Jia Li
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Jia Li has a total of 116 co-authors. Here are the top co-authors by number of shared publications:
- Peifu Tang
Senior Department of Orthopedics The Fourth Medical Center of Chinese PLA General Hospital Beijing China
3 shared publications - Fengjiao Zhang
School of Chemical Sciences University of Chinese Academy of Sciences Beijing China
2 shared publications - Hua Chen
Senior Department of Orthopedics, The Fourth Medical Center of PLA general hospital, Beijing, China
2 shared publications - Lihai Zhang
China Department of Orthopedics, Chinese PLA General Hospital, Beijing 100141, China
2 shared publications - Pengbin Yin
Department of Orthopedics, Chinese PLA General Hospital, Beijing 100853, China
2 shared publications Ziling Jiang
School of Chemical Sciences, University of Chinese Academy of Sciences, Beijing, 100049, China
2 shared publications
Latest Publications
- 19 July 2025
- Published by Elsevier in Biosensors and Bioelectronics
- Vol. 288, 117807
Drug functionalized organic electromechanical transistor for rapid and sensitive detection of C-reactive protein
- 19 July 2025
- Published by Elsevier in Biosensors and Bioelectronics
- Vol. 288, 117807
Drug functionalized organic electromechanical transistor for rapid and sensitive detection of C-reactive protein
- Open Access
- 30 June 2025
- Published by Wiley in Health Care Science
- Vol. 4 (4) , 250-258
The Failure Rate of Internal Fixation Increases With Sagittal Displacement of the Femoral Head: A Retrospective Study
Background: The risk of internal fixation failure remains relatively high in stable femoral neck fracture (FNF) (Garden I or II). Preoperative sagittal displacement of the femoral head has been proposed as a potential influencing factor. This study aimed to evaluate the impact of sagittal displacement on the outcomes of cannulated screw internal fixation (CSIF) in patients with stable FNF (Garden I or II) by reconstructing the axial sagittal oblique plane of the fracture using preoperative computed tomography (CT) imaging.Methods: This study included 167 patients with FNF who underwent CSIF. The sagittal tilt angle of the femoral head (STAFH) was evaluated using three‐dimensional CT (3D‐CT). The distribution of preoperative STAFH was analyzed, and its independent association with treatment failure was assessed. Treatment failure was defined as the need for revision surgery within 2 years postoperatively due to avascular necrosis, nonunion, or internal fixation failure.Results: Among the 167 patients, 9 (5.4%) exhibited anterior tilt (AT) of the femoral head, 158 (94.60%) presented with posterior tilt (PT). A total of 50 patients (29.9%) demonstrated excessive sagittal displacement (AT ≥ 10° or PT ≥ 20°). In the failure group, 80.0% of patients had excessive sagittal displacement compared to 28.1% in the healed group. Excessive sagittal displacement was significantly associated with an increased risk of surgical failure (odds ratio: 11.953, 95% CI: 3.656–39.083, p < 0.05).Conclusions: In patients with Garden I or II FNF, greater preoperative sagittal displacement of the femoral head was correlated with a higher likelihood of CSIF failure. AT ≥ 10° or PT ≥ 20° were identified as independent predictors of CSIF failure in FNF patients. Nevertheless, these findings still require confirmation through prospective, multi‐center clinical trials with large sample sizes.
- 30 June 2025
- Published by Wiley in Health Care Science
- Vol. 4 (4) , 250-258
Open AccessThe Failure Rate of Internal Fixation Increases With Sagittal Displacement of the Femoral Head: A Retrospective Study
Background: The risk of internal fixation failure remains relatively high in stable femoral neck fracture (FNF) (Garden I or II). Preoperative sagittal displacement of the femoral head has been proposed as a potential influencing factor. This study aimed to evaluate the impact of sagittal displacement on the outcomes of cannulated screw internal fixation (CSIF) in patients with stable FNF (Garden I or II) by reconstructing the axial sagittal oblique plane of the fracture using preoperative computed tomography (CT) imaging.Methods: This study included 167 patients with FNF who underwent CSIF. The sagittal tilt angle of the femoral head (STAFH) was evaluated using three‐dimensional CT (3D‐CT). The distribution of preoperative STAFH was analyzed, and its independent association with treatment failure was assessed. Treatment failure was defined as the need for revision surgery within 2 years postoperatively due to avascular necrosis, nonunion, or internal fixation failure.Results: Among the 167 patients, 9 (5.4%) exhibited anterior tilt (AT) of the femoral head, 158 (94.60%) presented with posterior tilt (PT). A total of 50 patients (29.9%) demonstrated excessive sagittal displacement (AT ≥ 10° or PT ≥ 20°). In the failure group, 80.0% of patients had excessive sagittal displacement compared to 28.1% in the healed group. Excessive sagittal displacement was significantly associated with an increased risk of surgical failure (odds ratio: 11.953, 95% CI: 3.656–39.083, p < 0.05).Conclusions: In patients with Garden I or II FNF, greater preoperative sagittal displacement of the femoral head was correlated with a higher likelihood of CSIF failure. AT ≥ 10° or PT ≥ 20° were identified as independent predictors of CSIF failure in FNF patients. Nevertheless, these findings still require confirmation through prospective, multi‐center clinical trials with large sample sizes.
