James C. Weatherall
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
James C. Weatherall has a total of 15 co-authors. Here are the top co-authors by number of shared publications:
Jeffrey Barber
U.S. Dept. of Homeland Security (United States)
6 shared publicationsPeter R. Smith
MAG Aerospace, Fairfax, Virginia, United States
6 shared publicationsBarry T. Smith
U.S. Department of Homeland Security (United States)
2 shared publicationsDuane C. Karns
William J. Hughes Technical Center, U.S. Department of Homeland Security, Science and Technology Directorate, Atlantic City International Airport, New Jersey, United States
2 shared publications- Jeffrey Barber
U.S. Department of Homeland Security, Science and Technology Directorate, William J. Hughes Technical Center, Transportation Security Laboratory, International Airport, Atlantic City, New Jersey, United States
2 shared publications - Joaquín Aparicio-Bolaño
Battelle Memorial Institute, Egg Harbor Township, New Jersey, United States
2 shared publications
Latest Publications
- 29 May 2025
- Published by SPIE-Intl Soc Optical Eng
- Vol. 13471, 20-168
Assessing permittivity dependence on inhomogeneities in materials
Permittivity measurements are performed with the two-port filled WR-75 rectangular waveguide technique (frequency 10 - 15 GHz). Samples are 3D-printed rectangular prisms of 100% infill Polylactic acid (PLA) with cavities of differing size, position, geometry, and directional orientation to test a variety of inhomogeneities. S-parameter data are collected and fit to curves from theory with four free parameters: real permittivity, imaginary permittivity, and the two displacements of the sample from the calibration planes. The optimized complex permittivity is taken as the measure. Measured values for permittivity of solid PLA are in good agreement with literature. The measured real permittivity for samples is consistent with the Landau-Lifshitz/Looyenga (LLL) mixing formula, although there is a weak variance with void geometry. However, results of the S-parameter fit indicate that the losses within the inhomogeneous samples are sensitive to geometry and directional orientation.
- 29 May 2025
- Published by SPIE-Intl Soc Optical Eng
- Vol. 13471, 20-168
Assessing permittivity dependence on inhomogeneities in materials
Permittivity measurements are performed with the two-port filled WR-75 rectangular waveguide technique (frequency 10 - 15 GHz). Samples are 3D-printed rectangular prisms of 100% infill Polylactic acid (PLA) with cavities of differing size, position, geometry, and directional orientation to test a variety of inhomogeneities. S-parameter data are collected and fit to curves from theory with four free parameters: real permittivity, imaginary permittivity, and the two displacements of the sample from the calibration planes. The optimized complex permittivity is taken as the measure. Measured values for permittivity of solid PLA are in good agreement with literature. The measured real permittivity for samples is consistent with the Landau-Lifshitz/Looyenga (LLL) mixing formula, although there is a weak variance with void geometry. However, results of the S-parameter fit indicate that the losses within the inhomogeneous samples are sensitive to geometry and directional orientation.
- 1 May 2025
- Published by SPIE-Intl Soc Optical Eng in Optical Engineering
- Vol. 64 (05) , 054108-11
Measuring the refractive index of materials with very low reflection coefficients at millimeter wavelengths
Structural materials that are virtually invisible during millimeter-wave imaging are needed for applications in testing advanced imaging technology screening systems, for example, by supporting image-quality test objects. Laboratory measurement of the electrical permittivity of candidate materials at the frequency of the imaging system can appraise their suitability as very low-reflective materials, but the measurement is challenging because the ideal material has a real component of permittivity near unity and nearly zero propagation loss. A method is described based on temporal features in wave packet propagation using dual calibrations for front and back interfaces. Measurements of different foam materials are demonstrated.
