation compared to the Raven IV kinematic controller. Additionally, the results verified that our framework delivered the desired clinical suture parameters successfully across tissue phantom environments with different mechanical properties and under various needle trajectories. A supplementary video can be found at: http://bionics.seas.ucla.edu/research/surgeryproject18.htmlhttp://bionics.seas.ucla.edu/research/surgeryproject18- 22 November 2019
- Published by Elsevier
- p. 193-206
Optimal Kinematic Design of the Link Lengths of a Hand Exoskeleton
- 22 November 2019
- Published by Elsevier
- p. 193-206
Optimal Kinematic Design of the Link Lengths of a Hand Exoskeleton
- Open Access
Toward Synergic Learning for Autonomous Manipulation of Deformable Tissues via Surgical Robots: An Approximate Q-Learning Approach
In this paper, we present a synergic learning algorithm to address the task of indirect manipulation of an unknown deformable tissue. Tissue manipulation is a common yet challenging task in various surgical interventions, which makes it a good candidate for robotic automation. We propose using a linear approximate Q-learning method in which human knowledge contributes to selecting useful yet simple features of tissue manipulation while the algorithm learns to take optimal actions and accomplish the task. The algorithm is implemented and evaluated on a simulation using the OpenCV and CHAI3D libraries. Successful simulation results for four different configurations which are based on realistic tissue manipulation scenarios are presented. Results indicate that with a careful selection of relatively simple and intuitive features, the developed Q-learning algorithm can successfully learn an optimal policy without any prior knowledge of tissue dynamics or camera intrinsic/extrinsic calibration parameters.
Open AccessToward Synergic Learning for Autonomous Manipulation of Deformable Tissues via Surgical Robots: An Approximate Q-Learning Approach
In this paper, we present a synergic learning algorithm to address the task of indirect manipulation of an unknown deformable tissue. Tissue manipulation is a common yet challenging task in various surgical interventions, which makes it a good candidate for robotic automation. We propose using a linear approximate Q-learning method in which human knowledge contributes to selecting useful yet simple features of tissue manipulation while the algorithm learns to take optimal actions and accomplish the task. The algorithm is implemented and evaluated on a simulation using the OpenCV and CHAI3D libraries. Successful simulation results for four different configurations which are based on realistic tissue manipulation scenarios are presented. Results indicate that with a careful selection of relatively simple and intuitive features, the developed Q-learning algorithm can successfully learn an optimal policy without any prior knowledge of tissue dynamics or camera intrinsic/extrinsic calibration parameters.
- Open Access
Autonomous Tissue Manipulation via Surgical Robot Using Learning Based Model Predictive Control
Tissue manipulation is a frequently used fundamental subtask of any surgical procedures, and in some cases it may require the involvement of a surgeon's assistant. The complex dynamics of soft tissue as an unstructured environment is one of the main challenges in any attempt to automate the manipulation of it via a surgical robotic system. Two AI learning based model predictive control algorithms using vision strategies are proposed and studied: (1) reinforcement learning and (2) learning from demonstration. Comparison of the performance of these AI algorithms in a simulation setting indicated that the learning from demonstration algorithm can boost the learning policy by initializing the predicted dynamics with given demonstrations. Furthermore, the learning from demonstration algorithm is implemented on a Raven IV surgical robotic system and successfully demonstrated feasibility of the proposed algorithm using an experimental approach. This study is part of a profound vision in which the role of a surgeon will be redefined as a pure decision maker whereas the vast majority of the manipulation will be conducted autonomously by a surgical robotic system. A supplementary video can be found at: http://bionics.seas.ucla.edu/research/surgeryproject17.html
Open AccessAutonomous Tissue Manipulation via Surgical Robot Using Learning Based Model Predictive Control
Tissue manipulation is a frequently used fundamental subtask of any surgical procedures, and in some cases it may require the involvement of a surgeon's assistant. The complex dynamics of soft tissue as an unstructured environment is one of the main challenges in any attempt to automate the manipulation of it via a surgical robotic system. Two AI learning based model predictive control algorithms using vision strategies are proposed and studied: (1) reinforcement learning and (2) learning from demonstration. Comparison of the performance of these AI algorithms in a simulation setting indicated that the learning from demonstration algorithm can boost the learning policy by initializing the predicted dynamics with given demonstrations. Furthermore, the learning from demonstration algorithm is implemented on a Raven IV surgical robotic system and successfully demonstrated feasibility of the proposed algorithm using an experimental approach. This study is part of a profound vision in which the role of a surgeon will be redefined as a pure decision maker whereas the vast majority of the manipulation will be conducted autonomously by a surgical robotic system. A supplementary video can be found at: http://bionics.seas.ucla.edu/research/surgeryproject17.html