- 7 August 2024
- Published by Springer Nature in Nature Materials
- Vol. 23 (11) , 1547-1555
A drug-mediated organic electrochemical transistor for robustly reusable biosensors
Reusable point-of-care biosensors offer a cost-effective solution for serial biomarker monitoring, addressing the critical demand for tumour treatments and recurrence diagnosis. However, their realization has been limited by the contradictory requirements of robust reusability and high sensing capability to multiple interactions among transducer surface, sensing probes and target analytes. Here we propose a drug-mediated organic electrochemical transistor as a robust, reusable epidermal growth factor receptor sensor with striking sensitivity and selectivity. By electrostatically adsorbing protonated gefitinib onto poly(3,4-ethylenedioxythiophene):polystyrene sulfonate and leveraging its strong binding to the epidermal growth factor receptor target, the device operates with a unique refresh-in-sensing mechanism. It not only yields an ultralow limit-of-detection concentration down to 5.74 fg ml−1 for epidermal growth factor receptor but, more importantly, also produces an unprecedented regeneration cycle exceeding 200. We further validate the potential of our devices for easy-to-use biomedical applications by creating an 8 × 12 diagnostic drug-mediated organic electrochemical transistor array with excellent uniformity to clinical blood samples.
- 7 August 2024
- Published by Springer Nature in Nature Materials
- Vol. 23 (11) , 1547-1555
A drug-mediated organic electrochemical transistor for robustly reusable biosensors
Reusable point-of-care biosensors offer a cost-effective solution for serial biomarker monitoring, addressing the critical demand for tumour treatments and recurrence diagnosis. However, their realization has been limited by the contradictory requirements of robust reusability and high sensing capability to multiple interactions among transducer surface, sensing probes and target analytes. Here we propose a drug-mediated organic electrochemical transistor as a robust, reusable epidermal growth factor receptor sensor with striking sensitivity and selectivity. By electrostatically adsorbing protonated gefitinib onto poly(3,4-ethylenedioxythiophene):polystyrene sulfonate and leveraging its strong binding to the epidermal growth factor receptor target, the device operates with a unique refresh-in-sensing mechanism. It not only yields an ultralow limit-of-detection concentration down to 5.74 fg ml−1 for epidermal growth factor receptor but, more importantly, also produces an unprecedented regeneration cycle exceeding 200. We further validate the potential of our devices for easy-to-use biomedical applications by creating an 8 × 12 diagnostic drug-mediated organic electrochemical transistor array with excellent uniformity to clinical blood samples.
- Open Access
- 16 April 2024
- Published by Springer Nature in Journal of Orthopaedic Surgery and Research
- Vol. 19 (1) , 1-15
Exosomes derived from M2 macrophages prevent steroid-induced osteonecrosis of the femoral head by modulating inflammation, promoting bone formation and inhibiting bone resorption
Inflammatory reactions are involved in the development of steroid-induced osteonecrosis of the femoral head(ONFH). Studies have explored the therapeutic efficacy of inhibiting inflammatory reactions in steroid-induced ONFH and revealed that inhibiting inflammation may be a new strategy for preventing the development of steroid-induced ONFH. Exosomes derived from M2 macrophages(M2-Exos) display anti-inflammatory properties. This study aimed to examine the preventive effect of M2-Exos on early-stage steroid-induced ONFH and explore the underlying mechanisms involved. In vitro, we explored the effect of M2-Exos on the proliferation and osteogenic differentiation of bone marrow-derived mesenchymal stem cells(BMMSCs). In vivo, we investigated the role of M2-Exos on inflammation, osteoclastogenesis, osteogenesis and angiogenesis in an early-stage rat model of steroid-induced ONFH. We found that M2-Exos promoted the proliferation and osteogenic differentiation of BMMSCs. Additionally, M2-Exos effectively attenuated the osteonecrotic changes, inhibited the expression of proinflammatory mediators, promoted osteogenesis and angiogenesis, reduced osteoclastogenesis, and regulated the polarization of M1/M2 macrophages in steroid-induced ONFH. Taken together, our data suggest that M2-Exos are effective at preventing steroid-induced ONFH. These findings may be helpful for providing a potential strategy to prevent the development of steroid-induced ONFH.