- 1 May 2025
- Published by SPIE-Intl Soc Optical Eng in Optical Engineering
- Vol. 64 (05) , 054108-11
Measuring the refractive index of materials with very low reflection coefficients at millimeter wavelengths
Structural materials that are virtually invisible during millimeter-wave imaging are needed for applications in testing advanced imaging technology screening systems, for example, by supporting image-quality test objects. Laboratory measurement of the electrical permittivity of candidate materials at the frequency of the imaging system can appraise their suitability as very low-reflective materials, but the measurement is challenging because the ideal material has a real component of permittivity near unity and nearly zero propagation loss. A method is described based on temporal features in wave packet propagation using dual calibrations for front and back interfaces. Measurements of different foam materials are demonstrated.
- 7 June 2024
- Published by SPIE-Intl Soc Optical Eng
- Vol. 13048, 235-241
Measuring the refractive index of foam materials with very low reflection coefficients at millimeter wavelengths
Structural materials that are virtually invisible during millimeter-wave imaging are needed for applications in testing Advanced Imaging Technology (AIT) screening systems, for example by supporting image-quality test objects. Laboratory measurement of the electrical permittivity of candidate materials at the frequency of the imaging system can appraise their suitability as very low-reflective materials, but measurement is challenging because the ideal material has a real component of permittivity near unity and nearly zero propagation loss. A method is described based on temporal features in wave packet propagation using dual calibrations for front and back interfaces. Measurements of different foam materials are demonstrated.
- 7 June 2024
- Published by SPIE-Intl Soc Optical Eng
- Vol. 13048, 235-241
Measuring the refractive index of foam materials with very low reflection coefficients at millimeter wavelengths
Structural materials that are virtually invisible during millimeter-wave imaging are needed for applications in testing Advanced Imaging Technology (AIT) screening systems, for example by supporting image-quality test objects. Laboratory measurement of the electrical permittivity of candidate materials at the frequency of the imaging system can appraise their suitability as very low-reflective materials, but measurement is challenging because the ideal material has a real component of permittivity near unity and nearly zero propagation loss. A method is described based on temporal features in wave packet propagation using dual calibrations for front and back interfaces. Measurements of different foam materials are demonstrated.
- Open Access
- 29 December 2023
- Published by SPIE-Intl Soc Optical Eng in Journal of Applied Remote Sensing
- Vol. 18 (01) , 014501-10
Loaded waveguide measurements of plastic explosives at V-band
Dielectric measurements of plastic explosives using a loaded waveguide technique via vector network analyzer and banded millimeter wave extender modules operating at V-band (50 to 75 GHz) are performed. A portion of an explosive sample is inserted into a waveguide shim 2 mm in length and trimmed flush with the faces of the shim. Two-port S-parameter measurements are conducted on the explosive; the empty shim is similarly characterized. Using standard waveguide equations and the measured length of the shim, the complex S-parameter data obtained with the filled shim is optimized to four free parameters—complex permittivity and distance offsets for the two sample faces relative to the calibration planes. Permittivity data obtained from measurements of the plastic explosives C-4, Primasheet 1000, Primasheet 2000 and Semtex 10 are presented. Results obtained for C-4 and Primasheet 1000 are comparable to other data in the literature, and the data on Primasheet 2000 and Semtex 10 are the first known published permittivity values in this range. Excellent agreement between the experiment and the fit is obtained using a constant permittivity across the waveguide band, indicating that dispersion is not significant for these materials.
- 29 December 2023
- Published by SPIE-Intl Soc Optical Eng in Journal of Applied Remote Sensing
- Vol. 18 (01) , 014501-10
Open AccessLoaded waveguide measurements of plastic explosives at V-band
Dielectric measurements of plastic explosives using a loaded waveguide technique via vector network analyzer and banded millimeter wave extender modules operating at V-band (50 to 75 GHz) are performed. A portion of an explosive sample is inserted into a waveguide shim 2 mm in length and trimmed flush with the faces of the shim. Two-port S-parameter measurements are conducted on the explosive; the empty shim is similarly characterized. Using standard waveguide equations and the measured length of the shim, the complex S-parameter data obtained with the filled shim is optimized to four free parameters—complex permittivity and distance offsets for the two sample faces relative to the calibration planes. Permittivity data obtained from measurements of the plastic explosives C-4, Primasheet 1000, Primasheet 2000 and Semtex 10 are presented. Results obtained for C-4 and Primasheet 1000 are comparable to other data in the literature, and the data on Primasheet 2000 and Semtex 10 are the first known published permittivity values in this range. Excellent agreement between the experiment and the fit is obtained using a constant permittivity across the waveguide band, indicating that dispersion is not significant for these materials.