- 16 April 2024
- Published by Springer Nature in Journal of Orthopaedic Surgery and Research
- Vol. 19 (1) , 1-15
Open AccessExosomes derived from M2 macrophages prevent steroid-induced osteonecrosis of the femoral head by modulating inflammation, promoting bone formation and inhibiting bone resorption
Inflammatory reactions are involved in the development of steroid-induced osteonecrosis of the femoral head(ONFH). Studies have explored the therapeutic efficacy of inhibiting inflammatory reactions in steroid-induced ONFH and revealed that inhibiting inflammation may be a new strategy for preventing the development of steroid-induced ONFH. Exosomes derived from M2 macrophages(M2-Exos) display anti-inflammatory properties. This study aimed to examine the preventive effect of M2-Exos on early-stage steroid-induced ONFH and explore the underlying mechanisms involved. In vitro, we explored the effect of M2-Exos on the proliferation and osteogenic differentiation of bone marrow-derived mesenchymal stem cells(BMMSCs). In vivo, we investigated the role of M2-Exos on inflammation, osteoclastogenesis, osteogenesis and angiogenesis in an early-stage rat model of steroid-induced ONFH. We found that M2-Exos promoted the proliferation and osteogenic differentiation of BMMSCs. Additionally, M2-Exos effectively attenuated the osteonecrotic changes, inhibited the expression of proinflammatory mediators, promoted osteogenesis and angiogenesis, reduced osteoclastogenesis, and regulated the polarization of M1/M2 macrophages in steroid-induced ONFH. Taken together, our data suggest that M2-Exos are effective at preventing steroid-induced ONFH. These findings may be helpful for providing a potential strategy to prevent the development of steroid-induced ONFH.
- Open Access
- 14 December 2023
- Published by Elsevier in Journal of Orthopaedic Translation
- Vol. 44, 1-8
The association between anterior cruciate ligament degeneration and incident knee osteoarthritis: Data from the osteoarthritis initiative
- 14 December 2023
- Published by Elsevier in Journal of Orthopaedic Translation
- Vol. 44, 1-8
Open AccessThe association between anterior cruciate ligament degeneration and incident knee osteoarthritis: Data from the osteoarthritis initiative
- Open Access
- 15 September 2023
- Published by Springer Nature in Arthritis Research & Therapy
- Vol. 25 (1) , 1-13
Causal associations of Sjögren’s syndrome with cancers: a two-sample Mendelian randomization study
Background: Several observational studies have explored the associations between Sjögren’s syndrome (SS) and certain cancers. Nevertheless, the causal relationships remain unclear. Mendelian randomization (MR) method was used to investigate the causality between SS and different types of cancers. Methods: We conducted the two-sample Mendelian randomization with the public genome-wide association studies (GWASs) summary statistics in European population to evaluate the causality between SS and nine types of cancers. The sample size varies from 1080 to 372,373. The inverse variance weighted (IVW) method was used to estimate the causal effects. A Bonferroni-corrected threshold of P < 0.0031 was considered significant, and P value between 0.0031 and 0.05 was considered to be suggestive of an association. Sensitivity analysis was performed to validate the causality. Moreover, additional analysis was used to assess the associations between SS and well-accepted risk factors of cancers. Results: After correcting the heterogeneity and horizontal pleiotropy, the results indicated that patients with SS were significantly associated with an increased risk of lymphomas (odds ratio [OR] = 1.0010, 95% confidence interval [CI]: 1.0005–1.0015, P = 0.0002) and reduced risks of prostate cancer (OR = 0.9972, 95% CI: 0.9960–0.9985, P = 2.45 × 10−5) and endometrial cancer (OR = 0.9414, 95% CI: 0.9158–0.9676, P = 1.65 × 10−5). Suggestive associations were found in liver and bile duct cancer (OR = 0.9999, 95% CI: 0.9997–1.0000, P = 0.0291) and cancer of urinary tract (OR = 0.9996, 95% CI: 0.9992–1.0000, P = 0.0281). No causal effect of SS on other cancer types was detected. Additional MR analysis indicated that causal effects between SS and cancers were not mediated by the well-accepted risk factors of cancers. No evidence of the causal relationship was observed for cancers on SS. Conclusions: SS had significant causal relationships with lymphomas, prostate cancer, and endometrial cancer, and suggestive evidence of association was found in liver and bile duct cancer and cancer of urinary tract, indicating that SS may play a vital role in the incidence of these malignancies.