- 14 June 2023
- Published by SPIE-Intl Soc Optical Eng
- Vol. 12535, 156-166
Loaded waveguide measurements of plastic explosives at V-band
Dielectric measurements of plastic explosives using a loaded waveguide technique via vector network analyzer and banded MMW extender modules operating at V-band (50 – 75 GHz) are performed. A portion of explosive sample is inserted into a waveguide shim 2mm in length and trimmed flush with the faces of the shim. Two-port S-parameter measurements were conducted on the explosive; the empty shim is similarly characterized. Using standard waveguide equations and the measured length of the shim, the complex S-parameter data obtained with the filled shim is optimized to four free parameters — complex permittivity and distance offsets for the two sample faces relative to the calibration planes. Permittivity data obtained from measurements of the plastic explosives C-4, Primasheet 1000, Primasheet 2000 and Semtex 10 are presented. Results obtained for C-4 are comparable to other data in open literature. Excellent agreement between the experiment and the fit is obtained using a constant permittivity across the waveguide band, indicating that dispersion is not significant for these materials.
- 14 June 2023
- Published by SPIE-Intl Soc Optical Eng
- Vol. 12535, 156-166
Loaded waveguide measurements of plastic explosives at V-band
Dielectric measurements of plastic explosives using a loaded waveguide technique via vector network analyzer and banded MMW extender modules operating at V-band (50 – 75 GHz) are performed. A portion of explosive sample is inserted into a waveguide shim 2mm in length and trimmed flush with the faces of the shim. Two-port S-parameter measurements were conducted on the explosive; the empty shim is similarly characterized. Using standard waveguide equations and the measured length of the shim, the complex S-parameter data obtained with the filled shim is optimized to four free parameters — complex permittivity and distance offsets for the two sample faces relative to the calibration planes. Permittivity data obtained from measurements of the plastic explosives C-4, Primasheet 1000, Primasheet 2000 and Semtex 10 are presented. Results obtained for C-4 are comparable to other data in open literature. Excellent agreement between the experiment and the fit is obtained using a constant permittivity across the waveguide band, indicating that dispersion is not significant for these materials.
- 14 June 2023
- Published by SPIE-Intl Soc Optical Eng
- Vol. 12535, 24-186
Partial image reconstruction adapted to extracting the frequency spectrum of discrete targets in millimeter-wave AIT images
Millimeter-wave imaging is used in Advanced Imaging Technology (AIT) screening systems to detect concealed objects based on the received radio frequency (RF) signals. The RF signals are collected and digitized from multiple frequencies and multiple antenna positions. We show that the measured frequency response of a targeted object can determine its complex refractive index and provide information on the material composition. This paper shows a method to compute the frequency spectrum from an image reconstructed using a partial set of antennas for which the radar reflection is most likely to be specular.
- 14 June 2023
- Published by SPIE-Intl Soc Optical Eng
- Vol. 12535, 24-186
Partial image reconstruction adapted to extracting the frequency spectrum of discrete targets in millimeter-wave AIT images
Millimeter-wave imaging is used in Advanced Imaging Technology (AIT) screening systems to detect concealed objects based on the received radio frequency (RF) signals. The RF signals are collected and digitized from multiple frequencies and multiple antenna positions. We show that the measured frequency response of a targeted object can determine its complex refractive index and provide information on the material composition. This paper shows a method to compute the frequency spectrum from an image reconstructed using a partial set of antennas for which the radar reflection is most likely to be specular.