- 15 September 2023
- Published by Springer Nature in Arthritis Research & Therapy
- Vol. 25 (1) , 1-13
Open AccessCausal associations of Sjögren’s syndrome with cancers: a two-sample Mendelian randomization study
Background: Several observational studies have explored the associations between Sjögren’s syndrome (SS) and certain cancers. Nevertheless, the causal relationships remain unclear. Mendelian randomization (MR) method was used to investigate the causality between SS and different types of cancers. Methods: We conducted the two-sample Mendelian randomization with the public genome-wide association studies (GWASs) summary statistics in European population to evaluate the causality between SS and nine types of cancers. The sample size varies from 1080 to 372,373. The inverse variance weighted (IVW) method was used to estimate the causal effects. A Bonferroni-corrected threshold of P < 0.0031 was considered significant, and P value between 0.0031 and 0.05 was considered to be suggestive of an association. Sensitivity analysis was performed to validate the causality. Moreover, additional analysis was used to assess the associations between SS and well-accepted risk factors of cancers. Results: After correcting the heterogeneity and horizontal pleiotropy, the results indicated that patients with SS were significantly associated with an increased risk of lymphomas (odds ratio [OR] = 1.0010, 95% confidence interval [CI]: 1.0005–1.0015, P = 0.0002) and reduced risks of prostate cancer (OR = 0.9972, 95% CI: 0.9960–0.9985, P = 2.45 × 10−5) and endometrial cancer (OR = 0.9414, 95% CI: 0.9158–0.9676, P = 1.65 × 10−5). Suggestive associations were found in liver and bile duct cancer (OR = 0.9999, 95% CI: 0.9997–1.0000, P = 0.0291) and cancer of urinary tract (OR = 0.9996, 95% CI: 0.9992–1.0000, P = 0.0281). No causal effect of SS on other cancer types was detected. Additional MR analysis indicated that causal effects between SS and cancers were not mediated by the well-accepted risk factors of cancers. No evidence of the causal relationship was observed for cancers on SS. Conclusions: SS had significant causal relationships with lymphomas, prostate cancer, and endometrial cancer, and suggestive evidence of association was found in liver and bile duct cancer and cancer of urinary tract, indicating that SS may play a vital role in the incidence of these malignancies.
- Open Access
- 1 November 2021
- Published by Elsevier in International Journal of Radiation Oncology - Biology - Physics (IJROBP)
- Vol. 111 (3) , e241
Is the Equivalent Uniform Dose Model Being Used Properly? Impact of Dose Distribution on Parameter and Predictive Ability
- 1 November 2021
- Published by Elsevier in International Journal of Radiation Oncology - Biology - Physics (IJROBP)
- Vol. 111 (3) , e241
Open AccessIs the Equivalent Uniform Dose Model Being Used Properly? Impact of Dose Distribution on Parameter and Predictive Ability
- Open Access
- 1 January 2021
- Published by Wiley in BioMed Research International
- Vol. 2021 (1)
A Finite Element Study on the Treatment of Thoracolumbar Fracture with a New Spinal Fixation System
Objective. In this study, the mechanical properties of the new spinal fixation system (NSFS) in the treatment of thoracolumbar fractures were evaluated by the finite element analysis method, so as to provide a mechanical theoretical basis for the later biomechanical experiments and clinical experiments. Methods. T12‐L2 bone model was constructed to simulate L1 vertebral fracture, and three models of internal fixation systems were established on the basis of universal spinal system (USS): Model A: posterior short‐segment fixation including the fractured vertebra (PSFFV); Model B: short‐segment pedicle screw fixation (SSPF); Model C: new spinal fixation system (NSFS). After assembling the internal fixation system and fracture model, the finite element analysis was carried out in the ANSYS Workbench 18.0 software, and the stress of nail rod system, fracture vertebral body stress, vertebral body mobility, and vertebral body displacement were recorded in the three models. Results. The peak values of internal fixation stress, vertebral body stress, vertebral body maximum displacement, and vertebral body maximum activity in Model C were slightly smaller than those in Model B. Conclusions. Compared with the traditional internal fixation system, the new spinal internal fixation system may have the mechanical advantage and can provide sufficient mechanical stability for thoracolumbar fractures.