- 14 June 2023
- Published by SPIE-Intl Soc Optical Eng
- Vol. 12535, 148-155
Application of the Boltzmann-Ehrenfest principle to the resonant frequency shift of a radio-wave electromagnetic cavity containing a dielectric object
The addition of a dielectric object into an electromagnetic cavity has the effect of modifying the resonant frequency. We find that the introduction of a highly polarizable cylinder changes the frequency in a way that is not linear with its volume, which is not expected from perturbation theory in the way it is usually applied. From the Boltzmann-Ehrenfest theorem, the ratio of frequency to the total energy remains constant for an adiabatic change to the oscillating system. The perturbed frequency can be computed accurately from the change in energy associated with the work performed when introducing the cylindrical volume to the cavity.
- 14 June 2023
- Published by SPIE-Intl Soc Optical Eng
- Vol. 12535, 148-155
Application of the Boltzmann-Ehrenfest principle to the resonant frequency shift of a radio-wave electromagnetic cavity containing a dielectric object
The addition of a dielectric object into an electromagnetic cavity has the effect of modifying the resonant frequency. We find that the introduction of a highly polarizable cylinder changes the frequency in a way that is not linear with its volume, which is not expected from perturbation theory in the way it is usually applied. From the Boltzmann-Ehrenfest theorem, the ratio of frequency to the total energy remains constant for an adiabatic change to the oscillating system. The perturbed frequency can be computed accurately from the change in energy associated with the work performed when introducing the cylindrical volume to the cavity.
- 3 June 2022
- Published by SPIE-Intl Soc Optical Eng
- Vol. 12111, 15-82
Simulations of millimeter-wave reflectivity in free space for dielectric measurement
Measurement of reflectivity in free space is a useful technique to quantify the refractive index and associated dielectric constant of materials at millimeter-wave frequencies. The configuration of the target and the incident and scattered radiation fields are often idealized, and the analytic models can be studied numerically to improve measurement precision. A finite element (FE) 2D model of a free space dielectric measurement system at 60-90 GHz is presented with an example target consisting of a partially transparent “disk” on metal with assigned characteristic dielectric values. The simulated data for the reflected signal at the antenna are compared with the predicted reflection spectra and are analyzed to derive the “measured” dielectric constant. The efficacy of using an aperture in the measurement system to control the beam and reduce the required target dimensions is demonstrated. A method to use an array of antenna elements to reduce the illuminated spot size is also explored.
- 3 June 2022
- Published by SPIE-Intl Soc Optical Eng
- Vol. 12111, 15-82
Simulations of millimeter-wave reflectivity in free space for dielectric measurement
Measurement of reflectivity in free space is a useful technique to quantify the refractive index and associated dielectric constant of materials at millimeter-wave frequencies. The configuration of the target and the incident and scattered radiation fields are often idealized, and the analytic models can be studied numerically to improve measurement precision. A finite element (FE) 2D model of a free space dielectric measurement system at 60-90 GHz is presented with an example target consisting of a partially transparent “disk” on metal with assigned characteristic dielectric values. The simulated data for the reflected signal at the antenna are compared with the predicted reflection spectra and are analyzed to derive the “measured” dielectric constant. The efficacy of using an aperture in the measurement system to control the beam and reduce the required target dimensions is demonstrated. A method to use an array of antenna elements to reduce the illuminated spot size is also explored.
- Open Access
- 7 January 2022
- Published by Springer Nature in Scientific Reports
- Vol. 12 (1) , 1-9
Statistical analysis for explosives detection system test and evaluation
The verification of trace explosives detection systems is often constrained to small sample sets, so it is important to support the significance of the results with statistical analysis. As binary measurements, the trials are assessed using binomial statistics. A method is described based on the probability confidence interval and expressed in terms of the upper confidence interval bound that reports the probability of successful detection and its level of statistical confidence. These parameters provide useful measures of the system’s performance. The propriety of combining statistics for similar tests—for example in trace detection trials of an explosive on multiple surfaces—is examined by statistical tests. The use of normal statistics is commonly applied to binary testing, but the confidence intervals are known to behave poorly in many circumstances, including small sample numbers. The improvement of the normal approximation with increasing sample number is shown not to be substantial for the typical numbers used in this type of explosives detection system testing, and binary statistics are preferred. The methods and techniques described here for testing trace detection can be applied as well to performance testing of explosives detection systems in general.