- 1 January 2021
- Published by Wiley in BioMed Research International
- Vol. 2021 (1)
Open AccessA Finite Element Study on the Treatment of Thoracolumbar Fracture with a New Spinal Fixation System
Objective. In this study, the mechanical properties of the new spinal fixation system (NSFS) in the treatment of thoracolumbar fractures were evaluated by the finite element analysis method, so as to provide a mechanical theoretical basis for the later biomechanical experiments and clinical experiments. Methods. T12‐L2 bone model was constructed to simulate L1 vertebral fracture, and three models of internal fixation systems were established on the basis of universal spinal system (USS): Model A: posterior short‐segment fixation including the fractured vertebra (PSFFV); Model B: short‐segment pedicle screw fixation (SSPF); Model C: new spinal fixation system (NSFS). After assembling the internal fixation system and fracture model, the finite element analysis was carried out in the ANSYS Workbench 18.0 software, and the stress of nail rod system, fracture vertebral body stress, vertebral body mobility, and vertebral body displacement were recorded in the three models. Results. The peak values of internal fixation stress, vertebral body stress, vertebral body maximum displacement, and vertebral body maximum activity in Model C were slightly smaller than those in Model B. Conclusions. Compared with the traditional internal fixation system, the new spinal internal fixation system may have the mechanical advantage and can provide sufficient mechanical stability for thoracolumbar fractures.
- 20 June 2020
- Published by International Scientific Information, Inc. in Medical Science Monitor
- Vol. 26, e921823-1-e921823-8
Finite Element Analysis of the Effect of Talar Osteochondral Defects of Different Depths on Ankle Joint Stability
Talus cartilage injury leads to changes in biomechanics of the ankle joint and ultimately affects ankle joint function, but which talus cartilage defects require surgery is still uncertain. This research used a finite element method to simulate the effect of different depth of talus cartilage defects on the stress and stability of the ankle joint in a certain area. A three-dimensional finite element model with different depths of osteochondral defects was created to simulate and calculate joint stress and displacement of the articular surface of the distal tibia and the proximal talus while the ankle joint was in the push-off, midstance, and heel-strike phases. The equivalent stress of the proximal talus did not change significantly at a defect depth of 1 mm, whereas the equivalent stress of the upper talus increased significantly at a defect depth of ≥3 mm or more, reaching a maximum value at a defect depth of 10 mm. The equivalent stress of the tibial cartilage and the equivalent stress and displacement in the corresponding forces in the midstance phase and heel-strike phase were significantly different from those in the normal group, but the difference in stress in each defect group was not obvious. The effect of cartilage defects of the talus on biomechanics of the ankle is clear, especially in the midstance and push-off phases. When the defect reaches the subchondral bone (at a depth of 3 mm), the most obvious change in ankle joint stability occurs, and it does not increase linearly with the increase in depth of the defect.
- 20 June 2020
- Published by International Scientific Information, Inc. in Medical Science Monitor
- Vol. 26, e921823-1-e921823-8
Finite Element Analysis of the Effect of Talar Osteochondral Defects of Different Depths on Ankle Joint Stability
Talus cartilage injury leads to changes in biomechanics of the ankle joint and ultimately affects ankle joint function, but which talus cartilage defects require surgery is still uncertain. This research used a finite element method to simulate the effect of different depth of talus cartilage defects on the stress and stability of the ankle joint in a certain area. A three-dimensional finite element model with different depths of osteochondral defects was created to simulate and calculate joint stress and displacement of the articular surface of the distal tibia and the proximal talus while the ankle joint was in the push-off, midstance, and heel-strike phases. The equivalent stress of the proximal talus did not change significantly at a defect depth of 1 mm, whereas the equivalent stress of the upper talus increased significantly at a defect depth of ≥3 mm or more, reaching a maximum value at a defect depth of 10 mm. The equivalent stress of the tibial cartilage and the equivalent stress and displacement in the corresponding forces in the midstance phase and heel-strike phase were significantly different from those in the normal group, but the difference in stress in each defect group was not obvious. The effect of cartilage defects of the talus on biomechanics of the ankle is clear, especially in the midstance and push-off phases. When the defect reaches the subchondral bone (at a depth of 3 mm), the most obvious change in ankle joint stability occurs, and it does not increase linearly with the increase in depth of the defect.
- Open Access
Medial anatomical buttress plate in treating displaced femoral neck fracture a finite element analysis