- 7 January 2022
- Published by Springer Nature in Scientific Reports
- Vol. 12 (1) , 1-9
Open AccessStatistical analysis for explosives detection system test and evaluation
The verification of trace explosives detection systems is often constrained to small sample sets, so it is important to support the significance of the results with statistical analysis. As binary measurements, the trials are assessed using binomial statistics. A method is described based on the probability confidence interval and expressed in terms of the upper confidence interval bound that reports the probability of successful detection and its level of statistical confidence. These parameters provide useful measures of the system’s performance. The propriety of combining statistics for similar tests—for example in trace detection trials of an explosive on multiple surfaces—is examined by statistical tests. The use of normal statistics is commonly applied to binary testing, but the confidence intervals are known to behave poorly in many circumstances, including small sample numbers. The improvement of the normal approximation with increasing sample number is shown not to be substantial for the typical numbers used in this type of explosives detection system testing, and binary statistics are preferred. The methods and techniques described here for testing trace detection can be applied as well to performance testing of explosives detection systems in general.
- 12 April 2021
- Published by SPIE-Intl Soc Optical Eng
- Vol. 11745, 117450K
Simulant development of a powder explosive material for a millimeter wave imaging system using a resonant cavity with ensemble averaging and the Houston criterion
This work describes the characterization of a powder threat material and the development of a dielectric simulant for a millimeter wave imaging system. A resonant cavity measurement system was designed and implemented to characterize the permittivity of the powder threat material and the candidate simulant formulation for the frequency range of the millimeter wave imaging system. The Resonant Cavity Measurement System determines the complex permittivity of the material as a function of density. A reflection coefficient is calculated at each frequency from a Fresnel reflection and transmission model developed in the electromagnetic signatures of explosives laboratory. The model allows different backing materials (skin and air) and material thicknesses to be examined. Finally, the Houston Criterion is applied to determine whether the matched simulant material and its paired explosive material can be distinguished from each other by the millimeter wavelength imaging system. The explosive material and the simulant material were found to be a dielectric match for use with the millimeter wavelength imaging system of interest with both backing materials (skin and air). The Houston criterion for resolvability was not exceeded for any thickness for either backing material. Therefore, the two materials are indistinguishable by the millimeter wavelength imaging system of interest.
- 12 April 2021
- Published by SPIE-Intl Soc Optical Eng
- Vol. 11745, 117450K
Simulant development of a powder explosive material for a millimeter wave imaging system using a resonant cavity with ensemble averaging and the Houston criterion
This work describes the characterization of a powder threat material and the development of a dielectric simulant for a millimeter wave imaging system. A resonant cavity measurement system was designed and implemented to characterize the permittivity of the powder threat material and the candidate simulant formulation for the frequency range of the millimeter wave imaging system. The Resonant Cavity Measurement System determines the complex permittivity of the material as a function of density. A reflection coefficient is calculated at each frequency from a Fresnel reflection and transmission model developed in the electromagnetic signatures of explosives laboratory. The model allows different backing materials (skin and air) and material thicknesses to be examined. Finally, the Houston Criterion is applied to determine whether the matched simulant material and its paired explosive material can be distinguished from each other by the millimeter wavelength imaging system. The explosive material and the simulant material were found to be a dielectric match for use with the millimeter wavelength imaging system of interest with both backing materials (skin and air). The Houston criterion for resolvability was not exceeded for any thickness for either backing material. Therefore, the two materials are indistinguishable by the millimeter wavelength imaging system of interest.